Pulse oximetry: Principles and limitations
The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tremper, K. K., & Barker, S. J. (1989) · Anesthesiology · doi:10.1097/00000542-198901000-00019 · Cited by 435
Effects of Methemoglobinemia on Pulse Oximetry and Mixed Venous Oximetry
Barker, S. J., Tremper, K. K., & Hyatt, J. (1989) · Anesthesiology · doi:10.1097/00000542-198901000-00021 · Cited by 382
Recent Developments in Pulse Oximetry
Biebuyck, J. F., Severinghaus, J. W., & Kelleher, J. F. (1992) · Anesthesiology · doi:10.1097/00000542-199206000-00024 · Cited by 333
Accuracy of Response of Six Pulse Oximeters to Profound Hypoxia
Severinghaus, J. W., & Naifeh, K. H. (1987) · Anesthesiology · doi:10.1097/00000542-198710000-00017 · Cited by 312
Pulse oximetry: Analysis of theory, technology, and practice
Wukitsch, M. W., Petterson, M. T., Tobler, D. R., & Pologe, J. A. (1988) · Journal of Clinical Monitoring · doi:10.1007/bf01617328 · Cited by 306
The Effect of Carbon Monoxide Inhalation on Pulse Oximetry and Transcutaneous Po 2
Barker, S. J., & Tremper, K. K. (1987) · Anesthesiology · doi:10.1097/00000542-198705000-00014 · Cited by 281
Kelleher, J. F. (1989) · Journal of Clinical Monitoring · doi:10.1007/bf01618369 · Cited by 202
Effects of Intravenously Administered Dyes on Pulse Oximetry Readings
SCHELLER, M. S., UNGER, R. J., & KELNER, M. J. (1986) · Anesthesiology · doi:10.1097/00000542-198611000-00023 · Cited by 194
Schnapp, L. M., & Cohen, N. H. (1990) · Chest · doi:10.1378/chest.98.5.1244 · Cited by 193
The Effect of Nail Polish on Pulse Oximetry
Cot??, C. J., Goldstein, E. A., Fuchsman, W. H., & Hoaglin, D. C. (1988) · Anesthesia & Analgesia · doi:10.1213/00000539-198807000-00013 · Cited by 172
Cited by
Smart wearable systems: Current status and future challenges
Chan, M., Estève, D., Fourniols, J.-Y., Escriba, C., & Campo, E. (2012) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2012.09.003 · Cited by 953
Outcomes for COPD pharmacological trials: from lung function to biomarkers
Cazzola, M., MacNee, W., Martinez, F. J., Rabe, K. F., Franciosi, L. G., Barnes, P. J., Brusasco, V., Burge, P. S., Calverley, P. M. A., Celli, B. R., et al. (2008) · European Respiratory Journal · doi:10.1183/09031936.00099306 · Cited by 858
Pulse oximetry: Understanding its basic principles facilitates appreciation of its limitations
Chan, E. D., Chan, M. M., & Chan, M. M. (2013) · Respiratory Medicine · doi:10.1016/j.rmed.2013.02.004 · Cited by 710
Pinto Lima, A., Beelen, P., & Bakker, J. (2002) · Critical Care Medicine · doi:10.1097/00003246-200206000-00006 · Cited by 476
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 422
Miniaturized Battery‐Free Wireless Systems for Wearable Pulse Oximetry
Kim, J., Gutruf, P., Chiarelli, A. M., Heo, S. Y., Cho, K., Xie, Z., Banks, A., Han, S., Jang, K., Lee, J. W., et al. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201604373 · Cited by 334
Overnight Pulse Oximetry for Sleep-Disordered Breathing in Adults
Netzer, N., Eliasson, A. H., Netzer, C., & Kristo, D. A. (2001) · Chest · doi:10.1378/chest.120.2.625 · Cited by 311
Luks, A. M., & Swenson, E. R. (2020) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202005-418fr · Cited by 263
Vashist, S., Schneider, E., & Luong, J. (2014) · Diagnostics · doi:10.3390/diagnostics4030104 · Cited by 244
“The technology is based on the non-invasive pulse oximetry method [90,91] that involves the passing of red (660 nm) and infrared (910 nm) light through perfused tissue to detect the fluctuating signal due to arterial pulses.”
Chipara, O., Lu, C., Bailey, T. C., & Roman, G.-C. (2010) · Proceedings of the 8th ACM Conference on Embedded Networked Sensor Systems · doi:10.1145/1869983.1869999 · Cited by 232
“The quality of pulse and oxygenation readings was significantly affected by patient movement, sensor disconnections, sensor placement, and nail polish2; this experience is consistent with results previously reported in literature [22].”
ResultA Motion-Tolerant Adaptive Algorithm for Wearable Photoplethysmographic Biosensors
Yousefi, R., Nourani, M., Ostadabbas, S., & Panahi, I. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2264358 · Cited by 228
Flexible inorganic bioelectronics
Chen, Y., Zhang, Y., Liang, Z., Cao, Y., Han, Z., & Feng, X. (2020) · npj Flexible Electronics · doi:10.1038/s41528-020-0065-1 · Cited by 227
Pulse Oximetry in Pediatric Practice
Fouzas, S., Priftis, K. N., & Anthracopoulos, M. B. (2011) · Pediatrics · doi:10.1542/peds.2011-0271 · Cited by 219
Kim, K. B., & Baek, H. J. (2023) · Electronics · doi:10.3390/electronics12132923 · Cited by 212
“This choice was based on the significant difference in light absorption between oxyhemoglobin (HbO 2 ) and deoxyhemoglobin (Hb) at these two wavelengths [22,71,72].”
Oxygen‐Sensing Methods in Biomedicine from the Macroscale to the Microscale
Roussakis, E., Li, Z., Nichols, A. J., & Evans, C. L. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201410646 · Cited by 184
Downs, A. M., & Plaxco, K. W. (2022) · ACS Sensors · doi:10.1021/acssensors.2c01428 · Cited by 175
Adult Toxicology in Critical Carea
Mokhlesi, B., Leikin, J. B., Murray, P., & Corbridge, T. C. (2003) · Chest · doi:10.1378/chest.123.3.897 · Cited by 162
A History of Pediatric Critical Care Medicine
Epstein, D., & Brill, J. E. (2005) · Pediatric Research · doi:10.1203/01.pdr.0000182822.16263.3d · Cited by 159
Cabanas, A. M., Fuentes-Guajardo, M., Latorre, K., León, D., & Martín-Escudero, P. (2022) · Sensors · doi:10.3390/s22093402 · Cited by 124
“Different factors have been examined to determine the influence on the accuracy of pulse oximetry such as skin pigmentation [24], body temperature [25], altitude [26], barometric pressure [27], nail polish or henna [28], or motion artifact [29].”
BackgroundDevice and method for noninvasive glucose assessment
Segman, Y. (. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818763457 · Cited by 55
Sleep quality prediction in caregivers using physiological signals
Sadeghi, R., Banerjee, T., Hughes, J. C., & Lawhorne, L. W. (2019) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2019.05.010 · Cited by 50
“Since E4 wristbands provide PPG (also known as blood volume pulse) based on pulse oximetry [68], we focus on calculating IBI from the PPG.”
MethodHaxha, S., Nwibor, C., Ali, M., Sakel, M., Saunders, K., Dyo, V., & Nabakooza, S. (2024) · Sensors · doi:10.3390/s24113301 · Cited by 12
“Consequently, pulse oximeters utilise two wavelengths: NIR at 940 nm and red light at 660 nm [2,33,34].”
BackgroundReal-Time Quality Index to Control Data Loss in Real-Life Cardiac Monitoring Applications
Vila, G., Godin, C., Charbonnier, S., & Campagne, A. (2021) · Sensors · doi:10.3390/s21165357 · Cited by 8
“Most of these sensors enable photoplethysmography (PPG), a standard measure of blood volume changes in the skin’s blood vessels [12].”
Background
Metadata
- Authors
- Sinex, J. E.
- Venue
- The American Journal of Emergency Medicine
- Publisher
- Elsevier BV
- Published
- 1999-01
- Volume
- 17
- Issue
- 1
- Pages
- 59-66
- ISSN
- 0735-6757 (ISSN-L)
- OpenAlex
- W2110576716
- Cited by
- 481
- References
- 51
- FWCI
- 4.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.