Factors affecting the accuracy of near-infrared spectroscopy concentration calculations for focal changes in oxygenation parameters
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
MCML—Monte Carlo modeling of light transport in multi-layered tissues
Wang, L., Jacques, S. L., & Zheng, L. (1995) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(95)01640-f · Cited by 3,324
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618
Farrell, T. J., Patterson, M. S., & Wilson, B. (1992) · Medical Physics · doi:10.1118/1.596777 · Cited by 1,378
Boundary conditions for the diffusion equation in radiative transfer
Haskell, R. C., Svaasand, L. O., Tsay, T.-T., Feng, T.-C., Tromberg, B. J., & McAdams, M. S. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.002727 · Cited by 1,138
Functional magnetic resonance imaging of complex human movements
Rao, S. M., Binder, J. R., Bandettini, P. A., Hammeke, T. A., Yetkin, F. Z., Jesmanowicz, A., Lisk, L. M., Morris, G. L., Mueller, W. M., Estkowski, L. D., et al. (1993) · Neurology · doi:10.1212/wnl.43.11.2311 · Cited by 829
Duncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Tyszczuk, L., Cope, M., & Delpy, D. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/2/007 · Cited by 649
Boas, D. A., Culver, J. P., Stott, J. J., & Dunn, A. K. (2002) · Optics Express · doi:10.1364/oe.10.000159 · Cited by 599
Self-citationOkada, E., Firbank, M., Schweiger, M., Arridge, S. R., Cope, M., & Delpy, D. T. (1997) · Applied Optics · doi:10.1364/ao.36.000021 · Cited by 477
Cited by
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
HomER: A review of time-series analysis methods for near-infrared spectroscopy of the brain
Huppert, T. J., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2009) · Applied Optics · doi:10.1364/ao.48.00d280 · Cited by 1,817
Self-citationStrangman, G., Culver, J. P., Thompson, J. H., & Boas, D. A. (2002) · NeuroImage · doi:10.1006/nimg.2002.1227 · Cited by 1,415
Self-citationDiffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
A quantitative comparison of NIRS and fMRI across multiple cognitive tasks
Cui, X., Bray, S., Bryant, D. M., Glover, G. H., & Reiss, A. L. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.069 · Cited by 945
Lloyd-Fox, S., Blasi, A., & Elwell, C. E. (2010) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2009.07.008 · Cited by 865
A temporal comparison of BOLD, ASL, and NIRS hemodynamic responses to motor stimuli in adult humans
Huppert, T. J., Hoge, R. D., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.065 · Cited by 846
Self-citationBoas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
Self-citationThe modified Beer–Lambert law revisited
Kocsis, L., Herman, P., & Eke, A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/5/n02 · Cited by 679
Diffuse correlation spectroscopy for non-invasive, micro-vascular cerebral blood flow measurement
Durduran, T., & Yodh, A. G. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.017 · Cited by 536
Brain–computer interface using a simplified functional near-infrared spectroscopy system
Coyle, S. M., Ward, T. E., & Markham, C. M. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/007 · Cited by 505
Leff, D. R., Orihuela-Espina, F., Elwell, C. E., Athanasiou, T., Delpy, D. T., Darzi, A. W., & Yang, G.-Z. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.058 · Cited by 484
Herold, F., Wiegel, P., Scholkmann, F., & Müller, N. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm7120466 · Cited by 482
Functional near-infrared spectroscopy: current status and future prospects
Hoshi, Y. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804911 · Cited by 468
A wearable multi-channel fNIRS system for brain imaging in freely moving subjects
Piper, S. K., Krueger, A., Koch, S. P., Mehnert, J., Habermehl, C., Steinbrink, J., Obrig, H., & Schmitz, C. H. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.062 · Cited by 463
Scholkmann, F., & Wolf, M. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.10.105004 · Cited by 450
Optical brain imaging in vivo: techniques and applications from animal to man
Hillman, E. M. C. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2789693 · Cited by 436
Cooper, R. J., Selb, J., Gagnon, L., Phillip, D., Schytz, H. W., Iversen, H. K., Ashina, M., & Boas, D. A. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00147 · Cited by 421
“Guided by the values of these parameters applied in previous publications, σ_PCA was varied from 50 to 99.9%, p_Spline was varied from 0 to 1, and α_Wav was varied from 0.01 to 0.8.”
BackgroundMethodInfluentialSelf-citationCerussi, A., Shah, N., Hsiang, D., Durkin, A., Butler, J., & Tromberg, B. J. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2337546 · Cited by 421
Durduran, T., Yu, G., Burnett, M. G., Detre, J. A., Greenberg, J. H., Wang, J., Zhou, C., & Yodh, A. G. (2004) · Optics Letters · doi:10.1364/ol.29.001766 · Cited by 346
Brigadoi, S., & Cooper, R. J. (2015) · Neurophotonics · doi:10.1117/1.nph.2.2.025005 · Cited by 328
Herold, F., Wiegel, P., Scholkmann, F., Thiers, A., Hamacher, D., & Schega, L. (2017) · Neurophotonics · doi:10.1117/1.nph.4.4.041403 · Cited by 314
Infant's brain responses to live and televised action
Shimada, S., & Hiraki, K. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.03.044 · Cited by 292
Dunn, A. K., Devor, A., Dale, A. M., & Boas, D. A. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.04.024 · Cited by 285
Self-citationModified Beer-Lambert law for blood flow
Baker, W. B., Parthasarathy, A. B., Busch, D. R., Mesquita, R. C., Greenberg, J. H., & Yodh, A. G. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.004053 · Cited by 283
Takizawa, R., Kasai, K., Kawakubo, Y., Marumo, K., Kawasaki, S., Yamasue, H., & Fukuda, M. (2008) · Schizophrenia Research · doi:10.1016/j.schres.2007.10.025 · Cited by 283
Gait capacity affects cortical activation patterns related to speed control in the elderly
Harada, T., Miyai, I., Suzuki, M., & Kubota, K. (2009) · Experimental Brain Research · doi:10.1007/s00221-008-1643-y · Cited by 281
Jasdzewski, G., Strangman, G., Wagner, J., Kwong, K. K., Poldrack, R. A., & Boas, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00311-2 · Cited by 277
Self-citationFranceschini, M. A., Fantini, S., Thompson, J. H., Culver, J. P., & Boas, D. A. (2003) · Psychophysiology · doi:10.1111/1469-8986.00057 · Cited by 275
Self-citationNoninvasive measurement of neuronal activity with near-infrared optical imaging
Franceschini, M. A., & Boas, D. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.09.040 · Cited by 244
“…values of the hemoglobin changes are qualitative and not quantitative because we did not consider the partial volume effect, because we used literature values for the DPF, and because we did not take into account possible changes in scattering (Franceschini et al., 2003; Strangman et al., 2003).”
BackgroundMethodSelf-citationEggebrecht, A. T., White, B. R., Ferradal, S. L., Chen, C., Zhan, Y., Snyder, A. Z., Dehghani, H., & Culver, J. P. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.124 · Cited by 239
Towards a standard analysis for functional near-infrared imaging
Schroeter, M. L., Bücheler, M. M., Müller, K., Uludağ, K., Obrig, H., Lohmann, G., Tittgemeyer, M., Villringer, A., & von Cramon, D. Y. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.09.054 · Cited by 231
“Further, partial volume effects might differ between several optode positions (Strangman et al., 2003), which is also not corrected for.”
BackgroundEkkekakis, P. (2009) · Journal of Sport and Exercise Psychology · doi:10.1123/jsep.31.4.505 · Cited by 218
fNIRS in the developmental sciences
Wilcox, T., & Biondi, M. (2015) · WIREs Cognitive Science · doi:10.1002/wcs.1343 · Cited by 214
Gagnon, L., Yücel, M. A., Dehaes, M., Cooper, R. J., Perdue, K. L., Selb, J., Huppert, T. J., Hoge, R. D., & Boas, D. A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.054 · Cited by 214
“Near-infrared spectroscopy (NIRS) (Hillman, 2007; Hoshi, 2007; Villringer et al., 1993) is a non-invasive technique for monitoring the hemodynamic changes occurring in superficial regions of the cortex.”
Self-citationCortical control of normal gait and precision stepping: An fNIRS study
Koenraadt, K. L. M., Roelofsen, E. G. J., Duysens, J., & Keijsers, N. L. W. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.070 · Cited by 206
“…other continuous wave fNIRS issues like differences in optical path length between subjects, interindividual differences in the type and time course of the hemodynamic response, and the absence of absolute measures of the chromophores might have influenced the results (Strangman et al., 2003 ).”
ResultGagnon, L., Yücel, M. A., Boas, D. A., & Cooper, R. J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.01.073 · Cited by 200
Self-citationSex differences in neural and behavioral signatures of cooperation revealed by fNIRS hyperscanning
Baker, J. M., Liu, N., Cui, X., Vrticka, P., Saggar, M., Hosseini, S. M. H., & Reiss, A. L. (2016) · Scientific Reports · doi:10.1038/srep26492 · Cited by 195
Direct measurement of tissue blood flow and metabolism with diffuse optics
Mesquita, R. C., Durduran, T., Yu, G., Buckley, E. M., Kim, M. N., Zhou, C., Choe, R., Sunar, U., & Yodh, A. G. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0232 · Cited by 195
Doi, T., Makizako, H., Shimada, H., Park, H., Tsutsumimoto, K., Uemura, K., & Suzuki, T. (2013) · Aging Clinical and Experimental Research · doi:10.1007/s40520-013-0119-5 · Cited by 180
Can the cerebral metabolic rate of oxygen be estimated with near-infrared spectroscopy?
Boas, D. A., Strangman, G., Culver, J. P., Hoge, R. D., Jasdzewski, G., Poldrack, R. A., Rosen, B. R., & Mandeville, J. B. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/15/311 · Cited by 175
“For further analyses, we used the data from the source–detector pair that exhibited the largest haemodynamic response to activation to minimize cross talk in the estimates of HbR and HbO 2 (Strangman et al 2003).”
MethodInfluentialSelf-citationAssessing infants' cortical response to speech using near-infrared spectroscopy
Bortfeld, H., Wruck, E., & Boas, D. A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.08.010 · Cited by 169
Self-citationStride-time variability and sensorimotor cortical activation during walking
Kurz, M. J., Wilson, T. W., & Arpin, D. J. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.08.084 · Cited by 168
“It should be noted that although we examined deoxyHb responses, our primary focus was on the oxyHb measurements due to their improved signal-to-noise ratios (relative to deoxyHb) and their reduced vulnerability to contamination by factors such as cross talk (Leff et al., 2011; Strangman et al., 2003).”
BackgroundTissue Oxygen Index: Thresholds for Cerebral Ischemia Using Near-Infrared Spectroscopy
Al-Rawi, P. G., & Kirkpatrick, P. J. (2006) · Stroke · doi:10.1161/01.str.0000244807.99073.ae · Cited by 168
Transcranial optical monitoring of cerebrovascular hemodynamics in acute stroke patients
Durduran, T., Zhou, C., Edlow, B. L., Yu, G., Choe, R., Kim, M. N., Cucchiara, B. L., Putt, M. E., Shah, Q., Kasner, S. E., et al. (2009) · Optics Express · doi:10.1364/oe.17.003884 · Cited by 166
“A substantial literature exists on the weaknesses and strengths of this formulation [66,69–72], and experimental tabulations of the differential pathlength factor, DPF, are available for several organs [64,65].”
Quality control and assurance in functional near infrared spectroscopy (fNIRS) experimentation
Orihuela-Espina, F., Leff, D. R., James, D. R. C., Darzi, A. W., & Yang, G. Z. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/13/009 · Cited by 164
“The incorrect separation of chromophore changes is known as cross-talk (Uludag et al 2002, Strangman et al 2003).”
BackgroundZhang, Q., Brown, E. N., & Strangman, G. E. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2754714 · Cited by 163
Self-citationGibson, A., & Dehghani, H. (2009) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2009.0080 · Cited by 159
Shang, Y., Gurley, K., Symons, B., Long, D., Srikuea, R., Crofford, L. J., Peterson, C. A., & Yu, G. (2012) · Arthritis Research & Therapy · doi:10.1186/ar4079 · Cited by 64
“0 cm for leg muscles) to calculate the changes of [HbO2] and [Hb] (that is, Δ[HbO2] and Δ[Hb]) relative to their baselines (before physiological manipulations), based on the modified Beer-Lambert Law [45].”
MethodInfluentialDoes dorsolateral prefrontal cortex (DLPFC) activation return to baseline when sexual stimuli cease?
Leon-Carrion, J., Martín-Rodríguez, J. F., Damas-López, J., Pourrezai, K., Izzetoglu, K., Barroso y Martin, J. M., & Dominguez-Morales, M. R. (2007) · Neuroscience Letters · doi:10.1016/j.neulet.2007.01.058 · Cited by 46
Yu, Q., Zhang, Z., Ludyga, S., Erickson, K. I., Cheval, B., Hou, M., Pindus, D. M., Hillman, C. H., Kramer, A. F., Falck, R. S., et al. (2025) · Advanced Science · doi:10.1002/advs.202406631 · Cited by 27
Cho, S., Kim, W.-S., Park, J., Lee, S. H., Lee, J., Han, C. E., & Paik, N.-J. (2021) · doi:10.1101/2021.04.07.438873 · Cited by 21
“[HbO] levels were only used for analysis because it is more sensitive to the cortical blood flow changes according to the task and deoxyhemoglobin has shown considerable individual differences in task-related changes (Strangman, Franceschini, and Boas 2003).”
MethodCho, S., Chang, W. K., Park, J., Lee, S. H., Lee, J., Han, C. E., Paik, N.-J., & Kim, W.-S. (2022) · Scientific Reports · doi:10.1038/s41598-022-04771-5 · Cited by 21
Metadata
- Authors
- Strangman, G., Franceschini, M. A., & Boas, D. A.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2003-04
- Volume
- 18
- Issue
- 4
- Pages
- 865-879
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2132458261
- Cited by
- 581
- References
- 41
- FWCI
- 14.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.