Quantification using real-time PCR technology: applications and limitations
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heid, C. A., Stevens, J., Livak, K. J., & Williams, P. M. (1996) · Genome Research · doi:10.1101/gr.6.10.986 · Cited by 6,174
Molecular Beacons: Probes that Fluoresce upon Hybridization
Tyagi, S., & Kramer, F. R. (1996) · Nature Biotechnology · doi:10.1038/nbt0396-303 · Cited by 4,155
Bustin, S. (2000) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0250169 · Cited by 3,872
A novel method for real time quantitative RT-PCR.
Gibson, U. E., Heid, C. A., & Williams, P. M. (1996) · Genome Research · doi:10.1101/gr.6.10.995 · Cited by 2,075
Multicolor molecular beacons for allele discrimination
Tyagi, S., Bratu, D. P., & Kramer, F. R. (1998) · Nature Biotechnology · doi:10.1038/nbt0198-49 · Cited by 1,320
Continuous Fluorescence Monitoring of Rapid Cycle DNA Amplification
Wittwer, C. T., Herrmann, M. G., Moss, A. A., & Rasmussen, R. P. (2013) · BioTechniques · doi:10.2144/000114043 · Cited by 1,274
Continuous Fluorescence Monitoring of Rapid Cycle DNA Amplification
Wittwer, C. T., Herrmann, M. G., Moss, A. A., & Rasmussen, R. P. (1997) · BioTechniques · doi:10.2144/97221bi01 · Cited by 1,143
Paradis, K., Langford, G., Long, Z., Heneine, W., Sandstrom, P., Switzer, W. M., Chapman, L. E., Lockey, C., Onions, D., The XEN 111 Study Group, et al. (1999) · Science · doi:10.1126/science.285.5431.1236 · Cited by 729
Detection of PCR products using self-probing amplicons and fluorescence
Whitcombe, D., Theaker, J., Guy, S. P., Brown, T., & Little, S. (1999) · Nature Biotechnology · doi:10.1038/11751 · Cited by 697
PCR Detection of Bacteria in Seven Minutes
Belgrader, P., Benett, W., Hadley, D., Richards, J., Stratton, P., Mariella, R., & Milanovich, F. (1999) · Science · doi:10.1126/science.284.5413.449 · Cited by 357
Cited by
Statistical analysis of real-time PCR data
Yuan, J. S., Reed, A., Chen, F., & Stewart, C. N. (2006) · BMC Bioinformatics · doi:10.1186/1471-2105-7-85 · Cited by 2,195
Comprehensive Algorithm for Quantitative Real-Time Polymerase Chain Reaction
Zhao, S., & Fernald, R. D. (2005) · Journal of Computational Biology · doi:10.1089/cmb.2005.12.1047 · Cited by 1,303
A Basic Guide to Real Time PCR in Microbial Diagnostics: Definitions, Parameters, and Everything
Kralik, P., & Ricchi, M. (2017) · Frontiers in Microbiology · doi:10.3389/fmicb.2017.00108 · Cited by 927
Electrochemical biosensors for pathogen detection
Cesewski, E., & Johnson, B. N. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112214 · Cited by 902
Peirson, S. N. (2003) · Nucleic Acids Research · doi:10.1093/nar/gng073 · Cited by 843
Real-time PCR in the microbiology laboratory
Mackay, I. M. (2004) · Clinical Microbiology and Infection · doi:10.1111/j.1198-743x.2004.00722.x · Cited by 807
Absolute and relative QPCR quantification of plasmid copy number in Escherichia coli
Lee, C., Kim, J., Shin, S. G., & Hwang, S. (2006) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2005.11.014 · Cited by 644
Valasek, M. A., & Repa, J. J. (2005) · Advances in Physiology Education · doi:10.1152/advan.00019.2005 · Cited by 574
Laboratory Diagnostic Techniques for Entamoeba Species
Fotedar, R., Stark, D., Beebe, N., Marriott, D., Ellis, J., & Harkness, J. (2007) · Clinical Microbiology Reviews · doi:10.1128/cmr.00004-07 · Cited by 489
Standardized determination of real-time PCR efficiency from a single reaction set-up
Tichopad, A. (2003) · Nucleic Acids Research · doi:10.1093/nar/gng122 · Cited by 455
ddPCR: a more accurate tool for SARS-CoV-2 detection in low viral load specimens
Suo, T., Liu, X., Feng, J., Guo, M., Hu, W., Guo, D., Ullah, H., Yang, Y., Zhang, Q., Wang, X., et al. (2020) · Emerging Microbes & Infections · doi:10.1080/22221751.2020.1772678 · Cited by 450
Verweij, J. J., Blangé, R. A., Templeton, K., Schinkel, J., Brienen, E. A. T., van Rooyen, M. A. A., van Lieshout, L., & Polderman, A. M. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.3.1220-1223.2004 · Cited by 412
Properties of the Reverse Transcription Reaction in mRNA Quantification
Ståhlberg, A., Håkansson, J., Xian, X., Semb, H., & Kubista, M. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.026161 · Cited by 409
“dynamic range of reverse transcription QPCR analysis has in several studies been shown to have a large dynamic range (17, 18).”
Why the need for qPCR publication guidelines?—The case for MIQE
Bustin, S. A. (2010) · Methods · doi:10.1016/j.ymeth.2009.12.006 · Cited by 375
Dallas, P. B., Gottardo, N. G., Firth, M. J., Beesley, A. H., Hoffmann, K., Terry, P. A., Freitas, J. R., Boag, J. M., Cummings, A. J., & Kees, U. R. (2005) · BMC Genomics · doi:10.1186/1471-2164-6-59 · Cited by 341
Zhang, T., & Fang, H. H. P. (2006) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-006-0333-6 · Cited by 277
Rodríguez-Lázaro, D., Hernández, M., Scortti, M., Esteve, T., Vázquez-Boland, J. A., & Pla, M. (2004) · Applied and Environmental Microbiology · doi:10.1128/aem.70.3.1366-1377.2004 · Cited by 246
Statistical methods for efficiency adjusted real‐time PCR quantification
Yuan, J. S., Wang, D., & Stewart, C. N. (2008) · Biotechnology Journal · doi:10.1002/biot.200700169 · Cited by 245
“Even though real-time PCR has become one of the most important enabling technologies in the genomic era, the real or perceived unreliability of real-time PCR data has engendered serious concerns [1, 4].”
Isothermal Amplification of Nucleic Acids: The Race for the Next “Gold Standard”
Oliveira, B. B., Veigas, B., & Baptista, P. V. (2021) · Frontiers in Sensors · doi:10.3389/fsens.2021.752600 · Cited by 235
“…such as recognition and identification of infectious pathogens, characterization of genetic disorders, identification of disease biomarkers, gene expression studies, sample preparation for downstream applications and techniques (e.g., sequencing, labelling, etc.), among many others (Klein 2002).”
Verweij, J. J., & Stensvold, C. R. (2014) · Clinical Microbiology Reviews · doi:10.1128/cmr.00122-13 · Cited by 229
“asiatica Multiplex PCR Gel electrophoresis cox1 Proglottids, stool (6) 533”
Hou, Y., Zhang, H., Miranda, L., & Lin, S. (2010) · PLoS ONE · doi:10.1371/journal.pone.0009545 · Cited by 222
Verweij, J. J., Brienen, E. A. T., Ziem, J., Yelifari, L., Polderman, A. M., & Van Lieshout, L. (2007) · The American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2007.77.685 · Cited by 219
Rutledge, R. G. (2004) · Nucleic Acids Research · doi:10.1093/nar/gnh177 · Cited by 209
Three-Mode Electrochemical Sensing of Ultralow MicroRNA Levels
Labib, M., Khan, N., Ghobadloo, S. M., Cheng, J., Pezacki, J. P., & Berezovski, M. V. (2013) · Journal of the American Chemical Society · doi:10.1021/ja308216z · Cited by 206
Tajadini, M., Panjehpour, M., & Javanmard, S. (2014) · Advanced Biomedical Research · doi:10.4103/2277-9175.127998 · Cited by 201
“[19,20] They recorded PCR reaction containing ethidium bromide (EtBr) dye under ultraviolet light by video camera.”
Hao, X., Horvath, D., Chao, W., Yang, Y., Wang, X., & Xiao, B. (2014) · International Journal of Molecular Sciences · doi:10.3390/ijms151222155 · Cited by 190
“Quantitative real-time polymerase chain reaction (qRT-PCR) has become a critical tool for rapid and reliable quantification of gene transcript levels due to its simplicity, specificity, and sensitivity [1–3].”
Charlton, C. L., Babady, E., Ginocchio, C. C., Hatchette, T. F., Jerris, R. C., Li, Y., Loeffelholz, M., McCarter, Y. S., Miller, M. B., Novak-Weekley, S., et al. (2018) · Clinical Microbiology Reviews · doi:10.1128/cmr.00042-18 · Cited by 188
Graphene biosensors for bacterial and viral pathogens
Jiang, Z., Feng, B., Xu, J., Qing, T., Zhang, P., & Qing, Z. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112471 · Cited by 188
“Traditional pathogen analysis techniques such as polymerase chain reaction (PCR) (Klein, 2002) and enzyme-linked immunosorbent assay (ELISA) (Law et al., 2015) are highly sensitive and durable.”
Atienzar, F. A., Venier, P., Jha, A. N., & Depledge, M. H. (2002) · Mutation Research/Genetic Toxicology and Environmental Mutagenesis · doi:10.1016/s1383-5718(02)00216-4 · Cited by 184
Kim, H., Bae, H.-S., Reddy, K. R., & Ogram, A. (2016) · Water Research · doi:10.1016/j.watres.2016.09.048 · Cited by 177
Kim, J., Lim, J., & Lee, C. (2013) · Biotechnology Advances · doi:10.1016/j.biotechadv.2013.05.010 · Cited by 172
“…for studying microbial ecology in complex ecosystems, including wastewater treatment processes, due to its wide quantification range (>6 orders of magnitude), high reproducibility (b2% standard deviation), high sensitivity (b5 copies), and high specificity (Klein, 2002; Valasek and Repa, 2005).”
BackgroundMethodInfluentialWu, J.-L., Tseng, W.-P., Lin, C.-H., Lee, T.-F., Chung, M.-Y., Huang, C.-H., Chen, S.-Y., Hsueh, P.-R., & Chen, S.-C. (2020) · Journal of Infection · doi:10.1016/j.jinf.2020.06.023 · Cited by 172
Tuomi, J. M., Voorbraak, F., Jones, D. L., & Ruijter, J. M. (2010) · Methods · doi:10.1016/j.ymeth.2010.02.003 · Cited by 167
Microbiology of diabetic foot infections: from Louis Pasteur to ‘crime scene investigation’
Spichler, A., Hurwitz, B. L., Armstrong, D. G., & Lipsky, B. A. (2015) · BMC Medicine · doi:10.1186/s12916-014-0232-0 · Cited by 163
“Overall, diagnostic tests based on PCR are subject to issues related to detection sensitivity and specificity, which may lead to an inaccurate portrayal of bacterial communities in wounds [56-58].”
Real-time, fluorescence-based quantitative PCR: a snapshot of current procedures and preferences
Bustin, S. A. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.4.493 · Cited by 144
GnRH and its receptor (GnRH-R) are expressed in the canine placenta and uterus
Schäfer-Somi, S., Kowalewski, M. P., Kanca, H., Bozkurt, M. F., Gram, A., Sabitzer, S., Kucukaslan, I., Ay, S. S., & Aslan, S. (2015) · Theriogenology · doi:10.1016/j.theriogenology.2015.07.034 · Cited by 12
Effects of Fructose on Features of Steatotic Liver Disease in HepG2 Cells
Howes, M. T., King, J., & Rosengren, R. J. (2025) · Nutrients · doi:10.3390/nu17172762 · Cited by 5
“…no phenotypic effect was seen in TG accumulation. qPCR assays are the gold standard for detecting changes in the expression level of genes of interest [40]. qPCR was selected over Western blotting to investigate the expression levels of transcription factors and enzymes of interest related to DNL.”
Böllmann, J., & Martienssen, M. (2024) · Microorganisms · doi:10.3390/microorganisms12030511 · Cited by 3
Schmitt, A., Rex, M., Ebert, S., Friedt, W., Töpfer, R., & Zyprian, E. (2010) · Methodologies and Results in Grapevine Research · doi:10.1007/978-90-481-9283-0_27 · Cited by 2
“With appropriate internal standards and calculations, mean variation coefficients are 1–2%, allowing reproducible analysis of subtle gene expression changes even at low levels of transcription ( Klein 2002, Luu-The et al. 2005).”
Metadata
- Authors
- Klein, D.
- Venue
- Trends in Molecular Medicine
- Publisher
- Elsevier BV
- Published
- 2002-06
- Volume
- 8
- Issue
- 6
- Pages
- 257-260
- ISSN
- 1471-4914 (ISSN-L)
- OpenAlex
- W2069797500
- Cited by
- 762
- References
- 16
- FWCI
- 8.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.