The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Microfluidic Device for Single-Cell Analysis
Abstract
We have developed a novel microfluidic device constructed from poly(dimethylsiloxane) using multilayer soft lithography technology for the analysis of single cells. The microfluidic network enables the passive and gentle separation of a single cell from the bulk cell suspension, and integrated valves and pumps enable the precise delivery of nanoliter volumes of reagents to that cell. Various applications are demonstrated, including cell viability assays, ionophore-mediated intracellular Ca2+ flux measurements, and multistep receptor-mediated Ca2+ measurements. These assays, and others, are achieved with significant improvements in reagent consumption, analysis time, and temporal resolution over macroscale alternatives.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Todaro, G. J., & Green, H. (1963) · The Journal of Cell Biology · doi:10.1083/jcb.17.2.299 · Cited by 2,736
Establishment and characterization of a human histiocytic lymphoma cell line (U‐937)
Sundström, C., & Nilsson, K. (1976) · International Journal of Cancer · doi:10.1002/ijc.2910170504 · Cited by 2,407
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Micro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,191
Ravetch, J. V., & Bolland, S. (2001) · Annual Review of Immunology · doi:10.1146/annurev.immunol.19.1.275 · Cited by 1,657
From Micro- to Nanofabrication with Soft Materials
Quake, S. R., & Scherer, A. (2000) · Science · doi:10.1126/science.290.5496.1536 · Cited by 1,131
Microfabricating Conjugated Polymer Actuators
Jager, E. W. H., Smela, E., & Inganäs, O. (2000) · Science · doi:10.1126/science.290.5496.1540 · Cited by 962
Self-Assembly of Highly Phosphorylated Silaffins and Their Function in Biosilica Morphogenesis
Kröger, N., Lorenz, S., Brunner, E., & Sumper, M. (2002) · Science · doi:10.1126/science.1076221 · Cited by 792
Measurement of Intracellular Calcium
Takahashi, A., Camacho, P., Lechleiter, J. D., & Herman, B. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.4.1089 · Cited by 763
Cited by
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Buettner, F., Natarajan, K. N., Casale, F. P., Proserpio, V., Scialdone, A., Theis, F. J., Teichmann, S. A., Marioni, J. C., & Stegle, O. (2015) · Nature Biotechnology · doi:10.1038/nbt.3102 · Cited by 1,136
Microfluidics for in vivo imaging of neuronal and behavioral activity in Caenorhabditis elegans
Chronis, N., Zimmer, M., & Bargmann, C. I. (2007) · Nature Methods · doi:10.1038/nmeth1075 · Cited by 594
Localized Surface Plasmon Resonance Biosensors
Zhao, J., Zhang, X., Yonzon, C. R., Haes, A. J., & Van Duyne, R. P. (2006) · Nanomedicine · doi:10.2217/17435889.1.2.219 · Cited by 508
Large-Scale Single-Cell Trapping And Imaging Using Microwell Arrays
Rettig, J. R., & Folch, A. (2005) · Analytical Chemistry · doi:10.1021/ac0505977 · Cited by 502
Microfluidics technology for manipulation and analysis of biological cells
Yi, C., Li, C.-W., Ji, S., & Yang, M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.037 · Cited by 478
Di Carlo, D., Aghdam, N., & Lee, L. P. (2006) · Analytical Chemistry · doi:10.1021/ac060541s · Cited by 458
High-throughput microfluidic single-cell RT-qPCR
White, A. K., VanInsberghe, M., Petriv, O. I., Hamidi, M., Sikorski, D., Marra, M. A., Piret, J., Aparicio, S., & Hansen, C. L. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1019446108 · Cited by 440
Computerized microfluidic cell culture using elastomeric channels and Braille displays
Gu, W., Zhu, X., Futai, N., Cho, B. S., & Takayama, S. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0404353101 · Cited by 403
Microfluidics for flow cytometric analysis of cells and particles
Huh, D., Gu, W., Kamotani, Y., Grotberg, J. B., & Takayama, S. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/3/r02 · Cited by 396
Microenvironment design considerations for cellular scale studies
Walker, G. M., Zeringue, H. C., & Beebe, D. J. (2004) · Lab on a Chip · doi:10.1039/b311214d · Cited by 388
Super‐Hydrophobic PDMS Surface with Ultra‐Low Adhesive Force
Jin, M., Feng, X., Xi, J., Zhai, J., Cho, K., Feng, L., & Jiang, L. (2005) · Macromolecular Rapid Communications · doi:10.1002/marc.200500458 · Cited by 373
Recent Advances in Analytical Chemistry by 3D Printing
Gross, B., Lockwood, S. Y., & Spence, D. M. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04344 · Cited by 359
Digital microfluidics for cell-based assays
Barbulovic-Nad, I., Yang, H., Park, P. S., & Wheeler, A. R. (2008) · Lab on a Chip · doi:10.1039/b717759c · Cited by 337
Self-citationIntegration of GC–MS and LC–MS for untargeted metabolomics profiling
Zeki, Ö. C., Eylem, C. C., Reçber, T., Kır, S., & Nemutlu, E. (2020) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2020.113509 · Cited by 336
Gao, J., Yin, X.-F., & Fang, Z.-L. (2004) · Lab on a Chip · doi:10.1039/b310552k · Cited by 300
Overview of single-cell analyses: microdevices and applications
Lindström, S., & Andersson-Svahn, H. (2010) · Lab on a Chip · doi:10.1039/c0lc00150c · Cited by 260
McDade, J. K., Brennan-Pierce, E. P., Ariganello, M. B., Labow, R. S., & Michael Lee, J. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.02.021 · Cited by 80
Metadata
- Authors
- Wheeler, A. R., Throndset, W. R., Whelan, R. J., Leach, A. M., Zare, R. N., Liao, Y. H., Farrell, K., Manger, I. D., & Daridon, A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-05-14
- Volume
- 75
- Issue
- 14
- Pages
- 3581-3586
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2036758684
- Cited by
- 600
- References
- 25
- FWCI
- 27.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.