Cited by 88Advanced Proteomics Techniques and ApplicationsMass Spectrometry Techniques and ApplicationsMetabolomics and Mass Spectrometry Studies

Advancing Top-down Analysis of the Human Proteome Using a Benchtop Quadrupole-Orbitrap Mass Spectrometer

Open access
Fornelli, Luca, Durbin, Kenneth R., Fellers, Ryan T., Early, Bryan P., Greer, Joseph B., LeDuc, Richard D., Compton, Philip D., Kelleher, Neil L.·2017·Journal of Proteome Research

Abstract

Over the past decade, developments in high resolution mass spectrometry have enabled the high throughput analysis of intact proteins from complex proteomes, leading to the identification of thousands of proteoforms. Several previous reports on top-down proteomics (TDP) relied on hybrid ion trap-Fourier transform mass spectrometers combined with data-dependent acquisition strategies. To further reduce TDP to practice, we use a quadrupole-Orbitrap instrument coupled with software for proteoform-dependent data acquisition to identify and characterize nearly 2000 proteoforms at a 1% false discovery rate from human fibroblasts. By combining a 3 m/z isolation window with short transients to improve specificity and signal-to-noise for proteoforms >30 kDa, we demonstrate improving proteome coverage by capturing 439 proteoforms in the 30-60 kDa range. Three different data acquisition strategies were compared and resulted in the identification of many proteoforms not observed in replicate data-dependent experiments. Notably, the data set is reported with updated metrics and tools including a new viewer and assignment of permanent proteoform record identifiers for inclusion of highly characterized proteoforms (i.e., those with C-scores >40) in a repository curated by the Consortium for Top-Down Proteomics.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.jproteome.6b00698

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Benchtop Orbitrap mass spectrometers are the most common instrument for proteomics, bypass cryogenic cooling, and offer high resolution and faster acquisition.

    “Currently, benchtop Orbitrap mass spectrometers are the most common instrument for proteomics as they bypass the need for cryogenic cooling (which is needed for the magnets of FTICR instruments) while still offering high-resolution and faster acquisition speeds [98,99].”
  • Tuning Orbitrap instrument parameters by the Brodbelt and Kelleher group increased its scope for targeted and global analysis of larger proteoforms.

    “Work by the Brodbelt and Kelleher group in tuning the Orbitrap instrument parameters has increased its scope for targeted and global analysis of larger proteoforms [98,102].”
  • HCD was used when the med/hi strategy was originally developed to investigate 30-60 kDa proteoforms because it was the only ion activation technique available on a Q Exactive mass spectrometer.

    “HCD was used when the med/hi strategy was originally developed to investigate 30–60 kDa proteoforms as it was the only ion activation technique available on a Q Exactive mass spectrometer.23”
  • The medium/high DDA method collects MS1 spectra by averaging 10-15 short transients before Fourier transform, improving S/N at the cost of resolving power and yielding average rather than monoisotopic proteoform masses.

    “broadband spectra (MS1) are collected by averaging a large number (i.e., 10–15) of short time-domain transients (i.e., microscans) prior to Fourier transform. In this way, the S/N of MS1 spectra is substantially improved at the expense of resolving power, with the resulting non-isotopically resolved spectra leading to the determination of an average proteoform mass rather than the monoisotopic one”
  • The 850-900 m/z window center was chosen because previous experimental data showed that the highest intensity charge states for most nanoflow electrospray-ionized proteins localize in that m/z region.

    “The 850–900 m/z window center was selected for tPTCR runs based on the analysis of experimental data from previous studies23 that showed that the highest intensity charge states for most proteins ionized by nanoflow electrospray were localized in that m/z region.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Fornelli, L., Durbin, K. R., Fellers, R. T., Early, B. P., Greer, J. B., LeDuc, R. D., Compton, P. D., & Kelleher, N. L.
Affiliations
Northwestern University (US)
Corresponding author
Kelleher, Neil L.
Venue
Journal of Proteome Research
Published
2016-12-02
Volume
16
Issue
2
Pages
609-618
ISSN
  • 1535-3893 (ISSN-L)
  • 1535-3907
OpenAlex
W2508035970
Cited by
88
References
46
Citations by year
2026: 3 · 2025: 10 · 2024: 5 · 2023: 3 · 2022: 10 · 2021: 11 · 2020: 10 · 2019: 11 · 2018: 16 · 2017: 8 · 2015: 1
FWCI
5.81
Type
journal article
Language
en
Open access
Locations
  • Journal of Proteome Research (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
  • IUScholarWorks (Indiana University) (submittedVersion, cc-by)
Funders
  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
  • National Institute of General Medical Sciences (GM067193, P41 GM108569)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
Keywords
top-down proteomics, proteoforms, human proteome, data-dependent acquisition, human fibroblasts, proteoform identification, C-score, false discovery rate
MeSH terms
Fibroblasts, Humans, Software, Mass Spectrometry, Proteome, Proteomics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review