CoChat

Integrated Microfluidic Capillary Electrophoresis-Electrospray Ionization Devices with Online MS Detection for the Separation and Characterization of Intact Monoclonal Antibody Variants

The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.

Abstract

Here, we demonstrate an integrated microfluidic capillary electrophoresis-electrospray ionization (CE-ESI) device for the separation of intact monoclonal antibody charge variants with online mass spectrometric (MS) identification. The need for dynamic coating and zwitterionic background electrolyte (BGE) additives has been eliminated by utilizing surface chemistry within the device channels to control analyte adsorption and electroosmotic flow (EOF) while maintaining separation efficiency. The effectiveness of this strategy was illustrated with the separation of charge variants of Infliximab. Three major species corresponding to C-terminal lysine variants were separated with an average resolution of 0.80 and identified by mass difference. In addition to the lysine variants, masses were determined for minor acidic and basic species. The separation of these variants prior to MS analysis facilitated the identification of glycosylation patterns for each of the variants. The general applicability of this method was demonstrated by analyzing two additional monoclonal antibody species: an IgG2 antibody and an IgG1 antibody conjugate. The IgG2 proved to have similar modifications to Infliximab with lower relative abundances of the lysine variants. Analysis of the IgG1 drug conjugate further exemplified the advantages of MS detection; differences in the extent of antibody conjugation were detectable despite limited CE resolution. The CE-ESI-MS methodology described here is a rapid and generic strategy for the separation of intact mAb charge variants and facilitates the identification of variants through MS detection.

Overview

Integrity signals

Registry

Crossref · 10.1021/ac503964j

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 3

  1. Haselberg R., 2013, Anal. Biochem., 85, 2289
  2. Berger S. J., 2008, Efficiently Comparing Batches of an Intact Monoclonal Antibody Using the Biopharmalynx Software Package
  3. Shion H., 2013, Structural Comparison of Infliximab and a Biosimilar via Subunit Analysis Using the Waters Biopharmaceutical Platform with UNIFI

Cited by

See all 137

Metadata

Authors
Redman, E. A., Batz, N. G., Mellors, J. S., & Ramsey, J. M.
Affiliations
University of North Carolina at Chapel Hill (US)
Corresponding author
Ramsey, J. Michael
Venue
Analytical Chemistry
Published
2015-01-29
Volume
87
Issue
4
Pages
2264-2272
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2315996892
Cited by
136
References
46
Citations by year
2026: 6 · 2025: 5 · 2024: 8 · 2023: 11 · 2022: 11 · 2021: 15 · 2020: 14 · 2019: 13 · 2018: 13 · 2017: 19 · 2016: 17 · 2015: 4
FWCI
8.79
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Center for Biomedical Microdevices, University of North Carolina, Chapel Hill
  • National Institute of General Medical Sciences (5R01GM066018-11)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Life Sciences › Immunology and Microbiology › Immunology › Biosimilars and Bioanalytical Methods
Keywords
microfluidic capillary electrophoresis, infliximab, glycosylation patterns, electroosmotic flow control, surface chemistry, IgG2 antibodies, antibody conjugates, on-line mass spectrometry
MeSH terms
Immunoglobulin G, Electrophoresis, Capillary, Spectrometry, Mass, Electrospray Ionization, Microfluidic Analytical Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.