Potential Stability of All-Solid-State Ion-Selective Electrodes Using Conducting Polymers as Ion-to-Electron Transducers
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Demanding analytical applications such as on-line process analysis and clinical analysis require robust, reliable, and maintenance-free ion sensors of high potential stability. In this work the stability of the electrode potential of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers is critically evaluated by using chronopotentiometry and electrochemical impedance spectroscopy. This study is focused on the relationship between the potential stability of the electrode and the capacitance of the solid contact where ion-to-electron transduction takes place. The influence of this capacitance on the potential stability of all-solid-state ion-selective electrodes is studied experimentally by using conducting polymer layers of different thickness as solid contacts in potassium ion-selective electrodes based on a solvent polymeric membrane. Because of its excellent environmental stability, the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) is used as a model compound for the solid contact material. Chronopotentiometry is found to be a convenient and fast experimental method to critically evaluate the potential stability of different types of ion-selective electrodes.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Also, the high impedance nature of the ISE-based sensors37 required the use of high-impedance voltage buffers to ensure accurate open voltage measurement as intended.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [37]
Citations
Cites
Handbook of conducting polymers
Skotheim, T. A., Elsenbaumer, R. L., & Reynolds, J. R. (1986) · M. Dekker eBooks · Cited by 8,079
Poly(alkylenedioxythiophene)s—new, very stable conducting polymers
Heywang, G., & Jonas, F. (1992) · Advanced Materials · doi:10.1002/adma.19920040213 · Cited by 1,027
Cadogan, A., Gao, Z., Lewenstam, A., Ivaska, A., & Diamond, D. (1992) · Analytical Chemistry · doi:10.1021/ac00045a007 · Cited by 428
Coated wire ion-selective electrodes
Cattrall, R. W., & Freiser, H. (1971) · Analytical Chemistry · doi:10.1021/ac60307a032 · Cited by 387
Horvai, G., Graf, E., Toth, K., Pungor, E., & Buck, R. P. (1986) · Analytical Chemistry · doi:10.1021/ac00126a034 · Cited by 235
GUSTAFSSON, J., LIEDBERG, B., & INGANAS, O. (1994) · Solid State Ionics · doi:10.1016/0167-2738(94)90403-0 · Cited by 213
Technical applications for conductive polymers
Jonas, F., & Heywang, G. (1994) · Electrochimica Acta · doi:10.1016/0013-4686(94)e0057-7 · Cited by 202
Single-piece all-solid-state ion-selective electrode
Bobacka, J., Lindfors, T., McCarrick, M., Ivaska, A., & Lewenstam, A. (1995) · Analytical Chemistry · doi:10.1021/ac00116a034 · Cited by 188
Self-citationBobacka, J., McCarrick, M., Lewenstam, A., & Ivaska, A. (1994) · The Analyst · doi:10.1039/an9941901985 · Cited by 175
Self-citationCharacterization of electroactive polymer layers by electrochemical impedance spectroscopy (EIS)
Musiani, M. M. (1990) · Electrochimica Acta · doi:10.1016/0013-4686(90)80023-h · Cited by 148
Research works printed but not linked: 7
- Nikolskii B. P., 1985, Ion-Sel. Electrode Rev., 7, 39
- Buck R. P., 1976, Anal. Chem., 48, 39R
- Momma T., 1995, Sens. Acuators, B, 24, 728
- Pandey P. C., 1998, Sens. Actuators, B, 46, 65
- Glarum S. H., 1987, J. Electrochem. Soc., 134, 147
- Bobacka J., 1991, Synth. Met., 44, 34
- Koryta, J.; Dvorak, J.; Kavan, L. Principles of Electrochemistry , 2nd ed.; Wiley: Chichester, U.K., 1993; p 38.
Cited by
Items 101–200 of 686
All-solid-state potentiometric sensor using single-walled carbon nanohorns as transducer
Jiang, C., Yao, Y., Cai, Y., & Ping, J. F. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.12.040 · Cited by 75
Ion-selective electrodes with superhydrophobic polymer/carbon nanocomposites as solid contact
Paczosa‐Bator, B. (2015) · Carbon · doi:10.1016/j.carbon.2015.09.006 · Cited by 74
Mattinen, U., & Bobacka, J. (2014) · Analytical Chemistry · doi:10.1021/ac501464s · Cited by 73
Self-citationZanganeh, A. R., & Amini, M. K. (2006) · Electrochimica Acta · doi:10.1016/j.electacta.2006.10.055 · Cited by 72
An Integrated Paper-Based Microfluidic Device for Real-Time Sweat Potassium Monitoring
Liang, B., Cao, Q., Mao, X., Pan, W., Tu, T., Lü, F., & Ye, X. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3009327 · Cited by 75
“Reference [25] Then, 2 μL ion-selective solutions were dripped on the working electrode with a pipette gun, and the 2 μL reference electrode solution was dripped on the reference electrode 3 times.”
MethodYin, T., Pan, D., & Qin, W. (2014) · Analytical Chemistry · doi:10.1021/ac5029209 · Cited by 71
Qi, L., Jiang, T., Liang, R., & Qin, W. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.129014 · Cited by 72
“A poly(3, 4-ethylenedioxythiophene) : poly(sodium 4-styrenesulfonate) (PEDOT : PSS) layer was used as the intermediate layer of the solid-contact K-ISE [38,39].”
MethodNext-Generation Potentiometric Sensors: A Review of Flexible and Wearable Technologies
Fathy, M. A., & Bühlmann, P. (2025) · Biosensors · doi:10.3390/bios15010051 · Cited by 82
Solid-contact pH-selective electrode using multi-walled carbon nanotubes
Crespo, G. A., Gugsa, D., Macho, S., & Rius, F. X. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3127-8 · Cited by 70
High-performance flexible potentiometric sensing devices using free-standing graphene paper
Ping, J. F., Wang, Y., Fan, K., Tang, W., Wu, J. F., & Ying, Y. B. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb20664e · Cited by 70
Khorasani, J. H., Amini, M. K., Motaghi, H., Tangestaninejad, S., & Moghadam, M. (2002) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(02)00294-0 · Cited by 69
Zhou, M., Gan, S., Cai, B., Li, F., Ma, W., Han, D., & Niu, L. (2012) · Analytical Chemistry · doi:10.1021/ac300473a · Cited by 68
PEDOT films: multifunctional membranes for electrochemical ion sensing
Michalska, A., Galuszkiewicz, A., Ogonowska, M., Ocypa, M., & Maksymiuk, K. (2004) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-003-0459-8 · Cited by 68
Lindfors, T., & Ivaska, A. U. (2001) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)00996-5 · Cited by 67
Jiang, X., Wang, P., Liang, R., & Qin, W. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b00039 · Cited by 66
Lowering the Resistivity of Polyacrylate Ion-Selective Membranes by Platinum Nanoparticles Addition
Jaworska, E., Kisiel, A., Maksymiuk, K., & Michalska, A. (2010) · Analytical Chemistry · doi:10.1021/ac1019864 · Cited by 66
Lindfors, T., Höfler, L., Jágerszki, G., & Gyurcsányi, R. E. (2011) · Analytical Chemistry · doi:10.1021/ac200597b · Cited by 66
All-solid-state nitrate-selective electrode and its application in drinking water
Tang, W., Ping, J. F., Fan, K., Wang, Y., Luo, X. G., Ying, Y. B., Wu, J. F., & Zhou, Q. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.07.073 · Cited by 65
Equilibration Time of Solid Contact Ion-Selective Electrodes
Guziński, M., Jarvis, J. M., Pendley, B. D., & Lindner, E. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00775 · Cited by 64
Kim, M.-Y., Lee, J., Park, D. J., Lee, J., Myung, N. V., Kwon, S., & Lee, K. H. (2021) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2021.115553 · Cited by 66
Bobacka, J., Lewenstam, A., & Ivaska, A. U. (2001) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(00)00515-5 · Cited by 62
Self-citationEl‐Rahman, M. K. A., Rezk, M. R., Mahmoud, A. M., & Elghobashy, M. R. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.11.009 · Cited by 62
Kamel, A. H., Jiang, X., Li, P., & Liang, R. (2018) · Analytical Methods · doi:10.1039/c8ay01229f · Cited by 61
Pięk, M., Piech, R., & Paczosa‐Bator, B. (2016) · Electrochimica Acta · doi:10.1016/j.electacta.2016.05.170 · Cited by 61
Ferrocene Bound Poly(vinyl chloride) as Ion to Electron Transducer in Electrochemical Ion Sensors
Pawlak, M., Grygołowicz‐Pawlak, E., & Bakker, E. (2010) · Analytical Chemistry · doi:10.1021/ac1010662 · Cited by 60
Electrolysis‐reducing electrodes for electrokinetic devices
Erlandsson, P. G., & Robinson, N. D. (2011) · Electrophoresis · doi:10.1002/elps.201000617 · Cited by 60
A Printed Organic Circuit System for Wearable Amperometric Electrochemical Sensors
Shiwaku, R., Matsui, H., Nagamine, K., Uematsu, M., Mano, T., Maruyama, Y., Nomura, A., Tsuchiya, K., Hayasaka, K., Takeda, Y., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-24744-x · Cited by 65
Veder, J., MARCO, R. D., Patel, K., Si, P., Grygołowicz‐Pawlak, E., James, M., Alam, M. T., Sohail, M., Lee, J., Pretsch, E., et al. (2013) · Analytical Chemistry · doi:10.1021/ac4024999 · Cited by 59
Ion-Selective Electrodes for Detection of Lead (II) in Drinking Water: A Mini-Review
Tang, X., Wang, P.-Y., & Buchter, G. (2018) · Environments · doi:10.3390/environments5090095 · Cited by 67
Microcavity Based Solid‐Contact Ion‐Selective Microelectrodes
Sundfors, F., Bereczki, R., Bobacka, J., Tóth, K., Ivaska, A. U., & Gyurcsányi, R. E. (2006) · Electroanalysis · doi:10.1002/elan.200603541 · Cited by 59
Self-citationÖzer, T., Ağır, İ., & Henry, C. S. (2022) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2022.131961 · Cited by 60
Single-piece solid-contact ion-selective electrodes with polymer–carbon nanotube composites
Zhu, J., Li, X., Qin, Y., & Zhang, Y. (2010) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2010.04.041 · Cited by 60
Zeng, X., Yu, S., Yuan, Q., & Qin, W. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.04.153 · Cited by 58
“Consequently, intermediate layers working as ion-to-electron ransducers have been proposed, which promotes the development f solid-contact ion selective electrodes (SC-ISEs) [3].”
BackgroundMousavi, Z., Bobacka, J., Lewenstam, A., & Ivaska, A. U. (2006) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2006.04.022 · Cited by 58
Self-citationXia, C., Advíncula, R. C., Baba, A., & Knoll, W. (2002) · Langmuir · doi:10.1021/la0156661 · Cited by 58
Mixed ion transfer in redox processes of poly(3,4-ethylenedioxythiophene)
Niu, L., Kvarnström, C., & Ivaska, A. U. (2004) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2004.01.029 · Cited by 57
Totally shape-conformable electrode/hydrogel composite for on-skin electrophysiological measurements
Nagamine, K., Chihara, S., Kai, H., Kaji, H., & Nishizawa, M. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.06.076 · Cited by 57
All-Solid-State Ion-Selective Electrodes: A Tutorial for Correct Practice
Criscuolo, F., Hanitra, I. N., Taurino, I., Carrara, S., & Micheli, G. D. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3099209 · Cited by 60
Hydrophobic laser-induced graphene potentiometric ion-selective electrodes for nitrate sensing
Hjort, R. G., Soares, R. R. A., Li, J., Jing, D., Hartfiel, L. M., Chen, B., Belle, B. V., Soupir, M. L., Smith, E. A., McLamore, E. S., et al. (2022) · Microchimica Acta · doi:10.1007/s00604-022-05233-5 · Cited by 62
“Following Bobocka [54], which has become a common method in solid-contact ISE characterization, an applied current of ± 1 nA should be sufficient to polarize an electrode and evaluate the emf stability.”
MethodRecent Developments and Challenges in Solid-Contact Ion-Selective Electrodes
Gao, L., Tian, Y., Gao, W., & Xu, G. (2024) · Sensors · doi:10.3390/s24134289 · Cited by 56
“Currently, the stability of the electrode is evaluated using the reverse current timing potential method proposed by the Bobacka group [32].”
MethodLiu, H., Gu, Z., Zhao, Q. X., Li, S., Ding, X., Xiao, X., & Xiu, G. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.131102 · Cited by 56
Potentiometric sensing utilizing paper-based microfluidic sampling
Cui, J., Lisak, G., Strzalkowska, S., & Bobacka, J. (2014) · The Analyst · doi:10.1039/c3an02157b · Cited by 55
Self-citationYang, N., & Zoski, C. G. (2006) · Langmuir · doi:10.1021/la061167u · Cited by 55
Shao, Y., Yao, Y., Jiang, C., Zhao, F., Liu, X., Ying, Y. B., & Ping, J. F. (2019) · Microchimica Acta · doi:10.1007/s00604-019-3878-7 · Cited by 59
Li, J., Yin, T., & Qin, W. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.03.038 · Cited by 54
Ishige, Y., Klink, S., & Schuhmann, W. W. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201600111 · Cited by 54
Grygołowicz‐Pawlak, E., Wyglądacz, K., Sęk, S., Bilewicz, R., Brzózka, Z., & Malinowska, E. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.12.038 · Cited by 54
Conducting polymers in biosensing: A review
BHATTACHARYYA, A. S. (2024) · Chemical Physics Impact · doi:10.1016/j.chphi.2024.100642 · Cited by 56
Ocypa, M., Michalska, A., & Maksymiuk, K. (2006) · Electrochimica Acta · doi:10.1016/j.electacta.2005.03.080 · Cited by 53
A solid-contact potassium-selective electrode with MoO2 microspheres as ion-to-electron transducer
Zeng, X., & Qin, W. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.05.032 · Cited by 53
Kałuża, D., Jaworska, E., Mazur, M., Maksymiuk, K., & Michalska, A. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01286 · Cited by 53
Solid reference electrode integrated with paper-based microfluidics for potentiometric ion sensing
Ding, R., Fiedoruk-Pogrebniak, M., Pokrzywnicka, M., Koncki, R., Bobacka, J., & Lisak, G. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.128680 · Cited by 53
Self-citationSutter, J., & Pretsch, E. (2005) · Electroanalysis · doi:10.1002/elan.200503373 · Cited by 53
Lindfors, T., & Latonen, R. (2013) · Carbon · doi:10.1016/j.carbon.2013.11.074 · Cited by 52
Zhou, W., Xu, J., Du, Y., & Yang, P. (2010) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2010.11.023 · Cited by 52
Platinum nanoparticles intermediate layer in solid-state selective electrodes
Paczosa‐Bator, B., Cabaj, L., Piech, R., & Skupień, K. (2012) · The Analyst · doi:10.1039/c2an35933b · Cited by 56
Hassan, S. A., ElDin, N. B., Zaazaa, H. E., Moustafa, A. A., & Mahmoud, A. M. (2020) · Microchimica Acta · doi:10.1007/s00604-020-04445-x · Cited by 52
Maksymiuk, K., Stelmach, E., & Michalska, A. (2020) · Membranes · doi:10.3390/membranes10100266 · Cited by 57
Vázquez, M., Bobacka, J., Luostarinen, M., Rissanen, K. T., Lewenstam, A., & Ivaska, A. U. (2004) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-004-0597-7 · Cited by 52
Self-citationTarkuç, S., Şahmetlioğlu, E., Tanyeli, C., Akhmedov, İ. M., & Toppare, L. K. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2006.04.104 · Cited by 52
Nanostructured wearable electrochemical and biosensor towards healthcare management: a review
Khaleque, M. A., Hossain, M. I., Ali, M. R., Bacchu, M. S., Aly, M. A. S., & Khan, M. Z. H. (2023) · RSC Advances · doi:10.1039/d3ra03440b · Cited by 55
Ye, J., Li, F., Gan, S., Jiang, Y., An, Q., Zhang, Q., & Niu, L. (2014) · Electrochemistry Communications · doi:10.1016/j.elecom.2014.10.014 · Cited by 51
Wearable capillary microfluidics for continuous perspiration sensing
Ma, B., Chi, J., Xu, C., Ni, Y., Zhao, C., & Liu, H. (2020) · Talanta · doi:10.1016/j.talanta.2020.120786 · Cited by 53
Jaworska, E., Lewandowski, W., Mieczkowski, J. B., Maksymiuk, K., & Michalska, A. (2013) · The Analyst · doi:10.1039/c3an36741j · Cited by 50
The Water Uptake of Plasticized Poly(vinyl chloride) Solid‐Contact Calcium‐Selective Electrodes
Lindfors, T., Sundfors, F., Höfler, L., & Gyurcsányi, R. E. (2011) · Electroanalysis · doi:10.1002/elan.201100219 · Cited by 50
Optimization of capacitance of conducting polymer solid contact in ion-selective electrodes
Pławińska, Ż., Michalska, A., & Maksymiuk, K. (2015) · Electrochimica Acta · doi:10.1016/j.electacta.2015.11.050 · Cited by 50
Solid contact cadmium ion-selective electrode based on ionic liquid and carbon nanotubes
Wardak, C. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.11.107 · Cited by 51
Lindfors, T., Österholm, A. M., Kauppila, J., & Pesonen, M. (2013) · Electrochimica Acta · doi:10.1016/j.electacta.2013.03.070 · Cited by 49
Baek, S., Green, R. A., & Poole-Warren, L. A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.04.004 · Cited by 55
Application of Nanostructured TCNQ to Potentiometric Ion-Selective K+and Na+Electrodes
Paczosa‐Bator, B., Pięk, M., & Piech, R. (2014) · Analytical Chemistry · doi:10.1021/ac503521t · Cited by 49
Liu, C., Jiang, X., Zhao, Y., Jiang, W., Zhang, Z., & Yu, L. (2017) · Electrochimica Acta · doi:10.1016/j.electacta.2017.01.162 · Cited by 49
Liu, S., Ding, J., & Qin, W. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05971 · Cited by 48
Ashmawy, N. H., Almehizia, A. A., Youssef, T. A., Amr, A. E. E., Al-Omar, M. A., & Kamel, A. H. (2019) · Molecules · doi:10.3390/molecules24081539 · Cited by 49
“Short-term potential stability was studied using chronopotentiometry [39].”
BackgroundHassan, S. S. M., Eldin, A. G., Amr, A. E. E., Al-Omar, M. A., Kamel, A. H., & Khalifa, N. M. (2019) · Sensors · doi:10.3390/s19183891 · Cited by 49
“The low-frequency capacitance for GC/MWCNTs/NO3−-ISE and GC/NO3−-ISE is calculated from the equation ∆E/∆t = I/C [37] and found to be 49.”
MethodInfluentialPietrzak, K., & Wardak, C. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.130720 · Cited by 49
A Smartwatch Integrated with a Paper‐based Microfluidic Patch for Sweat Electrolytes Monitoring
Cao, Q., Liang, B., Mao, X., Wei, J., Tu, T., Lü, F., & Ye, X. (2020) · Electroanalysis · doi:10.1002/elan.202060025 · Cited by 50
All‐Solid‐State Reference Electrodes with Poly(n‐butyl acrylate) Based Membranes
Kisiel, A., Michalska, A., Maksymiuk, K., & Hall, E. A. H. (2007) · Electroanalysis · doi:10.1002/elan.200704065 · Cited by 48
Ameer, S., Ibrahim, H., Kulsoom, F., Ameer, G., & Sher, M. (2024) · Journal of Soils and Sediments · doi:10.1007/s11368-024-03827-5 · Cited by 54
“The instability of the REs often leads to signal drift and instability over time (Bobacka 1999).”
Ion‐selective Electrodes with 3D Nanostructured Conducting Polymer Solid Contact
Szűcs, J., Lindfors, T., Bobacka, J., & Gyurcsányi, R. E. (2015) · Electroanalysis · doi:10.1002/elan.201500465 · Cited by 47
Self-citationExperimental study on stability of different solid contact arrangements of ion-selective electrodes
Michalska, A., Wojciechowski, M., Bulska, E., & Maksymiuk, K. (2010) · Talanta · doi:10.1016/j.talanta.2010.04.012 · Cited by 47
Jasinski, A., Guziński, M., Lisak, G., Bobacka, J., & Bocheńska, M. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.04.089 · Cited by 47
Self-citationGuziński, M., Lisak, G., Sokalski, T., Bobacka, J., Ivaska, A. U., Bocheńska, M., & Lewenstam, A. (2013) · Analytical Chemistry · doi:10.1021/ac302772v · Cited by 47
Self-citationRedox Buffer Capacity of Ion-Selective Electrode Solid Contacts Doped with Organometallic Complexes
Zhen, X. V., Rousseau, C. R., & Bühlmann, P. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b02595 · Cited by 47
Zhao, G., Liang, R., Wang, F., Ding, J., & Qin, W. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.09.125 · Cited by 47
“One unique feature of these ISEs is that the drastical decrease in sample volume does not deteriorate the detection limit of the electrode [9,10].”
MethodInfluentialSponge-based microfluidic sampling for potentiometric ion sensing
Ding, R., & Lisak, G. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.09.024 · Cited by 47
Kisiel, A., Michalska, A., & Maksymiuk, K. (2006) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2006.09.006 · Cited by 46
Durable PEDOT:PSS films obtained from modified water-based inks for electrochemical sensors
Wagner, M., Lisak, G., Ivaska, A. U., & Bobacka, J. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.02.051 · Cited by 46
Self-citationLisak, G., Arnebrant, T., Lewenstam, A., Bobacka, J., & Ruzgas, T. A. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04364 · Cited by 46
Self-citationFurther studies on the role of redox-active monolayer as intermediate phase of solid-state sensors
Grygołowicz‐Pawlak, E., Plachecka, K., Brzózka, Z., & Malinowska, E. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2006.09.029 · Cited by 46
Zachara, J. E., Toczyłowska‐Mamińska, R., Pokrop, R., Zagórska, M., Dybko, A., & Wróblewski, W. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.02.052 · Cited by 46
Paczosa‐Bator, B. (2014) · Microchimica Acta · doi:10.1007/s00604-014-1216-7 · Cited by 47
“The potential response of the GCD/CB/NO3 -ISM electrodes during the polarization was studied by employing the current-reversal chronopotentiometry measurements in order to evaluate the electric capacity of the solid contact and the potential stability of electrodes [20].”
BackgroundMethodInfluentialElectropolymerized hydrophobic polyazulene as solid-contacts in potassium-selective electrodes
He, N., Gyurcsányi, R. E., & Lindfors, T. (2016) · The Analyst · doi:10.1039/c5an02664d · Cited by 45
Zine, N., Bausells, J., Vocanson, F., Lamartine, R. J., Asfari, Z., Teixidor, F., Crespo, E., de Oliveira, I. A. M., Samitier, J., & Errachid, A. (2006) · Electrochimica Acta · doi:10.1016/j.electacta.2006.03.060 · Cited by 45
Fully Written Flexible Potentiometric Sensor Using Two-Dimensional Nanomaterial-Based Conductive Ink
Jiang, C., Li, X., Yao, Y., Ying, Y. B., & Ping, J. F. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04334 · Cited by 44
Rzewuska, A., Wojciechowski, M., Bulska, E., Hall, E. A. H., Maksymiuk, K., & Michalska, A. (2007) · Analytical Chemistry · doi:10.1021/ac070866o · Cited by 44
Sundfors, F., & Bobacka, J. (2004) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2003.12.013 · Cited by 44
Self-citationWireless, Flexible, Ion-Selective Electrode System for Selective and Repeatable Detection of Sodium
Lim, H., Kim, Y., Kwon, S., Mahmood, M., Kwon, Y., Lee, Y.-K., Lee, S. M., & Yeo, W. (2020) · Sensors · doi:10.3390/s20113297 · Cited by 44
“This value was relatively low compared to that of conducting polymers [38], but higher than that of the polymer/carbon case (polyaniline/graphene, 0.”
ResultSjöberg‐Eerola, P., Bobacka, J., Lewenstam, A., & Ivaska, A. U. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.05.004 · Cited by 43
Self-citationJaworska, E., Lewandowski, W., Mieczkowski, J. B., Maksymiuk, K., & Michalska, A. (2012) · Talanta · doi:10.1016/j.talanta.2012.04.054 · Cited by 42
Metadata
- Authors
- Bobacka, J.
- Affiliations
- Åbo Akademi University (FI)
- Corresponding author
- Bobacka, Johan
- ORCID
- Bobacka, Johan
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-10-01
- Volume
- 71
- Issue
- 21
- Pages
- 4932-4937
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2000694408
- Cited by
- 686
- References
- 34
- Citations by year
- 2026: 29 · 2025: 33 · 2024: 54 · 2023: 39 · 2022: 46 · 2021: 49 · 2020: 47 · 2019: 51 · 2018: 33 · 2017: 28 · 2016: 23 · 2015: 23 · 2014: 23 · 2013: 19 · 2012: 25
- FWCI
- 4.77
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Åbo Akademi University Research Portal (submittedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- potential stability, conducting polymers, ion-to-electron transduction, PEDOT, potassium ion-selective electrode, chronopotentiometry, electrochemical impedance spectroscopy, solvent polymeric membranes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.