Potential Stability of All-Solid-State Ion-Selective Electrodes Using Conducting Polymers as Ion-to-Electron Transducers
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Demanding analytical applications such as on-line process analysis and clinical analysis require robust, reliable, and maintenance-free ion sensors of high potential stability. In this work the stability of the electrode potential of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers is critically evaluated by using chronopotentiometry and electrochemical impedance spectroscopy. This study is focused on the relationship between the potential stability of the electrode and the capacitance of the solid contact where ion-to-electron transduction takes place. The influence of this capacitance on the potential stability of all-solid-state ion-selective electrodes is studied experimentally by using conducting polymer layers of different thickness as solid contacts in potassium ion-selective electrodes based on a solvent polymeric membrane. Because of its excellent environmental stability, the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) is used as a model compound for the solid contact material. Chronopotentiometry is found to be a convenient and fast experimental method to critically evaluate the potential stability of different types of ion-selective electrodes.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Also, the high impedance nature of the ISE-based sensors37 required the use of high-impedance voltage buffers to ensure accurate open voltage measurement as intended.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [37]
Citations
Cites
Handbook of conducting polymers
Skotheim, T. A., Elsenbaumer, R. L., & Reynolds, J. R. (1986) · M. Dekker eBooks · Cited by 8,079
Poly(alkylenedioxythiophene)s—new, very stable conducting polymers
Heywang, G., & Jonas, F. (1992) · Advanced Materials · doi:10.1002/adma.19920040213 · Cited by 1,027
Cadogan, A., Gao, Z., Lewenstam, A., Ivaska, A., & Diamond, D. (1992) · Analytical Chemistry · doi:10.1021/ac00045a007 · Cited by 428
Coated wire ion-selective electrodes
Cattrall, R. W., & Freiser, H. (1971) · Analytical Chemistry · doi:10.1021/ac60307a032 · Cited by 387
Horvai, G., Graf, E., Toth, K., Pungor, E., & Buck, R. P. (1986) · Analytical Chemistry · doi:10.1021/ac00126a034 · Cited by 235
GUSTAFSSON, J., LIEDBERG, B., & INGANAS, O. (1994) · Solid State Ionics · doi:10.1016/0167-2738(94)90403-0 · Cited by 213
Technical applications for conductive polymers
Jonas, F., & Heywang, G. (1994) · Electrochimica Acta · doi:10.1016/0013-4686(94)e0057-7 · Cited by 202
Single-piece all-solid-state ion-selective electrode
Bobacka, J., Lindfors, T., McCarrick, M., Ivaska, A., & Lewenstam, A. (1995) · Analytical Chemistry · doi:10.1021/ac00116a034 · Cited by 188
Self-citationBobacka, J., McCarrick, M., Lewenstam, A., & Ivaska, A. (1994) · The Analyst · doi:10.1039/an9941901985 · Cited by 175
Self-citationCharacterization of electroactive polymer layers by electrochemical impedance spectroscopy (EIS)
Musiani, M. M. (1990) · Electrochimica Acta · doi:10.1016/0013-4686(90)80023-h · Cited by 148
Research works printed but not linked: 7
- Nikolskii B. P., 1985, Ion-Sel. Electrode Rev., 7, 39
- Buck R. P., 1976, Anal. Chem., 48, 39R
- Momma T., 1995, Sens. Acuators, B, 24, 728
- Pandey P. C., 1998, Sens. Actuators, B, 46, 65
- Glarum S. H., 1987, J. Electrochem. Soc., 134, 147
- Bobacka J., 1991, Synth. Met., 44, 34
- Koryta, J.; Dvorak, J.; Kavan, L. Principles of Electrochemistry , 2nd ed.; Wiley: Chichester, U.K., 1993; p 38.
Cited by
Items 201–300 of 686
Li, J., Yin, T., & Qin, W. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.08.008 · Cited by 42
Goud, K. Y., Sandhu, S. S., Teymourian, H., Yin, L., Tostado, N., Raushel, F. M., Harvey, S. P., Moores, L. C., & Wang, J. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113172 · Cited by 44
Hydrogen-selective microelectrodes based on silicon needles
Zine, N., Bausells, J., Ivorra, A., Aguiló, J., Zabala, M., Teixidor, F., Masalles, C., Viñas, C., & Errachid, A. (2003) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(03)00069-8 · Cited by 42
“A number of conducting polymers has been used (polypyrrole (PPy) [9], polyoctylthiophene (POT) [10], polyethylenedioxythiophene (PEDOT) [11]).”
BackgroundZou, X. U., Chen, L. D., Lai, C., & Bühlmann, P. (2014) · Electroanalysis · doi:10.1002/elan.201400274 · Cited by 41
Yu, K., He, N., Kumar, N., Wang, N., Bobacka, J., & Ivaska, A. U. (2017) · Electrochimica Acta · doi:10.1016/j.electacta.2017.01.009 · Cited by 42
Self-citationOcaña, C., Abramova, N., Bratov, A. V., Lindfors, T., & Bobacka, J. (2018) · Talanta · doi:10.1016/j.talanta.2018.04.056 · Cited by 41
Self-citationAbdalla, N. S., Youssef, M. A., Algarni, H., Awwad, N. S., & Kamel, A. H. (2019) · Molecules · doi:10.3390/molecules24040712 · Cited by 41
“Constant-current chronopotentiometry has been developed by Bobacka’s group and widely used to evaluate the short-term potential stability of the all-solid-state ISEs [27].”
MethodHassan, S. S. M., Kamel, A. H., & Fathy, M. A. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2022.340239 · Cited by 41
Li, Q., Li, H., Zhang, J., & Xu, Z. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.01.038 · Cited by 41
Choi, K. R., Troudt, B. K., & Bühlmann, P. (2023) · Angewandte Chemie International Edition · doi:10.1002/anie.202304674 · Cited by 40
Xu, J., Jia, F., Li, F., An, Q., Gan, S., Zhang, Q., Ivaska, A. U., & Niu, L. (2016) · Electrochimica Acta · doi:10.1016/j.electacta.2016.11.069 · Cited by 40
“The high electric capacity of the K-MPCs-ISEs plays an important role in resisting the external current polarizing [28].”
BackgroundNitrate Ion Selective Electrode Based on Ion Imprinted Poly(N-methylpyrrole)
Bomar, E., Owens, G., & Murray, G. M. (2017) · Chemosensors · doi:10.3390/chemosensors5010002 · Cited by 41
“Conductive polymer-based solid-state ion selective electrodes are supplanting traditional membrane ion selective electrodes because of the advantage of not requiring a fill solution and because of their more rugged, easily miniaturized construction [7,8].”
BackgroundPapp, S., Kozma, J., Lindfors, T., & Gyurcsányi, R. E. (2020) · Electroanalysis · doi:10.1002/elan.202000045 · Cited by 40
Fan, Y., Xu, Z., Huang, Y., Wang, T., Zheng, S., Depasquale, A., Brückner, C., Lei, Y., & Li, B. (2020) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2020.123299 · Cited by 40
Mousavi, Z., Ekholm, A., Bobacka, J., & Ivaska, A. U. (2009) · Electroanalysis · doi:10.1002/elan.200804427 · Cited by 40
Self-citationKozma, J., Papp, S., & Gyurcsányi, R. E. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c00395 · Cited by 39
Pięk, M., Piech, R., & Paczosa‐Bator, B. (2015) · Journal of The Electrochemical Society · doi:10.1149/2.0631510jes · Cited by 39
Niederhoffer, T., Vanhoestenberghe, A., & Lancashire, H. T. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acb084 · Cited by 38
“A single study used long pulses of 60 s to study polarisation over longer time scales (Bobacka 1999).”
BackgroundMethodHybrid microstructure-based stretchable biosensors for multi-physiological signal sensing
Han, F., Li, H., Huang, L., Zhou, X., Su, R., Yu, H., Tian, Q., Zhao, H., Li, Q., Sun, J., et al. (2024) · eScience · doi:10.1016/j.esci.2024.100327 · Cited by 42
Dithizone Modified Gold Nanoparticles Films for Potentiometric Sensing
Woźnica, E., Wójcik, M., Wojciechowski, M., Mieczkowski, J. B., Bulska, E., Maksymiuk, K., & Michalska, A. (2012) · Analytical Chemistry · doi:10.1021/ac300155f · Cited by 38
Electrochemically Switchable Polymeric Membrane Ion-Selective Electrodes
Zdrachek, E. A., & Bakker, E. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b01282 · Cited by 38
All-Solid-State Polymeric Membrane Ion-Selective Electrodes Based on NiCo 2 S 4 as a Solid Contact
Li, Y., Li, J., & Qin, W. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.1c04748 · Cited by 38
Electrochemical Ion Transfer with Thin Films of Poly(3-octylthiophene)
Cuartero, M., Acres, R. G., MARCO, R. D., Bakker, E., & Crespo, G. A. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b01800 · Cited by 38
Yin, T., Pan, D., & Qin, W. (2011) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-011-1358-z · Cited by 37
Pahal, S., Deepa, M., Bhandari, S., Sood, K. N., & Srivastava, A. K. (2010) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2010.02.027 · Cited by 37
Han, T., Mattinen, U., & Bobacka, J. (2016) · ChemElectroChem · doi:10.1002/celc.201600575 · Cited by 37
Self-citationMichalska, A., & Maksymiuk, K. (2004) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2004.10.030 · Cited by 37
Veltsistas, P. G., Prodromidis, M. I., & Efstathiou, C. E. (2003) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.09.060 · Cited by 37
Hassan, S. S. M., Kamel, A. H., & Fathy, M. A. (2022) · Talanta · doi:10.1016/j.talanta.2022.123907 · Cited by 36
A wearable microfluidic system for efficient sweat collection and real-time detection
Yin, Y., Tan, Z., Zhu, W., Pu, Z., Yu, H., Wang, R., & Li, D. (2024) · Talanta · doi:10.1016/j.talanta.2024.125967 · Cited by 40
Michalska, A., Skompska, M., Mieczkowski, J. B., Zagórska, M., & Maksymiuk, K. (2006) · Electroanalysis · doi:10.1002/elan.200503466 · Cited by 36
Cuartero, M., del Río, J. S., Blondeau, P., Ortuño, J. Á., Rius, F. X., & Andrade, F. J. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.04.022 · Cited by 37
A Solid‐State Reference Electrode Based on a Self‐Referencing Pulstrode
Gao, W., Zdrachek, E. A., Xie, X., & Bakker, E. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201912651 · Cited by 43
Zeng, X., Liu, Y., Jiang, X., Waterhouse, G. I. N., Zhang, Z., & Yu, L. (2021) · Electrochimica Acta · doi:10.1016/j.electacta.2021.138414 · Cited by 36
Gold-modified paper as microfluidic substrates with reduced biofouling in potentiometric ion sensing
Ding, R., Joon, N. K., Ahamed, A., Shafaat, A., Guziński, M., Wagner, M., Ruzgas, T. A., Bobacka, J., & Lisak, G. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.130200 · Cited by 36
Self-citationYu, S., Li, F., Yin, T., Liu, Y., Pan, D., & Qin, W. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.06.049 · Cited by 36
Highly Selective All‐Plastic, Disposable, Cu2+‐Selective Electrodes
Michalska, A., Ocypa, M., & Maksymiuk, K. (2004) · Electroanalysis · doi:10.1002/elan.200403107 · Cited by 36
Bendikov, T. A., & Harmon, T. C. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.07.004 · Cited by 36
Polypyrrole microcapsules as a transducer for ion-selective electrodes
Kisiel, A., Mazur, M., Kuśnieruk, S., Kijewska, K., Krysiński, P., & Michalska, A. (2010) · Electrochemistry Communications · doi:10.1016/j.elecom.2010.08.035 · Cited by 35
Chronopotentiometric Carbonate Detection with All-Solid-State Ionophore-Based Electrodes
Jarolímová, Z., Crespo, G. A., Xie, X., Afshar, M. G., Pawlak, M., & Bakker, E. (2014) · Analytical Chemistry · doi:10.1021/ac5004163 · Cited by 35
Joon, N. K., He, N., Wagner, M., Cárdenas, M., Bobacka, J., & Lisak, G. (2017) · Electrochimica Acta · doi:10.1016/j.electacta.2017.08.126 · Cited by 35
Self-citationLenar, N., Paczosa‐Bator, B., Piech, R., & Królicka, A. (2019) · Electrochimica Acta · doi:10.1016/j.electacta.2019.134718 · Cited by 35
Anderson, E. L., Chopade, S. A., Spindler, B. D., Stein, A., Lodge, T. P., Hillmyer, M. A., & Bühlmann, P. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00296 · Cited by 36
Peng, Z., Liu, R., Xu, Z., Chi, H., Wang, Z., & Zhao, Y. J. (2022) · Applied Materials Today · doi:10.1016/j.apmt.2022.101623 · Cited by 36
Veder, J., MARCO, R. D., Clarke, G., Jiang, S. P., Prince, K. E., Pretsch, E., & Bakker, E. (2011) · The Analyst · doi:10.1039/c1an15267j · Cited by 35
Kim, S. Y., Kim, K.-M., Hoffman–Kim, D., Song, H., & Palmore, G. T. R. (2010) · ACS Applied Materials & Interfaces · doi:10.1021/am1008369 · Cited by 36
Klink, S., Ishige, Y., & Schuhmann, W. W. (2017) · ChemElectroChem · doi:10.1002/celc.201700091 · Cited by 35
A new solid-state silver ion-selective electrode based on a novel tweezer-type calixarene derivative
Lü, J., Pang, D., Zeng, X., & He, X. (2004) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2004.01.017 · Cited by 35
Pięk, M., Piech, R., & Paczosa‐Bator, B. (2018) · Journal of The Electrochemical Society · doi:10.1149/2.0161803jes · Cited by 34
Kraikaew, P., Sailapu, S. K., & Bakker, E. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c03254 · Cited by 34
Mattinen, U., Rabiej, S., Lewenstam, A., & Bobacka, J. (2011) · Electrochimica Acta · doi:10.1016/j.electacta.2011.07.082 · Cited by 34
Self-citationOdijk, M., van der Wouden, E. J., Olthuis, W., Ferrari, M. D., Tolner, E. A., van den Maagdenberg, A. M. J. M., & van den Berg, A. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.06.138 · Cited by 34
Potentiometric all solid-state pH glass sensors
Vonau, W., Gabel, J., & Jahn, H. (2005) · Electrochimica Acta · doi:10.1016/j.electacta.2005.02.084 · Cited by 34
Sjöberg‐Eerola, P., Nylund, J., Bobacka, J., Lewenstam, A., & Ivaska, A. U. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.06.041 · Cited by 34
Self-citationSolid-contact ion-selective electrodes for aromatic cations based on π-coordinating soft carriers
Bobacka, J. (2002) · Talanta · doi:10.1016/s0039-9140(02)00284-9 · Cited by 34
Self-citationTeekayupak, K., Lomae, A., Ağır, İ., Chuaypen, N., Dissayabutra, T., Henry, C. S., Chailapakul, O., Özer, T., & Ruecha, N. (2023) · Microchimica Acta · doi:10.1007/s00604-023-05818-8 · Cited by 33
Sweat‐powered, skin‐adhesive multimodal sensor for long‐term and real‐time sweat monitoring
He, X., Li, Z., Huang, X., Zhang, Q., Zeng, Y., Li, J., Yiu, C. K., Yang, Y., Zhou, J., Xu, G., et al. (2024) · BMEMat · doi:10.1002/bmm2.12124 · Cited by 38
Sun, Q., Li, W., & Su, B. (2015) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2014.12.038 · Cited by 33
Láng, G. G., Újvári, M., Bazsó, F., Vesztergom, S., & Újhelyi, F. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.01.068 · Cited by 33
Turaç, E., Şahmetlioğlu, E., Toppare, L. K., & Yürük, H. (2010) · Designed Monomers & Polymers · doi:10.1163/138577210x12634696333677 · Cited by 33
Lenik, J., & Nieszporek, J. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.09.034 · Cited by 33
Silver(I)-selective electrodes based on rare earth element double-decker porphyrins
Joon, N. K., Barnsley, J. E., Ding, R., Lee, S., Latonen, R., Bobacka, J., Gordon, K. C., Ogawa, T., & Lisak, G. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.127311 · Cited by 33
Self-citationSilva, R., Ahamed, A., Cheong, Y. H., Zhao, K., Ding, R., & Lisak, G. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2022.339495 · Cited by 33
Khripoun, G. A., Volkova, E. A., Liseenkov, A. V., & Mikhelson, K. N. (2006) · Electroanalysis · doi:10.1002/elan.200603532 · Cited by 33
Zine, N., Bausells, J., Teixidor, F., Viñas, C., Masalles, C., Samitier, J., & Errachid, A. (2006) · Materials Science and Engineering C · doi:10.1016/j.msec.2005.10.073 · Cited by 33
Small-volume radial flow cell for all-solid-state ion-selective electrodes
Vázquez, M., Bobacka, J., Ivaska, A. U., & Lewenstam, A. (2003) · Talanta · doi:10.1016/s0039-9140(03)00408-9 · Cited by 33
Self-citationStable Pb2+ ion-selective electrodes based on polyaniline-TiO2 solid contacts
Zeng, X., Jiang, W., Jiang, X., Waterhouse, G. I. N., Zhang, Z., & Yu, L. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.10.008 · Cited by 33
Electroanalysis with Pure, Chemically Modified and Sol-Gel-Derived Silica-Based Materials
Walcarius, A. (2001) · Electroanalysis · doi:10.1002/1521-4109(200105)13:8/9<723::aid-elan723>3.0.co;2-r · Cited by 223
Self-citationAn All-solid-state Cd2+-selective electrode with a low detection limit
Yu, S., Li, F., & Qin, W. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.01.052 · Cited by 32
Ghosh, T., Chung, H., & Rieger, J. (2017) · Sensors · doi:10.3390/s17112536 · Cited by 32
“The absence of the high frequency semicircle (the inset of Figure 4c) indicates very fast ion and electron transfers at the ChPBN/solution interfaces [11].”
BackgroundMethodInfluentialPotassium Ion Selective Electrode Using Polyaniline and Matrix-Supported Ion-Selective PVC Membrane
Tran, T. N. T., Qiu, S., & Chung, H. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2871001 · Cited by 32
“Many electronically conducting polymers including polypyrroles [24], poly(3-octylthiophene) (POT) [25], and poly(3,4-etyhlene-dioxythiophene) (PEDOT) [26], and polyaniline (PANI) [27] were tested as ion-to-electron transducers.”
BackgroundLiu, Y., Liu, Y., Gao, Y., & Wang, P. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.09.113 · Cited by 32
Yin, T., Han, T., Li, C., Qin, W., & Bobacka, J. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.12.022 · Cited by 32
“Multi-chronopotentiometry was used to investigate the potential stability of the proposed electrodes, instead of single chronopotentiometry [28].”
BackgroundMethodInfluentialSelf-citationWang, Y., Xu, H., Yang, X., Luo, Z., Zhang, J., & Li, G. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.07.064 · Cited by 32
Yamani, H. Z., Safwat, N., Mahmoud, A. M., Ayad, M. F., Ghany, M. F. A., & Gomaa, M. M. (2023) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-023-04818-0 · Cited by 31
“This data provides indications about the ease of ion-to-electron transfer at the electrode interface [37].”
BackgroundÚjvári, M., Gubicza, J., Kondratiev, V. V., Szekeres, K. J., & Láng, G. G. (2015) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-015-2746-6 · Cited by 31
Tang, W., Yu, J., Wang, Z., Jeerapan, I., Yin, L., Zhang, F., & He, P. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.06.020 · Cited by 30
Lenar, N., Paczosa‐Bator, B., & Piech, R. (2019) · Microchimica Acta · doi:10.1007/s00604-019-3830-x · Cited by 31
Cheong, Y. H., Ge, L., Zhao, N., Teh, L. K., & Lisak, G. (2020) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2020.114262 · Cited by 31
Zdrachek, E. A., & Bakker, E. (2021) · Microchimica Acta · doi:10.1007/s00604-021-04805-1 · Cited by 31
Qi, L., Jiang, T., Liang, R., & Qin, W. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c01116 · Cited by 32
Hao, J., Zhu, Z., Hu, C., & Liu, Z. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c00593 · Cited by 32
Özer, T., & Henry, C. S. (2022) · Microchimica Acta · doi:10.1007/s00604-022-05264-y · Cited by 34
Optimization of the Composition of Interfaces in Miniature Planar Chloride Electrodes
Paciorek, R., van der Wal, P. D., de Rooij, N. F., & Maj‐Żurawska, M. (2003) · Electroanalysis · doi:10.1002/elan.200302816 · Cited by 31
Photocatalytic photosystem I/PEDOT composite films prepared by vapor-phase polymerization
Robinson, M. T., Simons, C. E., Cliffel, D. E., & Jennings, G. K. (2017) · Nanoscale · doi:10.1039/c7nr01158j · Cited by 31
Zeng, X., & Qin, W. (2019) · Talanta · doi:10.1016/j.talanta.2019.120570 · Cited by 31
Liu, S., Zhong, L., Tang, Y., Lai, M., Wang, H., Bao, Y., Ma, Y., Wang, W., Niu, L., & Gan, S. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.4c00609 · Cited by 35
Monitoring of the electrochemical degradation of PEDOT films on gold using the bending beam method
Újvári, M., Takács, M., Vesztergom, S., Bazsó, F., Újhelyi, F., & Láng, G. G. (2011) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-011-1472-y · Cited by 30
Urbanowicz, M., Jasinski, A., Jasińska, M., Drucis, K., Ekman, M., Szarmach, A., Suchodolski, R., Pomećko, R., & Bocheńska, M. (2017) · Electroanalysis · doi:10.1002/elan.201700149 · Cited by 30
Coulometric response of solid-contact anion-sensitive electrodes
Han, T., Mattinen, U., Mousavi, Z., & Bobacka, J. (2020) · Electrochimica Acta · doi:10.1016/j.electacta.2020.137566 · Cited by 30
Self-citationAbd‐Rabboh, H. S. M., Amr, A. E. E., Elsayed, E. A., Sayed, A. Y. A., & Kamel, A. H. (2021) · RSC Advances · doi:10.1039/d1ra00581b · Cited by 30
All-solid-state potassium-selective sensor based on carbon black modified thermoplastic electrode
Özer, T., & Henry, C. S. (2021) · Electrochimica Acta · doi:10.1016/j.electacta.2021.139762 · Cited by 30
Turaç, E., Ak, M., Şahmetlioğlu, E., Şener, M. K., & Kaya, M. A. (2011) · Russian Journal of General Chemistry · doi:10.1134/s1070363211120164 · Cited by 30
Ding, J., Yu, N., Wang, X., & Qin, W. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03522 · Cited by 29
Park, H. J., Jeong, J., Yoon, J. H., Son, S. G., Kim, Y. K., Kim, D. H., Lee, K. G., & Choi, B. G. (2019) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2019.11.001 · Cited by 29
Pietrzak, K., Morawska, K., Malinowski, S., & Wardak, C. (2022) · Membranes · doi:10.3390/membranes12111150 · Cited by 29
“What is more, the electrical parameters of the electrodes are also important, which can be estimated on the basis of measurements using impedance spectroscopy and chronopotentiometry [17,18].”
BackgroundMethodSoares, R. R. A., Hjort, R. G., Pola, C. C., Jing, D., Cecon, V. S., Claussen, J. C., & Gomes, C. L. (2023) · Microchimica Acta · doi:10.1007/s00604-022-05615-9 · Cited by 31
Novel all-solid-state copper(II) microelectrode based on a dithiomacrocycle as a neutral carrier
de Oliveira, I. A. M., Pla‐Roca, M., Escriche, L., Casabó, J., Zine, N., Bausells, J., Teixidor, F., Crespo, E., Errachid, A., & Samitier, J. (2006) · Electrochimica Acta · doi:10.1016/j.electacta.2006.03.042 · Cited by 29
Phoonsawat, K., Özer, T., Dungchai, W., & Henry, C. S. (2022) · The Analyst · doi:10.1039/d2an01220k · Cited by 31
Metadata
- Authors
- Bobacka, J.
- Affiliations
- Åbo Akademi University (FI)
- Corresponding author
- Bobacka, Johan
- ORCID
- Bobacka, Johan
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-10-01
- Volume
- 71
- Issue
- 21
- Pages
- 4932-4937
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2000694408
- Cited by
- 686
- References
- 34
- Citations by year
- 2026: 29 · 2025: 33 · 2024: 54 · 2023: 39 · 2022: 46 · 2021: 49 · 2020: 47 · 2019: 51 · 2018: 33 · 2017: 28 · 2016: 23 · 2015: 23 · 2014: 23 · 2013: 19 · 2012: 25
- FWCI
- 4.77
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Åbo Akademi University Research Portal (submittedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- potential stability, conducting polymers, ion-to-electron transduction, PEDOT, potassium ion-selective electrode, chronopotentiometry, electrochemical impedance spectroscopy, solvent polymeric membranes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.