Potential Stability of All-Solid-State Ion-Selective Electrodes Using Conducting Polymers as Ion-to-Electron Transducers
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Demanding analytical applications such as on-line process analysis and clinical analysis require robust, reliable, and maintenance-free ion sensors of high potential stability. In this work the stability of the electrode potential of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers is critically evaluated by using chronopotentiometry and electrochemical impedance spectroscopy. This study is focused on the relationship between the potential stability of the electrode and the capacitance of the solid contact where ion-to-electron transduction takes place. The influence of this capacitance on the potential stability of all-solid-state ion-selective electrodes is studied experimentally by using conducting polymer layers of different thickness as solid contacts in potassium ion-selective electrodes based on a solvent polymeric membrane. Because of its excellent environmental stability, the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) is used as a model compound for the solid contact material. Chronopotentiometry is found to be a convenient and fast experimental method to critically evaluate the potential stability of different types of ion-selective electrodes.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Also, the high impedance nature of the ISE-based sensors37 required the use of high-impedance voltage buffers to ensure accurate open voltage measurement as intended.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [37]
Citations
Cites
Handbook of conducting polymers
Skotheim, T. A., Elsenbaumer, R. L., & Reynolds, J. R. (1986) · M. Dekker eBooks · Cited by 8,079
Poly(alkylenedioxythiophene)s—new, very stable conducting polymers
Heywang, G., & Jonas, F. (1992) · Advanced Materials · doi:10.1002/adma.19920040213 · Cited by 1,027
Cadogan, A., Gao, Z., Lewenstam, A., Ivaska, A., & Diamond, D. (1992) · Analytical Chemistry · doi:10.1021/ac00045a007 · Cited by 428
Coated wire ion-selective electrodes
Cattrall, R. W., & Freiser, H. (1971) · Analytical Chemistry · doi:10.1021/ac60307a032 · Cited by 387
Horvai, G., Graf, E., Toth, K., Pungor, E., & Buck, R. P. (1986) · Analytical Chemistry · doi:10.1021/ac00126a034 · Cited by 235
GUSTAFSSON, J., LIEDBERG, B., & INGANAS, O. (1994) · Solid State Ionics · doi:10.1016/0167-2738(94)90403-0 · Cited by 213
Technical applications for conductive polymers
Jonas, F., & Heywang, G. (1994) · Electrochimica Acta · doi:10.1016/0013-4686(94)e0057-7 · Cited by 202
Single-piece all-solid-state ion-selective electrode
Bobacka, J., Lindfors, T., McCarrick, M., Ivaska, A., & Lewenstam, A. (1995) · Analytical Chemistry · doi:10.1021/ac00116a034 · Cited by 188
Self-citationBobacka, J., McCarrick, M., Lewenstam, A., & Ivaska, A. (1994) · The Analyst · doi:10.1039/an9941901985 · Cited by 175
Self-citationCharacterization of electroactive polymer layers by electrochemical impedance spectroscopy (EIS)
Musiani, M. M. (1990) · Electrochimica Acta · doi:10.1016/0013-4686(90)80023-h · Cited by 148
Research works printed but not linked: 7
- Nikolskii B. P., 1985, Ion-Sel. Electrode Rev., 7, 39
- Buck R. P., 1976, Anal. Chem., 48, 39R
- Momma T., 1995, Sens. Acuators, B, 24, 728
- Pandey P. C., 1998, Sens. Actuators, B, 46, 65
- Glarum S. H., 1987, J. Electrochem. Soc., 134, 147
- Bobacka J., 1991, Synth. Met., 44, 34
- Koryta, J.; Dvorak, J.; Kavan, L. Principles of Electrochemistry , 2nd ed.; Wiley: Chichester, U.K., 1993; p 38.
Cited by
Items 601–686 of 686
Graphene Flakes Decorated with Dispersed Gold Nanoparticles as Nanomaterial Layer for ISEs
Niemiec, B., Lenar, N., Piech, R., Skupień, K., & Paczosa‐Bator, B. (2021) · Membranes · doi:10.3390/membranes11070548 · Cited by 3
“with a high surface, ensuring high electrical capacity, is essential for obtaining a stable and fast response of sensors [10].”
BackgroundMao, C., Zhao, K., Loong, C. F. J., Song, D., & Lisak, G. (2024) · ACS Sensors · doi:10.1021/acssensors.4c01673 · Cited by 3
Wei, S., Zhao, J., Ke, S., Zou, M., Han, Q., & Cui, G. (2025) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2025.108903 · Cited by 3
Development of a neural probe to measure potassium during a cortical spreading depression in-vivo
van der Wouden, E. J., Tolner, E. A., Odijk, M., Olthuis, W., van den Maagdenburg, A. M. J. M., Ferrari, M. D., & van den Berg, A. (2013) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2013.6627226 · Cited by 3
Salim, W. W. A. W., Zeitchek, M., Hermann, A. C., Ricco, A. J., Tan, M. X., Selch, F., Fleming, E. D., Bebout, B. M., Bader, M. M., Haque, A. U., et al. (2013) · Journal of Visualized Experiments · doi:10.3791/50020 · Cited by 3
Skórska, L., Michalska, A., Wojciechowski, M., Bulska, E., & Maksymiuk, K. (2011) · Electrochimica Acta · doi:10.1016/j.electacta.2011.12.066 · Cited by 3
Mixed Gold and Platinum Nanostructured Layers for All-Solid-State Ion Sensors
Criscuolo, F., Lobello, L., Taurino, I., Demarchi, D., Carrara, S., & Micheli, G. D. (2018) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2018.8630299 · Cited by 3
“current direction occurs, followed by a slow potential drift at longer times [27].”
BackgroundNiemiec, B., Piech, R., & Paczosa‐Bator, B. (2025) · Molecules · doi:10.3390/molecules30051118 · Cited by 2
Han, T., Chen, S., Song, T., Lin, X., Han, D., Bobacka, J., & Niu, L. (2025) · Electrochemistry Communications · doi:10.1016/j.elecom.2025.107911 · Cited by 2
Self-citationRobinson, E. E. A., Chipangura, Y. E., Coyle, H. D., Stein, A., & Bühlmann, P. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.5c03061 · Cited by 2
Laucirica, G., Martínez-Lorca, N., Crespo, G. A., & Cuartero, M. (2026) · Talanta · doi:10.1016/j.talanta.2026.129444 · Cited by 2
Ishige, Y., Klink, S., & Schuhmann, W. W. (2016) · Angewandte Chemie · doi:10.1002/ange.201600111 · Cited by 2
Multilayer and Surface Immobilization of EDOT-Decorated Nanocapsules
Hambly, B. P., Sears, C. K., Guziński, M., Perez, F. A., Latonen, R., Bobacka, J., Pendley, B. D., & Lindner, E. (2020) · Langmuir · doi:10.1021/acs.langmuir.0c03160 · Cited by 2
Self-citationRen, L., Ji, M., Zhuang, X., Tian, C., Shi, C., Hao, X., Luan, F., & Li, Y. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.110679 · Cited by 2
Guo, Y., Wang, C., Han, G., & Nyein, H. Y. Y. (2024) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2024.100509 · Cited by 12
Zeng, H., Ren, G., Gao, N., Xu, T., Jin, P., Yin, Y., Liu, R., Zhang, S., Zhang, M., & Mao, L. (2024) · Angewandte Chemie · doi:10.1002/ange.202407063 · Cited by 2
Lenar, N., Piech, R., & Paczosa‐Bator, B. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms252212381 · Cited by 2
“…with such a layer are also characterized by rather low (~200 µ F) electrical However, since the PEDOT:PSS polymer itself does not have high electrical capacity, ion-selective electrodes with such a layer are also characterized by rather low (~200 µF) electrical capacity [6]. capacity [6].”
InfluentialWu, B., Li, B., Chen, P., Yu, S., Jin, Y., Wu, L., Xiao, Z., Sun, L., Yu, D., & Cao, Z. Y. (2025) · Talanta · doi:10.1016/j.talanta.2025.128674 · Cited by 2
A microgripper sensor device capable of detecting ion efflux from whole cells
Daunton, R., Wood, D., Gallant, A. J., & Kataky, R. (2014) · RSC Advances · doi:10.1039/c4ra05052e · Cited by 2
Solid-State Ion-Selective Electrode with an Ion – Electron Transducer for Doxycycline Determination
Ryasenskii, S. S., Феофанова, М. А., Васильева, Д. В., & Мантров, Г. И. (2016) · Pharmaceutical Chemistry Journal · doi:10.1007/s11094-016-1424-z · Cited by 2
Electrochromic Polymer Devices: Active-Matrix Displays and Switchable Polarizers
Ersman, P. A. (2006) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 2
Láng, G. G., Kondratiev, V. V., Újvári, M., Vesztergom, S., Szekeres, K. J., & Zalka, D. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-409547-2.13301-3 · Cited by 2
“They used a solution that contained 0.01 M EDOT and 0.1 M supporting electrolyte (either KCl, NaCl or NaPSS with an average molar mass of 7000).”
BackgroundMethodInfluentialCandle soot-smoked electrodes as a natural superhydrophobic material for potentiometric sensors
Lenar, N., Piech, R., & Paczosa‐Bator, B. (2024) · Talanta · doi:10.1016/j.talanta.2024.127389 · Cited by 1
Yu, Z., Wang, H., He, Y., Chen, R., Tang, X., & Xiong, B. (2025) · Chemosensors · doi:10.3390/chemosensors13070252 · Cited by 1
An environmentally relevant solid-state sensor for the trace detection of triclopyr herbicide
Kamel, A. H., & Abd‐Rabboh, H. S. M. (2025) · Analytical Methods · doi:10.1039/d5ay00916b · Cited by 1
Saha, A., & Alam, M. A. (2025) · ACS Sensors · doi:10.1021/acssensors.5c03094 · Cited by 1
Weaving New Smart Objects: Actuation and Sensing at a Single Electroactive Interface
Mariani, F., Quast, T., Schuhmann, W. W., Gualandi, I., & Scavetta, E. (2025) · ChemElectroChem · doi:10.1002/celc.202500263 · Cited by 1
Enhanced single-frequency effective capacitance C sensing for solid-contact ion-selective electrodes
Han, T., Song, T., Han, D., & Niu, L. (2026) · Results in Chemistry · doi:10.1016/j.rechem.2026.103093 · Cited by 1
Han, T., Song, T., Gan, J., Han, D., & Niu, L. (2026) · Electrochem · doi:10.3390/electrochem7020010 · Cited by 1
“The equivalent circuit modeling of conducting polymer-covered electrodes reveals that the diffusion time constant τ reflects the diffusion pseudocapacitance of the solid contact when interpreting interfacial properties [3,28].”
Passive micromixers and organic electrochemical transistors for biosensor applications
Kanakamedala, S. K. (2011) · Cited by 1
A passive water transfer/retention system for long term functionality of an on-site sensing device
Chen, Y., Chen, W., Lim, R., & Cheng, M. (2021) · IEEE Electronic Components and Technology Conference (ECTC) · doi:10.1109/ectc32696.2021.00347 · Cited by 1
Selective Deionization of Thin-Layer Samples Using Tandem Carbon Nanotubes–Polymeric Membranes
Wiorek, A., Cuartero, M., & Crespo, G. A. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.3c02965 · Cited by 1
Bene, C., Laborde, A., Légnani, M., Emmanuel Flahaut, B., Launay, J., & Temple‐Boyer, P. (2024) · Sensors · doi:10.3390/s24185994 · Cited by 1
All-Solid-State Zn2+-Selective Electrodes for Wastewater Measurements
Ju, L., Yu, S. Y., Zhang, X. Y., & Yuan, J. (2012) · Advanced materials research · doi:10.4028/www.scientific.net/amr.441.564 · Cited by 1
Arvand, M., Ansari, R., & Heydari, L. (2014) · Journal of Analytical Chemistry · doi:10.1134/s1061934814090020 · Cited by 1
Latif, U., & Dickert, F. L. (2014) · Nanostructure science and technology · doi:10.1007/978-1-4939-1301-5_4 · Cited by 1
Development of potassium ion sensors using polypyrrole electrodes on a polyimide substrate
Ramachandran, V., Yoon, H., & Varadan, V. K. (2008) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.776834 · Cited by 1
“According to [2] a coated wire electrode (CWE) may respond and sense different concentrations of potassium but the response is unstable.”
BackgroundElectrochemical Devices based on Conjugated Polymers
Isaksson, J. (2007) · Cited by 1
Metrologia şi Monitorizarea Mediului
Jäntschi, L. (2003) · Cited by 1
Zhai, J., Zhang, Y., Zhao, D., Kou, L., & Zhao, G. (2022) · Data in Brief · doi:10.1016/j.dib.2022.107949 · Cited by 1
“5 μA was applied for 200 s to produce polymerization charges of 100 μC [2,3] .”
MethodGuo, Y., Wang, C., Han, G., & Nyein, H. Y. Y. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4801431 · Cited by 1
Applications: Selected Experimental Results
Láng, G. G., & Barbero, C. A. (2012) · Monographs in electrochemistry · doi:10.1007/978-3-642-27651-4_7
Gryczan, P., Michalska, A., & Maksymiuk, K. (2014) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-014-2464-5
“The capacitance value was obtained from the slope of linear part of a chronopotentiometric curve recorded for oxidation/ reduction of this polymer layer, using the Bobacka method [29] (data not shown).”
MethodIsaksson, J. (2005) · DiVA (Linkoping University)
Guo, X. (2012) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 1
Calixarenes as Potential Ionophores for Thallium Ion-Selective Electrodes
Chester, R. T. (2007)
Stelzle, M., Bieg, C., Fuchsberger, K., Linke, G., Samba, R., & Werner, S. (2017) · SENSOR International Conference on Sensors and Measurement Technology (SENSOR) · doi:10.5162/sensor2017/a3.3
Charge Transport Modulation and Optical Absorption Switching in Organic Electronic Devices
Ersman, P. A. (2007) · DiVA (Linkoping University)
Paper-based solution sampling coupled with potentiometric ion sensors
Ding, R. (2021) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/152695
Marttila, L., Salomäki, M., Kivelä, H., Hassinen, J., Granroth, S., Mäkilä, E. M., Nyman, J. O., & Lukkari, J. (2022) · ACS Applied Polymer Materials · doi:10.1021/acsapm.2c01366
Liu, S., Yin, T., Li, Z., & Wang, J. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4501397
Liu, S., Yin, T., Li, Z., & Wang, J. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4584758
Chronopotentiometric Sensors for Antimicrobial Peptide-Based BiosensingPreprint
Zhao, J., Ding, J., Luan, F., & Qin, W. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4641157
Conducting Organic Polymers Used in Biosensors for Diagnostic and Pharmaceutical Applications
Dash, R., Das, A., & BHATTACHARYYA, A. S. (2024) · Wiley eBooks · doi:10.1002/9783527842810.ch14
Muztahidul, I. M., Kamiya, T., Tsuruta, S., Ota, S., Koike, S., Takai, M., & Futagawa, M. (2024) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors60989.2024.10785011
Lai, J., Tu, A., Lai, K., Xiao, L., Rahimi, R., & Jiang, H. (2025) · Ionics · doi:10.1007/s11581-025-06246-9
“(4)) [33]: where i is the current and C is the capacitance of the EDL.”
Cai, X., Xia, R., Chen, S., Liu, Z., Zhao, Y., Wang, C., Song, Z., Yang, M., Li, P., & Huang, X. (2025) · Advanced Materials · doi:10.1002/adma.202501749
Muztahidul, I. M., Kamiya, T., Tsuruta, S., Ota, S., Koike, S., Takai, M., & Futagawa, M. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116728
Hefnawy, A., Aljar, M. A. A., Abd‐Rabboh, H. S. M., & Kamel, A. H. (2025) · Environmental Science Nano · doi:10.1039/d5en00726g
Donaldson, K. M., Mack, J., Shang, Y., Underwood, I., & Cockell, C. S. (2025) · Biomimetics · doi:10.3390/biomimetics10110742 · Cited by 1
“Efforts have been made to stabilise the interfacial boundary potential through the use of various conducting polymer membranes as a replacement for the well-defined ion–electron exchanges enabled by the filling solution [84–86].”
Yin, T., Mu, S., & Qin, W. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.116316
Derar, A. R., Ahmed, N., & Hussien, E. M. (2024) · Figshare · doi:10.6084/m9.figshare.26604520
Teekayupak, K., Sakulduangdee, T., Kaewchairueang, K., Chuaypen, N., Dissayabutra, T., Henry, C. S., Citterio, D., & Ruecha, N. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202501994
“The low-frequency capacitance (C L ) of the solid-contact layer was obtained from chronopotentiometry under a constant current of ± 1 nA for 60 s in 0.1 м NaCl, following Bobacka’s protocol [ 40 ].”
InfluentialEnhancing Analytical Performance of Ammonium Potentiometric Sensors with Carbon Nanocomposites
Morawska, K., Malinowski, S., & Wardak, C. (2026) · Molecules · doi:10.3390/molecules31050759
“…solid contact, which, due to their imperfections resulting from poor transduction and charge transfer (the result of the inefficiency of this process is poor reversibility and stability of the potential), must be modified by introducing a material that exhibits ion-to-electron conductivity [9,10].”
Jiang, D. M., Tu, F., & Wang, Q. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3674746
Solaiman, M., Hossain, N. I., & Tabassum, S. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.6531858
Potentiometric Solid-Contact K+ Ion-Selective Electrodes Based on the KMnFe(CN)6 Transducer
Deng, H., Liu, Z., Niu, L., & Gan, S. (2026) · Membranes · doi:10.3390/membranes16050156
“Early conducting polymers, such as PEDOT(PSS), have been widely used due to their facile preparation and high electronic and ionic conductivity [25–27].”
Deng, H., Liu, Z., Liu, S., Gao, L., Zhong, L., (17594), W. W., Niu, L., & Gan, S. (2026) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2026.120333
Kamel, A. H., & Abd‐Rabboh, H. S. M. (2026) · Analytical Methods · doi:10.1039/d6ay00553e
Fabrication of Liquid-Contact Polymeric Membrane Ion-Selective Microelectrodes with a Long Lifetime
Liu, Y., Qi, L., & Qin, W. (2026) · Membranes · doi:10.3390/membranes16070216
“The intrinsic properties of SC materials significantly influence potential stability and long-term reproducibility [17].”
Meng, W., Zeng, X., Zhou, W., Tai, W., Duan, J., Li, Z., Crespo, G. A., & Luo, X. (2026) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2026.140427
Rosabal-Quiros, G. M., Mousavi, Z., Sokalski, T., Issajev, A., Leito, I., & Bobacka, J. (2026) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2026.140464
Self-citationZhou, Y., Zhao, Y., Zheng, K., Hou, X., Zhao, W., Zhang, Y., & Liu, X. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.7134145
Morawska, K., Wardak, C., Malinowski, S., Czichy, M., Gajewska, B., & Janasik, P. (2026) · Microchimica Acta · doi:10.1007/s00604-026-08300-3
Kamel, A. H., Al-Radhi, H. M., & Abd‐Rabboh, H. S. M. (2026) · RSC Advances · doi:10.1039/d6ra05439k
Saadati, A., Bokaei, H., Richtera, L., Zouhar, J., & Ashrafi, A. M. (2026) · ACS Measurement Science Au · doi:10.1021/acsmeasuresciau.6c00094 · Cited by 1
Simplified Lead Detection: Graphene-Based Potentiometric Sensors for Pb(II) Monitoring
Drużyńska, M., Lenar, N., & Paczosa‐Bator, B. (2026) · Sensors · doi:10.3390/s26175395
“It should also be emphasized that many of the previously reported Pb(II)-selective electrodes relied on additional intermediate layers based on conducting polymers, ionic liquids, nanocomposites, fullerene derivatives, or graphite contacts [31–36].”
InfluentialRodríguez, C. H., Soto, A. P. V., Contreras, F. A. R., Díaz‐Real, J. A., Bueno, J. D. J. P., & Domínguez, A. S. (2026) · Measurement · doi:10.1016/j.measurement.2026.123087
Tanaka, S., Ishizaki, Y., Aoki, K., Nagao, Y., Matsui, J., Seki, T., & Nagano, S. (2026) · ChemPhotoChem · doi:10.1002/cptc.70269
Izadyar, A., Weatherford, S., & McCain, E. (2026) · Sensors · doi:10.3390/s26185722
“An appropriately optimized PEDOT film reduced baseline drift and improved signal consistency through its high interfacial capacitance and efficient https://doi.org/10.3390/s26185722 mixed ionic–electronic conductivity [22–25].”
InfluentialQi, Q., Duan, J., Lei, Y., Zhou, S., Liu, Q. S., Wang, Q., Gao, N., Sun, W., Zhan, Z., & Wu, Y. (2026) · Biosensors · doi:10.3390/bios16090523
“According to the relationship between capacitance and potential fluctuation, ∆ E = ∆ Q/C, limited charge-storage capacity in the solid-contact layer can amplify small charge perturbations into open-circuit potential fluctuations and noise [88].”
Zhong, L., Mousavi, Z., Wang, T., 王浩丞, Niu, L., Gan, S., & Bobacka, J. (2026) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2026.141009
Self-citationDeng, Y., Mutalib, N. A. A., Xiong, J., Suzuki, H. R., & Tsujimura, S. (2026) · Analytical Chemistry · doi:10.1021/acs.analchem.6c01226
Lenik, J., & Witkowska, K. (2026) · Sensors · doi:10.3390/s26206633
“…electrodes has led to an improvement in the reversibility and stability of ion-electron conductivity, an increase in the charge transfer current at equilibrium—eliminating the possibility of system polarisation—and the elimination of side reactions other than the main electrode reaction [15].”
Yang, Y., Wang, J., Hu, Z., Zhang, S., Peng, H., & Sun, X. (2026) · 中国科学通报:英文版 · doi:10.1016/j.scib.2026.10.037
Metadata
- Authors
- Bobacka, J.
- Affiliations
- Åbo Akademi University (FI)
- Corresponding author
- Bobacka, Johan
- ORCID
- Bobacka, Johan
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-10-01
- Volume
- 71
- Issue
- 21
- Pages
- 4932-4937
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2000694408
- Cited by
- 686
- References
- 34
- Citations by year
- 2026: 29 · 2025: 33 · 2024: 54 · 2023: 39 · 2022: 46 · 2021: 49 · 2020: 47 · 2019: 51 · 2018: 33 · 2017: 28 · 2016: 23 · 2015: 23 · 2014: 23 · 2013: 19 · 2012: 25
- FWCI
- 4.77
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Åbo Akademi University Research Portal (submittedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- potential stability, conducting polymers, ion-to-electron transduction, PEDOT, potassium ion-selective electrode, chronopotentiometry, electrochemical impedance spectroscopy, solvent polymeric membranes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.