Potential Stability of All-Solid-State Ion-Selective Electrodes Using Conducting Polymers as Ion-to-Electron Transducers
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Demanding analytical applications such as on-line process analysis and clinical analysis require robust, reliable, and maintenance-free ion sensors of high potential stability. In this work the stability of the electrode potential of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers is critically evaluated by using chronopotentiometry and electrochemical impedance spectroscopy. This study is focused on the relationship between the potential stability of the electrode and the capacitance of the solid contact where ion-to-electron transduction takes place. The influence of this capacitance on the potential stability of all-solid-state ion-selective electrodes is studied experimentally by using conducting polymer layers of different thickness as solid contacts in potassium ion-selective electrodes based on a solvent polymeric membrane. Because of its excellent environmental stability, the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) is used as a model compound for the solid contact material. Chronopotentiometry is found to be a convenient and fast experimental method to critically evaluate the potential stability of different types of ion-selective electrodes.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Also, the high impedance nature of the ISE-based sensors37 required the use of high-impedance voltage buffers to ensure accurate open voltage measurement as intended.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [37]
Citations
Cites
Handbook of conducting polymers
Skotheim, T. A., Elsenbaumer, R. L., & Reynolds, J. R. (1986) · M. Dekker eBooks · Cited by 8,079
Poly(alkylenedioxythiophene)s—new, very stable conducting polymers
Heywang, G., & Jonas, F. (1992) · Advanced Materials · doi:10.1002/adma.19920040213 · Cited by 1,027
Cadogan, A., Gao, Z., Lewenstam, A., Ivaska, A., & Diamond, D. (1992) · Analytical Chemistry · doi:10.1021/ac00045a007 · Cited by 428
Coated wire ion-selective electrodes
Cattrall, R. W., & Freiser, H. (1971) · Analytical Chemistry · doi:10.1021/ac60307a032 · Cited by 387
Horvai, G., Graf, E., Toth, K., Pungor, E., & Buck, R. P. (1986) · Analytical Chemistry · doi:10.1021/ac00126a034 · Cited by 235
GUSTAFSSON, J., LIEDBERG, B., & INGANAS, O. (1994) · Solid State Ionics · doi:10.1016/0167-2738(94)90403-0 · Cited by 213
Technical applications for conductive polymers
Jonas, F., & Heywang, G. (1994) · Electrochimica Acta · doi:10.1016/0013-4686(94)e0057-7 · Cited by 202
Single-piece all-solid-state ion-selective electrode
Bobacka, J., Lindfors, T., McCarrick, M., Ivaska, A., & Lewenstam, A. (1995) · Analytical Chemistry · doi:10.1021/ac00116a034 · Cited by 188
Self-citationBobacka, J., McCarrick, M., Lewenstam, A., & Ivaska, A. (1994) · The Analyst · doi:10.1039/an9941901985 · Cited by 175
Self-citationCharacterization of electroactive polymer layers by electrochemical impedance spectroscopy (EIS)
Musiani, M. M. (1990) · Electrochimica Acta · doi:10.1016/0013-4686(90)80023-h · Cited by 148
Research works printed but not linked: 7
- Nikolskii B. P., 1985, Ion-Sel. Electrode Rev., 7, 39
- Buck R. P., 1976, Anal. Chem., 48, 39R
- Momma T., 1995, Sens. Acuators, B, 24, 728
- Pandey P. C., 1998, Sens. Actuators, B, 46, 65
- Glarum S. H., 1987, J. Electrochem. Soc., 134, 147
- Bobacka J., 1991, Synth. Met., 44, 34
- Koryta, J.; Dvorak, J.; Kavan, L. Principles of Electrochemistry , 2nd ed.; Wiley: Chichester, U.K., 1993; p 38.
Cited by
Items 301–400 of 686
Forrest, T., Zdrachek, E. A., & Bakker, E. (2019) · Electroanalysis · doi:10.1002/elan.201900674 · Cited by 28
Coulometric response characteristics of solid contact ion-selective electrodes for divalent cations
Han, T., Mousavi, Z., Mattinen, U., & Bobacka, J. (2020) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-020-04718-8 · Cited by 28
Self-citationJiang, T., Qi, L., Hou, C., Fang, S., & Qin, W. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c03099 · Cited by 28
Highly stable Li+ selective electrode with metal-organic framework as ion-to-electron transducer
Abdollahzadeh, M., Bayatsarmadi, B., Vepsäläinen, M., Razmjou, A., & Asadnia, M. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.130799 · Cited by 27
Problems and prospects of solid contact ion-selective electrodes with ionophore-based membranes
Ivanova, N. M., Levin, M. B., & Mikhelson, K. N. (2012) · Russian Chemical Bulletin · doi:10.1007/s11172-012-0136-0 · Cited by 28
Komaba, S., Akatsuka, T., Ohura, K., Suzuki, C., Yabuuchi, N., Kanazawa, S., Tsuchiya, K., & Hasegawa, T. (2017) · The Analyst · doi:10.1039/c7an01068k · Cited by 27
Miniature Multi-Ion Sensor Integrated With Artificial Neural Network
Chen, Y., Tang, Z., Zhu, Y., Castellano, M. J., & Dong, L. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3117573 · Cited by 28
“But, these sensors suffer from a signal drift and instability over time because there is an issue with chloride leaching from silver/silver chloride (Ag/AgCl)-based pseudo reference electrodes (REs) due to the redox reaction occurring at these REs [26].”
BackgroundHe, N., Höfler, L., Latonen, R., & Lindfors, T. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.10.048 · Cited by 27
Wang, T., Xu, Z., Huang, Y., Dai, Z., Wang, X., Lee, M., Bagtzoglou, C., Brückner, C., Lei, Y., & Li, B. (2020) · Environmental Research · doi:10.1016/j.envres.2020.109891 · Cited by 27
Toczyłowska‐Mamińska, R., Pokrop, R., Dybko, A., & Wróblewski, W. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.09.002 · Cited by 27
Application of Metal Oxide Nanoparticles in the Field of Potentiometric Sensors: A Review
Lenar, N., Piech, R., Wardak, C., & Paczosa‐Bator, B. (2023) · Membranes · doi:10.3390/membranes13110876 · Cited by 29
“When talking about conducting polymers, the following polymers should also be mentioned: poly(3-octylthiophene) (POT) [25], poly(aniline) (PANI) [26], poly(3,4-ethylene-1,4-dioxythiophene) (PEDOT) [27], and PEDOT doped with other ions: PEDOT(PSS) and PEDOT(Cl) [27].”
BackgroundHua, Y., Mai, J., Su, R., Ma, C., Liu, J., Zhao, C., Zhang, Q., Liao, C., & Wang, Y. (2024) · Biosensors · doi:10.3390/bios14120617 · Cited by 26
“As shown in clear difference in potential response was observed between the bare carbon ISM The bare carbon ISM exhibited significant potential drift during the final 20 h period, whereas the MOF/rGO ISM maintained a stable potential response without drift.”
Kamel, A. H., Amr, A. E. E., Abdalla, N. S., El-Naggar, M. H., Al-Omar, M. A., Alkahtani, H. M., & Sayed, A. Y. A. (2019) · Polymers · doi:10.3390/polym11111796 · Cited by 26
“According to the equation, ΔE/Δt = I/CL proposed by Bobacka [44], the low-frequency capacitance (CL) for GC/PANI-MIP/ FLU--ISE and GC/PANIaliquat/FLU--ISE was calculated to be 86.2 ± 2.3 and 25.4 ± 0.9 μF, respectively.”
BackgroundInfluentialMagnus Berggren, A., Forchheimer, R., Bobacka, J., Svensson, P. O., Nilsson, D., Larsson, O., & Ivaska, A. U. (2008) · Springer eBooks · doi:10.1007/978-3-540-76314-7_9 · Cited by 26
Self-citationLisak, G., Wagner, M., Kvarnström, C., Bobacka, J., Ivaska, A. U., & Lewenstam, A. (2010) · Electroanalysis · doi:10.1002/elan.201000459 · Cited by 26
Self-citationFenoy, G. E., Giussi, J. M., von Bilderling, C., Maza, E., Pietrasanta, L. I., Knoll, W., Marmisollé, W. A., & Azzaroni, O. (2018) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2018.02.014 · Cited by 26
Hassan, S. S. M., Kamel, A. H., Amr, A. E. E., Fathy, M. A., & Al-Omar, M. A. (2020) · Molecules · doi:10.3390/molecules25030629 · Cited by 26
“To evaluate the short‐term potential stability of the developed paper based sensors, chronopotentiograms were recorded under a constant current of ±1 nA and the results are shown in (Figure 4) [33].”
MethodKamel, A. H., Ezzat, S., Ahmed, M. A., Amr, A. E. E., Almehizia, A. A., & Al-Omar, M. A. (2020) · Biomolecules · doi:10.3390/biom10020251 · Cited by 26
“According to Bobacka’s group [24], chronopotentiometry measurements (CP) of the proposed sensor based MIP were applied in a solution of 9.”
MethodFluorimetric readout of ion-selective electrode potential changes
Jaworska, E., Michalska, A., & Maksymiuk, K. (2018) · Electrochimica Acta · doi:10.1016/j.electacta.2018.07.130 · Cited by 25
Kamel, A. H., Amr, A. E. E., Ashmawy, N. H., Galal, H. R., Al-Omar, M. A., & Sayed, A. Y. A. (2020) · Polymers · doi:10.3390/polym12061406 · Cited by 24
“The potential stability of the solid-contact sensors using PEDOT/PSS is critically evaluated by using constant-current chronopotentiometry [45].”
MethodA miniature all-solid-state calcium electrode applied to in situ seawater measurement
Xu, H., Wang, Y., Luo, Z., & Pan, Y. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/12/125105 · Cited by 25
Pięk, M., Paczosa‐Bator, B., Smajdor, J., & Piech, R. (2018) · Electrochimica Acta · doi:10.1016/j.electacta.2018.07.121 · Cited by 25
Krikstolaityte, V., Ding, R., Ruzgas, T. A., Björklund, S., & Lisak, G. (2020) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.06.044 · Cited by 25
Pawłowski, P., Michalska, A., & Maksymiuk, K. (2006) · Electroanalysis · doi:10.1002/elan.200603553 · Cited by 25
Imali, D. Y., Perera, E. C. J., Kaumal, M. N., & Dissanayake, D. P. (2024) · RSC Advances · doi:10.1039/d4ra02615b · Cited by 28
Liu, Y., Zeng, X., Waterhouse, G. I. N., Jiang, X., Zhang, Z., & Yu, L. (2021) · Synthetic Metals · doi:10.1016/j.synthmet.2021.116898 · Cited by 24
Advantages of Amperometric Readout Mode of Ion‐selective Electrodes under Potentiostatic Conditions
Jaworska, E., Pawłowski, P., Michalska, A., & Maksymiuk, K. (2018) · Electroanalysis · doi:10.1002/elan.201800649 · Cited by 24
Kakroudi, M. R., Bailey, B. A., Autrey, C., Ferrer, K., Vantoorenburg, B., Patel, P. K., Calvo‐Marzal, P., & Chumbimuni‐Torres, K. Y. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04506 · Cited by 24
Sun, X. X. (2002) · Talanta · doi:10.1016/s0039-9140(02)00292-8 · Cited by 24
Miniature planar chloride electrodes
Paciorek, R., Bieganowski, P., & Maj‐Żurawska, M. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.11.071 · Cited by 24
Nam, H., Cha, G. S., Strong, T. D., Ha, J., Sim, J. H., Hower, R. W., Martin, S. M., & Brown, R. B. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.813581 · Cited by 24
Abdalla, N. S., Amr, A. E. E., El‐Tantawy, A. S. M., Al-Omar, M. A., Kamel, A. H., & Khalifa, N. M. (2019) · Polymers · doi:10.3390/polym11091526 · Cited by 23
“Chronopotentiometric technique was used to evaluate the short-term potential stability of the developed PANI nanoc posite [48].”
MethodAll solid-state miniaturized potentiometric sensors for flunitrazepam determination in beverages
Tantawy, M. A., Mohamed, E. H., & Yehia, A. M. (2021) · Microchimica Acta · doi:10.1007/s00604-021-04851-9 · Cited by 23
Amirghasemi, F., Soleimani, A., Bawarith, S., Tabassum, A., Morrel, A., & Mousavi, M. P. S. (2023) · Bioengineering · doi:10.3390/bioengineering10060655 · Cited by 25
“First, we considered the correlation between the potential drift and the capacitance at the interface of the ion-selective membrane and the ion-to-electron transducer based on Equation (3), and we performed a chronopotentiometry experiment [72], where we applied a perturbation current of ±1 nA to the system and record…”
Al‐Shami, A., Amirghasemi, F., Soleimani, A., Nejad, S. K., Ong, V., Berkmen, A., Ainla, A., & Mousavi, M. P. S. (2024) · Small · doi:10.1002/smll.202311745 · Cited by 25
Ivanova, N. M., Podeshvo, I. V., Goikhman, M. Y., Yakimanskii, A. V., & Mikhelson, K. N. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.06.072 · Cited by 23
Kozma, J., Papp, S., & Gyurcsányi, R. E. (2021) · Electrochemistry Communications · doi:10.1016/j.elecom.2020.106903 · Cited by 23
Sun, X. X., Zhang, X., & Aboul-Enein, H. Y. (2004) · Il Farmaco · doi:10.1016/j.farmac.2003.09.002 · Cited by 23
Zeng, H., Ren, G., Gao, N., Xu, T., Jin, P., Yin, Y., Liu, R., Zhang, S., Zhang, M., & Mao, L. (2024) · Angewandte Chemie International Edition · doi:10.1002/anie.202407063 · Cited by 23
Ion Transfer Voltammetry at Thin Films Based on Functionalized Cationic [6]Helicenes
Jarolímová, Z., Bosson, J., Labrador, G. M., Lacour, J., & Bakker, E. (2017) · Electroanalysis · doi:10.1002/elan.201700669 · Cited by 22
Cost-effective and handmade paper-based potentiometric sensing platform for piperidine determination
Kamel, A. H., Galal, H. R., & Awwad, N. S. (2018) · Analytical Methods · doi:10.1039/c8ay01811a · Cited by 22
Development of Miniature Solid Contact Ion Selective Electrodes for in situ Instrumentation
Jaramillo, E. A., & Noell, A. C. (2020) · Electroanalysis · doi:10.1002/elan.201900761 · Cited by 25
Abd‐Rabboh, H. S. M., Amr, A. E. E., Almehizia, A. A., & Kamel, A. H. (2021) · Polymers · doi:10.3390/polym13081192 · Cited by 22
“Short-term potential stability of the SPE/MWCNTs/MIP-ISE was evaluated by carrying out chronopotentiometric measurements in 10 mM PHO solution according to the method presented by Bobacka [58].”
MethodPerchlorate Solid-Contact Ion-Selective Electrode Based on Dodecabenzylbambus[6]uril
Itterheimová, P., Bobacka, J., Šindelář, V., & Lubal, P. (2022) · Chemosensors · doi:10.3390/chemosensors10030115 · Cited by 22
Self-citationLi, Y., Li, J., & Qin, W. (2022) · Talanta · doi:10.1016/j.talanta.2022.123797 · Cited by 22
Polypyrrole Nanoparticles Based Disposable Potentiometric Sensors
Jaworska, E., Gniadek, M., Maksymiuk, K., & Michalska, A. (2017) · Electroanalysis · doi:10.1002/elan.201700441 · Cited by 22
Zhao, G., Ding, J., & Qin, W. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.04.059 · Cited by 22
Low-cost flexible laminated graphene paper solid-contact ion-selective electrodes
Rutkowska, M., Lindfors, T., Boeva, Z. A., & Strawski, M. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.129808 · Cited by 23
Eldin, A. G., Amr, A. E. E., Kamel, A. H., & Hassan, S. S. M. (2019) · Molecules · doi:10.3390/molecules24071392 · Cited by 21
“The potential stability of the proposed sensors was evaluated by using constant current chronopotentiometric measurements [33].”
MethodChoi, K. R., Chen, X. V., Hu, J., & Bühlmann, P. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c03985 · Cited by 21
Shahzad, U., Saeed, M., Marwani, H. M., Al‐Humaidi, J. Y., Rehman, S. U., Althomali, R. H., Awual, M. R., & Rahman, M. M. (2024) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2024.2337876 · Cited by 26
“[31] Also, to be mentioned while discussing conducting polymers are poly(3,4-ethylene-1,4-dioxythiophene) (PEDOT), [32] pol-y(aniline) (PANI), [33] and PEDOT incapacitated with different ionic species, such as PEDOT(PSS) and PEDOT(Cl).”
Dithizone Modified Gold Nanoparticles Films as Solid Contact for Cu2+ Ion‐Selective Electrodes
Woźnica, E., Wójcik, M., Mieczkowski, J. B., Maksymiuk, K., & Michalska, A. (2012) · Electroanalysis · doi:10.1002/elan.201200385 · Cited by 21
Kerric, G., Parra, E. J., Crespo, G. A., Rius, F. X., & Blondeau, P. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm33153e · Cited by 22
A Solid-Contact Indium(III) Sensor based on a Thiosulfinate Ionophore Derived from Omeprazole
Abbas, M. N., & Magar, H. S. (2013) · Bulletin of the Korean Chemical Society · doi:10.5012/bkcs.2013.34.4.1153 · Cited by 21
An all-solid-state imprinted polymer-based potentiometric sensor for determination of bisphenol S
Wang, T., Liang, R., Yin, T., Yao, R., & Qin, W. (2016) · RSC Advances · doi:10.1039/c6ra14461f · Cited by 21
Jaworska, E., Kisiel, A., Michalska, A., & Maksymiuk, K. (2017) · Electroanalysis · doi:10.1002/elan.201700685 · Cited by 21
Jarolímová, Z., Bosson, J., Labrador, G. M., Lacour, J., & Bakker, E. (2018) · Electroanalysis · doi:10.1002/elan.201800080 · Cited by 21
Lenar, N., Paczosa‐Bator, B., & Piech, R. (2019) · Journal of The Electrochemical Society · doi:10.1149/2.0481915jes · Cited by 21
Li, J., & Qin, W. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.105453 · Cited by 21
Paczosa‐Bator, B., Cabaj, L., Pięk, M., Piech, R., & Kubiak, W. W. (2015) · Analytical Letters · doi:10.1080/00032719.2015.1045594 · Cited by 21
“In order to assess the electrode potential stability and capacity of the solid contact of the developed electrodes, current reversal chronopotentiometry was used (Bobacka 1999).”
BackgroundMethodInfluentialDisposable Miniaturized Screen‐Printed pH and Reference Electrodes for Potentiometric Systems
Musa, A. E., del Campo, F. J., Abramova, N., Alonso‐Lomillo, M. A., Domínguez‐Renedo, O., Arcos‐Martínez, M. J., Brivio, M., Snakenborg, D., Geschke, O., & Kutter, J. P. (2010) · Electroanalysis · doi:10.1002/elan.201000443 · Cited by 21
An, Q., Jiao, L., Jia, F., Ye, J., Li, F., Gan, S., Zhang, Q., Ivaska, A. U., & Niu, L. (2016) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2016.10.053 · Cited by 22
Pięk, M., Fendrych, K., Smajdor, J., Piech, R., & Paczosa‐Bator, B. (2017) · Talanta · doi:10.1016/j.talanta.2017.03.068 · Cited by 21
Yang, Q., Zhang, M., Chen, M., Liu, G., & Wang, M. (2019) · International Journal of Electrochemical Science · doi:10.20964/2019.06.45 · Cited by 20
Dębosz, M., Kozma, J., Porada, R., Wieczorek, M., Paluch, J., Gyurcsányi, R. E., Migdalski, J., & Kościelniak, P. (2021) · Talanta · doi:10.1016/j.talanta.2021.122491 · Cited by 22
Ganjali, M. R., Rezapour, M., Pirali‐Hamedani, M., & Rashedi, H. (2015) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)17319-6 · Cited by 20
Kaya, İ., & Aydın, A. (2011) · Progress in Organic Coatings · doi:10.1016/j.porgcoat.2011.11.008 · Cited by 20
Bandi, K. R., Singh, A. K., Kamaluddin, K., Jain, A. K., & Gupta, V. K. (2011) · Electroanalysis · doi:10.1002/elan.201100461 · Cited by 20
Polypyrrole Microcapsules in All‐solid‐state Reference Electrodes
Kisiel, A., Kijewska, K., Mazur, M., Maksymiuk, K., & Michalska, A. (2011) · Electroanalysis · doi:10.1002/elan.201100551 · Cited by 20
Jaworska, E., Michalska, A., & Maksymiuk, K. (2016) · Electroanalysis · doi:10.1002/elan.201600554 · Cited by 20
Dualism of Sensitivity and Selectivity of Porphyrin Dimers in Electroanalysis
Lisak, G., Tamaki, T., & Ogawa, T. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04179 · Cited by 20
Hassan, S. S. M., Eldin, A. G., Amr, A. E. E., Al-Omar, M. A., & Kamel, A. H. (2019) · Sensors · doi:10.3390/s19122697 · Cited by 20
Gyetvai, G., Nagy, L., Ivaska, A. U., Hernádi, I., & Nagy, G. (2009) · Electroanalysis · doi:10.1002/elan.200904617 · Cited by 20
MARCO, R. D., Jiang, Z., Martizano, J. O., Lowe, A., Pejcic, B., & van Riessen, A. (2006) · Electrochimica Acta · doi:10.1016/j.electacta.2006.03.030 · Cited by 20
Silva, R., Zhao, K., Ding, R., Chan, W. P., Yang, M., Yip, J. S. Q., & Lisak, G. (2022) · The Analyst · doi:10.1039/d2an01108e · Cited by 19
Solid Contact Ion-Selective Electrodes for in Situ Measurements at High Pressure
Weber, A. W., O’Neil, G. D., & Kounaves, S. P. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00366 · Cited by 19
Hassan, S. S. M., Abdelbasir, S. M., Fathy, M. A., Amr, A. E. E., Al-Omar, M. A., & Kamel, A. H. (2019) · Nanomaterials · doi:10.3390/nano9081160 · Cited by 19
“Using the method provided by Bobacka [56], the membrane resistance and capacitance of the ISE can be calculated.”
MethodKamel, A. H., Amr, A. E. E., Galal, H. R., Al-Omar, M. A., & Almehizia, A. A. (2020) · Chemosensors · doi:10.3390/chemosensors8030086 · Cited by 19
“Short-term potential stability for the proposed sensors can be evaluated using the method proposed by Bobacka 1999 [48].”
MethodMao, C., Yuan, D., Wang, L., & Bakker, E. (2020) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2020.114800 · Cited by 19
Effect of Monomer Modifications on the Physical Properties of Electropolymerised PEDOT Films
Sulaiman, Y., & Kataky, R. (2011) · Journal of The Electrochemical Society · doi:10.1149/2.019202jes · Cited by 19
Low cost, calibration-free sensors for in situ determination of natural water pollution
Radu, A., Anastasova, S., Fay, C., Diamond, D., Bobacka, J., & Lewenstam, A. (2010) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2010.5690357 · Cited by 19
“For this study, we have chosen PEDOT from the numerous CPs available due to its low oxidation potential, low band gap (~2 eV) and good stability in the oxidized state [8,9].”
MethodSelf-citationLiu, S., Yin, T., Li, Z., & Wang, J. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.135269 · Cited by 18
Kim, M., Dong, X. I. N., Spindler, B. D., Bühlmann, P., & Stein, A. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.4c00373 · Cited by 18
Electrochemical supercapacitors of PANI/MWCNT, PEDOT/MWCNT and P(ANI-co-EDOT)/MWCNT nanocomposites
Ateş, M., Serin, M. A., & Calisskan, S. (2018) · Polymer Bulletin · doi:10.1007/s00289-018-2539-z · Cited by 18
Rectifying effect for ion-selective electrodes with conducting polymer solid contact
Kisiel, A., Michalska, A., & Maksymiuk, K. (2018) · Synthetic Metals · doi:10.1016/j.synthmet.2018.10.019 · Cited by 18
Phytic acid@Ag-based all-solid-state ion selective electrode for potentiometric detection of Cu2+
Wang, Z., Tang, W., Yu, J., Zhang, F., & He, P. (2019) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2019.01.031 · Cited by 18
Molecularly imprinted conducting polymer for determination of a condensed lignin marker
Gonzalez-Vogel, A., Fogde, A., Crestini, C., Sandberg, T., Huynh, T., & Bobacka, J. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.05.011 · Cited by 18
Self-citationZavolskova, M., Nikitina, V. N., Maksimova, E. D., Karyakina, E. E., & Karyakin, A. A. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b00934 · Cited by 18
Ivanko, I., Lindfors, T., Emanuelsson, R., & Sjödin, M. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.129231 · Cited by 19
Ding, R., Cheong, Y. H., Zhao, K., & Lisak, G. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.130567 · Cited by 18
Jiang, W., Liu, C., Zhao, Y., Waterhouse, G. I. N., Zhang, Z., & Yu, L. (2019) · Synthetic Metals · doi:10.1016/j.synthmet.2019.01.008 · Cited by 18
Hassan, S. S. M., & Fathy, M. A. (2024) · Microchimica Acta · doi:10.1007/s00604-024-06494-y · Cited by 18
“4 and 5 [57]. where ΔE, I, R b , Δt, and C represent the potential change, applied current (1 nA), bulk membrane resistance, time variation and redox capacitance, respectively.”
Han, T., Kalinichev, A. V., Mousavi, Z., Mikhelson, K. N., & Bobacka, J. (2022) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2022.131416 · Cited by 17
Self-citationTamara, M. R., Lelono, D., Roto, R., & Trıyana, K. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114170 · Cited by 17
Wardak, C., Pietrzak, K., & Morawska, K. (2023) · Applied Nanoscience · doi:10.1007/s13204-023-02846-x · Cited by 17
“The use of solid contact greatly facilitates the processes of charge transfer between the solid electrode material and the ion-selective membrane, which results in lowering the membrane resistance and charge transfer resistance and increasing the double layer capacitance (Bobacka 1999).”
BackgroundAmirghasemi, F., Al‐Shami, A., Ushijima, K., & Mousavi, M. P. S. (2024) · ACS Materials Letters · doi:10.1021/acsmaterialslett.4c00825 · Cited by 17
Pawłowski, P., Kisiel, A., Michalska, A., & Maksymiuk, K. (2011) · Talanta · doi:10.1016/j.talanta.2011.02.018 · Cited by 17
Pięk, M., Piech, R., & Paczosa‐Bator, B. (2016) · Journal of The Electrochemical Society · doi:10.1149/2.0341613jes · Cited by 17
Kałuża, D., Michalska, A., & Maksymiuk, K. (2021) · ChemElectroChem · doi:10.1002/celc.202100892 · Cited by 17
Zhai, J., Zhang, Y., Zhao, D., Kou, L., & Zhao, G. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.339209 · Cited by 17
Metadata
- Authors
- Bobacka, J.
- Affiliations
- Åbo Akademi University (FI)
- Corresponding author
- Bobacka, Johan
- ORCID
- Bobacka, Johan
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-10-01
- Volume
- 71
- Issue
- 21
- Pages
- 4932-4937
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2000694408
- Cited by
- 686
- References
- 34
- Citations by year
- 2026: 29 · 2025: 33 · 2024: 54 · 2023: 39 · 2022: 46 · 2021: 49 · 2020: 47 · 2019: 51 · 2018: 33 · 2017: 28 · 2016: 23 · 2015: 23 · 2014: 23 · 2013: 19 · 2012: 25
- FWCI
- 4.77
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Åbo Akademi University Research Portal (submittedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- potential stability, conducting polymers, ion-to-electron transduction, PEDOT, potassium ion-selective electrode, chronopotentiometry, electrochemical impedance spectroscopy, solvent polymeric membranes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.