Simulations of the Frequency Response of Implantable Glucose Sensors

Jablecki, Michael, Gough, David A.·2000·Analytical Chemistry

Abstract

The response of enzyme electrode glucose sensors implanted in tissues to physiologic blood glucose oscillations is simulated. Models describe both oxygen-based and peroxide-based glucose sensors in spatially homogeneous medium simulating some mass transfer properties of tissue. Pass-through ratios and delays are reported as a function of frequency for the oxygen-based sensor, and the effects on continuous blood glucose monitoring are illustrated using data from the literature. Certain peroxide-based sensor designs may produce common signals for different glucose concentrations, a characteristic not found in oxygen-based sensors. The dynamic response depends on the frequency of glucose oscillation and is sensitive to sensor type, enzyme activity, and diffusional resistance.

Integrity signals

Registry

Crossref · 10.1021/ac991018z

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Jablecki and Gough's simulations concluded that increased mass transfer would increase lag and could potentially reduce the magnitude and differences when glucose sensor signals fluctuate between high and low.

    “Simulations of glucose concentration oscillations by Jablecki and Gough concluded that increases in mass transfer would increase lag and could potentially decrease the magnitude and differences when fluctuating between high and low glucose sensor signals.110”
  • The positive correlation between lag time and capsule thickness supported the models described above.

    “The positive correlation between lag time and capsule thickness supported the models described above.107,110–111”
  • The increases in mass transfer in those simulations were not attributed to any specific part of the FBR and could arise from collagen capsule thickness, blood vessel density, or other unanticipated factors.

    “the increases to mass transfer were not attributed to any specific part of the FBR and could originate from collagen capsule thickness, blood vessel density, or other unanticipated factors.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Jablecki, M., & Gough, D. A.
Affiliations
University of California San Diego (US)
Corresponding author
Gough, David A.
Venue
Analytical Chemistry
Published
2000-03-17
Volume
72
Issue
8
Pages
1853-1859
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1971946532
Cited by
24
References
22
Citations by year
2019: 1 · 2017: 2 · 2015: 1 · 2013: 2 · 2012: 1
FWCI
0.86
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institutes of Health
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
implantable glucose sensor, frequency response, continuous glucose monitoring, sensor delay, diffusion resistance, sensor modeling
MeSH terms
Algorithms, Blood Glucose, Computer Simulation, Models, Biological, Biosensing Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review