Increased In Vivo Glucose Recovery via Nitric Oxide Release
Open accessAbstract
The in vivo glucose recovery of subcutaneously implanted nitric oxide (NO)-releasing microdialysis probes was evaluated in a rat model using saturated NO solutions to steadily release NO. Such methodology resulted in a constant NO flux of 162 pmol cm(-2) s(-1) from the probe membrane over 8 h of perfusion daily. The in vivo effects of enhanced localized NO were evaluated by monitoring glucose recovery over a 14 day period, with histological analysis thereafter. A difference in glucose recovery was observed starting at 7 days for probes releasing NO relative to controls. Histological analysis at 14 days revealed lessened inflammatory cell density at the probe surface and decreased capsule thickness. Collectively, the results suggest that intermittent sustained NO release from implant surfaces may improve glucose diffusion for subcutaneously implanted sensors by mitigating the foreign body reaction.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Nitric oxide-releasing microdialysis probes after 7 days recovered larger glucose concentrations compared to controls, indicating lower resistance to mass transfer in the surrounding tissue.
“The NO-releasing probes after 7 d were reported to recover larger glucose concentrations compared to controls (Figure 4), indicating lower resistance to mass transfer in the surrounding tissue.”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [239]
The authors concluded that the mitigated foreign body response by nitric oxide release was at least partially responsible for the superior glucose recovery.
“The authors concluded that the mitigated FBR by NO release was thus at least partially responsible for the superior glucose recovery.”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [239]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Theory and Practice of Histological Techniques
Bancroft, J. D., & Gamble, M. (1990) · Cited by 6,986 · see citing works
Theory and Practice of Histological Techniques
Goss, G. R. (2009) · The American Journal of Surgical Pathology · doi:10.1097/pas.0b013e3181805089 · Cited by 5,454 · see citing works
Nitric oxide and the immune response
Bogdan, C. (2001) · Nature Immunology · doi:10.1038/ni1001-907 · Cited by 3,447 · see citing works
Biomaterials: Where We Have Been and Where We Are Going
Ratner, B. D., & Bryant, S. J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140027 · Cited by 1,507 · see citing works
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660 · see citing works
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543 · see citing works
Steady-state theory for quantitative microdialysis of solutes and water in vivo and in vitro
Bungay, P. M., Morrison, P. F., & Dedrick, R. L. (1990) · Life Sciences · doi:10.1016/0024-3205(90)90043-q · Cited by 507 · see citing works
Enzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434 · see citing works
Nitric oxide and wound repair: role of cytokines?
Schwentker, A., Vodovotz, Y., Weller, R., & Billiar, T. R. (2002) · Nitric Oxide · doi:10.1016/s1089-8603(02)00002-2 · Cited by 386 · see citing works
The foreign body reaction: A chronic inflammatory response
Coleman, D. L., King, R. N., & Andrade, J. D. (1974) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820080503 · Cited by 289 · see citing works
Nitric Oxide Regulates Wound Healing
Schäffer, M. R., Tantry, U. S., Gross, S. S., Wasserkrug, H. L., & Barbul, A. (1996) · Journal of Surgical Research · doi:10.1006/jsre.1996.0254 · Cited by 279 · see citing works
Reducing capsular thickness and enhancing angiogenesis around implant drug release systems
Ratner, B. D. (2002) · Journal of Controlled Release · doi:10.1016/s0168-3659(01)00502-8 · Cited by 271 · see citing works
Nitric oxide, an autocrine regulator of wound fibroblast synthetic function
Schäffer, M. R., Efron, P. A., Thornton, F. J., Klingel, K., Gross, S. S., & Barbul, A. (1997) · The Journal of Immunology · doi:10.4049/jimmunol.158.5.2375 · Cited by 260 · see citing works
THE VASCULAR BIOLOGY OF NITRIC OXIDE AND ITS ROLE IN ATHEROGENESIS
Lloyd‐Jones, D. M., & Bloch, K. D. (1996) · Annual Review of Medicine · doi:10.1146/annurev.med.47.1.365 · Cited by 243 · see citing works
Long-term engraftment of hepatocytes transplanted on biodegradable polymer sponges
Mooney, D. J., Sano, K., Kaufmann, P. M., Majahod, K., Schloo, B. L., Vacanti, J. P., & Langer, R. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19971205)37:3 · Cited by 233 · see citing works
Self-citationMowery, K. A., H. Schoenfisch, M., Saavedra, J. E., Keefer, L. K., & Meyerhoff, M. E. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00127-1 · Cited by 219 · see citing works
Self-citationKoschwanez, H. E., & Reichert, W. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.034 · Cited by 181 · see citing works
Inhibition of implant-associated infections via nitric oxide release
Nablo, B. J., Prichard, H. L., Butler, R. D., Klitzman, B. M., & Schoenfisch, M. H. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.05.017 · Cited by 176 · see citing works
Self-citationBungay, P. M., Newton‐Vinson, P., Isele, W., Garris, P. A., & Justice, J. B. (2003) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.2003.01904.x · Cited by 173 · see citing works
Reduced foreign body response at nitric oxide-releasing subcutaneous implants
Hetrick, E. M., Prichard, H. L., Klitzman, B., & Schoenfisch, M. H. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.06.036 · Cited by 158 · see citing works
Self-citationImplantable chemical sensors for real-time clinical monitoring: progress and challenges
Frost, M. C., & Meyerhoff, M. E. (2002) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(02)00371-x · Cited by 148 · see citing works
Thornton, F. J., Schäffer, M. R., Witte, M. B., Moldawer, L. L., MacKay, S. L. D., Abouhamze, A. S., Tannahill, C. L., & Barbul, A. (1998) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.1998.8681 · Cited by 146 · see citing works
Methods and issues in microdialysis calibration
Stenken, J. A. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(98)00598-4 · Cited by 129 · see citing works
Norton, L. W., Koschwanez, H. E., Wisniewski, N. A., Klitzman, B., & Reichert, W. M. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31088 · Cited by 128 · see citing works
Self-citationSchoenfisch, M. H., Mowery, K. A., Rader, M. V., Baliga, N., Wahr, J. A., & Meyerhoff, M. E. (2000) · Analytical Chemistry · doi:10.1021/ac991370c · Cited by 121 · see citing works
Self-citationWisniewski, N., Klitzman, B. M., Miller, B., & Reichert, W. M. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20011215)57:4 · Cited by 120 · see citing works
Self-citationProtein interactions with subcutaneously implanted biosensors
Gifford, R., Kehoe, J. J., Barnes, S. L., Kornilayev, B. A., Alterman, M. A., & Wilson, G. S. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.033 · Cited by 117 · see citing works
Lowry, J. P., O'Neill, R. D., Boutelle, M. G., & Fillenz, M. (1998) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.1998.70010391.x · Cited by 105 · see citing works
S‐nitrosoglutathione‐containing hydrogel accelerates rat cutaneous wound repair
Amadeu, T. P., Seabra, A. B., Oliveira, M. D., & Monte‐Alto‐Costa, A. (2007) · Journal of the European Academy of Dermatology and Venereology · doi:10.1111/j.1468-3083.2006.02032.x · Cited by 105 · see citing works
Hetrick, E. M., & Schoenfisch, M. H. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.01.006 · Cited by 104 · see citing works
Self-citationFischer, U., Ertle, R., Abel, P., Rebrin, K., Brunstein, E., von Dorsche, H. H., & Freyse, E. (1987) · Diabetologia · doi:10.1007/bf00295878 · Cited by 104 · see citing works
Mediation of <i>in vivo</i> glucose sensor inflammatory response via nitric oxide release
Gifford, R., Batchelor, M. M., Lee, Y., Gokulrangan, G., Meyerhoff, M. E., & Wilson, G. S. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30359 · Cited by 96 · see citing works
Koschwanez, H. E., Yap, F. Y., Klitzman, B., & Reichert, W. M. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31824 · Cited by 69 · see citing works
Self-citationRosdahl, H. G., Lind, L., Millgård, J., Lithell, H., Ungerstedt, U., & Henriksson, J. (1998) · Diabetes · doi:10.2337/diabetes.47.8.1296 · Cited by 49 · see citing works
Stenken, J. A., Lunte, C. E., Southard, M. Z., & Ståhle, L. (1997) · Journal of Pharmaceutical Sciences · doi:10.1021/js960269+ · Cited by 48 · see citing works
Badie, N., Satterwhite, L. L., & Bursac, N. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9815-x · Cited by 48 · see citing works
Study of the effects of tissue reactions on the function of implanted glucose sensors
Dungel, P., Long, N., Yu, B., Moussy, Y., & Moussy, F. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31593 · Cited by 47 · see citing works
Ward, W. K., Wood, M. D., Casey, H. M., Quinn, M. J., & Federiuk, I. F. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504773731320 · Cited by 39 · see citing works
Long-term calibration considerations during subcutaneous microdialysis sampling in mobile rats
Mou, X., Lennartz, M. R., Loegering, D. J., & Stenken, J. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.02.016 · Cited by 33 · see citing works
Wang, X., Lennartz, M. R., Loegering, D. J., & Stenken, J. A. (2007) · Analytical Chemistry · doi:10.1021/ac061503b · Cited by 26 · see citing works
Kurosawa, M., Hallström, Å., & Ungerstedt, U. (1991) · Neuroscience Letters · doi:10.1016/0304-3940(91)90534-z · Cited by 24 · see citing works
Simulations of the Frequency Response of Implantable Glucose Sensors
Jablecki, M., & Gough, D. A. (2000) · Analytical Chemistry · doi:10.1021/ac991018z · Cited by 24 · see citing works
Stenken, J. A., Reichert, W. M., & Klitzman, B. M. (2002) · Analytical Chemistry · doi:10.1021/ac020234w · Cited by 10 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347 · see citing works
Self-citationAdvances in wearable chemical sensor design for monitoring biological fluids
Matzeu, G., Florea, L., & Diamond, D. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.01.077 · Cited by 304 · see citing works
Hydrogen Peroxide Generation and Biocompatibility of Hydrogel-Bound Mussel Adhesive Moiety
Meng, H., Li, Y.-T., Faust, M., Konst, S., & Lee, B. P. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.02.002 · Cited by 106 · see citing works
In Vivo Chemical Sensors: Role of Biocompatibility on Performance and Utility
Soto, R. J., Hall, J. R., Brown, M. D., Taylor, J. B., & Schoenfisch, M. H. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04251 · Cited by 85 · see citing works
Self-citationThe effect of nitric oxide surface flux on the foreign body response to subcutaneous implants
Nichols, S. P., Koh, A., Brown, N. L., Rose, M. B., Sun, B., Slomberg, D. L., Riccio, D. A., Klitzman, B., & Schoenfisch, M. H. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.05.053 · Cited by 67 · see citing works
Self-citationAvula, M., Rao, A. N., McGill, L. D., Grainger, D. W., & Solzbacher, F. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.12.056 · Cited by 67 · see citing works
Nitric Oxide-Releasing Silica Nanoparticle-Doped Polyurethane Electrospun Fibers
Koh, A., Carpenter, A. W., Slomberg, D. L., & Schoenfisch, M. H. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am402044s · Cited by 49 · see citing works
Self-citationIn Vivo Analytical Performance of Nitric Oxide-Releasing Glucose Biosensors
Soto, R. J., Privett, B. J., & Schoenfisch, M. H. (2014) · Analytical Chemistry · doi:10.1021/ac5017425 · Cited by 41 · see citing works
Self-citationGlucose Sensor Membranes for Mitigating the Foreign Body Response
Koh, A., Nichols, S. P., & Schoenfisch, M. H. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500505 · Cited by 41 · see citing works
Self-citationFabrication of nitric oxide-releasing polyurethane glucose sensor membranes
Koh, A., Riccio, D. A., Sun, B., Carpenter, A. W., Nichols, S. P., & Schoenfisch, M. H. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.06.005 · Cited by 37 · see citing works
Self-citationInfluence of diabetes on the foreign body response to nitric oxide-releasing implants
Soto, R. J., Merricks, E. P., Bellinger, D. A., Nichols, T. C., & Schoenfisch, M. H. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.11.044 · Cited by 34 · see citing works
Self-citationLong-Term Accurate Continuous Glucose Biosensors via Extended Nitric Oxide Release
Malone‐Povolny, M. J., Merricks, E. P., Wimsey, L. E., Nichols, T. C., & Schoenfisch, M. H. (2019) · ACS Sensors · doi:10.1021/acssensors.9b01779 · Cited by 31 · see citing works
Self-citationSoto, R. J., Schofield, J. B., Walter, S. E., Malone‐Povolny, M. J., & Schoenfisch, M. H. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00623 · Cited by 31 · see citing works
Self-citationLocal release of masitinib alters in vivo implantable continuous glucose sensor performance
Avula, M., Jones, D., Rao, A. N., McClain, D. A., McGill, L. D., Grainger, D. W., & Solzbacher, F. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.059 · Cited by 26 · see citing works
Nitric oxide release for improving performance of implantable chemical sensors – A review
Cha, K. H., Wang, X., & Meyerhoff, M. E. (2017) · Applied Materials Today · doi:10.1016/j.apmt.2017.10.002 · Cited by 27 · see citing works
Equine lamellar energy metabolism studied using tissue microdialysis
Medina‐Torres, C. E., Pollitt, C. C., Underwood, C., Castro‐Olivera, E. M., Collins, S. N., Allavena, R., Richardson, D. W., & Eps, A. W. V. (2014) · The Veterinary Journal · doi:10.1016/j.tvjl.2014.05.030 · Cited by 19 · see citing works
Nitric oxide-releasing polyurethanes
Pant, J., Goudie, M. J., Brisbois, E. J., & Handa, H. (2016) · Elsevier eBooks · doi:10.1016/b978-0-08-100614-6.00014-7 · Cited by 18 · see citing works
Combination of Nitric Oxide Release and Surface Texture for Mitigating the Foreign Body Response
Malone‐Povolny, M. J., Bradshaw, T. M., Merricks, E. P., Long, C. T., Nichols, T. C., & Schoenfisch, M. H. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.1c00022 · Cited by 16 · see citing works
Self-citationNitric oxide-releasing silica nanoparticles with varied surface hydrophobicity
Carpenter, A. W., Johnson, J. A., & Schoenfisch, M. H. (2014) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2014.03.094 · Cited by 15 · see citing works
Self-citationStokes, S. M., Bertin, F., Stefanovski, D., Belknap, J. K., Medina‐Torres, C. E., Pollitt, C. C., & Eps, A. W. V. (2019) · Equine Veterinary Journal · doi:10.1111/evj.13224 · Cited by 14 · see citing works
Microdialysis sampling techniques applied to studies of the foreign body reaction
Sides, C. R., & Stenken, J. A. (2013) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2013.11.002 · Cited by 13 · see citing works
Mechanisms of Foreign Body Response Mitigation by Nitric Oxide Release
Taylor, J. B., Malone‐Povolny, M. J., Merricks, E. P., Wimsey, L. E., Soliman, D., Nichols, T. C., Wallet, S. M., Maile, R., & Schoenfisch, M. H. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms231911635 · Cited by 8 · see citing works
Self-citationContinuous glucose microsensor with a nanoscale conducting matrix and redox mediator
Pesantez, D., Castracane, J., & Gadre, A. P. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.01.043 · Cited by 6 · see citing works
Microdialysis Probe Requirements
Córcoles, E. P., & Boutelle, M. G. (2013) · SpringerBriefs in applied sciences and technology · doi:10.1007/978-3-319-00360-3_8
Dual Foreign Body Response Mitigation Strategies for Implantable Glucose Sensors
Bradshaw, T. M., Nogler, M. E., Warchol, M. F., Willis, M. L., Walker, A. R., Maile, R., Wallet, S. M., Merricks, E. P., Nichols, T. C., & Schoenfisch, M. H. (2025) · Advanced Sensor Research · doi:10.1002/adsr.202500031
Self-citationEvaluation of a subcutaneous continuous glucose monitoring system in critically ill neonatal foals
Payette, F., Leduc, L., Stefanovski, D., Abraham, M., & Eps, A. W. V. (2026) · Journal of Veterinary Internal Medicine · doi:10.1093/jvimsj/aalaf059
- Authors
- Nichols, S. P., Le, N. N., Klitzman, B., & Schoenfisch, M. H.
- Affiliations
- University of North Carolina at Chapel Hill (US)
- Duke University (US)
- Corresponding author
- Schoenfisch, Mark H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-01-14
- Volume
- 83
- Issue
- 4
- Pages
- 1180-1184
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- PMC
- PMC3039076
- OpenAlex
- W2065992574
- Cited by
- 26
- References
- 43
- Citations by year
- 2026: 1 · 2025: 1 · 2022: 1 · 2021: 1 · 2019: 2 · 2017: 2 · 2016: 3 · 2015: 3 · 2014: 4 · 2013: 4 · 2012: 2
- FWCI
- 2.68
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health
- National Institute of Biomedical Imaging and Bioengineering (EB 000708, R01EB000708)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Keywords
- nitric oxide release, glucose recovery, subcutaneous glucose sensor, microdialysis probe, foreign body reaction, glucose diffusion, capsule thickness, inflammation, implant surface modification
- MeSH terms
- Animals, Cell Count, Glucose, Inflammation, Male, Nitric Oxide, Microdialysis, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review