The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Electrostatic Axially Harmonic Orbital Trapping: A High-Performance Technique of Mass Analysis
Abstract
This work describes a new type of mass analyzer which employs trapping in an electrostatic field. The potential distribution of the field can be represented as a combination of quadrupole and logarithmic potentials. In the absence of any magnetic or rf fields, ion stability is achieved only due to ions orbiting around an axial electrode. Orbiting ions also perform harmonic oscillations along the electrode with frequency proportional to (m/z)-1/2. These oscillations are detected using image current detection and are transformed into mass spectra using fast FT, similarly to FTICR. Practical aspects of the trap design are presented. High-mass resolution up to 150,000 for ions produced by laser ablation has been demonstrated, along with high-energy acceptance and wide mass range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Int. J. Mass Spectrom. Ion Processes
(1990) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(90)80022-u · Cited by 1,003
Quadrupole storage mass spectrometry
March, R. E., Hughes, R. J., & Roberts, A. D. (1991) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)82582-9 · Cited by 535
Kingdon, K. H. (1923) · Physical Review · doi:10.1103/physrev.21.408 · Cited by 390
Benner, W. H. (1997) · Analytical Chemistry · doi:10.1021/ac970163e · Cited by 203
Schriemer, D. C., & Li, L. (1997) · Analytical Chemistry · doi:10.1021/ac9702610 · Cited by 150
Routine Part-per-Million Mass Accuracy for High- Mass Ions: Space-Charge Effects in MALDI FT-ICR
Easterling, M. L., Mize, T. H., & Amster, I. J. (1998) · Analytical Chemistry · doi:10.1021/ac980690d · Cited by 150
Storage of ions from laser-produced plasmas
Knight, R. D. (1981) · Applied Physics Letters · doi:10.1063/1.92315 · Cited by 101
Energy-isochronous time-of-flight mass analyzers
Wöllnik, H. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(93)03888-s · Cited by 38
A two-electrode ion trap for Fourier transform ion cyclotron resonance mass spectrometry
Marto, J. A., Marshall, A. G., & Schweikhard, L. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)85008-9 · Cited by 16
Cited by
Olsen, J. V., de Godoy, L. M. F., Li, G., Macek, B., Mortensen, P., Pesch, R., Makarov, A., Lange, O., Horning, S., & Mann, M. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500030-mcp200 · Cited by 1,510
Self-citationProtein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
Functional and quantitative proteomics using SILAC
Mann, M. (2006) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2067 · Cited by 931
Michalski, A., Damoc, E., Hauschild, J.-P., Lange, O., Wieghaus, A., Makarov, A., Nagaraj, N., Cox, J., Mann, M., & Horning, S. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.011015 · Cited by 832
Self-citationDefinitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
Zubarev, R. A., & Makarov, A. (2013) · Analytical Chemistry · doi:10.1021/ac4001223 · Cited by 658
Self-citationHigh-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Lu, W., Clasquin, M. F., Melamud, E., Amador-Noguez, D., Caudy, A. A., & Rabinowitz, J. D. (2010) · Analytical Chemistry · doi:10.1021/ac902837x · Cited by 502
Top Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507
“A new type of Fourier transform mass spectrometer was described in 2000, the Orbitrap mass analyzer [101].”
MethodMass Spectrometry Strategies in Metabolomics
Lei, Z., Huhman, D. V., & Sumner, L. W. (2011) · Journal of Biological Chemistry · doi:10.1074/jbc.r111.238691 · Cited by 481
Metabolite Measurement: Pitfalls to Avoid and Practices to Follow
Lu, W., Su, X., Klein, M. S., Lewis, I. A., Fiehn, O., & Rabinowitz, J. D. (2017) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-061516-044952 · Cited by 462
Precision proteomics: The case for high resolution and high mass accuracy
Mann, M., & Kelleher, N. L. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0800788105 · Cited by 450
Dynamic range of mass accuracy in LTQ orbitrap hybrid mass spectrometer
Makarov, A., Denisov, E., Lange, O., & Horning, S. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.03.006 · Cited by 431
Self-citationHigh-sensitivity Orbitrap mass analysis of intact macromolecular assemblies
Rose, R. J., Damoc, E., Denisov, E., Makarov, A., & Heck, A. J. R. (2012) · Nature Methods · doi:10.1038/nmeth.2208 · Cited by 392
Self-citationMass spectrometry‐based plant metabolomics: Metabolite responses to abiotic stress
Jorge, T. F., Rodrigues, J. A., Caldana, C., Schmidt, R., van Dongen, J. T., Thomas‐Oates, J., & António, C. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21449 · Cited by 376
Michalski, A., Damoc, E., Lange, O., Denisov, E., Nolting, D., Müller, M., Viner, R., Schwartz, J., Remes, P., Belford, M., et al. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.013698 · Cited by 373
Self-citationMass spectrometry imaging with high resolution in mass and space
Römpp, A., & Spengler, B. (2013) · Histochemistry and Cell Biology · doi:10.1007/s00418-013-1097-6 · Cited by 358
Recent developments in liquid chromatography–mass spectrometry and related techniques
Holčapek, M., Jirásko, R., & Lísa, M. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.08.072 · Cited by 330
Mass-spectrometry-based proteomics: from single cells to clinical applications
Guo, T., Steen, J. A., & Mann, M. (2025) · Nature · doi:10.1038/s41586-025-08584-0 · Cited by 320
Interfacing the Orbitrap Mass Analyzer to an Electrospray Ion Source
Hardman, M., & Makarov, A. A. (2003) · Analytical Chemistry · doi:10.1021/ac0258047 · Cited by 314
Self-citationHigh-sensitivity Analytical Approaches for the Structural Characterization of Glycoproteins
Alley, W. R., Mann, B. F., & Novotny, M. V. (2013) · Chemical Reviews · doi:10.1021/cr3003714 · Cited by 310
Orbitrap Mass Analyzer – Overview and Applications in Proteomics
Scigelova, M., & Makarov, A. (2006) · PROTEOMICS · doi:10.1002/pmic.200600528 · Cited by 288
Self-citationHigh Resolution Mass Spectrometry
Xian, F., Hendrickson, C. L., & Marshall, A. G. (2012) · Analytical Chemistry · doi:10.1021/ac203191t · Cited by 281
Performance evaluation of a high-field Orbitrap mass analyzer
Makarov, A., Denisov, E., & Lange, O. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.01.005 · Cited by 188
Self-citationSerine Octamers: Cluster Formation, Reactions, and Implications for Biomolecule Homochirality
Nanita, S. C., & Cooks, R. G. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200501328 · Cited by 184
Proteins in Art, Archaeology, and Paleontology: From Detection to Identification
Dallongeville, S., Garnier, N., Rolando, C., & Tokarski, C. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00037 · Cited by 172
Snijder, J., van de Waterbeemd, M., Damoc, E., Denisov, E., Grinfeld, D., Bennett, A., Agbandje-McKenna, M., Makarov, A., & Heck, A. J. R. (2014) · Journal of the American Chemical Society · doi:10.1021/ja502616y · Cited by 168
Self-citationTop-down Proteomics: Technology Advancements and Applications to Heart Diseases
Cai, W., Tucholski, T. M., Gregorich, Z. R., & Ge, Y. (2016) · Expert Review of Proteomics · doi:10.1080/14789450.2016.1209414 · Cited by 99
Measurement of Individual Ions Sharply Increases the Resolution of Orbitrap Mass Spectra of Proteins
Kafader, J. O., Melani, R. D., Senko, M. W., Makarov, A. A., Kelleher, N. L., & Compton, P. D. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04519 · Cited by 87
Self-citation40 years of Fourier transform ion cyclotron resonance mass spectrometry
Marshall, A. G., & Chen, T. (2015) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2014.06.034 · Cited by 70
Extending the Isotopically Resolved Mass Range of Orbitrap Mass Spectrometers
Shaw, J. B., & Brodbelt, J. S. (2013) · Analytical Chemistry · doi:10.1021/ac401634b · Cited by 28
Metadata
- Authors
- Makarov, A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-02-10
- Volume
- 72
- Issue
- 6
- Pages
- 1156-1162
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1982468602
- Cited by
- 1,009
- References
- 9
- FWCI
- 1.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.