The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Fluorescent Probes for Sensing and Imaging within Specific Cellular Organelles
Abstract
Fluorescent probes have become powerful tools in biosensing and bioimaging because of their high sensitivity, specificity, fast response, and technical simplicity. In the last decades, researchers have made remarkable progress in developing fluorescent probes that respond to changes in microenvironments (e.g., pH, viscosity, and polarity) or quantities of biomolecules of interest (e.g., ions, reactive oxygen species, and enzymes). All of these analytes are specialized to carry out vital functions and are linked to serious disorders in distinct subcellular organelles. Each of these organelles plays a specific and indispensable role in cellular processes. For example, the nucleus regulates gene expression, mitochondria are responsible for aerobic metabolism, and lysosomes digest macromolecules for cell recycling. A certain organelle requires specific biological species and the appropriate microenvironment to perform its cellular functions, while breakdown of the homeostasis of biomolecules or microenvironmental mutations leads to organelle malfunctions, which further cause disorders or diseases. Fluorescent probes that can be targeted to both specific organelles and biochemicals/microenvironmental factors are capable of reporting localized bioinformation and are potentially useful for gaining insight into the contributions of analytes to both healthy and diseased states. In this Account, we review our recent work on the development of fluorescent probes for sensing and imaging within specific organelles. We present an overview of the design, photophysical properties, and biological applications of the probes, which can localize to mitochondria, lysosomes, the nucleus, the Golgi apparatus, and the endoplasmic reticulum. Although a diversity of organelle-specific fluorescent stains have been commercially available, our efforts place an emphasis on improvements in terms of low cytotoxicity, high photostability, near-infrared (NIR) emission, two-photon excitation, and long fluorescence lifetimes, which are crucial for long-time tracking of biological processes, tissue and body imaging with deep penetration and low autofluorescence, and time-resolved fluorescence imaging. Research on fluorescent probes with both analyte responsiveness and organelle targetability is a new and emerging area that has attracted increasing attention over the past few years. We have extended the diversity by developing organelle-specific responsive probes capable of detecting changes in biomolecular levels (reactive oxygen species, fluoride ion, hydrogen sulfide, zinc cation, thiol-containing amino acids, and cyclooxygenase-2) and the microenvironment (viscosity, polarity, and pH). Future research should give more considerations of the "low-concern" organelles, such as the Golgi apparatus, the endoplasmic reticulum, and ribosomes. In addition, given the tiny sizes of subcellular organelles (20-1000 nm), we anticipate that clearer visulization of the cellular events within specific organelles will rely on super-resolution optical microscopy with nanoscopic-scale resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-46312-4 · Cited by 19,339
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
ROS as signalling molecules: Mechanisms that generate specificity in ROS homeostasis
D'Autréaux, B., & Toledano, M. B. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2256 · Cited by 3,642
Mitochondrial diseases in man and mouse
Wallace, D. C. (1999) · Science · doi:10.1126/science.283.5407.1482 · Cited by 3,060
Lagona, J., Mukhopadhyay, P., Chakrabarti, S., & Isaacs, L. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200460675 · Cited by 2,444
Luby-Phelps, K. (1999) · International Review of Cytology · doi:10.1016/s0074-7696(08)60527-6 · Cited by 1,149
A Role for Lipid Shells in Targeting Proteins to Caveolae, Rafts, and Other Lipid Domains
Anderson, R. G. W., & Jacobson, K. (2002) · Science · doi:10.1126/science.1068886 · Cited by 1,125
Macro-/micro-environment-sensitive chemosensing and biological imaging
Yang, Z., Cao, J., He, Y., Yang, J. H., Kim, T., Peng, X., & Kim, J. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00051j · Cited by 875
Self-citationNIR dyes for bioimaging applications
Escobedo, J. O., Rusin, O., Lim, S., & Strongin, R. M. (2010) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2009.10.022 · Cited by 762
A Photostable AIE Luminogen for Specific Mitochondrial Imaging and Tracking
Leung, C. W. T., Hong, Y., Chen, S., Zhao, E., Lam, J. W. Y., & Tang, B. Z. (2013) · Journal of the American Chemical Society · doi:10.1021/ja310324q · Cited by 729
Hydrogen Sulfide Increases Glutathione Production and Suppresses Oxidative Stress in Mitochondria
Kimura, Y., Goto, Y.-I., & Kimura, H. (2010) · Antioxidants & Redox Signaling · doi:10.1089/ars.2008.2282 · Cited by 685
A Targetable Fluorescent Probe for Imaging Hydrogen Peroxide in the Mitochondria of Living Cells
Dickinson, B. C., & Chang, C. J. (2008) · Journal of the American Chemical Society · doi:10.1021/ja802355u · Cited by 642
Fluorescent probes for sensing and imaging
Ueno, T., & Nagano, T. (2011) · Nature Methods · doi:10.1038/nmeth.1663 · Cited by 633
Wiederschain, G. Y. (2011) · Biochemistry (Moscow) · doi:10.1134/s0006297911110101 · Cited by 619
A ruthenium(II) polypyridyl complex for direct imaging of DNA structure in living cells
Gill, M. R., Garcı́a-Lara, J., Foster, S. J., Smythe, C., Battaglia, G., & Thomas, J. A. (2009) · Nature Chemistry · doi:10.1038/nchem.406 · Cited by 487
A Self-Calibrating Bipartite Viscosity Sensor for Mitochondria
Yang, Z., He, Y., Lee, J.-H., Park, N., Suh, M., Chae, W.-S., Cao, J., Peng, X., Jung, H., Kang, C., et al. (2013) · Journal of the American Chemical Society · doi:10.1021/ja403851p · Cited by 468
Self-citationRapid Cancer Detection by Topically Spraying a γ-Glutamyltranspeptidase–Activated Fluorescent Probe
Urano, Y., Sakabe, M., Kosaka, N., Ogawa, M., Mitsunaga, M., Asanuma, D., Kamiya, M., Young, M. R., Nagano, T., Choyke, P. L., et al. (2011) · Science Translational Medicine · doi:10.1126/scitranslmed.3002823 · Cited by 466
Activatable Rotor for Quantifying Lysosomal Viscosity in Living Cells
Wang, L., Xiao, Y., Tian, W., & Deng, L. (2013) · Journal of the American Chemical Society · doi:10.1021/ja311688g · Cited by 464
Targeting Mitochondria with Organelle‐Specific Compounds: Strategies and Applications
Yousif, L. F., Stewart, K. M., & Kelley, S. O. (2009) · ChemBioChem · doi:10.1002/cbic.200900185 · Cited by 330
Xiong, X., Song, F., Wang, J., Zhang, Y., Xue, Y., Sun, L., Jiang, N., Gao, P., Tian, L., & Peng, X. (2014) · Journal of the American Chemical Society · doi:10.1021/ja502292p · Cited by 326
Self-citationAn Off–On COX-2-Specific Fluorescent Probe: Targeting the Golgi Apparatus of Cancer Cells
Zhang, H., Fan, J., Wang, J., Zhang, S., Dou, B., & Peng, X. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4056905 · Cited by 324
Self-citationMitochondrial-targeted fluorescent probes for reactive oxygen species
Dickinson, B. C., Srikun, D., & Chang, C. J. (2010) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2009.10.014 · Cited by 314
Dodani, S. C., Leary, S. C., Cobine, P. A., Winge, D. R., & Chang, C. J. (2011) · Journal of the American Chemical Society · doi:10.1021/ja2004158 · Cited by 298
Polarity-Sensitive Coumarins Tailored to Live Cell Imaging
Signore, G., Nifosì, R., Albertazzi, L., Storti, B., & Bizzarri, R. (2010) · Journal of the American Chemical Society · doi:10.1021/ja9050444 · Cited by 264
Mitochondria in the diabetic heart
Bugger, H., & Abel, E. D. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq239 · Cited by 260
Toxicology and Drug Delivery by Cucurbit[n]uril Type Molecular Containers
Hettiarachchi, G., Nguyen, D., Wu, J., Lucas, D., Ma, D., Isaacs, L., & Briken, V. (2010) · PLoS ONE · doi:10.1371/journal.pone.0010514 · Cited by 254
A Mitochondrial-Targeted Two-Photon Probe for Zinc Ion
Masanta, G., Lim, C. S., Kim, H. J., Han, J. H., Kim, H. M., & Cho, B. R. (2011) · Journal of the American Chemical Society · doi:10.1021/ja200444t · Cited by 243
Organelle-Specific Zinc Detection Using Zinpyr-Labeled Fusion Proteins in Live Cells
Tomat, E., Nolan, E. M., Jaworski, J., & Lippard, S. J. (2008) · Journal of the American Chemical Society · doi:10.1021/ja806634e · Cited by 202
A highly specific BODIPY-based probe localized in mitochondria for HClO imaging
Cheng, G., Fan, J., Sun, W., Sui, K., Jin, X., Wang, J., & Peng, X. (2013) · The Analyst · doi:10.1039/c3an01152f · Cited by 174
Self-citationUddin, M. J., Crews, B. C., Blobaum, A. L., Kingsley, P. J., Gorden, D. L., McIntyre, J. O., Matrisian, L. M., Subbaramaiah, K., Dannenberg, A. J., Piston, D. W., et al. (2010) · Cancer Research · doi:10.1158/0008-5472.can-09-2664 · Cited by 172
Hwang, J. J., Lee, S.-J., Kim, T.-Y., Cho, J.-H., & Koh, J. (2008) · Journal of Neuroscience · doi:10.1523/jneurosci.0199-08.2008 · Cited by 159
Silvers, W. C., Prasai, B., Burk, D. H., Brown, M. L., & McCarley, R. L. (2012) · Journal of the American Chemical Society · doi:10.1021/ja309346f · Cited by 150
ER–Golgi network—A future target for anti-cancer therapy
Włodkowic, D., Skommer, J., McGuinness, D., Hillier, C., & Darżynkiewicz, Z. (2009) · Leukemia Research · doi:10.1016/j.leukres.2009.05.025 · Cited by 136
Two‐Photon Fluorescent Probes for Acidic Vesicles in Live Cells and Tissue
Kim, H. M., An, M. J., Hong, J. H., Jeong, B. H., Kwon, O., Hyon, J., Hong, S., Lee, K. J., & Cho, B. R. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200704586 · Cited by 128
A fluorescent probe for H 2 S in vivo with fast response and high sensitivity
Li, H. D., Yao, Q., Fan, J. L., Jiang, N., Wang, J., Xia, J., & Peng, X. (2015) · Chemical Communications · doi:10.1039/c5cc06612c · Cited by 122
Self-citationZhang, S., Wu, T., Fan, J., Li, Z., Jiang, N., Wang, J., Dou, B., Sun, S., Song, F., & Peng, X. (2012) · Organic & Biomolecular Chemistry · doi:10.1039/c2ob26911b · Cited by 122
Self-citationPositively Charged Ceramide Is a Potent Inducer of Mitochondrial Permeabilization
Novgorodov, S. A., Szulc, Z. M., Luberto, C., Jones, J. A., Bielawski, J., Bielawska, A. E., Hannun, Y. A., & Obeid, L. M. (2005) · Journal of Biological Chemistry · doi:10.1074/jbc.m411707200 · Cited by 113
Liu, F., Wu, T., Cao, J., Zhang, H., Hu, M., Sun, S., Song, F., Fan, J., Wang, J., & Peng, X. (2012) · The Analyst · doi:10.1039/c2an36030f · Cited by 109
Self-citationA near-infrared dye based on BODIPY for tracking morphology changes in mitochondria
Jiang, N., Fan, J., Liu, T., Cao, J., Qiao, B., Wang, J., Gao, P., & Peng, X. (2013) · Chemical Communications · doi:10.1039/c3cc46143b · Cited by 89
Self-citationDual mode monitoring probe for mitochondrial viscosity in single cell
Jiang, N., Fan, J., Zhang, S., Wu, T., Wang, J., Gao, P., Qu, J., Zhou, F., & Peng, X. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.09.062 · Cited by 84
Self-citationA Two-Photon Fluorescent Probe for Lysosomal Thiols in Live Cells and Tissues
Fan, J., Han, Z., Kang, Y., & Peng, X. (2016) · Scientific Reports · doi:10.1038/srep19562 · Cited by 84
Self-citationUddin, M. J., Crews, B. C., Ghebreselasie, K., & Marnett, L. J. (2013) · Bioconjugate Chemistry · doi:10.1021/bc300693w · Cited by 76
A Nile blue based infrared fluorescent probe: imaging tumors that over-express cyclooxygenase-2
Wang, B., Fan, J., Wang, X., Zhu, H., Wang, J., Mu, H., & Peng, X. (2014) · Chemical Communications · doi:10.1039/c4cc08915d · Cited by 76
Self-citationLi, Z., Sun, S., Yang, Z., Zhang, S., Zhang, H., Hu, M., Cao, J., Wang, J., Liu, F., Song, F., et al. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.05.020 · Cited by 76
Self-citationBalce, D. R., Allan, E. R. O., McKenna, N. T., & Yates, R. M. (2014) · Journal of Biological Chemistry · doi:10.1074/jbc.m114.584391 · Cited by 72
Zhang, S., Fan, J., Li, Z., et al. (2014) · Journal of Materials Chemistry B · doi:10.1039/c3tb21844a · Cited by 72
Self-citationFan, J., Dong, H., Hu, M., Wang, J., Zhang, H., Zhu, H., Sun, W. C., & Peng, X. (2013) · Chemical Communications · doi:10.1039/c3cc48043g · Cited by 57
Self-citationJiang, N., Fan, J., Xu, F., Peng, X., Mu, H., Wang, J., & Xiong, X. (2015) · Angewandte Chemie · doi:10.1002/ange.201410645 · Cited by 55
Self-citationTwo-Photon Lysotrackers for in Vivo Imaging
Son, J. H., Lim, C. S., Han, J. H., Danish, I. A., Kim, H. M., & Cho, B. R. (2011) · The Journal of Organic Chemistry · doi:10.1021/jo201504h · Cited by 44
Basha, P. M., & Saumya, S. M. (2013) · Cellular and Molecular Neurobiology · doi:10.1007/s10571-013-9912-0 · Cited by 41
Cited by
Klymchenko, A. S. (2017) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00517 · Cited by 1,220
Ratiometric optical nanoprobes enable accurate molecular detection and imaging
Huang, X., Song, J., Yung, B. C., Huang, X., Xiong, Y., & Chen, X. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00612h · Cited by 820
Fluorescent probes for organelle-targeted bioactive species imaging
Gao, P., Pan, W., Li, N., & Tang, B. (2019) · Chemical Science · doi:10.1039/c9sc01652j · Cited by 599
Yin, J., Huang, L., Wu, L., Li, J., James, T. D., & Lin, W. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00645b · Cited by 549
Cheng, D., Pan, Y., Wang, L., Zeng, Z., Yuan, L., Zhang, X., & Chang, Y.-T. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.6b10508 · Cited by 500
Metadata
- Authors
- Zhu, H., Fan, J., Du, J., & Peng, X.
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-09-23
- Volume
- 49
- Issue
- 10
- Pages
- 2115-2126
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W2522989562
- Cited by
- 984
- References
- 50
- FWCI
- 41.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.