Cited by 100Analytical Chemistry and SensorsAdvanced Sensor and Energy Harvesting MaterialsElectrochemical sensors and biosensors

Wearable Potentiometric Chloride Sweat Sensor: The Critical Role of the Salt Bridge

Choi, Dong-Hoon, Kim, Jin Seob, Cutting, Garry R., Searson, Peter C.·2016·Analytical Chemistry

Abstract

The components of sweat provide an array of potential biomarkers for health and disease. Sweat chloride is of interest as a biomarker for cystic fibrosis, electrolyte metabolism disorders, electrolyte balance, and electrolyte loss during exercise. Developing wearable sensors for biomarkers in sweat is a major technological challenge. Potentiometric sensors provide a relatively simple technology for on-body sweat chloride measurement, however, equilibration between reference and test solutions has limited the time over which accurate measurements can be made. Here, we report on a wearable potentiometric chloride sweat sensor. We performed parametric studies to show how the salt bridge geometry determines equilibration between the reference and test solutions. From these results, we show a sweat chloride sensor can be designed to provide accurate measurements over extended times. We then performed on-body tests on healthy subjects while exercising to establish the feasibility of using this technology as a wearable device.

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.6b03391

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Researchers successfully developed a wrist-based potentiometric wearable device capable of detecting Cl− concentrations over time from sweat for cystic fibrosis monitoring.

    “While there remains an unmet medical need to measure Cl− levels in real-time for sports, researchers successfully developed a wrist-based potentiometric wearable device capable of detecting Cl− concentrations over time from sweat for cystic fibrosis monitoring.36”
  • There remains an unmet medical need to measure Cl− levels in real-time for sports.

    “While there remains an unmet medical need to measure Cl− levels in real-time for sports, researchers successfully developed a wrist-based potentiometric wearable device capable of detecting Cl− concentrations over time from sweat for cystic fibrosis monitoring.36”
  • The wrist-based Cl− sensor was placed on human subjects by a wristband or adhesive tape and tested during exercise to demonstrate the feasibility of this technology as a wearable device.

    “The sensor was placed on human subjects by a wristband or adhesive tape and tested during exercise to demonstrate the feasibility of this technology as a wearable device.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Choi, D.-H., Kim, J. S., Cutting, G. R., & Searson, P. C.
Affiliations
Johns Hopkins University (US)
Corresponding author
Searson, Peter C.
Venue
Analytical Chemistry
Published
2016-11-29
Volume
88
Issue
24
Pages
12241-12247
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2554504443
Cited by
100
References
21
Citations by year
2026: 7 · 2025: 8 · 2024: 16 · 2023: 10 · 2022: 15 · 2021: 5 · 2020: 14 · 2019: 12 · 2018: 9 · 2017: 4
FWCI
6.75
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
Johns Hopkins University
Topics
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
Keywords
sweat chloride, potentiometric sensors, wearable sensors, salt bridges, reference electrode, electrolyte balance, physical activity
MeSH terms
Wearable Electronic Devices, Adult, Chlorides, Cystic Fibrosis, Electrolytes, Equipment Design, Female, Humans, Male, Potentiometry, Sweat, Sweating, Exercise, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review