Single-Shot Top-Down Proteomics with Capillary Zone Electrophoresis-Electrospray Ionization-Tandem Mass Spectrometry for Identification of Nearly 600 Escherichia coli Proteoforms

Open access
Lubeckyj, Rachele A., McCool, Elijah N., Shen, Xiaojing, Kou, Qiang, Liu, Xiaowen, Sun, Liangliang·2017·Analytical Chemistry

Abstract

Capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry (CZE-ESI-MS/MS) has been recognized as an invaluable platform for top-down proteomics. However, the scale of top-down proteomics using CZE-MS/MS is still limited due to the low loading capacity and narrow separation window of CZE. In this work, for the first time we systematically evaluated the dynamic pH junction method for focusing of intact proteins during CZE-MS. The optimized dynamic pH junction-based CZE-MS/MS approached a 1 μL loading capacity, 90 min separation window, and high peak capacity (∼280) for characterization of an Escherichia coli proteome. The results represent the largest loading capacity and the highest peak capacity of CZE for top-down characterization of complex proteomes. Single-shot CZE-MS/MS identified about 2800 proteoform-spectrum matches, nearly 600 proteoforms, and 200 proteins from the Escherichia coli proteome with spectrum-level false discovery rate (FDR) less than 1%. The number of identified proteoforms in this work is over three times higher than that in previous single-shot CZE-MS/MS studies. Truncations, N-terminal methionine excision, signal peptide removal, and some post-translational modifications including oxidation and acetylation were detected.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.7b02532

Cites

53 of 53 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The Sun group optimized dynamic pH junction CZE using 10% acetic acid as background electrolyte to load ~1 μL and demonstrated single-shot CZE-MS identification of ~600 proteoforms from E. coli lysate.

    “To address these major issues, the Sun group optimized the dynamic pH junction CZE method, using 10% acetic acid as the background electrolyte, to load ~1 μL of sample and they demonstrated the use of single-shot CZE-MS analysis to identify ~600 proteoforms from an Escherichia coli lysate [74].”
  • A CZE separation for top-down proteome analysis of Escherichia coli resulted in a high peak capacity of about 280.

    “Figure 4 shows a CZE separation for top-down proteome analysis of Escherichia coli that resulted in high peak capacity (~ 280, calculated using the average peak width at 50% peak height for the Escherichia coli proteome sample)69.”
  • Acetic acid increased protein migration time, which may be attributed to lower pH causing increased hydrodynamic protein radii, more protein unfolding, and reduced electroosmotic flow.

    “The use of acetic acid also increased the migration time of the proteins, which might be attributed to the lower pH of acetic acid that resulted in an increase in hydrodynamics in protein radii, exacerbation of protein unfolding, and reduction of EOF.”
  • A BGE of 0.1% formic acid at pH 2.8 gave peak intensities equivalent to acetic acid BGEs.

    “A BGE composed of 0.1% formic acid (pH 2.8) resulted in peak intensities equivalent to the acetic acid BGEs, as illustrated in the Figure 5.”
  • Lubeckyj and co-workers developed a strategy for large-scale top-down analysis using Escherichia coli lysate.

    “A strategy for large scale top-down analysis using lysate from Escherichia coli was developed by Lubeckyj and co-workers69.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Lubeckyj, R. A., McCool, E. N., Shen, X., Kou, Q., Liu, X., & Sun, L.
Affiliations
  • Michigan State University (US)
  • Indiana University Indianapolis (US)
Corresponding author
Sun, Liangliang
Venue
Analytical Chemistry
Published
2017-11-07
Volume
89
Issue
22
Pages
12059-12067
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2766426851
Cited by
96
References
53
Citations by year
2026: 7 · 2025: 11 · 2024: 5 · 2023: 7 · 2022: 8 · 2021: 10 · 2020: 11 · 2019: 20 · 2018: 16 · 2016: 1
FWCI
6.34
Type
journal article
Language
en
Open access
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
  • IUScholarWorks (Indiana University) (submittedVersion)
Funders
  • Michigan State University
  • National Institute of General Medical Sciences (R01GM118470)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
Keywords
top-down proteomics, capillary zone electrophoresis, dynamic pH junction, Escherichia coli proteome, proteoforms, protein truncation, N-terminal methionine excision, signal peptide removal, post-translational modification, oxidation, acetylation, loading capacity, peak capacity
MeSH terms
Escherichia coli, Hydrogen-Ion Concentration, Electrophoresis, Capillary, Proteome, Spectrometry, Mass, Electrospray Ionization, Escherichia coli Proteins, Proteomics, Tandem Mass Spectrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review