The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Hypoxia and H2O2 Dual-Sensitive Vesicles for Enhanced Glucose-Responsive Insulin Delivery
Abstract
A glucose-responsive closed-loop insulin delivery system mimicking pancreas activity without long-term side effect has the potential to improve diabetic patients’ health and quality of life. Here, we developed a novel glucose-responsive insulin delivery device using a painless microneedle-array patch containing insulin-loaded vesicles. Formed by self-assembly of hypoxia and H 2 O 2 dual-sensitive diblock copolymer, the glucose-responsive polymersome-based vesicles ( d -GRPs) can disassociate and subsequently release insulin triggered by H 2 O 2 and hypoxia generated during glucose oxidation catalyzed by glucose specific enzyme. Moreover, the d -GRPs were able to eliminate the excess H 2 O 2, which may lead to free radical-induced damage to skin tissue during the long-term usage and reduce the activity of GOx. In vivo experiments indicated that this smart insulin patch could efficiently regulate the blood glucose in the chemically induced type 1 diabetic mice for 10 h.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A SPECTROPHOTOMETRIC METHOD FOR MEASURING THE BREAKDOWN OF HYDROGEN PEROXIDE BY CATALASE
Beers, R. F., & Sizer, I. W. (1952) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)50881-x · Cited by 6,761
Prausnitz, M. R., & Langer, R. (2008) · Nature Biotechnology · doi:10.1038/nbt.1504 · Cited by 3,517
Ohkubo, Y., Kishikawa, H., Araki, E., Miyata, T., Isami, S., Motoyoshi, S., Kojima, Y., Furuyoshi, N., & Shichiri, M. (1995) · Diabetes Research and Clinical Practice · doi:10.1016/0168-8227(95)01064-k · Cited by 3,079
Microneedles for transdermal drug delivery
Prausnitz, M. R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.10.023 · Cited by 1,521
Lu, Y., Aimetti, A. A., Langer, R., & Gu, Z. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.75 · Cited by 1,421
Self-citationOxidation-responsive polymeric vesicles
Napoli, A., Valentini, M., Tirelli, N., Müller, M., & Hubbell, J. A. (2004) · Nature Materials · doi:10.1038/nmat1081 · Cited by 889
Yu, J., Zhang, Y., Ye, Y., DiSanto, R., Sun, W., Ranson, D., Ligler, F. S., Buse, J. B., & Gu, Z. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1505405112 · Cited by 848
Self-citationManaging diabetes with nanomedicine: challenges and opportunities
Veiseh, O., Tang, B. C., Whitehead, K. A., Anderson, D. G., & Langer, R. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4477 · Cited by 613
Kataoka, K., Miyazaki, H., Bunya, M., Okano, T., & Sakurai, Y. (1998) · Journal of the American Chemical Society · doi:10.1021/ja982975d · Cited by 590
Redox-responsive polymers for drug delivery: from molecular design to applications
Huo, M., Yuan, J., Tao, L., & Wei, Y. (2014) · Polym. Chem. · doi:10.1039/c3py01192e · Cited by 561
Cited by
Recent progress in drug delivery
Li, C., Wang, J., Wang, Y., Gao, H., Wei, G., Huang, Y., Yu, H., Gan, Y., Wang, Y., Mei, L., et al. (2019) · Acta Pharmaceutica Sinica B · doi:10.1016/j.apsb.2019.08.003 · Cited by 818
Catalytic chemistry of glucose oxidase in cancer diagnosis and treatment
Fu, L.-H., Qi, C., Lin, J., & Huang, P. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00891k · Cited by 783
Glucose-responsive insulin patch for the regulation of blood glucose in mice and minipigs
Yu, J., Wang, J., Zhang, Y., Chen, G., Mao, W., Ye, Y., Kahkoska, A. R., Buse, J. B., Langer, R., & Gu, Z. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0508-y · Cited by 604
Self-citationWang, S., Zheng, H., Zhou, L., Cheng, F., Liu, Z., Zhang, H., Wang, L., & Zhang, Q. (2020) · Nano Letters · doi:10.1021/acs.nanolett.0c01371 · Cited by 573
Chang, H., Zheng, M., Yu, X., Than, A., Seeni, R. Z., Kang, R., Tian, J., Khanh, D. P., Liu, L., Chen, P., et al. (2017) · Advanced Materials · doi:10.1002/adma.201702243 · Cited by 462
Stimuli-Responsive Polymersomes for Biomedical Applications
Hu, X., Zhang, Y., Xie, Z., Jing, X., Bellotti, A., & Gu, Z. (2017) · Biomacromolecules · doi:10.1021/acs.biomac.6b01704 · Cited by 394
Self-citationDevice-assisted transdermal drug delivery
Lee, H., Song, C., Baik, S., Kim, D., Hyeon, T., & Kim, D.-H. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2017.08.009 · Cited by 343
Advances in transdermal insulin delivery
Zhang, Y., Yu, J., Kahkoska, A. R., Wang, J., Buse, J. B., & Gu, Z. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.12.006 · Cited by 325
Self-citationPolymeric microneedles for transdermal protein delivery
Ye, Y., Yu, J., Wen, D., Kahkoska, A. R., & Gu, Z. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.01.015 · Cited by 324
Self-citationGlucose‐Responsive Insulin and Delivery Systems: Innovation and Translation
Wang, J., Wang, Z., Yu, J., Kahkoska, A. R., Buse, J. B., & Gu, Z. (2020) · Advanced Materials · doi:10.1002/adma.201902004 · Cited by 295
Self-citationBiocatalytic cascades operating on macromolecular scaffolds and in confined environments
Vázquez-González, M., Wang, C., & Willner, I. (2020) · Nature Catalysis · doi:10.1038/s41929-020-0433-1 · Cited by 293
Stimuli-responsive transdermal microneedle patches
Makvandi, P., Jamaledin, R., Chen, G., Baghbantaraghdari, Z., Zare, E. N., Di Natale, C., Onesto, V., Vecchione, R., Lee, J., Tay, F. R., et al. (2021) · Materials Today · doi:10.1016/j.mattod.2021.03.012 · Cited by 283
Self-citationInsulin delivery systems combined with microneedle technology
Jin, X., Zhu, D. D., Chen, B. Z., Ashfaq, M., & Guo, X. D. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.03.011 · Cited by 275
Cryomicroneedles for transdermal cell delivery
Chang, H., Chew, S. W. T., Zheng, M., Lio, D. C. S., Wiraja, C., Mei, Y., Ning, X., Cui, M., Than, A., Shi, P., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00720-1 · Cited by 265
Recent Advances in Nanocarrier-Assisted Therapeutics Delivery Systems
Su, S., & M. Kang, P. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12090837 · Cited by 259
ROS-responsive drug delivery systems for biomedical applications
Tao, W., & He, Z. (2018) · Asian Journal of Pharmaceutical Sciences · doi:10.1016/j.ajps.2017.11.002 · Cited by 255
Recent Progress in Glucose-Responsive Insulin
Liu, Y., Wang, S., Wang, Z., Yu, J., Wang, J., Buse, J. B., & Gu, Z. (2024) · Diabetes · doi:10.2337/dbi23-0028 · Cited by 19
Self-citationLong-acting glucose-responsive insulin with swift onset-of-action
Liu, W., Zhang, J., Wang, Y., He, Y., Wang, Y., Wei, X., Yao, Y., Xu, J., Zhang, W., Sheng, T., et al. (2025) · Journal of Controlled Release · doi:10.1016/j.jconrel.2025.113826 · Cited by 5
Self-citation
Metadata
- Authors
- Yu, J., Qian, C., Zhang, Y., Cui, Z., Zhu, Y., Shen, Q., Ligler, F. S., Buse, J. B., & Gu, Z.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-01-12
- Volume
- 17
- Issue
- 2
- Pages
- 733-739
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2579700567
- Cited by
- 280
- References
- 39
- FWCI
- 16.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.