Wearable Osmotic-Capillary Patch for Prolonged Sweat Harvesting and Sensing
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Biomarkers in sweat are a largely untapped source of health information. Most of the currently available sweat harvesting and testing devices are incapable of operating under low-sweat rates such as those experienced by humans at rest. Here we analyze the in vitro and in vivo sampling of sweat through osmosis via the use of a hydrogel interfaced with the skin, without need for active perspiration. The hydrogel also interfaces with paper-based microfluidics to transport the fluid via capillary forces toward a testing zone and then evaporation pad. We show that the hydrogel solute content and area of the evaporation pad regulate the long-term extraction of sweat and its associated biomarkers. The results indicate that the platform can sample biomarkers from a model skin system continuously for approximately 12 h. On-skin testing of the platform on both resting and exercising human subjects confirms that it can sample sweat lactate directly from the surface of skin. The results highlight that lactate in sweat increases with exercise and as a direct result of muscle activity. Implementation of such new principles for sweat fluid harvesting and management via wearable patch devices can contribute toward the advancement of next generation wearables.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Imani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Noninvasive Alcohol Monitoring Using a Wearable Tattoo-Based Iontophoretic-Biosensing System
Kim, J., Jeerapan, I., Imani, S., Cho, T. N., Bandodkar, A., Cinti, S., Mercier, P. P., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00356 · Cited by 599
Martín, A., Kim, J., Kurniawan, J. F., Sempionatto, J. R., Moreto, J. R., Tang, G., Campbell, A. S., Shin, A., Lee, M. Y., Liu, X., et al. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00729 · Cited by 475
Clinical use of lactate monitoring in critically ill patients
Bakker, J., Nijsten, M. W., & Jansen, T. C. (2013) · Annals of Intensive Care · doi:10.1186/2110-5820-3-12 · Cited by 473
A wearable multisensing patch for continuous sweat monitoring
Anastasova, S., Crewther, B., Bembnowicz, P., Curto, V., Ip, H. M., Rosa, B., & Yang, G.-Z. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.038 · Cited by 443
Wearable Sensors for Biochemical Sweat Analysis
Bandodkar, A. J., Jeang, W. J., Ghaffari, R., & Rogers, J. A. (2019) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061318-114910 · Cited by 387
Choi, J., Bandodkar, A. J., Reeder, J. T., Ray, T. R., Turnquist, A., Kim, S. B., Nyberg, N., Hourlier-Fargette, A., Model, J. B., Aranyosi, A. J., et al. (2019) · ACS Sensors · doi:10.1021/acssensors.8b01218 · Cited by 365
Reeder, J. T., Choi, J., Xue, Y., Gutruf, P., Hanson, J., Liu, M., Ray, T., Bandodkar, A. J., Avila, R., Xia, W., et al. (2019) · Science Advances · doi:10.1126/sciadv.aau6356 · Cited by 308
Lactate in human sweat: a critical review of research to the present day
Derbyshire, P. J., Barr, H., Davis, F., & Higson, S. P. J. (2012) · The Journal of Physiological Sciences · doi:10.1007/s12576-012-0213-z · Cited by 280
Sekine, Y., Kim, S. B., Zhang, Y., Bandodkar, A. J., Xu, S., Choi, J., Irie, M., Ray, T. R., Kohli, P., Kozai, N., et al. (2018) · Lab on a Chip · doi:10.1039/c8lc00530c · Cited by 242
A wearable patch for continuous monitoring of sweat electrolytes during exertion
Alizadeh, A., Burns, A., Lenigk, R., Gettings, R., Ashe, J., Porter, A., McCaul, M., Barrett, R., Diamond, D., White, P., et al. (2018) · Lab on a Chip · doi:10.1039/c8lc00510a · Cited by 180
Analysis of metabolites in sweat as a measure of physical condition
Mitsubayashi, K., Suzuki, M., Tamiya, E., & Karube, I. (1994) · Analytica Chimica Acta · doi:10.1016/0003-2670(94)80004-9 · Cited by 153
Wearable multiplexed biosensor system toward continuous monitoring of metabolites
Yokus, M. A., Songkakul, T., Pozdin, V. A., Bozkurt, A., & Daniele, M. A. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112038 · Cited by 153
The relationship between exercise intensity and the sweat lactate excretion rate
Buono, M. J., Lee, N. V. L., & Miller, P. W. (2010) · The Journal of Physiological Sciences · doi:10.1007/s12576-009-0073-3 · Cited by 128
Lin, S., Wang, B., Zhao, Y., Shih, R., Cheng, X., Yu, W., Hojaiji, H., Lin, H., Hoffman, C., Ly, D., et al. (2020) · ACS Sensors · doi:10.1021/acssensors.9b01727 · Cited by 114
Lactate and Ammonia Concentration in Blood and Sweat During Incremental Cycle Ergometer Exercise
Ament, W., Huizenga, J., Mook, G., Gips, C., & Verkerke, C. J. (1997) · International Journal of Sports Medicine · doi:10.1055/s-2007-972592 · Cited by 79
Hydrogel-enabled osmotic pumping for microfluidics: towards wearable human-device interfaces
Shay, T., Dickey, M. D., & Velev, O. D. (2017) · Lab on a Chip · doi:10.1039/c6lc01486k · Cited by 71
Self-citation
Cited by
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Self-citationNon-invasive monitoring of interstitial fluid lactate through an epidermal iontophoretic device
De la Paz, E., Saha, T., Del Caño, R., Seker, S., Kshirsagar, N., & Wang, J. (2023) · Talanta · doi:10.1016/j.talanta.2022.124122 · Cited by 63
Self-citationWearable Microfluidics for Continuous Assay
Lin, P.-H., Nien, H.-H., & Li, B.-R. (2023) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-091322-082930 · Cited by 28
Metadata
- Authors
- Saha, T., Fang, J., Mukherjee, S., Dickey, M. D., & Velev, O. D.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-02-15
- Volume
- 13
- Issue
- 7
- Pages
- 8071-8081
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W3130193465
- Cited by
- 89
- References
- 22
- FWCI
- 3.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.