The DOI matches its Crossref record; 78 of the 78 references it cites were found in a registry or an index.
Semiconducting Polymer Nanoparticles as Theranostic System for Near-Infrared-II Fluorescence Imaging and Photothermal Therapy under Safe Laser Fluence
Abstract
Theranostic systems combining fluorescence imaging in the second near-infrared window (NIR-II, 1000–1700 nm) and photothermal therapy (PTT) under safe laser fluence have great potential in preclinical research and clinical practice, but the development of such systems with sufficient effective NIR-II brightness and excellent photothermal properties is still challenging. Here we report a theranostic system based on semiconducting polymer nanoparticles (L1057 NPs) for NIR-II fluorescence imaging and PTT under a 980 nm laser irradiation, with low (25 mW/cm 2 ) and high (720 mW/cm 2 ) laser fluence, respectively. Taking into consideration multiple parameters including the extinction coefficient, the quantum yield, and the portion of emission in the NIR-II region, L1057 NPs have much higher effective NIR-II brightness than most reported organic NIR-II fluorophores. The high brightness, together with good stability and excellent biocompatibility, allows for real-time visualization of the whole body and brain vessels and the detection of cerebral ischemic stroke and tumors with high clarity. The excellent photothermal properties and high maximal permissible exposure limit at 980 nm allow L1057 NPs for PTT of tumors under safe laser fluence. This study demonstrates that L1057 NPs behave as an excellent theranostic system for NIR-II imaging and PTT under safe laser fluence and have great potential for a wide range of biomedical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Near-infrared fluorophores for biomedical imaging
Hong, G., Antaris, A. L., & Dai, H. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0010 · Cited by 2,985
The Essential Physics of Medical Imaging
Bushberg, J. T., Seibert, J. A., Leidholdt, E. M., Boone, J. M., & Goldschmidt, E. J. (2003) · Medical Physics · doi:10.1118/1.1585033 · Cited by 1,987
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
Self-citationOrganic molecule-based photothermal agents: an expanding photothermal therapy universe
Jung, H. S., Verwilst, P., Sharma, A., Shin, J., Sessler, J. L., & Kim, J. S. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00522a · Cited by 1,583
Image-guided cancer surgery using near-infrared fluorescence
Vahrmeijer, A. L., Hutteman, M., van der Vorst, J. R., van de Velde, C. J. H., & Frangioni, J. V. (2013) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2013.123 · Cited by 1,466
A route to brightly fluorescent carbon nanotubes for near-infrared imaging in mice
Welsher, K., Liu, Z., Sherlock, S. P., Robinson, J. T., Chen, Z., Daranciang, D., & Dai, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.294 · Cited by 1,287
Highly Fluorescent Semiconducting Polymer Dots for Biology and Medicine
Wu, C., & Chiu, D. T. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201205133 · Cited by 1,101
He, S., Song, J., Qu, J., & Cheng, Z. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00234g · Cited by 1,021
Multifunctional in vivo vascular imaging using near-infrared II fluorescence
Hong, G., Lee, J. C., Robinson, J. T., Raaz, U., Xie, L., Huang, N. F., Cooke, J. P., & Dai, H. (2012) · Nature Medicine · doi:10.1038/nm.2995 · Cited by 995
Recent Advances of Optical Imaging in the Second Near‐Infrared Window
Kenry, Duan, Y., & Liu, B. (2018) · Advanced Materials · doi:10.1002/adma.201802394 · Cited by 810
Cited by
Huang, Y., Guo, X., Wu, Y., Chen, X., Feng, L., Xie, N., & Shen, G. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-01745-z · Cited by 490
Light: A Magical Tool for Controlled Drug Delivery
Tao, Y., Chan, H. F., Shi, B., Li, M., & Leong, K. W. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202005029 · Cited by 309
The Chemistry of Organic Contrast Agents in the NIR‐II Window
Mu, J., Xiao, M., Shi, Y., Geng, X., Li, H., Yin, Y., & Chen, X. (2022) · Angewandte Chemie International Edition · doi:10.1002/anie.202114722 · Cited by 305
Wang, L., Li, N., Wang, W., Mei, A., Shao, J., Wang, W., & Dong, X. (2024) · ACS Nano · doi:10.1021/acsnano.3c12316 · Cited by 127
NIR‐II Organic Nanotheranostics for Precision Oncotherapy
Dai, H., Wang, X., Shao, J., Wang, W., Mou, X., & Dong, X. (2021) · Small · doi:10.1002/smll.202102646 · Cited by 110
Metadata
- Authors
- Yang, Y., Fan, X., Li, L., Yang, Y., Nuernisha, A., Xue, D., He, C., Qian, J., Hu, Q., Chen, H., Liu, J., & Huang, W.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-02-05
- Volume
- 14
- Issue
- 2
- Pages
- 2509-2521
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W3004937882
- Cited by
- 307
- References
- 78
- FWCI
- 15.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Semiconducting Polymer Nanoparticles as Theranostic System for Near-Infrared-II Fluorescence Imaging and Photothermal Therapy under Safe Laser Fluence. https://app.cochat.ai/papers/10.1021/acsnano.0c00043
- The paper
- Yang, Y., Fan, X., Li, L., Yang, Y., Nuernisha, A., Xue, D., He, C., Qian, J., Hu, Q., Chen, H., Liu, J., & Huang, W. (2020). Semiconducting Polymer Nanoparticles as Theranostic System for Near-Infrared-II Fluorescence Imaging and Photothermal Therapy under Safe Laser Fluence. ACS Nano. https://doi.org/10.1021/acsnano.0c00043
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.