The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Single Molecule Protein Detection with Attomolar Sensitivity Using Droplet Digital Enzyme-Linked Immunosorbent Assay
Abstract
Many proteins are present at low concentrations in biological samples, and therefore, techniques for ultrasensitive protein detection are necessary. To overcome challenges with sensitivity, the digital enzyme-linked immunosorbent assay (ELISA) was developed, which is 1000× more sensitive than conventional ELISA and allows sub-femtomolar protein detection. However, this sensitivity is still not sufficient to measure many proteins in various biological samples, thereby limiting our ability to detect and discover biomarkers. To overcome this limitation, we developed droplet digital ELISA (ddELISA), a simple approach for detecting low protein levels using digital ELISA and droplet microfluidics. ddELISA achieves maximal sensitivity by improving the sampling efficiency and counting more target molecules. ddELISA can detect proteins in the low attomolar range and is up to 25-fold more sensitive than digital ELISA using Single Molecule Arrays (Simoa), the current gold standard tool for ultrasensitive protein detection. Using ddELISA, we measured the LINE1/ORF1 protein, a potential cancer biomarker that has not been previously measured in serum. Additionally, due to the simplicity of our device design, ddELISA is promising for point-of-care applications. Thus, ddELISA will facilitate the discovery of biomarkers that have never been measured before for various clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly parallel genome-wide expression profiling of individual cells using nanoliter droplets.
Macosko, E. Z., Basu, A., Satija, R., Nemesh, J., Shekhar, K., Goldman, M., Tirosh, I., Bialas, A. R., Kamitaki, N., Martersteck, E. M., et al. (2015) · Cell · doi:10.1016/j.cell.2015.05.002 · Cited by 7,110
Self-citationAnderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Nucleic acid detection with CRISPR-Cas13a/C2c2
Gootenberg, J. S., Abudayyeh, O. O., Lee, J. W., Essletzbichler, P., Dy, A. J., Joung, J., Verdine, V., Donghia, N., Daringer, N. M., Freije, C. A., et al. (2017) · Science · doi:10.1126/science.aam9321 · Cited by 3,844
Droplet barcoding for single-cell transcriptomics applied to embryonic stem cells
Klein, A. M., Mazutis, L., Akartuna, I., Tallapragada, N., Veres, A., Li, V., Peshkin, L., Weitz, D. A., & Kirschner, M. W. (2015) · Cell · doi:10.1016/j.cell.2015.04.044 · Cited by 3,356
Self-citationHigh-throughput droplet digital PCR system for absolute quantitation of DNA copy number
Hindson, B. J., Ness, K. D., Masquelier, D. A., Belgrader, P., Heredia, N. J., Makarewicz, A. J., Bright, I. J., Lucero, M. Y., Hiddessen, A. L., Legler, T. C., et al. (2011) · Analytical Chemistry · doi:10.1021/ac202028g · Cited by 2,792
Rissin, D. M., Kan, C. W., Campbell, T. G., Howes, S. C., Fournier, D. R., Song, L., Piech, T., Patel, P. P., Chang, L., Rivnak, A. J., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1641 · Cited by 2,119
Self-citationEmerging Droplet Microfluidics
Shang, L., Cheng, Y., & Zhao, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00848 · Cited by 1,584
Absolute quantification by droplet digital PCR versus analog real-time PCR
Hindson, C. M., Chevillet, J. R., Briggs, H. A., Gallichotte, E. N., Ruf, I. K., Hindson, B. J., Vessella, R. L., & Tewari, M. (2013) · Nature Methods · doi:10.1038/nmeth.2633 · Cited by 1,488
Single-cell analysis and sorting using droplet-based microfluidics
Mazutis, L., Gilbert, J., Ung, W. L., Weitz, D. A., Griffiths, A. D., & Heyman, J. A. (2013) · Nature Protocols · doi:10.1038/nprot.2013.046 · Cited by 1,355
Self-citationUltrahigh-throughput screening in drop-based microfluidics for directed evolution
Agresti, J. J., Antipov, E., Abate, A. R., Ahn, K., Rowat, A. C., Baret, J.-C., Marquez, M., Klibanov, A. M., Griffiths, A. D., & Weitz, D. A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910781107 · Cited by 1,149
Self-citationMining the plasma proteome for cancer biomarkers
Hanash, S. M., Pitteri, S. J., & Faca, V. M. (2008) · Nature · doi:10.1038/nature06916 · Cited by 891
Transposable elements in cancer
Burns, K. H. (2017) · Nature Reviews Cancer · doi:10.1038/nrc.2017.35 · Cited by 572
The Clinical Plasma Proteome: A Survey of Clinical Assays for Proteins in Plasma and Serum
Anderson, N. L. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.126706 · Cited by 562
Measurement of biomarker proteins for point-of-care early detection and monitoring of cancer
Rusling, J. F., Kumar, C. V., Gutkind, J. S., & Patel, V. (2010) · The Analyst · doi:10.1039/c0an00204f · Cited by 552
Uhlén, M., Karlsson, M. J., Hober, A., Svensson, A.-S., Scheffel, J., Kotol, D., Zhong, W., Tebani, A., Strandberg, L., Edfors, F., et al. (2019) · Science Signaling · doi:10.1126/scisignal.aaz0274 · Cited by 495
Wilson, D. H., Rissin, D. M., Kan, C. W., Fournier, D. R., Piech, T., Campbell, T. G., Meyer, R. E., Fishburn, M. W., Cabrera, C., Patel, P. P., et al. (2016) · SLAS Technology · doi:10.1177/2211068215589580 · Cited by 470
Surface acoustic wave (SAW) directed droplet flow in microfluidics for PDMS devices
Franke, T., Abate, A. R., Weitz, D. A., & Wixforth, A. (2009) · Lab on a Chip · doi:10.1039/b906819h · Cited by 369
Self-citationScaling by shrinking: empowering single-cell 'omics' with microfluidic devices
Prakadan, S. M., Shalek, A. K., & Weitz, D. A. (2017) · Nature Reviews Genetics · doi:10.1038/nrg.2017.15 · Cited by 325
Self-citation1-Million droplet array with wide-field fluorescence imaging for digital PCR
Hatch, A. C., Fisher, J. S., Tovar, A. R., Hsieh, A. T., Lin, R., Pentoney, S. L., Yang, D. L., & Lee, A. P. (2011) · Lab on a Chip · doi:10.1039/c1lc20561g · Cited by 317
Highly Sensitive and Multiplexed Protein Measurements
Cohen, L., & Walt, D. R. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00257 · Cited by 294
Self-citationAbseq: Ultrahigh-throughput single cell protein profiling with droplet microfluidic barcoding
Shahi, P., Kim, S. C., Haliburton, J. R., Gartner, Z. J., & Abate, A. R. (2017) · Scientific Reports · doi:10.1038/srep44447 · Cited by 259
Rissin, D. M., Fournier, D. R., Piech, T., Kan, C. W., Campbell, T. G., Song, L., Chang, L., Rivnak, A. J., Patel, P. P., Provuncher, G. K., et al. (2011) · Analytical Chemistry · doi:10.1021/ac103161b · Cited by 255
Ultrarapid Generation of Femtoliter Microfluidic Droplets for Single-Molecule-Counting Immunoassays
Shim, J.-U., Ranasinghe, R. T., Smith, C. A., Ibrahim, S. M., Hollfelder, F., Huck, W. T. S., Klenerman, D., & Abell, C. (2013) · ACS Nano · doi:10.1021/nn401661d · Cited by 218
Large-scale femtoliter droplet array for digital counting of single biomolecules
Kim, S. H., Iwai, S., Araki, S., Sakakihara, S., Iino, R., & Noji, H. (2012) · Lab on a Chip · doi:10.1039/c2lc40632b · Cited by 212
Rissin, D. M., & Walt, D. R. (2006) · Nano Letters · doi:10.1021/nl060227d · Cited by 195
Self-citationYelleswarapu, V., Buser, J. R., Haber, M., Baron, J., Inapuri, E., & Issadore, D. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1814110116 · Cited by 185
Rong, Z., Wang, Q., Sun, N., Jia, X., Wang, K., Xiao, R., & Wang, S. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.12.043 · Cited by 184
Zhang, K., Liang, Q., Ma, S., et al. (2009) · Lab on a Chip · doi:10.1039/b906229g · Cited by 164
The Human Long Interspersed Element-1 Retrotransposon: An Emerging Biomarker of Neoplasia
Ardeljan, D., Taylor, M. S., Ting, D. T., & Burns, K. H. (2017) · Clinical Chemistry · doi:10.1373/clinchem.2016.257444 · Cited by 156
A single-molecule enzymatic assay in a directly accessible femtoliter droplet array
Sakakihara, S., Araki, S., Iino, R., & Noji, H. (2010) · Lab on a Chip · doi:10.1039/c0lc00062k · Cited by 141
Single-Molecule Arrays for Protein and Nucleic Acid Analysis
Cohen, L., & Walt, D. R. (2017) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061516-045340 · Cited by 138
Self-citationAkama, K., Shirai, K., & Suzuki, S. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b01148 · Cited by 137
Distinct and Long-Lived Activity States of Single Enzyme Molecules
Rissin, D. M., Gorris, H. H., & Walt, D. R. (2008) · Journal of the American Chemical Society · doi:10.1021/ja711414f · Cited by 128
Self-citationLINE-1 in cancer: multifaceted functions and potential clinical implications
Lu, X., Hui-Ying, X., Qi, X., Jiang, X., & Ma, S. (2015) · Genetics in Medicine · doi:10.1038/gim.2015.119 · Cited by 124
Blood-Based Proteomic Biomarkers of Alzheimer’s Disease Pathology
Baird, A. L., Westwood, S., & Lovestone, S. (2015) · Frontiers in Neurology · doi:10.3389/fneur.2015.00236 · Cited by 123
Kan, C. W., Rivnak, A. J., Campbell, T. G., Piech, T., Rissin, D. M., Mösl, M., Peterça, A., Niederberger, H.-P., Minnehan, K. A., Patel, P. P., et al. (2011) · Lab on a Chip · doi:10.1039/c2lc20744c · Cited by 122
Stochastic inhibitor release and binding from single-enzyme molecules
Gorris, H. H., Rissin, D. M., & Walt, D. R. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0705411104 · Cited by 121
Self-citationDigital direct detection of microRNAs using single molecule arrays
Cohen, L., Hartman, M. R., Amardey-Wellington, A., & Walt, D. R. (2017) · Nucleic Acids Research · doi:10.1093/nar/gkx542 · Cited by 118
Self-citationRissin, D. M., & Walt, D. R. (2006) · Journal of the American Chemical Society · doi:10.1021/ja058425e · Cited by 95
Self-citationWu, D., Milutinovic, M. D., & Walt, D. R. (2015) · The Analyst · doi:10.1039/c5an01238d · Cited by 92
Self-citationKonry, T., Hayman, R. B., & Walt, D. R. (2009) · Analytical Chemistry · doi:10.1021/ac900694y · Cited by 82
Self-citationA rapid triage test for active pulmonary tuberculosis in adult patients with persistent cough
Ahmad, R., Xie, L., Pyle, M., Fernández-Suárez, M., Broger, T., Steinberg, D., Ame, S. M., Lucero, M., Szucs, M. J., MacMullan, M. A., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aaw8287 · Cited by 65
Self-citationSingle-molecule analysis of nucleic acid biomarkers – A review
Gilboa, T., Garden, P. M., & Cohen, L. (2020) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.03.001 · Cited by 65
Self-citationOptical separation of droplets on a microfluidic platform
Jung, J. H., Lee, K. H., Lee, K. S., Ha, B. H., Oh, Y. S., & Sung, H. J. (2013) · Microfluidics and Nanofluidics · doi:10.1007/s10404-013-1263-0 · Cited by 39
Digital enzyme assay using attoliter droplet array
Ono, T., Ichiki, T., & Noji, H. (2018) · The Analyst · doi:10.1039/c8an01152d · Cited by 31
Single-molecule measurements in microwells for clinical applications
Wu, C., Maley, A. M., & Walt, D. R. (2019) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2019.1700903 · Cited by 30
Self-citationCohen, L., & Walt, D. R. (2018) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.8b00601 · Cited by 25
Self-citationLabel-free single-cell protein quantification using a drop-based mix-and-read system
Abbaspourrad, A., Zhang, H., Tao, Y., Cui, N., Asahara, H., Zhou, Y. F., Yue, D., Koehler, S. A., Ung, W. L., Heyman, J. A., et al. (2015) · Scientific Reports · doi:10.1038/srep12756 · Cited by 24
Self-citationA mix-and-read drop-based in vitro two-hybrid method for screening high-affinity peptide binders
Cui, N., Zhang, H., Schneider, N., Tao, Y., Asahara, H., Sun, Z., Cai, Y., Koehler, S. A., de Greef, T. F. A., Abbaspourrad, A., et al. (2016) · Scientific Reports · doi:10.1038/srep22575 · Cited by 15
Self-citation
Cited by
Ultrasensitive and Highly Specific Lateral Flow Assays for Point-of-Care Diagnosis
Liu, Y., Zhan, L., Qin, Z., Sackrison, J., & Bischof, J. C. (2021) · ACS Nano · doi:10.1021/acsnano.0c10035 · Cited by 626
Digital colloid-enhanced Raman spectroscopy by single-molecule counting
Bi, X., Czajkowsky, D. M., Shao, Z., & Ye, J. (2024) · Nature · doi:10.1038/s41586-024-07218-1 · Cited by 305
Development and future of droplet microfluidics
Nan, L., Zhang, H., Weitz, D. A., & Shum, H. C. (2024) · Lab on a Chip · doi:10.1039/d3lc00729d · Cited by 253
Self-citationReverse Transcriptase Inhibition Disrupts Repeat Element Life Cycle in Colorectal Cancer.
Rajurkar, M., Parikh, A. R., Solovyov, A., You, E., Kulkarni, A. S., Chu, C., Xu, K. H., Jaicks, C., Taylor, M. S., Wu, C., et al. (2022) · Cancer Discovery · doi:10.1158/2159-8290.cd-21-1117 · Cited by 61
Self-citation
Metadata
- Authors
- Cohen, L., Cui, N., Cai, Y., Garden, P. M., Li, X., Weitz, D. A., & Walt, D. R.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-06-26
- Volume
- 14
- Issue
- 8
- Pages
- 9491-9501
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W3037216136
- Cited by
- 263
- References
- 49
- FWCI
- 8.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.