“Four-In-One” Design of a Hemicyanine-Based Modular Scaffold for High-Contrast Activatable Molecular Afterglow Imaging
The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Afterglow luminescence (long persistent luminescence) holds great potential for nonbackground molecular imaging. However, current afterglow probes are mainly nanoparticles, and afterglow imaging systems based on organic small molecules are still lacking and have rarely been reported. Moreover, the lack of reactive sites and a universal molecular scaffold makes it difficult to design activatable afterglow probes. To address these issues, this study reports a novel kind of hemicyanine-based molecule scaffolds with stimuli-responsive afterglow luminescence, which is dependent on an intramolecular cascade photoreaction between 1 O 2 and the afterglow molecule to store the photoenergy for delayed luminescence after light cessation. As a proof of concept, three modular activatable molecular afterglow probes (MAPs) with a “four-in-one” molecular design by integrating a stimuli-responsive unit, 1 O 2 -generating unit, 1 O 2 -capturing unit, and luminescent unit into one probe are customized for quantification and imaging of targets including pH, superoxide anions, and aminopeptidase. Notably, MAPs show higher sensitivity in afterglow imaging than in fluorescence imaging because the responsive unit simultaneously controls the initiation of fluorescence (S 1 to S 0 ) and 1 O 2 generation (S 1 to T 1 ). Finally, MAPs are applied for high-contrast afterglow imaging of drug-induced hepatotoxicity, which is poorly evaluated in clinics and drug discovery. By reporting the sequential occurrence of oxidative stress and upregulation of aminopeptidase, such activatable afterglow probes allow noninvasive imaging of hepatotoxicity earlier than the serological and histology manifestation, indicating their promise for early diagnosis of hepatotoxicity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Long persistent phosphors—from fundamentals to applications
Li, Y., Gecevicius, M., & Qiu, J. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00582e · Cited by 1,368
Molecular imaging in drug development
Willmann, J. K., van Bruggen, N., Dinkelborg, L. M., & Gambhir, S. S. (2008) · Nature Reviews Drug Discovery · doi:10.1038/nrd2290 · Cited by 1,171
Li, J., & Pu, K. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00001h · Cited by 1,168
Maldiney, T., Bessière, A., Seguin, J., Teston, E., Sharma, S. K., Viana, B., Bos, A. J. J., Dorenbos, P., Bessodes, M., Gourier, D., et al. (2014) · Nature Materials · doi:10.1038/nmat3908 · Cited by 1,096
Molecular afterglow imaging with bright, biodegradable polymer nanoparticles
Miao, Q., Xie, C., Zhen, X., Lyu, Y., Duan, H., Liu, X., Jokerst, J. V., & Pu, K. (2017) · Nature Biotechnology · doi:10.1038/nbt.3987 · Cited by 975
Excited State Modulation for Organic Afterglow: Materials and Applications
Xu, S., Chen, R., Zheng, C., & Huang, W. (2016) · Advanced Materials · doi:10.1002/adma.201602604 · Cited by 851
Molecular optical imaging probes for early diagnosis of drug-induced acute kidney injury
Huang, J., Li, J., Lyu, Y., Miao, Q., & Pu, K. (2019) · Nature Materials · doi:10.1038/s41563-019-0378-4 · Cited by 721
X-ray-activated persistent luminescence nanomaterials for NIR-II imaging
Pei, P., Chen, Y., Sun, C., Fan, Y., Yang, Y., Liu, X., Lu, L., Zhao, M., Zhang, H., Zhao, D., et al. (2021) · Nature Nanotechnology · doi:10.1038/s41565-021-00922-3 · Cited by 718
McGill, M. R., & Jaeschke, H. (2013) · Pharmaceutical Research · doi:10.1007/s11095-013-1007-6 · Cited by 704
A Unique Approach to Development of Near-Infrared Fluorescent Sensors for in Vivo Imaging
Yuan, L., Lin, W., Zhao, S., Gao, W., Chen, B., He, L., & Zhu, S. (2012) · Journal of the American Chemical Society · doi:10.1021/ja305802v · Cited by 679
Shuhendler, A. J., Pu, K., Cui, L., Uetrecht, J. P., & Rao, J. (2014) · Nature Biotechnology · doi:10.1038/nbt.2838 · Cited by 623
Ni, X., Zhang, X., Duan, X., Zheng, H.-L., Xue, X.-S., & Ding, D. (2019) · Nano Letters · doi:10.1021/acs.nanolett.8b03936 · Cited by 483
Self-citationMultimodal Biophotonics of Semiconducting Polymer Nanoparticles
Jiang, Y., & Pu, K. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00242 · Cited by 478
Molecular Probes for Autofluorescence-Free Optical Imaging
Jiang, Y., & Pu, K. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00506 · Cited by 426
Molecular imaging and disease theranostics with renal-clearable optical agents
Cheng, P., & Pu, K. (2021) · Nature Reviews Materials · doi:10.1038/s41578-021-00328-6 · Cited by 413
A generic approach towards afterglow luminescent nanoparticles for ultrasensitive in vivo imaging
Jiang, Y., Huang, J., Zhen, X., Zeng, Z., Li, J., Xie, C., Miao, Q., Chen, J., Chen, P., & Pu, K. (2019) · Nature Communications · doi:10.1038/s41467-019-10119-x · Cited by 311
Cheng, D., Peng, J., Lv, Y., Su, D., Liu, D., Chen, M., Yuan, L., & Zhang, X. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b01374 · Cited by 308
Self-citationMechanisms of drug-induced liver injury: from bedside to bench
Tujios, S., & Fontana, R. J. (2011) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2011.22 · Cited by 277
H2S-activatable near-infrared afterglow luminescent probes for sensitive molecular imaging in vivo
Wu, L., Ishigaki, Y., Hu, Y., Sugimoto, K., Zeng, W., Harimoto, T., Sun, Y., He, J., Suzuki, T., Jiang, X., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-14307-y · Cited by 251
Lyu, Y., Cui, D., Huang, J., Fan, W., Miao, Y., & Pu, K. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201900092 · Cited by 234
Lu, C., Zhang, C., Wang, P., Zhao, Y., Yang, Y., Wang, Y., Yuan, H., Qu, S., Zhang, X., Song, G., et al. (2020) · Chem · doi:10.1016/j.chempr.2020.06.024 · Cited by 220
Self-citationPeng, J., Samanta, A., Zeng, X., Han, S., Wang, L., Su, D., Loong, D. T. B., Kang, N., Park, S., All, A. H., et al. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201612020 · Cited by 216
Xie, C., Zhen, X., Miao, Q., Lyu, Y., & Pu, K. (2018) · Advanced Materials · doi:10.1002/adma.201801331 · Cited by 214
Liu, H.-W., Hu, X.-X., Li, K., Liu, Y., Rong, Q., Zhu, L., Yuan, L., Qu, F.-L., Zhang, X.-B., & Tan, W. (2017) · Chem. Sci. · doi:10.1039/c7sc03454g · Cited by 198
Self-citationRenal clearable polyfluorophore nanosensors for early diagnosis of cancer and allograft rejection
Huang, J., Chen, X., Jiang, Y., Zhang, C., He, S., Wang, H., & Pu, K. (2022) · Nature Materials · doi:10.1038/s41563-022-01224-2 · Cited by 193
Hananya, N., & Shabat, D. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201706969 · Cited by 191
Chen, C., Gao, H., Ou, H., Kwok, R. T. K., Tang, Y., Zheng, D., & Ding, D. (2022) · Journal of the American Chemical Society · doi:10.1021/jacs.1c11455 · Cited by 186
Reactive species involved in the regioselective photooxidation of heptamethine cyanines
Nani, R. R., Kelley, J. A., Ivanic, J., & Schnermann, M. J. (2015) · Chemical Science · doi:10.1039/c5sc02396c · Cited by 162
Liu, Y., Teng, L., Chen, L., Ma, H., Liu, H., & Zhang, X. (2018) · Chemical Science · doi:10.1039/c8sc01684d · Cited by 157
Self-citationAn Organic Afterglow Protheranostic Nanoassembly
He, S., Xie, C., Jiang, Y., & Pu, K. (2019) · Advanced Materials · doi:10.1002/adma.201902672 · Cited by 154
Near-Infrared Afterglow Luminescence of Chlorin Nanoparticles for Ultrasensitive In Vivo Imaging
Chen, W., Zhang, Y., Li, Q., Jiang, Y., Zhou, H., Liu, Y., Miao, Q., & Gao, M. (2022) · Journal of the American Chemical Society · doi:10.1021/jacs.1c10168 · Cited by 148
Self-citationMills, J. A., Liu, F., Jarrett, T. R., Fletcher, N. L., & Thurecht, K. J. (2022) · Biomaterials Science · doi:10.1039/d2bm00181k · Cited by 138
In vivo nanoparticle-mediated radiopharmaceutical-excited fluorescence molecular imaging
Hu, Z., Qu, Y., Wang, K., Zhang, X., Zha, J., Song, T., Bao, C., Liu, H., Wang, J., Wang, J., et al. (2015) · Nature Communications · doi:10.1038/ncomms8560 · Cited by 135
Self-citationRatiometric afterglow luminescent nanoplatform enables reliable quantification and molecular imaging
Liu, Y., Teng, L., Lyu, Y., Song, G., Zhang, X., & Tan, W. (2022) · Nature Communications · doi:10.1038/s41467-022-29894-1 · Cited by 129
Self-citationRatiometric fluorescent probes for capturing endogenous hypochlorous acid in the lungs of mice
Zhang, X., Zhao, W., Li, B., Li, W., Zhang, C., Hou, X., Jiang, J., & Dong, Y. (2018) · Chemical Science · doi:10.1039/c8sc03226b · Cited by 118
Self-citationLiu, Y., Teng, L., Xu, C., Liu, H., Xu, S., Guo, H., Yuan, L., & Zhang, X. (2019) · Chemical Science · doi:10.1039/c9sc03628h · Cited by 116
Self-citationPirovano, G., Roberts, S. S., Kossatz, S., & Reiner, T. (2020) · Journal of Nuclear Medicine · doi:10.2967/jnumed.119.238279 · Cited by 110
Wang, Y., Song, G., Liao, S., Qin, Q., Zhao, Y., Shi, L., Guan, K., Gong, X., Wang, P., Yin, X., et al. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202104127 · Cited by 92
Self-citationJiang, Y. Y., Li, Y., Richard, C., Scherman, D., & Liu, Y. (2019) · Journal of Materials Chemistry B · doi:10.1039/c9tb00378a · Cited by 74
Self-citationAn aggregation-induced emission dye-powered afterglow luminogen for tumor imaging
Xu, Y., Yang, W., Yao, D., Bian, K., Zeng, W., Liu, K., Wang, D., & Zhang, B. (2020) · Chemical Science · doi:10.1039/c9sc04901k · Cited by 70
Ramírez‐García, G., Gutiérrez‐Granados, S., Gallegos‐Corona, M. A., Palma‐Tirado, L., d’Orlyé, F., Varenne, A., Mignet, N., Richard, C., & Martínez‐Alfaro, M. (2017) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2017.07.015 · Cited by 63
Song, X., Fanelli, M. G., Cook, J. M., Bai, F., & Parish, C. A. (2012) · The Journal of Physical Chemistry A · doi:10.1021/jp301919g · Cited by 52
Zhuang, H., Li, B., Zhao, M., Wei, P., Yuan, W., Zhang, M., Han, X., Chen, Y., & Yi, T. (2020) · Nanoscale · doi:10.1039/d0nr00963f · Cited by 30
Cited by
Design strategies and applications of cyanine dyes in phototherapy
Yuan, J., Yang, H., Huang, W., Liu, S., Zhang, H., Zhang, X., & Peng, X. (2025) · Chemical Society Reviews · doi:10.1039/d3cs00585b · Cited by 143
Self-citationActivatable Molecular Probes With Clinical Promise for NIR‐II Fluorescent Imaging
Chen, Z., Zhou, Y., Li, L., Ma, W., Li, Y., & Yang, Z. (2025) · Small · doi:10.1002/smll.202411787 · Cited by 26
Metadata
- Authors
- Liu, Y., Teng, L., Lou, X.-F., Zhang, X.-B., & Song, G.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2023-02-23
- Volume
- 145
- Issue
- 9
- Pages
- 5134-5144
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W4321749106
- Cited by
- 159
- References
- 43
- FWCI
- 11.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.