The DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.
Molecular Magnetic Resonance Imaging with Gd(III)-Based Contrast Agents: Challenges and Key Advances
Open accessAbstract
In an era of personalized medicine, the clinical community has become increasingly focused on understanding diseases at the cellular and molecular levels. Magnetic resonance imaging (MRI) is a powerful imaging modality for acquiring anatomical and functional information. However, it has limited applications in the field of molecular imaging due to its low sensitivity. To expand the capability of MRI to encompass molecular imaging applications, we introduced bioresponsive Gd(III)-based magnetic resonance contrast agents (GBCAs) in 1997. Since that time, many research groups across the globe have developed new examples of bioresponsive GBCAs. These contrast agents have shown great promise for visualizing several biochemical processes, such as gene expression, neuronal signaling, and hormone secretion. They are designed to be conditionally retained, or activated, in vivo in response to specific biochemical events of interest. As a result, an observed MR signal change can serve as a read-out for molecular events. A significant challenge for these probes is how to utilize them for noninvasive diagnostic and theranostic applications. This Perspective focuses on the design strategies that underlie bioresponsive probes, and describes the key advances made in recent years that are facilitating their application in vivo and ultimately in clinical translation. While the field of bioresponsive agents is embryonic, it is clear that many solutions to the experimental and clinical radiologic problems of today will be overcome by the probes of tomorrow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A biomarker that identifies senescent human cells in culture and in aging skin in vivo.
Dimri, G. P., Lee, X., Basile, G., Acosta, M., Scott, G., Roskelley, C., Medrano, E. E., Linskens, M., Rubelj, I., & Pereira-Smith, O. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.20.9363 · Cited by 7,477
Global quantification of mammalian gene expression control
Schwanhäusser, B., Busse, D., Li, N., Dittmar, G., Schuchhardt, J., Wolf, J., Chen, W., & Selbach, M. (2011) · Nature · doi:10.1038/nature10098 · Cited by 6,566
Gadolinium(III) Chelates as MRI Contrast Agents: Structure, Dynamics, and Applications
Caravan, P., Ellison, J. J., McMurry, T. J., & Lauffer, R. B. (1999) · Chemical Reviews · doi:10.1021/cr980440x · Cited by 4,483
HaloTag: A Novel Protein Labeling Technology for Cell Imaging and Protein Analysis
Los, G. V., Encell, L. P., McDougall, M. G., Hartzell, D. D., Karassina, N., Zimprich, C., Wood, M. G., Learish, R., Ohana, R. F., Urh, M., et al. (2008) · ACS Chemical Biology · doi:10.1021/cb800025k · Cited by 2,624
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577
Strategies for increasing the sensitivity of gadolinium based MRI contrast agents
Caravan, P. (2006) · Chemical Society Reviews · doi:10.1039/b510982p · Cited by 1,438
Lu, Y., Aimetti, A. A., Langer, R., & Gu, Z. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.75 · Cited by 1,421
Proton Relaxation Times in Paramagnetic Solutions. Effects of Electron Spin Relaxation
Bloembergen, N., & Morgan, L. O. (1961) · The Journal of Chemical Physics · doi:10.1063/1.1731684 · Cited by 1,348
Lanthanide Probes for Bioresponsive Imaging
Heffern, M. C., Matosziuk, L. M., & Meade, T. J. (2014) · Chemical Reviews · doi:10.1021/cr400477t · Cited by 1,202
Self-citationIn vivo visualization of gene expression using magnetic resonance imaging
Louie, A. Y., Hüber, M. M., Ahrens, E. T., Rothbächer, U., Moats, R., Jacobs, R. E., Fraser, S. E., & Meade, T. J. (2000) · Nature Biotechnology · doi:10.1038/73780 · Cited by 1,141
Self-citationProton Relaxation Times in Paramagnetic Solutions
Bloembergen, N. (1957) · The Journal of Chemical Physics · doi:10.1063/1.1743771 · Cited by 1,056
Hwang, L.-P., & Freed, J. H. (1975) · The Journal of Chemical Physics · doi:10.1063/1.431841 · Cited by 600
Caravan, P., Farrar, C. T., Frullano, L., & Uppal, R. (2009) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.267 · Cited by 513
MS-325: albumin-targeted contrast agent for MR angiography.
Lauffer, R. B., Parmelee, D. J., Dunham, S. U., Ouellet, H. S., Dolan, R. P., Witte, S., McMurry, T. J., & Walovitch, R. C. (1998) · Radiology · doi:10.1148/radiology.207.2.9577506 · Cited by 457
Laurent, S., Elst, L. V., & Muller, R. N. (2006) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.100 · Cited by 441
Manganese-based MRI contrast agents: past, present, and future
Pan, D., Schmieder, A. H., Wickline, S. A., & Lanza, G. M. (2011) · Tetrahedron · doi:10.1016/j.tet.2011.07.076 · Cited by 419
In vivo detection of single cells by MRI
Shapiro, E. M., Sharer, K., Skrtic, S., & Koretsky, A. P. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20718 · Cited by 378
Juers, D. H., Matthews, B. W., & Huber, R. E. (2012) · Protein Science · doi:10.1002/pro.2165 · Cited by 344
A “Smart” Magnetic Resonance Imaging Agent That Reports on Specific Enzymatic Activity
Moats, R. A., Fraser, S. E., & Meade, T. J. (1997) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199707261 · Cited by 330
Self-citationZhang, X.-A., Lovejoy, K. S., Jasanoff, A., & Lippard, S. J. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0702393104 · Cited by 294
What are normal relaxation times of tissues at 3 T?
Bojorquez, J. Z., Bricq, S., Acquitter, C., Brunotte, F., Walker, P. M., & Lalande, A. (2017) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2016.08.021 · Cited by 286
Incidence of Immediate Gadolinium Contrast Media Reactions
Prince, M. R., Zhang, H., Zou, Z., Staron, R. B., & Brill, P. W. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.4885 · Cited by 271
Que, E. L., & Chang, C. J. (2010) · Chem. Soc. Rev. · doi:10.1039/b914348n · Cited by 263
A Novel pH‐Sensitive MRI Contrast Agent
Zhang, S., Wu, K., & Sherry, A. D. (1999) · Angewandte Chemie International Edition · Cited by 259
Gd−Hydroxypyridinone (HOPO)-Based High-Relaxivity Magnetic Resonance Imaging (MRI) Contrast Agents
Datta, A., & Raymond, K. N. (2009) · Accounts of Chemical Research · doi:10.1021/ar800250h · Cited by 250
Correction: Corrigendum: Global quantification of mammalian gene expression control
Schwanhäusser, B., Busse, D., Li, N., Dittmar, G., Schuchhardt, J., Wolf, J., Chen, W., & Selbach, M. (2013) · Nature · doi:10.1038/nature11848 · Cited by 248
van Montfoort, J. E., Stieger, B., Meijer, D. K. F., Weinmann, H.-J., Meier, P. J., & Fattinger, K. E. (1999) · The Journal of Pharmacology and Experimental Therapeutics · doi:10.1016/s0022-3565(24)34879-7 · Cited by 223
Basic MR relaxation mechanisms and contrast agent design
De León‐Rodríguez, L. M., Martins, A. F., Pinho, M. C., Rofsky, N. M., & Sherry, A. D. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24787 · Cited by 211
Revisiting an old friend: manganese‐based MRI contrast agents
Pan, D., Caruthers, S. D., Senpan, A., Schmieder, A. H., Wickline, S. A., & Lanza, G. M. (2011) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.116 · Cited by 201
A review of responsive MRI contrast agents: 2005–2014
Hingorani, D. V., Bernstein, A. S., & Pagel, M. D. (2015) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.1629 · Cited by 199
Nahrendorf, M., Sosnovik, D., Chen, J. W., Panizzi, P., Figueiredo, J.-L., Aikawa, E., Libby, P., Swirski, F. K., & Weissleder, R. (2008) · Circulation · doi:10.1161/circulationaha.107.756510 · Cited by 197
Quantitative assay of senescence-associated β-galactosidase activity in mammalian cell extracts
Gary, R. K., & Kindell, S. M. (2005) · Analytical Biochemistry · doi:10.1016/j.ab.2005.06.003 · Cited by 195
The synthesis and in vitro testing of a zinc-activated MRI contrast agent
Major, J. L., Parigi, G., Luchinat, C., & Meade, T. J. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0706247104 · Cited by 184
Self-citationA New Gadolinium-Based MRI Zinc Sensor
Esqueda, A. C., López, J. A., Andreu-de-Riquer, G., Alvarado-Monzón, J. C., Ratnakar, J., Lubag, A. J. M., Sherry, A. D., & De León-Rodríguez, L. M. (2009) · Journal of the American Chemical Society · doi:10.1021/ja901875v · Cited by 173
Bimodal MR–PET Agent for Quantitative pH Imaging
Frullano, L., Catana, C., Benner, T., Sherry, A. D., & Caravan, P. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.201000075 · Cited by 172
Ye, D., Shuhendler, A. J., Pandit, P., Brewer, K. D., Tee, S. S., Cui, L., Tikhomirov, G., Rutt, B., & Rao, J. (2014) · Chem. Sci. · doi:10.1039/c4sc01392a · Cited by 169
A Smart Magnetic Resonance Contrast Agent for Selective Copper Sensing
Que, E. L., & Chang, C. J. (2006) · Journal of the American Chemical Society · doi:10.1021/ja065264l · Cited by 164
Bhorade, R., Weissleder, R., Nakakoshi, T., Moore, A., & Tung, C.-H. (2000) · Bioconjugate Chemistry · doi:10.1021/bc990168d · Cited by 163
Copper-Responsive Magnetic Resonance Imaging Contrast Agents
Que, E. L., Gianolio, E., Baker, S. L., Wong, A. P., Aime, S., & Chang, C. J. (2009) · Journal of the American Chemical Society · doi:10.1021/ja900884j · Cited by 162
Mechanistic Studies of a Calcium-Dependent MRI Contrast Agent
Li, W.-H., Parigi, G., Fragai, M., Luchinat, C., & Meade, T. J. (2002) · Inorganic Chemistry · doi:10.1021/ic0200390 · Cited by 159
Self-citationBimodal Fluorescence-Magnetic Resonance Contrast Agent for Apoptosis Imaging
Li, H., Parigi, G., Luchinat, C., & Meade, T. J. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.8b13376 · Cited by 150
Self-citationMolecular Magnetic Resonance Imaging Using a Redox-Active Iron Complex
Wang, H., Jordan, V. C., Ramsay, I. A., Sojoodi, M., Fuchs, B. C., Tanabe, K. K., Caravan, P. D., & Gale, E. M. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b00603 · Cited by 145
High Relaxivity Gd(III)–DNA Gold Nanostars: Investigation of Shape Effects on Proton Relaxation
Rotz, M. W., Culver, K. S. B., Parigi, G., MacRenaris, K. W., Luchinat, C., Odom, T. W., & Meade, T. J. (2015) · ACS Nano · doi:10.1021/nn5070953 · Cited by 132
Self-citationMonitoring ion-channel function in real time through quantum decoherence
Hall, L. T., Hill, C. D., Cole, J. H., Städler, B., Caruso, F., Mulvaney, P. A., Wrachtrup, J., & Hollenberg, L. C. L. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1002562107 · Cited by 129
Synthesis and Relaxometric Studies of a Dendrimer‐Based pH‐Responsive MRI Contrast Agent
Ali, M. M., Woods, M., Caravan, P. D., Opina, A. C. L., Spiller, M., Fettinger, J. C., & Sherry, A. D. (2008) · Chemistry - A European Journal · doi:10.1002/chem.200800402 · Cited by 120
Rodrı́guez, E., Nilges, M. J., Weissleder, R., & Chen, J. W. (2009) · Journal of the American Chemical Society · doi:10.1021/ja905274f · Cited by 116
What We Can Really Do with Bioresponsive MRI Contrast Agents
Angelovski, G. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201510956 · Cited by 115
New Dual Mode Gadolinium Nanoparticle Contrast Agent for Magnetic Resonance Imaging
Ghaghada, K. B., Ravoori, M. K., Sabapathy, D. G., Bankson, J. A., Kundra, V., & Annapragada, A. (2009) · PLoS ONE · doi:10.1371/journal.pone.0007628 · Cited by 114
Multimodal Magnetic‐Resonance/Optical‐Imaging Contrast Agent Sensitive to NADH
Tu, C., Nagao, R. J., & Louie, A. Y. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200900984 · Cited by 112
Advances in gadolinium-based MRI contrast agent designs for monitoring biological processes in vivo
Lux, J., & Sherry, A. D. (2018) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2018.04.006 · Cited by 104
Jordan, M. V. C., Lo, S., Chen, S., Preihs, C., Chirayil, S., Zhang, S., Kapur, P., Li, W.-H., Rodriguez, L. M. D. L., Lubag, A. J. M., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1609450113 · Cited by 102
DNA–gadolinium–gold nanoparticles for in vivo T1 MR imaging of transplanted human neural stem cells
Nicholls, F. J., Rotz, M. W., Ghuman, H., MacRenaris, K. W., Meade, T. J., & Modo, M. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.11.021 · Cited by 96
Self-citationSensing intracellular calcium ions using a manganese-based MRI contrast agent
Barandov, A., Bartelle, B. B., Williamson, C. G., Loucks, E. S., Lippard, S. J., & Jasanoff, A. (2019) · Nature Communications · doi:10.1038/s41467-019-08558-7 · Cited by 96
Eldredge-Hindy, H., Spiller, M., Chasse, J. M., et al. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000199293.86956.48 · Cited by 85
Supkowski, R. M., & Horrocks, W. D. (1999) · Inorganic Chemistry · doi:10.1021/ic990597n · Cited by 83
A EuII‐Containing Cryptate as a Redox Sensor in Magnetic Resonance Imaging of Living Tissue
Ekanger, L. A., Polin, L., Shen, Y., Haacke, E. M., Martin, P. D., & Allen, M. J. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201507227 · Cited by 82
Nejadnik, H., Ye, D., Lenkov, O. D., Donig, J., Martin, J. E., Castillo, R., Derugin, N., Sennino, B., Rao, J., & Daldrup-Link, H. E. (2015) · ACS Nano · doi:10.1021/nn504494c · Cited by 80
A Janus Chelator Enables Biochemically Responsive MRI Contrast with Exceptional Dynamic Range
Gale, E. M., Jones, C. M., Ramsay, I. A., Farrar, C. T., & Caravan, P. D. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b10898 · Cited by 80
Basal, L. A., Bailey, M. D., Romero, J., Ali, M. M., Kurenbekova, L., Yustein, J. T., Pautler, R. G., & Allen, M. J. (2017) · Chemical Science · doi:10.1039/c7sc03142d · Cited by 79
Gd(III)-Dithiolane Gold Nanoparticles for T1-Weighted Magnetic Resonance Imaging of the Pancreas
Holbrook, R. J., Rammohan, N., Rotz, M. W., MacRenaris, K. W., Preslar, A. T., & Meade, T. J. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b00599 · Cited by 78
Self-citationYou, Y., Tomat, E., Hwang, K., Atanasijevic, T., Nam, W., Jasanoff, A., & Lippard, S. J. (2010) · Chemical Communications · doi:10.1039/c0cc00179a · Cited by 74
Synthesis and visualization of a membrane-permeable MRI contrast agent
Allen, M. J., & Meade, T. J. (2003) · JBIC Journal of Biological Inorganic Chemistry · doi:10.1007/s00775-003-0475-2 · Cited by 71
Self-citationMolecular Magnetic Resonance Imaging of Tumor Response to Therapy
Shuhendler, A. J., Ye, D., Brewer, K. D., et al. (2015) · Scientific Reports · doi:10.1038/srep14759 · Cited by 70
Nanodiamond–Gadolinium(III) Aggregates for Tracking Cancer Growth In Vivo at High Field
Rammohan, N., MacRenaris, K. W., Moore, L. K., Parigi, G., Mastarone, D. J., Manus, L. M., Lilley, L. M., Preslar, A. T., Waters, E. A., Filicko, A., et al. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b03378 · Cited by 70
Self-citationMolecular Magnetic Resonance Imaging of Lung Fibrogenesis with an Oxyamine‐Based Probe
Waghorn, P. A., Jones, C. M., Rotile, N. J., Koerner, S. K., Ferreira, D. S., Chen, H. H., Probst, C. K., Tager, A. M., & Caravan, P. D. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201704773 · Cited by 70
Guenoun, J., Koning, G. A., Doeswijk, G. N., Bosman, L., Wielopolski, P. A., Krestin, G. P., & Bernsen, M. R. (2011) · Cell Transplantation · doi:10.3727/096368911x593118 · Cited by 68
Banerjee, S. R., Ngen, E. J., Rotz, M. W., Kakkad, S. M., Lisok, A., Pracitto, R., Pullambhatla, M., Chen, Z., Shah, T. K., Artemov, D., et al. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201503417 · Cited by 68
Self-citationGraphene Oxide Enhances Cellular Delivery of Hydrophilic Small Molecules by Co-incubation
Hung, A. H., Holbrook, R. J., Rotz, M. W., Glasscock, C. J., Mansukhani, N. D., MacRenaris, K. W., Manus, L. M., Duch, M. C., Dam, K. T., Hersam, M. C., et al. (2014) · ACS Nano · doi:10.1021/nn502986e · Cited by 65
Self-citationDual MRI-SPECT agent for pH-mapping
Gianolio, E., Maciocco, L., Imperio, D., Giovenzana, G. B., Simonelli, F., Abbas, K., Bisi, G., & Aime, S. (2010) · Chemical Communications · doi:10.1039/c0cc03554h · Cited by 64
Luo, J. H., Li, W., Xu, P., Zhang, L.-Y., & Chen, Z. (2012) · Inorganic Chemistry · doi:10.1021/ic301308z · Cited by 63
Ekanger, L. A., Mills, D. R., Ali, M. M., Polin, L., Shen, Y., Haacke, E. M., & Allen, M. J. (2016) · Inorganic Chemistry · doi:10.1021/acs.inorgchem.6b00629 · Cited by 63
Strategies for sensing neurotransmitters with responsive MRI contrast agents
Angelovski, G., & Tóth, É. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00154h · Cited by 51
Paetsch, I., Huber, M., Bornstedt, A., Schnackenburg, B., Boesiger, P., Stuber, M., Fleck, E., CAVAGNA, F. M., & Nagel, E. C. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20099 · Cited by 49
Anderson, C. E., Donnola, S. B., Jiang, Y., Batesole, J., Darrah, R. J., Drumm, M. L., Brady‐Kalnay, S. M., Steinmetz, N. F., Yu, X., Griswold, M. A., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-08762-9 · Cited by 38
Gd‐Aminoethyl‐DO3A Complexes: A Novel Class of pH‐Sensitive MRI Contrast Agents
Giovenzana, G. B., Negri, R., Rolla, G. A., & Tei, L. (2012) · European Journal of Inorganic Chemistry · doi:10.1002/ejic.201101296 · Cited by 37
Rammohan, N., Holbrook, R. J., Rotz, M. W., MacRenaris, K. W., Preslar, A. T., Carney, C. E., Reichova, V., & Meade, T. J. (2016) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.6b00389 · Cited by 31
Self-citationVistain, L. F., Rotz, M. W., Rathore, R., Preslar, A. T., & Meade, T. J. (2015) · Chemical Communications · doi:10.1039/c5cc06565h · Cited by 29
Self-citationVasculitis: Molecular Imaging by Targeting the Inflammatory Enzyme Myeloperoxidase
Su, H. S., Nahrendorf, M., Panizzi, P. R., et al. (2011) · Radiology · doi:10.1148/radiol.11110040 · Cited by 29
B22956/1, a New Intravascular Contrast Agent for MRI
Noce, A. L., Stoelben, S., Scheffler, K., et al. (2002) · Academic Radiology · doi:10.1016/s1076-6332(03)80245-3 · Cited by 28
Magnetic barcode imaging for contrast agents
Hung, A. H., Lilley, L. M., Hu, F., Harrison, V. S. R., & Meade, T. J. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26175 · Cited by 10
Self-citation
Research works printed but not linked: 41
- 10.1016/S0140-6736(84)92852-6 · doi:10.1016/s0140-6736(84)92852-6
- Helm L., 2013, ProQuest (Firm), The Chemistry of Contrast Agents in Medical Magnetic Resonance Imaging
- Weissleder R., 2009, ProQuest (Firm), Molecular Imaging Principles and Practice
- 10.1002/1521-3765(20010202)7:3<600::AID-CHEM600>3.0.CO;2-H · doi:10.1002/1521-3765(20010202)7:3<600::aid-chem600>3.0.co;2-h
- 10.1007/s10534-008-9135-x · doi:10.1007/s10534-008-9135-x
- 10.1063/1.1742867 · doi:10.1063/1.1742867
- 10.1007/s007750050158 · doi:10.1007/s007750050158
- 10.1007/PL00021449 · doi:10.1007/pl00021449
- 10.1021/ja017168k · doi:10.1021/ja017168k
- 10.1002/(SICI)1521-3773(19991102)38:21<3192::AID-ANIE3192>3.0.CO;2-# · doi:10.1002/(sici)1521-3773(19991102)38:21<3192::aid-anie3192>3.0.co;2-#
- 10.1021/ja048299z · doi:10.1021/ja048299z
- 10.1021/ic0702926 · doi:10.1021/ic0702926
- 10.1016/S1076-6332(03)80273-8 · doi:10.1016/s1076-6332(03)80273-8
- 10.1039/b100994j · doi:10.1039/b100994j
- 10.1073/pnas.1109649108 · doi:10.1073/pnas.1109649108
- 10.1021/jacs.8b07607 · DOI
- 10.3892/etm.2012.504 · doi:10.3892/etm.2012.504
- 10.1021/ac400973q · doi:10.1021/ac400973q
- 10.1097/00004728-199911001-00022 · doi:10.1097/00004728-199911001-00022
- Van Montfoort J. E., 1999, J. Pharmacol. Exp. Ther., 290, 153
- Leonhardt M., 2009, Drug Metab. Rev., 41, 24
- 10.1021/ja206134b · doi:10.1021/ja206134b
- 10.1021/ic700888w · doi:10.1021/ic700888w
- 10.1021/ja001797x · doi:10.1021/ja001797x
- 10.1021/ja0103647 · doi:10.1021/ja0103647
- 10.1039/b108294a · doi:10.1039/b108294a
- 10.1039/c3cc44116d · doi:10.1039/c3cc44116d
- 10.1039/b711989e · doi:10.1039/b711989e
- 10.1021/ja983702l · doi:10.1021/ja983702l
- 10.1039/B916931H · doi:10.1039/b916931h
- 10.1039/c2sc20273e · doi:10.1039/c2sc20273e
- 10.1021/acs.nanolett.8b05154 · doi:10.1021/acs.nanolett.8b05154
- 10.1016/j.chembiol.2004.03.003 · doi:10.1016/j.chembiol.2004.03.003
- 10.1021/bc9000454 · doi:10.1021/bc9000454
- 10.1016/j.biomaterials.2010.03.049 · doi:10.1016/j.biomaterials.2010.03.049
- 10.1002/mrm.22586 · doi:10.1002/mrm.22586
- 10.1002/ejic.201101336 · doi:10.1002/ejic.201101336
- 10.1148/radiol.2017170977 · doi:10.1148/radiol.2017170977
- 10.1371/journal.pone.0133921 · doi:10.1371/journal.pone.0133921
- 10.1021/acs.inorgchem.8b00120 · doi:10.1021/acs.inorgchem.8b00120
- 10.1021/acsnano.6b05030 · doi:10.1021/acsnano.6b05030
Cited by
Li, J., Zeng, H., Zeng, Z., Zeng, Y., & Xie, T. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.1c00875 · Cited by 257
Metadata
- Authors
- Li, H., & Meade, T. J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-10-08
- Volume
- 141
- Issue
- 43
- Pages
- 17025-17041
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2979481281
- Cited by
- 288
- References
- 81
- FWCI
- 8.86
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- Funders
- National Cancer Institute (P30CA060553)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.