Direct observation of kinesin stepping by optical trapping interferometry
The DOI matches its Crossref record; 52 of the 53 references it cites were found in a registry or an index.
Abstract
Do biological motors move with regular steps? To address this question, we constructed instrumentation with the spatial and temporal sensitivity to resolve movement on a molecular scale. We deposited silica beads carrying single molecules of the motor protein kinesin on microtubules using optical tweezers and analysed their motion under controlled loads by interferometry. We find that kinesin moves with 8-nm steps.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Optical-trapping assays for kinesin typically involve tracking and loading a bead attached to the C-terminus of the common stalk of the protein3 in place of its natural cargo. Because beads attached to the stalk tend to report the position of the molecule as a whole, the displacements generated by the two separate heads remain unresolved.”
From Direct observation of the binding state of the kinesin head to the microtubule (2009) · cites this paper as [3]
In the citing paper
“Cargo attached to the kinesin stalk moves processively in 8-nm increments3”
From Direct observation of the binding state of the kinesin head to the microtubule (2009) · cites this paper as [3]
In the citing paper
“Kinesin-1 is a motor protein that proceeds unidirectionally towards the plus end of the microtubule in discrete, 8.2-nm steps1 by alternately advancing each of its two heads, walking in an asymmetric, hand-over-hand fashion2–4.”
From A universal pathway for kinesin stepping (2011) · cites this paper as [1]
Citations
Cites
Observation of a single-beam gradient force optical trap for dielectric particles
Ashkin, A., Dziedzic, J. M., Bjorkholm, J. E., & Chu, S. (1986) · Optics Letters · doi:10.1364/ol.11.000288 · Cited by 7,030
Hart, M., & Deutsch, M. (1983) · Physics Bulletin · doi:10.1088/0031-9112/34/7/032 · Cited by 4,568
(2016) · Encyclopedia of Nanotechnology · doi:10.1007/978-94-017-9780-1_101037 · Cited by 3,780
(1995) · Springer eBooks · doi:10.1007/978-1-4419-1229-9 · Cited by 2,526
Huxley, H. E. (1969) · Science · doi:10.1126/science.164.3886.1356 · Cited by 1,959
Flexural rigidity of microtubules and actin filaments measured from thermal fluctuations in shape.
Gittes, F., Mickey, B., Nettleton, J., & Howard, J. (1993) · The Journal of cell biology · doi:10.1083/jcb.120.4.923 · Cited by 1,817
Low Reynolds number hydrodynamics: with special applications to particulate media
Happel, J., & Brenner, H. (1983) · Mechanics of fluids and transport processes · doi:10.1007/978-94-009-8352-6 · Cited by 1,354
Bead movement by single kinesin molecules studied with optical tweezers
Block, S. M., Goldstein, L. S. B., & Schnapp, B. J. (1990) · Nature · doi:10.1038/348348a0 · Cited by 1,038
Self-citationAshcroft, F. (1984) · Neuroscience · doi:10.1016/0306-4522(84)90114-3 · Cited by 982
Movement of microtubules by single kinesin molecules
Howard, J., Hudspeth, A. J., & Vale, R. D. (1989) · Nature · doi:10.1038/342154a0 · Cited by 885
Research works printed but not linked: 1
- Happel, J. & Brenner, H. Low Reynolds Number Hydrodynamics 322–331 (Kluwer Academic, Dordecht, 1991).
Cited by
Items 201–300 of 1,003
Sosa, H., Peterman, E. J. G., Moerner, W. E., & Goldstein, L. S. B. (2001) · Nature Structural Biology · doi:10.1038/88611 · Cited by 195
Single cytoplasmic dynein molecule movements: characterization and comparison with kinesin
Wang, Z., Khan, S., & Sheetz, M. P. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)80071-8 · Cited by 184
DNA transport by a micromachined Brownian ratchet device
Bader, J. S., Hammond, R. W., Henck, S. A., Deem, M. W., McDermott, G. A., Bustillo, J. M., Simpson, J. W., Mulhern, G. T., & Rothberg, J. M. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.23.13165 · Cited by 180
Highly processive microtubule-stimulated ATP hydrolysis by dimeric kinesin head domains
Hackney, D. D. (1995) · Nature · doi:10.1038/377448a0 · Cited by 177
Moving into the cell: single-molecule studies of molecular motors in complex environments
Veigel, C., & Schmidt, C. F. (2011) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm3062 · Cited by 176
“By contrast, the 'processive' motors, such as homodimeric Kinesin-1 (Ref”
BackgroundSelf-citationRotation of F1-ATPase: How an ATP-Driven Molecular Machine May Work
Kinosita, K., Adachi, K., & Itoh, H. (2004) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.33.110502.132716 · Cited by 178
““Give” (yielding under a high backward force) is a common phenomenon for linear molecular motors in an optical trap (33, 54).”
BackgroundTransport of Beads by Several Kinesin Motors
Beeg, J., Klumpp, S., Dimova, R., Gracià, R. S., Unger, E., & Lipowsky, R. (2008) · Biophysical Journal · doi:10.1529/biophysj.106.097881 · Cited by 178
“It has been shown that kinesin-1 moves in discrete 8-nm steps (7) hydrolyzing one molecule of ATP per step (8–10) and, more recently, that it moves in a hand-over-hand fashion (11–13).”
BackgroundMechanochemical coupling of two substeps in a single myosin V motor
Uemura, S., Higuchi, H., Olivares, A. O., De La Cruz, E. M., & Ishiwata, S. (2004) · Nature Structural & Molecular Biology · doi:10.1038/nsmb806 · Cited by 176
Long, D., Viovy, J.-L., & Ajdari, A. (1996) · Physical Review Letters · doi:10.1103/physrevlett.76.3858 · Cited by 175
Failure of a single-headed kinesin to track parallel to microtubule protofilaments
Berliner, E., Young, E. C., Anderson, K., Mahtani, H. K., & Gelles, J. (1995) · Nature · doi:10.1038/373718a0 · Cited by 173
Models of Motor-Assisted Transport of Intracellular Particles
Smith, D. A., & Simmons, R. M. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)75994-2 · Cited by 172
“Assays where a single motor molecule moves an attached bead (Svoboda et al., 1993) suggest that kinetic fluctuations in the number of motors bound to a filament should be less severe for highly processive motors such as kinesin or myosin V, where a single dimeric motor may stay within a zone of weak interaction around…”
BackgroundMicrotubule Assembly Dynamics at the Nanoscale
Schek, H. T., Gardner, M. K., Cheng, J., Odde, D. J., & Hunt, A. J. (2007) · Current Biology · doi:10.1016/j.cub.2007.07.011 · Cited by 176
“If the bead is held in a stationary trap as it is displaced by microtubule polymerization, some of the microtubule length change accumulates in the compliant biotin-streptavidin link between the bead and the microtubule; thus, changes in microtubule length are underestimated [18].”
Stretching and Transporting DNA Molecules Using Motor Proteins
Diez, S., Reuther, C., Dinu, C., Seidel, R., Mertig, M., Pompe, W., & Howard, J. (2003) · Nano Letters · doi:10.1021/nl034504h · Cited by 169
Steinberg, G., Peñalva, M. A., Riquelme, M., Wösten, H. A., & Harris, S. D. (2017) · Microbiology Spectrum · doi:10.1128/microbiolspec.funk-0034-2016 · Cited by 160
“Repeating cycles of ATP hydrolysis result in a sequence of ∼ 8-nm steps along the microtubule (168, 169).”
How kinesin waits between steps
Mori, T., Vale, R. D., & Tomishige, M. (2007) · Nature · doi:10.1038/nature06346 · Cited by 171
Femtonewton Force Spectroscopy of Single Extended DNA Molecules
Meiners, J.-C., & Quake, S. R. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.5014 · Cited by 171
Can Low-Level 50/60 Hz Electric and Magnetic Fields Cause Biological Effects?
Valberg, P. A., Kavet, R., & Rafferty, C. N. (1997) · Radiation Research · doi:10.2307/3579533 · Cited by 171
MAPPING CELL WALL POLYSACCHARIDES OF LIVING MICROBIAL CELLS USING ATOMIC FORCE MICROSCOPY
GAD, M., ITOH, A., & IKAI, A. (1997) · Cell Biology International · doi:10.1006/cbir.1997.0214 · Cited by 168
Direct observation of motor protein stepping in living cells using MINFLUX
Deguchi, T., Iwanski, M. K., Schentarra, E.-M., Heidebrecht, C., Schmidt, L., Heck, J., Weihs, T., Schnorrenberg, S., Hoess, P., Liu, S., et al. (2023) · Science · doi:10.1126/science.ade2676 · Cited by 167
“Over the past decades, the microtubule plus-end directed motor kinesin-1 has served as a key model both for the understanding of motor dynamics and for the development of improved single-molecule methods, such as optical tweezers and single particle tracking ( 4 – 7 ).”
BackgroundAminpour, M., Montemagno, C., & Tuszynski, J. A. (2019) · Molecules · doi:10.3390/molecules24091693 · Cited by 165
Creation of a three-dimensional optical chain for controllable particle delivery
Zhao, Y., Zhan, Q., Zhang, Y., & Li, Y.-P. (2005) · Optics Letters · doi:10.1364/ol.30.000848 · Cited by 163
The C-Terminus of Tubulin Increases Cytoplasmic Dynein and Kinesin Processivity
Wang, Z., & Sheetz, M. P. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76743-9 · Cited by 162
“…and have faithfully reported the run length of single motors on microtubules (processivity) (Block et al., 1990; Wang et al., 1995), the stepping distance (Coppin et al., 1996; Svoboda et al., 1993), and the tracking of motors along protofilaments (Gelles et al., 1988; Wang et al., 1995).”
BackgroundLarcher, J.-C., Boucher, D., Lazereg, S., Gros, F., & Denoulet, P. (1996) · Journal of Biological Chemistry · doi:10.1074/jbc.271.36.22117 · Cited by 164
Thermal noise limitations on micromechanical experiments
Gittes, F., & Schmidt, C. F. (1998) · European Biophysics Journal · doi:10.1007/s002490050113 · Cited by 162
Self-citationGeneralized Efficiency and its Application to Microscopic Engines
Derényi, I., Bier, M., & Astumian, R. D. (1999) · Physical Review Letters · doi:10.1103/physrevlett.83.903 · Cited by 161
Chilkoti, A., Boland, T., Ratner, B. D., & Stayton, P. S. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)80083-4 · Cited by 164
A cytoplasmic dynein tail mutation impairs motor processivity
Ori-McKenney, K. M., Xu, J., Gross, S. P., & Vallee, R. B. (2010) · Nature Cell Biology · doi:10.1038/ncb2127 · Cited by 165
“The fraction of beads bound to microtubules was used to assess the average number of available motors per bead: 50–100% binding fractions correspond to the few motor condition, whereas ≤ 30% binding fractions correspond to the single-motor rang”
BackgroundMultiple optical trapping and binding: new routes to self-assembly
Čižmár, T., Romero, L. C. D., Dholakia, K., & Andrews, D. L. (2010) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/0953-4075/43/10/102001 · Cited by 162
“A good example is the motion of kinesin upon microtubules (in ~8 nm steps) [40] the famous muscle contraction system: actin-myosin.”
BackgroundSelf-organized array of regularly spaced microbeads in a fiber-optical trap
Singer, W., Frick, M., Bernet, S., & Ritsch-Marte, M. (2003) · Journal of the Optical Society of America B · doi:10.1364/josab.20.001568 · Cited by 159
Electron spin resonance of nitrogen-vacancy centers in optically trapped nanodiamonds
Horowitz, V. R., Alemán, B. J., Christle, D. J., Cleland, A. N., & Awschalom, D. D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1211311109 · Cited by 160
“With ultrastable, dual-beam optical tweezers achieving repeatable displacements at the nanometer scale and below (27, 28), the prospect of combining optical tweezers with quantum-based sensors is particularly attractive for biosensing.”
BackgroundAutomated single-cell sorting system based on optical trapping
Grover, S. C., Skirtach, A. G., Gauthier, R. C., & Grover, C. P. (2001) · Journal of Biomedical Optics · doi:10.1117/1.1333676 · Cited by 160
Femtosecond optical tweezers for in-situ control of two-photon fluorescence
Agate, B., Brown, C. T. A., Sibbett, W., & Dholakia, K. (2004) · Optics Express · doi:10.1364/opex.12.003011 · Cited by 159
SINGLE-MOLECULE FLUORESCENCE SPECTROSCOPY AND MICROSCOPY OF BIOMOLECULAR MOTORS
Peterman, E. J. G., Sosa, H., & Moerner, W. E. (2004) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.55.091602.094340 · Cited by 157
Calibration of light forces in optical tweezers
Felgner, H., Müller, O., & Schliwa, M. (1995) · Applied Optics · doi:10.1364/ao.34.000977 · Cited by 156
Tracking Single Kinesin Molecules in the Cytoplasm of Mammalian Cells
Cai, D., Verhey, K. J., & Meyhöfer, E. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.100206 · Cited by 158
“KHC(1-891) was genetically tagged with a monomeric version of the fluorescent protein (FP) Citrine (mCit), a brighter and more photostable version of EYFP (18).”
BackgroundMethodInfluentialThree-dimensional position detection of optically trapped dielectric particles
Rohrbach, A., & Stelzer, E. H. K. (2002) · Journal of Applied Physics · doi:10.1063/1.1459748 · Cited by 160
Effect of spastic paraplegia mutations in KIF5A kinesin on transport activity
Ebbing, B., Mann, K., Starosta, A., Jaud, J., Schöls, L., Schüle, R., & Woehlke, G. (2008) · Human Molecular Genetics · doi:10.1093/hmg/ddn014 · Cited by 156
DICHOTOMOUS MARKOV NOISE: EXACT RESULTS FOR OUT-OF-EQUILIBRIUM SYSTEMS
BENA, I. (2006) · International Journal of Modern Physics B · doi:10.1142/s0217979206034881 · Cited by 174
“The literature on various model-realizations and applications is huge, and we cite here only a few references, [61, 85, 90, 92, 94, 95, 96, 97, 98, 99, 100, 101, 102, 103, 104, 105, 107], and also Ref.”
BackgroundThirteen Years of Single-Molecule Spectroscopy in Physical Chemistry and Biophysics
Moerner, W. E. (2001) · Springer series in chemical physics · doi:10.1007/978-3-642-56544-1_2 · Cited by 152
Role of the Kinesin Neck Region in Processive Microtubule-based Motility
Romberg, L., Pierce, D. W., & Vale, R. D. (1998) · The Journal of Cell Biology · doi:10.1083/jcb.140.6.1407 · Cited by 156
“Assuming a kinesin step size of 8 nm (the distance between tubulin dimers) (Svoboda et al., 1993), the wild-type protein takes 166 steps on average before detaching and has a release probability per step (Poff/ step) of 0.”
BackgroundMethodInfluentialKinesin and Dynein-Dynactin at Intersecting Microtubules: Motor Density Affects Dynein Function
Ross, J. L., Shuman, H., Holzbaur, E. L. F., & Goldman, Y. E. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.120014 · Cited by 159
Myosin V Walks by Lever Action and Brownian Motion
Shiroguchi, K., & Kinosita, K. (2007) · Science · doi:10.1126/science.1140468 · Cited by 152
Actin filament mechanics in the laser trap
Dupuis, D. E., Guilford, W. H., WU, J., & Warshaw, D. M. (1997) · Journal of Muscle Research and Cell Motility · doi:10.1023/a:1018672631256 · Cited by 152
“…motility at the molecular level has undergone a quantum leap due in large part to the development of the microneedle assay (Kishino & Yanagida, 1988; VanBuren et al., 1994) and the laser trap (Svoboda et al., 1993; Finer et al., 1994; Miyata et al., 1994; Molloy et al., 1995; Yin et al., 1995).”
BackgroundSynthetic Systems Powered by Biological Molecular Motors
Saper, G., & Hess, H. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00249 · Cited by 149
[38] Versatile optical traps with feedback control
Visscher, K. M., & Block, S. M. (1998) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(98)98040-5 · Cited by 169
Self-citationThe role of microtubule movement in bidirectional organelle transport
Kulić, I. M., Brown, A. E. X., Kim, H., Kural, C., Blehm, B., Selvin, P. R., Nelson, P. C., & Gelfand, V. I. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0800031105 · Cited by 154
Experimental Test of Connector Rotation during DNA Packaging into Bacteriophage φ29 Capsids
Hugel, T., Michaelis, J., Hetherington, C. L., Jardine, P. J., Grimes, S., Walter, J. M., Falk, W., Anderson, D. L., & Bustamante, C. (2007) · PLoS Biology · doi:10.1371/journal.pbio.0050059 · Cited by 149
“motors [20,21]; motors that move along DNA, like DNA”
Biomolecular motors at the intersection of nanotechnology and polymer science
Agarwal, A., & Hess, H. (2009) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.10.007 · Cited by 158
“These data helped unravel the walking mechanism of molecular motors [109-116].”
BackgroundReversible optical control of macroscopic polarization in ferroelectrics
Rubio‐Marcos, F., Ochoa, D. A., del Campo, A., García, M. Á., Castro, G. R., Fernández, J. F., & García, J. E. (2017) · Nature Photonics · doi:10.1038/s41566-017-0068-1 · Cited by 146
Trapping and tracking a local probe with a photonic force microscope
Rohrbach, A., Tischer, C., Neumayer, D., Florin, E., & Stelzer, E. H. K. (2004) · Review of Scientific Instruments · doi:10.1063/1.1753097 · Cited by 149
Nieto‐Vesperinas, M., Chaumet, P. C., & Rahmani, A. (2004) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2003.1343 · Cited by 145
“Later, gradient-force trapping of sub-wavelength metallic particles was reported (Svoboda et al. 1993).”
BackgroundSingle-Molecule Spectroscopy and Imaging of Biomolecules in Living Cells
Lord, S. J., Lee, H. D., & Moerner, W. E. (2010) · Analytical Chemistry · doi:10.1021/ac9024889 · Cited by 175
The effect of force on thermodynamics and kinetics of single molecule reactions
Tinoco, I., & Bustamante, C. (2002) · Biophysical Chemistry · doi:10.1016/s0301-4622(02)00177-1 · Cited by 171
Kinesin–microtubule binding depends on both nucleotide state and loading direction
Uemura, S., Kawaguchi, K., Yajima, J., Edamatsu, M., Toyoshima, Y. Y., & Ishiwata, S. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.092546199 · Cited by 143
Interrogation of Single Synthetic Polymer Chains and Polysaccharides by AFM‐Based Force Spectroscopy
Giannotti, M. I., & Vancso, G. J. (2007) · ChemPhysChem · doi:10.1002/cphc.200700175 · Cited by 163
Substeps within the 8-nm step of the ATPase cycle of single kinesin molecules
Nishiyama, M., Muto, E., Inoue, Y., Yanagida, T., & Higuchi, H. (2001) · Nature Cell Biology · doi:10.1038/35070116 · Cited by 162
Direct observation of intermediate states during the stepping motion of kinesin-1
Isojima, H., Iino, R., Niitani, Y., Noji, H., & Tomishige, M. (2016) · Nature Chemical Biology · doi:10.1038/nchembio.2028 · Cited by 154
Nanoscale Optical Trapping: A Review
Bradac, C. (2018) · Advanced Optical Materials · doi:10.1002/adom.201800005 · Cited by 158
Liedl, T., Sobey, T., & Simmel, F. (2007) · Nano Today · doi:10.1016/s1748-0132(07)70057-9 · Cited by 125
Controlling Kinesin by Reversible Disulfide Cross-Linking
Tomishige, M., & Vale, R. D. (2000) · The Journal of Cell Biology · doi:10.1083/jcb.151.5.1081 · Cited by 132
“Kinesin, a dimeric protein with two motor heads and a tail domain that docks onto a cargo, is a highly processive motor capable of taking z 150 steps of 8-nm length along a microtubule before dissociating (Howard et al., 1989; Block et al., 1990; Svoboda et al., 1993; Hackney, 1995; Vale et al., 1996; Gilbert et al.,…”
BackgroundOptical trapping and manipulation of micrometer and submicrometer particles
Daly, M., Sergides, M., & Chormaic, S. N. (2015) · Laser & Photonics Review · doi:10.1002/lpor.201500006 · Cited by 146
Molecular shuttles: directed motion of microtubules along nanoscale kinesin tracks
Dennis, J. R., Howard, J., & Viola Vogel, B. (1999) · Nanotechnology · doi:10.1088/0957-4484/10/3/302 · Cited by 153
“In the other assay, the kinesins are randomly immobilized on glass surfaces, and fluorescently labelled microtubules are observed under the light microscope to move in random paths across these surfaces.”
Stabilization of an optical microscope to 01 nm in three dimensions
Carter, A. R., King, G. M., Ulrich, T. A., Halsey, W. A., Alchenberger, D., & Perkins, T. T. (2007) · Applied Optics · doi:10.1364/ao.46.000421 · Cited by 142
Theory of Nonequilibrium Free Energy Transduction by Molecular Machines
Brown, A. I., & Sivak, D. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00254 · Cited by 162
Walking on two heads: the many talents of kinesin
Woehlke, G., & Schliwa, M. (2000) · Nature Reviews Molecular Cell Biology · doi:10.1038/35036069 · Cited by 177
Berry, R. M., & Berg, H. C. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.26.14433 · Cited by 139
Bao, Y., Luo, Z., & Cui, S. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00855a · Cited by 141
Nanoscale Inorganic Motors Driven by Light: Principles, Realizations, and Opportunities
Šípová, H., Andrén, D., Jones, S., & Käll, M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00401 · Cited by 137
Fast vesicle transport in PC12 neurites: velocities and forces
Hill, D. B., Plaza, M. J., Bonin, K., & Holzwarth, G. (2004) · European Biophysics Journal · doi:10.1007/s00249-004-0403-6 · Cited by 150
“The mechanochemistry of single kinesin molecules has been studied with great success by using an optical trap or glass fiber as a force sensor with piconewton sensitivity (Meyhoefer and Howard 1995; Svoboda et al. 1993; Vale et al. 1996; Visscher et al. 1999).”
BackgroundCapitanio, M., & Pavone, F. (2013) · Biophysical Journal · doi:10.1016/j.bpj.2013.08.007 · Cited by 127
“This configuration has been largely used to investigate processive molecular motors such as conventional kinesin (17), which can move continuously along a microtubule for up to several microns.”
BackgroundMethodSingle-molecule fluorescence resonance energy transfer in molecular biology
Sasmal, D. K., Pulido, L. E., Kasal, S., & Huang, J. (2016) · Nanoscale · doi:10.1039/c6nr06794h · Cited by 140
Torque–speed Relationship of the Na+-driven Flagellar Motor of Vibrio alginolyticus
Sowa, Y., Hotta, H., Homma, M., & Ishijima, A. (2003) · Journal of Molecular Biology · doi:10.1016/s0022-2836(03)00176-1 · Cited by 135
“This method has greatly advanced the studies of motor proteins that perform sliding movements, such as kinesin and myosin.(29) – 31 This bead assay has also been applied to studies of the flagellar motors.”
Hughes, M. L., & Dougan, L. (2016) · Reports on Progress in Physics · doi:10.1088/0034-4885/79/7/076601 · Cited by 157
“They have uncovered details of force generation in motor proteins [67, 68] and the importance of plasticity of hydrogen bond networks in regulating the mechanochemistry of cell adhesion complexes [69], cell signalling (mechanosensors) [70–72] and force generation [67, 68].”
Backgroundχ-Sequence recognition and DNA translocation by single RecBCD helicase/nuclease molecules
Dohoney, K. M., & Gelles, J. (2001) · Nature · doi:10.1038/35053124 · Cited by 141
“The opposite extreme is an enzyme like conventional kinesi”
BackgroundDetection of fractional steps in cargo movement by the collective operation of kinesin-1 motors
Leduc, C., Ruhnow, F., Howard, J., & Diez, S. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0701864104 · Cited by 138
Stochastic thermodynamics of single enzymes and molecular motors
Seifert, U. (2011) · The European Physical Journal E · doi:10.1140/epje/i2011-11026-7 · Cited by 133
Realization of optical pulling forces using chirality
Ding, K., Ng, J. T. F., Zhou, L., & Chan, C. T. (2014) · Physical Review A · doi:10.1103/physreva.89.063825 · Cited by 133
Robert, D., Nguyen, T.-H., Gallet, F., & Wilhelm, C. (2010) · PLoS ONE · doi:10.1371/journal.pone.0010046 · Cited by 140
“Regulation of intracellular trafficking is a central issue in cell biology. Extracellular material entering the cell is delivered to a series of vesicular compartments (endosomes), which move along microtubular tracks for intracellular processing. This directional transport is mediated by members of the kinesin and dy…”
BackgroundReversible switching of microtubule motility using thermoresponsive polymer surfaces.
Ionov, L., Stamm, M., & Diez, S. (2006) · Nano letters (Print) · doi:10.1021/nl0611539 · Cited by 125
Nucleotide-Dependent Single- to Double-Headed Binding of Kinesin
Kawaguchi, K., & Ishiwata, S. (2001) · Science · doi:10.1126/science.291.5504.667 · Cited by 132
Backsteps induced by nucleotide analogs suggest the front head of kinesin is gated by strain
Guydosh, N. R., & Block, S. M. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0600931103 · Cited by 132
Self-citationTarget-fueled DNA walker for highly selective miRNA detection
Wang, L., Deng, R., & Li, J. (2015) · Chemical Science · doi:10.1039/c5sc02784e · Cited by 132
Lauzon, A., Tyska, M. J., Rovner, A. S., Freyzon, Y., Warshaw, D. M., & Trybus, K. M. (1998) · Journal of Muscle Research and Cell Motility · doi:10.1023/a:1005489501357 · Cited by 132
“In addition, trap stiffness was determined from the Brownian motion of the microsphere by the equipartition method (Svoboda et al., 1993; Dupuis et al. 1997; Guilford et al., 1997).”
MethodOtt, W., Jobst, M. A., Schoeler, C., Gaub, H. E., & Nash, M. A. (2016) · Journal of Structural Biology · doi:10.1016/j.jsb.2016.02.011 · Cited by 135
Ito, S., Sugiyama, T., Toitani, N., Katayama, G., & Miyasaka, H. (2007) · The Journal of Physical Chemistry B · doi:10.1021/jp065156l · Cited by 131
Force spectroscopy on single passive biomolecules and single biomolecular bonds
Merkel, R. (2001) · Physics Reports · doi:10.1016/s0370-1573(00)00103-4 · Cited by 130
Towards the application of cytoskeletal motor proteins in molecular detection and diagnostic devices
Korten, T., Månsson, A., & Diez, S. (2010) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2010.05.001 · Cited by 141
Light forces the pace: optical manipulation for biophotonics
Stevenson, D. J., Gunn‐Moore, F. J., & Dholakia, K. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3475958 · Cited by 147
“steps that are still 8 nm; therefore, the hydrolysis of one ATP molecule is directly related to a single step.(81,83,85,86)”
BackgroundKinesin superfamily: roles in breast cancer, patient prognosis and therapeutics
Lucanus, A. J., & Yip, G. W. (2017) · Oncogene · doi:10.1038/onc.2017.406 · Cited by 136
Structural basis for power stroke vs. Brownian ratchet mechanisms of motor proteins
Hwang, W., & Karplus, M. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1818589116 · Cited by 132
Li, H., Rief, M., Oesterhelt, F., Gaub, H. E., Zhang, X., & Shen, J. (1999) · Chemical Physics Letters · doi:10.1016/s0009-2614(99)00389-9 · Cited by 131
Optical trapping of Rayleigh particles using a Gaussian standing wave
Zemánek, P., Jonáš, A., Šrámek, L., & Liška, M. (1998) · Optics Communications · doi:10.1016/s0030-4018(98)00093-5 · Cited by 129
Single Molecule Detection in Life Sciences
Ishii, Y., & Yanagida, T. (2000) · Single Molecules · doi:10.1002/(sici)1438-5171(200004)1:1<5::aid-simo5>3.0.co;2-a · Cited by 146
“[5] (C) A single two-headed kinesin molecule moving in one direction in a hand-over-hand fashion (top panel).”
BackgroundMethodLeibler, S. (1994) · Nature · doi:10.1038/370412a0 · Cited by 129
Coordination of molecular motors: from in vitro assays to intracellular dynamics
Holzbaur, E. L., & Goldman, Y. E. (2010) · Current Opinion in Cell Biology · doi:10.1016/j.ceb.2009.12.014 · Cited by 130
Biomolecular dynamics: order–disorder transitions and energy landscapes
Whitford, P. C., Sanbonmatsu, K. Y., & Onuchic, J. N. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/7/076601 · Cited by 137
Optical trapping in vivo : theory, practice, and applications
Favre‐Bulle, I. A., Stilgoe, A. B., Scott, E. K., & Rubinsztein-Dunlop, H. H. (2018) · Nanophotonics · doi:10.1515/nanoph-2019-0055 · Cited by 145
Optical traps for single molecule biophysics: a primer
Perkins, T. T. (2008) · Laser & Photonics Review · doi:10.1002/lpor.200810014 · Cited by 130
“Biological molecules, whether they are long DNA molecules [43] or proteins [40], are elastic.”
BackgroundMethodThe mechanisms of kinesin motor motility: lessons from the monomeric motor KIF1A
Hirokawa, N., Nitta, R., & Okada, Y. (2009) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2807 · Cited by 147
Construction and calibration of an optical trap on a fluorescence optical microscope
Lee, W. M., Reece, P. J., Marchington, R. F., Metzger, N. K., & Dholakia, K. (2007) · Nature Protocols · doi:10.1038/nprot.2007.446 · Cited by 126
Metadata
- Authors
- Svoboda, K., Schmidt, C. F., Schnapp, B. J., & Block, S. M.
- Affiliations
- Harvard University (US)
- Venue
- Nature
- Published
- 1993-10
- Volume
- 365
- Issue
- 6448
- Pages
- 721-727
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2152516404
- Cited by
- 1,910
- References
- 53
- Citations by year
- 2026: 31 · 2025: 33 · 2024: 31 · 2023: 40 · 2022: 38 · 2021: 50 · 2020: 49 · 2019: 59 · 2018: 69 · 2017: 62 · 2016: 61 · 2015: 69 · 2014: 53 · 2013: 54 · 2012: 92
- FWCI
- 18.99
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Cold Spring Harbor Laboratory Institutional Repository (Cold Spring Harbor Laboratory) (acceptedVersion)
- GRO (submittedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Microtubule and mitosis dynamics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Orbital Angular Momentum in Optics
- Keywords
- kinesin, molecular motors, step size, optical tweezers, interferometry, microtubules, silica beads
- MeSH terms
- Adenosine Triphosphate, Animals, Cattle, Interferometry, Lasers, Light, Microspheres, Microtubules, Movement, Silicon Dioxide, Kinesins, Decapodiformes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.