The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
A nanomaterial-based breath test for distinguishing gastric cancer from benign gastric conditions
Open accessAbstract
BACKGROUND: Upper digestive endoscopy with biopsy and histopathological evaluation of the biopsy material is the standard method for diagnosing gastric cancer (GC). However, this procedure may not be widely available for screening in the developing world, whereas in developed countries endoscopy is frequently used without major clinical gain. There is a high demand for a simple and non-invasive test for selecting the individuals at increased risk that should undergo the endoscopic examination. Here, we studied the feasibility of a nanomaterial-based breath test for identifying GC among patients with gastric complaints. METHODS: Alveolar exhaled breath samples from 130 patients with gastric complaints (37 GC/32 ulcers / 61 less severe conditions) that underwent endoscopy/biopsy were analyzed using nanomaterial-based sensors. Predictive models were built employing discriminant factor analysis (DFA) pattern recognition, and their stability against possible confounding factors (alcohol/tobacco consumption; Helicobacter pylori) was tested. Classification success was determined (i) using leave-one-out cross-validation and (ii) by randomly blinding 25% of the samples as a validation set. Complementary chemical analysis of the breath samples was performed using gas chromatography coupled with mass spectrometry. RESULTS: Three DFA models were developed that achieved excellent discrimination between the subpopulations: (i) GC vs benign gastric conditions, among all the patients (89% sensitivity; 90% specificity); (ii) early stage GC (I and II) vs late stage (III and IV), among GC patients (89% sensitivity; 94% specificity); and (iii) ulcer vs less severe, among benign conditions (84% sensitivity; 87% specificity). The models were insensitive against the tested confounding factors. Chemical analysis found that five volatile organic compounds (2-propenenitrile, 2-butoxy-ethanol, furfural, 6-methyl-5-hepten-2-one and isoprene) were significantly elevated in patients with GC and/or peptic ulcer, as compared with less severe gastric conditions. The concentrations both in the room air and in the breath samples were in the single p.p.b.v range, except in the case of isoprene. CONCLUSION: The preliminary results of this pilot study could open a new and promising avenue to diagnose GC and distinguish it from other gastric diseases. It should be noted that the applied methods are complementary and the potential marker compounds identified by gas-chromatography/mass spectrometry are not necessarily responsible for the differences in the sensor responses. Although this pilot study does not allow drawing far-reaching conclusions, the encouraging preliminary results presented here have initiated a large multicentre clinical trial to confirm the observed patterns for GC and benign gastric conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Individual Comparisons by Ranking Methods
Wilcoxon, F. (1945) · Biometrics Bulletin · doi:10.2307/3001968 · Cited by 15,354
Ullmann's Encyclopedia of Industrial Chemistry
(2012) · Choice Reviews Online · doi:10.5860/choice.50-1224 · Cited by 3,049
Ullmann's encyclopedia of industrial chemistry
Dunkin, I. R. (1989) · Reactive Polymers · doi:10.1016/0923-1137(89)90086-9 · Cited by 2,174
Epidemiology of gastric cancer
Crew, K. D., & Neugut, A. I. (2006) · World Journal of Gastroenterology · doi:10.3748/wjg.v12.i3.354 · Cited by 2,108
Recent cancer survival in Europe: a 2000–02 period analysis of EUROCARE-4 data
Verdecchia, A., Francisci, S., Brenner, H., Gatta, G., Micheli, A., Mangone, L., & Kunkler, I. (2007) · The Lancet Oncology · doi:10.1016/s1470-2045(07)70246-2 · Cited by 1,285
Diagnosing lung cancer in exhaled breath using gold nanoparticles
Peng, G., Tisch, U., Adams, O., Hakim, M., Shehada, N., Broza, Y. Y., Billan, S., Abdah-Bortnyak, R., Kuten, A., & Haick, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.235 · Cited by 1,263
Self-citationDiagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
Volatile Organic Compounds of Lung Cancer and Possible Biochemical Pathways
Hakim, M., Broza, Y. Y., Barash, O., Peled, N., Phillips, M., Amann, A., & Haick, H. (2012) · Chemical Reviews · doi:10.1021/cr300174a · Cited by 953 · cited 1×
“Therefore, it is important to consider the effect of inhaling exogenous compounds on the blood, as any change in the composition of blood can affect the body’s metabolism and, hence, the breath VOC profile (Hakim et al, 2012).”
BackgroundSelf-citationVolatile organic compounds in breath as markers of lung cancer: a cross-sectional study
Phillips, M., Gleeson, K., Hughes, J. M. B., Greenberg, J., Cataneo, R. N., Baker, L., & McVay, W. P. (1999) · The Lancet · doi:10.1016/s0140-6736(98)07552-7 · Cited by 918
Peng, G., Hakim, M., Broza, Y. Y., Billan, S., Abdah-Bortnyak, R., Kuten, A., Tisch, U., & Haick, H. (2010) · British Journal of Cancer · doi:10.1038/sj.bjc.6605810 · Cited by 775
Self-citation
Cited by
Carbon Nanotube Chemical Sensors
Schroeder, V., Savagatrup, S., He, M., Lin, S., & Swager, T. M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00340 · Cited by 1,131
Gold Nanoparticles in Diagnostics and Therapeutics for Human Cancer
Singh, P., Pandit, S., Mokkapati, V. R. S. S., Garg, A., Ravikumar, V., & Mijakovic, I. (2018) · International Journal of Molecular Sciences · doi:10.3390/ijms19071979 · Cited by 1,038
Amann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Assessment, origin, and implementation of breath volatile cancer markers
Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60329f · Cited by 644
Self-citationSensors for Breath Testing: From Nanomaterials to Comprehensive Disease Detection
Konvalina, G., & Haick, H. (2014) · Accounts of Chemical Research · doi:10.1021/ar400070m · Cited by 561
Self-citationSensors for Volatile Organic Compounds
Khatib, M., & Haick, H. (2022) · ACS Nano · doi:10.1021/acsnano.1c10827 · Cited by 533
Self-citationFlexible Sensors Based on Nanoparticles
Segev-Bar, M., & Haick, H. (2013) · ACS Nano · doi:10.1021/nn402728g · Cited by 511
Self-citationNakhleh, M. K., Amal, H., Jeries, R., Broza, Y. Y., Aboud, M., Gharra, A., Ivgi, H., Khatib, S., Badarneh, S., Har-Shai, L., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b04930 · Cited by 510
Self-citationA Review of Clinical Translation of Inorganic Nanoparticles
Anselmo, A. C., & Mitragotri, S. (2015) · The AAPS Journal · doi:10.1208/s12248-015-9780-2 · Cited by 509
Self‐Powered Respiration Monitoring Enabled By a Triboelectric Nanogenerator
Su, Y., Chen, G., Chen, C., Gong, Q., Xie, G., Yao, M., Tai, H., Jiang, Y., & Chen, J. (2021) · Advanced Materials · doi:10.1002/adma.202101262 · Cited by 481
Review—Non-Invasive Monitoring of Human Health by Exhaled Breath Analysis: A Comprehensive Review
Das, S., & Pal, M. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab67a6 · Cited by 466
Broza, Y. Y., Zhou, X., Yuan, M., Qu, D., Zheng, Y., Vishinkin, R., Khatib, M., Wu, W., & Haick, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00437 · Cited by 461
Self-citationGastric cancer: Prevention, screening and early diagnosis
Pasechnikov, V. (2014) · World Journal of Gastroenterology · doi:10.3748/wjg.v20.i38.13842 · Cited by 436
Electronic Noses: From Advanced Materials to Sensors Aided with Data Processing
Hu, W., Wan, L., Jian, Y., Ren, C., Jin, K., Su, X., Bai, X., Haick, H., Yao, M., & Wu, W. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201800488 · Cited by 366
Self-citationSolid-state gas sensors for breath analysis: A review
Di Natale, C., Paolesse, R., Martinelli, E., & Capuano, R. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.03.014 · Cited by 365
Nanomaterial-Based Sensors for Detection of Disease by Volatile Organic Compounds
Broza, Y. Y., & Haick, H. (2013) · Nanomedicine · doi:10.2217/nnm.13.64 · Cited by 358
Self-citationBreath Analysis as a Potential and Non-Invasive Frontier in Disease Diagnosis: An Overview
Pereira, J., Porto-Figueira, P., Cavaco, C., Taunk, K., Rapole, S., Dhakne, R., Nagarajaram, H., & Câmara, J. (2015) · Metabolites · doi:10.3390/metabo5010003 · Cited by 301
Chen, Y., Zhang, Y., Pan, F., Liu, J., Wang, K., Zhang, C., Cheng, S., Lu, L., Zhang, W., Zhang, Z., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b01441 · Cited by 298
Exhaled breath analysis: a review of ‘breath-taking’ methods for off-line analysis
Lawal, O., Ahmed, W. M., Nijsen, T. M. E., Goodacre, R., & Fowler, S. J. (2017) · Metabolomics · doi:10.1007/s11306-017-1241-8 · Cited by 288
Synergy between nanomaterials and volatile organic compounds for non-invasive medical evaluation
Broza, Y. Y., Vishinkin, R., Barash, O., Nakhleh, M. K., & Haick, H. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00317c · Cited by 276
Self-citationShehada, N., Brönstrup, G., Funka, K., Christiansen, S., Leja, M., & Haick, H. (2015) · Nano Letters · doi:10.1021/nl504482t · Cited by 255
Artificial sensing intelligence with silicon nanowires for ultraselective detection in the gas phase
Wang, B., Cancilla, J. C., Torrecilla, J. S., & Haick, H. (2014) · Nano Letters · doi:10.1021/nl404335p · Cited by 236
Self-citationSilicon Nanowire Sensors Enable Diagnosis of Patients via Exhaled Breath
Shehada, N., Cancilla, J. C., Torrecilla, J. S., Pariente, E. S., Brönstrup, G., Christiansen, S., Johnson, D. W., Leja, M., Davies, M. P. A., Liran, O., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b03127 · Cited by 227
Self-citationBreath VOC analysis and machine learning approaches for disease screening: a review
P, H., Rangarajan, M., & Pandya, H. J. (2023) · Journal of Breath Research · doi:10.1088/1752-7163/acb283 · Cited by 37
Metadata
- Authors
- Xu, Z.-Q., Broza, Y. Y., Ionsecu, R., Tisch, U., Ding, L., Liu, H., Song, Q., Pan, Y.-Y., Xiong, F.-X., Gu, K.-S., Sun, G.-P., Chen, Z.-D., Leja, M., & Haick, H.
- Venue
- British Journal of Cancer
- Published
- 2013-03
- Volume
- 108
- Issue
- 4
- Pages
- 941-950
- ISSN
- 0007-0920 (ISSN-L)
- 1532-1827
- OpenAlex
- W2138581372
- Cited by
- 271
- References
- 43
- FWCI
- 13.99
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.