The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Integrated barcode chips for rapid, multiplexed analysis of proteins in microliter quantities of blood
Open accessAbstract
As the tissue that contains the largest representation of the human proteome, blood is the most important fluid for clinical diagnostics. However, although changes of plasma protein profiles reflect physiological or pathological conditions associated with many human diseases, only a handful of plasma proteins are routinely used in clinical tests. Reasons for this include the intrinsic complexity of the plasma proteome, the heterogeneity of human diseases and the rapid degradation of proteins in sampled blood. We report an integrated microfluidic system, the integrated blood barcode chip that can sensitively sample a large panel of protein biomarkers over broad concentration ranges and within 10 min of sample collection. It enables on-chip blood separation and rapid measurement of a panel of plasma proteins from quantities of whole blood as small as those obtained by a finger prick. Our device holds potential for inexpensive, noninvasive and informative clinical diagnoses, particularly in point-of-care settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cluster analysis and display of genome-wide expression patterns
Eisen, M. B., Spellman, P. T., Brown, P. O., & Botstein, D. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.25.14863 · Cited by 16,184
Coussens, L. M., & Werb, Z. (2002) · Nature · doi:10.1038/nature01322 · Cited by 15,111
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
A cytokine-mediated link between innate immunity, inflammation, and cancer
Lin, W.-W., & Karin, M. (2007) · Journal of Clinical Investigation · doi:10.1172/jci31537 · Cited by 1,940 · cited 1×
“3a ), the prostate cancer marker PSA and eleven proteins secreted by various white blood cells, have been associated with tumor microenvironment formation, tumor progression and tumor metastasi”
BackgroundMicrofluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Continuous Particle Separation Through Deterministic Lateral Displacement
Huang, L. R., Cox, E. C., Austin, R. H., & Sturm, J. C. (2004) · Science · doi:10.1126/science.1094567 · Cited by 1,634
Inflammation in prostate carcinogenesis
De Marzo, A. M., Platz, E. A., Sutcliffe, S., Xu, J., Grönberg, H., Drake, C. G., Nakai, Y., Isaacs, W. B., & Nelson, W. G. (2007) · Nature Reviews Cancer · doi:10.1038/nrc2090 · Cited by 1,621
From Micro- to Nanofabrication with Soft Materials
Quake, S. R., & Scherer, A. (2000) · Science · doi:10.1126/science.290.5496.1536 · Cited by 1,131
Serum Cytokine Levels in Human Septic Shock
Pinsky, M. R., Vincent, J.-L., Deviere, J., Alegre, M., Kahn, R. J., & Dupont, E. (1993) · Chest · doi:10.1378/chest.103.2.565 · Cited by 884
Microfluidic Digital PCR Enables Multigene Analysis of Individual Environmental Bacteria
Ottesen, E. A., Hong, J. W., Quake, S. R., & Leadbetter, J. R. (2006) · Science · doi:10.1126/science.1131370 · Cited by 737
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Multiplexed protein profiling on microarrays by rolling-circle amplification
Schweitzer, B., Roberts, S., Grimwade, B., Shao, W., Wang, M., Fu, Q., Shu, Q., Laroche, I., Zhou, Z., Tchernev, V. T., et al. (2002) · Nature Biotechnology · doi:10.1038/nbt0402-359 · Cited by 573
Counting Low-Copy Number Proteins in a Single Cell
Huang, B., Wu, H., Bhaya, D., Grossman, A., Granier, S., Kobilka, B. K., & Zare, R. N. (2007) · Science · doi:10.1126/science.1133992 · Cited by 387
Heath, J. R., & Davis, M. E. (2008) · Annual Review of Medicine · doi:10.1146/annurev.med.59.061506.185523 · Cited by 354
Self-citationBailey, R. C., Kwong, G. A., Radu, C. G., Witte, O. N., & Heath, J. R. (2007) · Journal of the American Chemical Society · doi:10.1021/ja065930i · Cited by 272
Self-citationMultiplexed Immunobead-Based Cytokine Profiling for Early Detection of Ovarian Cancer
Gorelik, E., Landsittel, D. P., Marrangoni, A. M., Modugno, F., Velikokhatnaya, L., Winans, M. T., Bigbee, W. L., Herberman, R. B., & Lokshin, A. E. (2005) · Cancer Epidemiology, Biomarkers & Prevention · doi:10.1158/1055-9965.epi-04-0404 · Cited by 264
Hsieh, S., Chen, R., Pan, Y., & Lee, H. (2006) · PROTEOMICS · doi:10.1002/pmic.200500535 · Cited by 233
Serum levels of interleukins, growth factors and angiogenin in patients with endometrial cancer
Chopra, V., Ding, T. V., & Hanningan, E. V. (1997) · Journal of Cancer Research and Clinical Oncology · doi:10.1007/bf01214669 · Cited by 117
Chen, J., Chang, Y., Yao, C., Chiueh, T., Huang, S., Chien, K.-Y., Chen, A., Chang, F., Wong, C., & Chen, Y. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0407992101 · Cited by 108
Lambeck, A. J. A., Crijns, A. P. G., Leffers, N., Sluiter, W. J., ten Hoor, K. A., Braid, M., van der Zee, A. G. J., Daemen, T., Nijman, H. W., & Kast, W. M. (2007) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-06-1828 · Cited by 101
Functional devices from DNA and proteins
Niemeyer, C. M. (2007) · Nano Today · doi:10.1016/s1748-0132(07)70058-0 · Cited by 100
RATIONING AND OTHER PERILS FOR PROVIDERS AND CONSUMERS
Silver, G. (1989) · The Lancet · doi:10.1016/s0140-6736(89)93013-4 · Cited by 88
Clinical‐scale high‐throughput human plasma proteome analysis: Lung adenocarcinoma
Fujii, K., Nakano, T., Kanazawa, M., Akimoto, S., Hirano, T., Kato, H., & Nishimura, T. (2005) · PROTEOMICS · doi:10.1002/pmic.200401145 · Cited by 55
HISTORY, CHARACTER, AND DIAGNOSTIC PROSPECTS*
Anderson, N. L., & Anderson, N. G. (2002) · Cited by 26
Öncül, O., Top, C., & Çavuþlu, Þ. (2002) · Diabetes Care · doi:10.2337/diacare.25.5.937 · Cited by 15
Cited by
Rissin, D. M., Kan, C. W., Campbell, T. G., Howes, S. C., Fournier, D. R., Song, L., Piech, T., Patel, P. P., Chang, L., Rivnak, A. J., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1641 · Cited by 2,119
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Treating metastatic cancer with nanotechnology
Schroeder, A., Heller, D. A., Winslow, M. M., Dahlman, J. E., Pratt, G. W., Langer, R., Jacks, T., & Anderson, D. G. (2012) · Nature Reviews Cancer · doi:10.1038/nrc3180 · Cited by 1,159
Comparative advantages of mechanical biosensors
Arlett, J. L., Myers, E. B., & Roukes, M. L. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.44 · Cited by 966
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Metadata
- Authors
- Fan, R., Vermesh, O., Srivastava, A., Yen, B. K. H., Qin, L., Ahmad, H., Kwong, G. A., Liu, C.-C., Gould, J., Hood, L., & Heath, J. R.
- Venue
- Nature Biotechnology
- Published
- 2008-11-16
- Volume
- 26
- Issue
- 12
- Pages
- 1373-1378
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W2088298294
- Cited by
- 539
- References
- 26
- FWCI
- 25.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.