The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Integrated barcode chips for rapid, multiplexed analysis of proteins in microliter quantities of blood
Open accessAbstract
As the tissue that contains the largest representation of the human proteome, blood is the most important fluid for clinical diagnostics. However, although changes of plasma protein profiles reflect physiological or pathological conditions associated with many human diseases, only a handful of plasma proteins are routinely used in clinical tests. Reasons for this include the intrinsic complexity of the plasma proteome, the heterogeneity of human diseases and the rapid degradation of proteins in sampled blood. We report an integrated microfluidic system, the integrated blood barcode chip that can sensitively sample a large panel of protein biomarkers over broad concentration ranges and within 10 min of sample collection. It enables on-chip blood separation and rapid measurement of a panel of plasma proteins from quantities of whole blood as small as those obtained by a finger prick. Our device holds potential for inexpensive, noninvasive and informative clinical diagnoses, particularly in point-of-care settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cluster analysis and display of genome-wide expression patterns
Eisen, M. B., Spellman, P. T., Brown, P. O., & Botstein, D. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.25.14863 · Cited by 16,184
Coussens, L. M., & Werb, Z. (2002) · Nature · doi:10.1038/nature01322 · Cited by 15,111
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
A cytokine-mediated link between innate immunity, inflammation, and cancer
Lin, W.-W., & Karin, M. (2007) · Journal of Clinical Investigation · doi:10.1172/jci31537 · Cited by 1,940 · cited 1×
“3a ), the prostate cancer marker PSA and eleven proteins secreted by various white blood cells, have been associated with tumor microenvironment formation, tumor progression and tumor metastasi”
BackgroundMicrofluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Continuous Particle Separation Through Deterministic Lateral Displacement
Huang, L. R., Cox, E. C., Austin, R. H., & Sturm, J. C. (2004) · Science · doi:10.1126/science.1094567 · Cited by 1,634
Inflammation in prostate carcinogenesis
De Marzo, A. M., Platz, E. A., Sutcliffe, S., Xu, J., Grönberg, H., Drake, C. G., Nakai, Y., Isaacs, W. B., & Nelson, W. G. (2007) · Nature Reviews Cancer · doi:10.1038/nrc2090 · Cited by 1,621
From Micro- to Nanofabrication with Soft Materials
Quake, S. R., & Scherer, A. (2000) · Science · doi:10.1126/science.290.5496.1536 · Cited by 1,131
Serum Cytokine Levels in Human Septic Shock
Pinsky, M. R., Vincent, J.-L., Deviere, J., Alegre, M., Kahn, R. J., & Dupont, E. (1993) · Chest · doi:10.1378/chest.103.2.565 · Cited by 884
Cited by
Rissin, D. M., Kan, C. W., Campbell, T. G., Howes, S. C., Fournier, D. R., Song, L., Piech, T., Patel, P. P., Chang, L., Rivnak, A. J., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1641 · Cited by 2,119
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Treating metastatic cancer with nanotechnology
Schroeder, A., Heller, D. A., Winslow, M. M., Dahlman, J. E., Pratt, G. W., Langer, R., Jacks, T., & Anderson, D. G. (2012) · Nature Reviews Cancer · doi:10.1038/nrc3180 · Cited by 1,159
Comparative advantages of mechanical biosensors
Arlett, J. L., Myers, E. B., & Roukes, M. L. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.44 · Cited by 966
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Plasmonic ELISA for the ultrasensitive detection of disease biomarkers with the naked eye
de la Rica, R., & Stevens, M. M. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.186 · Cited by 873
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Single cell analysis: the new frontier in ‘omics’
Wang, D., & Bodovitz, S. (2010) · Trends in Biotechnology · doi:10.1016/j.tibtech.2010.03.002 · Cited by 673
SERS-Activated Platforms for Immunoassay: Probes, Encoding Methods, and Applications
Wang, Z., Zong, S., Wu, L., Zhu, D., & Cui, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00027 · Cited by 614
Label-free biomarker detection from whole blood
Stern, E., Vacic, A., Rajan, N. K., Criscione, J. M., Park, J., Ilic, B. R., Mooney, D. J., Reed, M. A., & Fahmy, T. M. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2009.353 · Cited by 543
Continuous separation of cells and particles in microfluidic systems
Lenshof, A., & Laurell, T. (2010) · Chemical Society Reviews · doi:10.1039/b915999c · Cited by 528
Microfluidic Chips for Point‐of‐Care Immunodiagnostics
Gervais, L., de Rooij, N., & Delamarche, E. (2011) · Advanced Materials · doi:10.1002/adma.201100464 · Cited by 491
Ma, C., Fan, R., Ahmad, H., Shi, Q., Comin-Anduix, B., Chodon, T., Koya, R. C., Liu, C.-C., Kwong, G. A., Radu, C. G., et al. (2011) · Nature Medicine · doi:10.1038/nm.2375 · Cited by 441
Self-citationPlasmonic nanosensors with inverse sensitivity by means of enzyme-guided crystal growth
Rodríguez-Lorenzo, L., de la Rica, R., Álvarez-Puebla, R. A., Liz-Marzán, L. M., & Stevens, M. M. (2012) · Nature Materials · doi:10.1038/nmat3337 · Cited by 443
Advances and challenges in biosensor-based diagnosis of infectious diseases
Sin, M. L., Mach, K. E., Wong, P. K., & Liao, J. C. (2014) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.2014.888313 · Cited by 435
Latest Developments in Micro Total Analysis Systems
Arora, A., Simone, G., Salieb-Beugelaar, G. B., Kim, J. T., & Manz, A. (2010) · Analytical Chemistry · doi:10.1021/ac100969k · Cited by 421
Hang, Y., Boryczka, J., & Wu, N. (2022) · Chemical Society Reviews · doi:10.1039/c9cs00621d · Cited by 377
High-sensitivity nanosensors for biomarker detection
Swierczewska, M., Liu, G., Lee, S., & Chen, X. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15238f · Cited by 361
Microfluidics for medical diagnostics and biosensors
Rivet, C., Lee, H., Hirsch, A., Hamilton, S., & Lu, H. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.08.015 · Cited by 356
Du, W., Li, L., Nichols, K. P., & Ismagilov, R. F. (2009) · Lab on a Chip · doi:10.1039/b908978k · Cited by 351
Simple, distance-based measurement for paper analytical devices
Cate, D. M., Dungchai, W., Cunningham, J. C., Volckens, J., & Henry, C. S. (2013) · Lab on a Chip · doi:10.1039/c3lc50072a · Cited by 348
Self-powered integrated microfluidic point-of-care low-cost enabling (SIMPLE) chip
Yeh, E.-C., Fu, C.-C., Hu, L., Thakur, R., Feng, J., & Lee, L. P. (2017) · Science Advances · doi:10.1126/sciadv.1501645 · Cited by 347
Immunoassays in microfluidic systems
Ng, A. H. C., Uddayasankar, U., & Wheeler, A. R. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3678-8 · Cited by 345
Stability of DNA Origami Nanoarrays in Cell Lysate
Mei, Q., Wei, X., Su, F., Liu, Y., Youngbull, C., Johnson, R., Lindsay, S., Yan, H., & Meldrum, D. (2011) · Nano Letters · doi:10.1021/nl1040836 · Cited by 338
Scaling by shrinking: empowering single-cell 'omics' with microfluidic devices
Prakadan, S. M., Shalek, A. K., & Weitz, D. A. (2017) · Nature Reviews Genetics · doi:10.1038/nrg.2017.15 · Cited by 325
Digital microfluidics: a versatile tool for applications in chemistry, biology and medicine
Jebrail, M. J., Bartsch, M. S., & Patel, K. D. (2012) · Lab on a Chip · doi:10.1039/c2lc40318h · Cited by 324
Aptamer-Based Electrochemical Biosensor for Interferon Gamma Detection
Liu, Y., Tuleouva, N., Ramanculov, E., & Revzin, A. (2010) · Analytical Chemistry · doi:10.1021/ac101409t · Cited by 324
Single-cell proteomic chip for profiling intracellular signaling pathways in single tumor cells
Shi, Q., Qin, L., Wei, W., Geng, F., Fan, R., Shik Shin, Y., Guo, D., Hood, L., Mischel, P. S., & Heath, J. R. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1110865109 · Cited by 318
Self-citationKleppe, M., Kwak, M., Koppikar, P., Riester, M., Keller, M., Bastian, L., Hricik, T., Bhagwat, N., McKenney, A. S., Papalexi, E., et al. (2015) · Cancer Discovery · doi:10.1158/2159-8290.cd-14-0736 · Cited by 315
Self-citationRapid and Fully Microfluidic Ebola Virus Detection with CRISPR-Cas13a
Qin, P., Park, M., Alfson, K. J., Tamhankar, M., Carrion, R., Patterson, J. L., Griffiths, A., He, Q., Yildiz, A., Mathies, R., et al. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00239 · Cited by 311
Hou, H. W., Bhagat, A. A. S., Lin Chong, A. G., Mao, P., Wei Tan, K. S., Han, J., & Lim, C. T. (2010) · Lab on a Chip · doi:10.1039/c003873c · Cited by 300
Lu, Y., Xue, Q., Eisele, M. R., Sulistijo, E. S., Brower, K., Han, L., Amir, E.-A. D., Pe’er, D., Miller-Jensen, K., & Fan, R. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1416756112 · Cited by 264
Self-citationvan Reenen, A., de Jong, A. M., den Toonder, J. M. J., & Prins, M. W. J. (2014) · Lab Chip · doi:10.1039/c3lc51454d · Cited by 262
Lab-on-chip technology for chronic disease diagnosis
Wu, J., Dong, M., Rigatto, C., Liu, Y., & Lin, F. (2018) · npj Digital Medicine · doi:10.1038/s41746-017-0014-0 · Cited by 170
Nanotechnology: emerging tools for biology and medicine
Wong, I. Y., Bhatia, S. N., & Toner, M. (2013) · Genes & Development · doi:10.1101/gad.226837.113 · Cited by 132
Multivalent ions induce lateral structural inhomogeneities in polyelectrolyte brushes
Yu, J., Jackson, N. E., Xu, X., Brettmann, B. K., Ruths, M., de Pablo, J. J., & Tirrell, M. (2017) · Science Advances · doi:10.1126/sciadv.aao1497 · Cited by 127
“Polyelectrolyte brushes are of particular interest because they can regulate transport of ions and molecules (1, 2); control wettability, adhesion, and lubrication of surfaces (3, 4); or convert chemical and biochemical stimuli into optical (5), electrical (6), and mechanical signals (7).”
BackgroundEmerging affinity-based techniques in proteomics
Xie, S., Moya, C., Bilgin, B., Jayaraman, A., & Walton, S. P. (2009) · Expert Review of Proteomics · doi:10.1586/epr.09.74 · Cited by 38
Chen, W., Huang, N.-T., Li, X., Yu, Z. T. F., Kurabayashi, K., & Fu, J. (2013) · Frontiers in Oncology · doi:10.3389/fonc.2013.00098 · Cited by 31
Metadata
- Authors
- Fan, R., Vermesh, O., Srivastava, A., Yen, B. K. H., Qin, L., Ahmad, H., Kwong, G. A., Liu, C.-C., Gould, J., Hood, L., & Heath, J. R.
- Venue
- Nature Biotechnology
- Published
- 2008-11-16
- Volume
- 26
- Issue
- 12
- Pages
- 1373-1378
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W2088298294
- Cited by
- 539
- References
- 26
- FWCI
- 25.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.