Using personal glucose meters and functional DNA sensors to quantify a variety of analytical targets
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Portable, low-cost and quantitative detection of a broad range of targets at home and in the field has the potential to revolutionize medical diagnostics and environmental monitoring. Despite many years of research, very few such devices are commercially available. Taking advantage of the wide availability and low cost of the pocket-sized personal glucose meter—used worldwide by diabetes sufferers—we demonstrate a method to use such meters to quantify non-glucose targets, ranging from a recreational drug (cocaine, 3.4 μM detection limit) to an important biological cofactor (adenosine, 18 μM detection limit), to a disease marker (interferon-gamma of tuberculosis, 2.6 nM detection limit) and a toxic metal ion (uranium, 9.1 nM detection limit). The method is based on the target-induced release of invertase from a functional-DNA–invertase conjugate. The released invertase converts sucrose into glucose, which is detectable using the meter. The approach should be easily applicable to the detection of many other targets through the use of suitable functional-DNA partners (aptamers DNAzymes or aptazymes).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuerk, C., & Gold, L. (1990) · Science · doi:10.1126/science.2200121 · Cited by 10,405
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Simultaneous phase and size control of upconversion nanocrystals through lanthanide doping
Wang, F., Han, Y., Lim, C. S., Lu, Y., Wang, J., Xu, J., Chen, H., Zhang, C., Hong, M., & Liu, X. (2010) · Nature · doi:10.1038/nature08777 · Cited by 3,151
Self-citationCELLULAR RESPONSES TO INTERFERON-γ
Boehm, U., Klamp, T., Groot, M., & Howard, J. C. (1997) · Annual Review of Immunology · doi:10.1146/annurev.immunol.15.1.749 · Cited by 2,890 · cited 1×
“IFN-γ is a cytokine released by the human immune system, and abnormal levels of IFN-γ are related to many infectious disease and pathogen-directed responses of the human bod”
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
The Fluorescent Toolbox for Assessing Protein Location and Function
Giepmans, B. N. G., Adams, S. R., Ellisman, M. H., & Tsien, R. Y. (2006) · Science · doi:10.1126/science.1124618 · Cited by 2,770
Functional Nucleic Acid Sensors
Liu, J., Cao, Z., & Lu, Y. (2009) · Chemical Reviews · doi:10.1021/cr030183i · Cited by 2,187
Self-citationCreating new fluorescent probes for cell biology
Zhang, J., Campbell, R. E., Ting, A. Y., & Tsien, R. Y. (2002) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm976 · Cited by 1,981
Breaker, R. R., & Joyce, G. F. (1994) · Chemistry & Biology · doi:10.1016/1074-5521(94)90014-0 · Cited by 1,476
Song, S., Wang, L., Li, J., Fan, C., & Zhao, J. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2007.12.004 · Cited by 1,434
Cited by
Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules
Labib, M., Sargent, E. H., & Kelley, S. O. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00220 · Cited by 976
Swan, M. (2012) · Journal of Sensor and Actuator Networks · doi:10.3390/jsan1030217 · Cited by 934
Zhou, W., Saran, R., & Liu, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00063 · Cited by 931
Gold Nanoparticles for In Vitro Diagnostics
Zhou, W., Gao, X., Liu, D., & Chen, X. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00100 · Cited by 901
Device integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
Xiong, Y., Zhang, J., Yang, Z., Mou, Q., Ma, Y., Xiong, Y., & Lu, Y. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.9b09211 · Cited by 689
Self-citationUmapathi, R., Ghoreishian, S. M., Sonwal, S., Rani, G. M., & Huh, Y. S. (2022) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2021.214305 · Cited by 547
Aptamer-based biosensors for biomedical diagnostics
Zhou, W., Jimmy Huang, P.-J., Ding, J., & Liu, J. (2014) · The Analyst · doi:10.1039/c4an00132j · Cited by 539
Generation of high-affinity DNA aptamers using an expanded genetic alphabet
Kimoto, M., Yamashige, R., Matsunaga, K.-I., Yokoyama, S., & Hirao, I. (2013) · Nature Biotechnology · doi:10.1038/nbt.2556 · Cited by 510
Ge, Z., Lin, M., Wang, P., Pei, H., Yan, J., Shi, J., Huang, Q., He, D., Fan, C., & Zuo, X. (2014) · Analytical Chemistry · doi:10.1021/ac4037262 · Cited by 501
Liu, C., Zhao, J., Tian, F., Cai, L., Zhang, W., Feng, Q., Chang, J., Wan, F., Yang, Y., Dai, B., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0343-6 · Cited by 482
McConnell, E. M., Cozma, I., Mou, Q., Brennan, J. D., Lu, Y., & Li, Y. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00240f · Cited by 477
Self-citationLin, M., Wang, J., Zhou, G., Wang, J., Wu, N., Lu, J., Gao, J., Chen, X., Shi, J., Zuo, X., et al. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201410720 · Cited by 449
Liang, M., Li, Z., Wang, W., Liu, J., Liu, L., Zhu, G., Karthik, L., Wang, M., Wang, K.-F., Wang, Z., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-11648-1 · Cited by 430
Nucleic Acid Biosensors: Recent Advances and Perspectives
Du, Y., & Dong, S. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04190 · Cited by 429
Kelley, S. O., Mirkin, C. A., Walt, D. R., Ismagilov, R. F., Toner, M., & Sargent, E. H. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.261 · Cited by 398
Lin, M., Song, P., Zhou, G., Zuo, X., Aldalbahi, A., Lou, X., Shi, J., & Fan, C. (2016) · Nature Protocols · doi:10.1038/nprot.2016.071 · Cited by 388
Upconversion Luminescence-Activated DNA Nanodevice for ATP Sensing in Living Cells
Zhao, J., Gao, J., Xue, W., Di, Z., Xing, H., Lu, Y., & Li, L. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.7b11161 · Cited by 361
Self-citationFrom Diagnosis to Treatment: Recent Advances in Patient-Friendly Biosensors and Implantable Devices
Li, P., Lee, G.-H., Kim, S. Y., Kwon, S. Y., Kim, H.-R., & Park, S. (2021) · ACS Nano · doi:10.1021/acsnano.0c06688 · Cited by 359
The Era of Digital Health: A Review of Portable and Wearable Affinity Biosensors
Tu, J., Torrente‐Rodríguez, R. M., Wang, M., & Gao, W. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201906713 · Cited by 357
Detection and beyond: challenges and advances in aptamer-based biosensors
Yoo, H., Jo, H., & Oh, S. S. (2020) · Materials Advances · doi:10.1039/d0ma00639d · Cited by 334
Yan, L., Zhu, Z., Zou, Y., Huang, Y., Liu, D., Jia, S., Xu, D., Wu, M., Zhou, Y., Zhou, S., et al. (2013) · Journal of the American Chemical Society · doi:10.1021/ja3114714 · Cited by 329
Biosensors and sensors for dopamine detection
Liu, X., & Liu, J. (2021) · VIEW · doi:10.1002/viw.20200102 · Cited by 329
Point-of-care biochemical assays using gold nanoparticle-implemented microfluidics
Sun, J., Xianyu, Y., & Jiang, X. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00125g · Cited by 323
Recent Advances in Electrochemical Immunosensors
Wen, W., Yan, X., Zhu, C., Du, D., & Lin, Y. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04281 · Cited by 313
Zhu, Z., Guan, Z., Jia, S., Lei, Z., Lin, S., Zhang, H., Ma, Y., Tian, Z., & Yang, C. J. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201405995 · Cited by 303
Lang, X.-Y., Fu, H.-Y., Hou, C., Han, G.-F., Yang, P., Liu, Y.-B., & Jiang, Q. (2013) · Nature Communications · doi:10.1038/ncomms3169 · Cited by 302
Rationally Engineered Nucleic Acid Architectures for Biosensing Applications
Xiao, M., Lai, W., Man, T., Chang, B., Li, L., Chandrasekaran, A. R., & Pei, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00121 · Cited by 290
Lake, R. J., Yang, Z., Zhang, J., & Lu, Y. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.9b00419 · Cited by 281
Self-citationAn electrochemical clamp assay for direct, rapid analysis of circulating nucleic acids in serum
Das, J., Ivanov, I., Montermini, L., Rak, J., Sargent, E. H., & Kelley, S. O. (2015) · Nature Chemistry · doi:10.1038/nchem.2270 · Cited by 274
Nucleic Acid Tests for Clinical Translation
Li, M., Yin, F., Song, L., Mao, X., Li, F., Fan, C., Zuo, X., & Xia, Q. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00241 · Cited by 264
3D NiO hollow sphere/reduced graphene oxide composite for high-performance glucose biosensor
Huang, W., Ding, S., Chen, Y., Hao, W., Lai, X., Peng, J., Tu, J., Cao, Y., & Li, X. (2017) · Scientific Reports · doi:10.1038/s41598-017-05528-1 · Cited by 259
Trends in miniaturized biosensors for point-of-care testing
Liu, D., Wang, J., Wu, L., Huang, Y., Zhang, Y., Zhu, M., Wang, Y., Zhu, Z., & Yang, C. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.115701 · Cited by 255
Multiplexed volumetric bar-chart chip for point-of-care diagnostics
Song, Y., Zhang, Y., Bernard, P. E., Reuben, J. M., Ueno, N. T., Arlinghaus, R. B., Zu, Y., & Qin, L. (2012) · Nature Communications · doi:10.1038/ncomms2292 · Cited by 220
Juska, V. B., & Pemble, M. E. (2020) · Sensors · doi:10.3390/s20216013 · Cited by 214
Aptamer-based point-of-care diagnostic platforms
Dhiman, A., Kalra, P., Bansal, V., Bruno, J. G., & Sharma, T. K. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2017.02.060 · Cited by 206
Duplexed aptamers: history, design, theory, and application to biosensing
Munzar, J. D., Ng, A., & Juncker, D. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00880a · Cited by 205
Li, L., Xing, H., Zhang, J., & Lu, Y. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.9b00167 · Cited by 204
Self-citationWang, W., Satyavolu, N. S. R., Wu, Z., Zhang, J., Zhu, J., & Lu, Y. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201701325 · Cited by 202
Self-citationABCs of DNA aptamer and related assay development
Sharma, T. K., Bruno, J. G., & Dhiman, A. (2017) · Biotechnology Advances · doi:10.1016/j.biotechadv.2017.01.003 · Cited by 174
Improving Colorimetric Assays through Protein Enzyme-Assisted Gold Nanoparticle Amplification
Xie, X., Xu, W., & Liu, X. (2012) · Accounts of Chemical Research · doi:10.1021/ar300044j · Cited by 167
Coupling Sensitive Nucleic Acid Amplification with Commercial Pregnancy Test Strips
Du, Y., Pothukuchy, A., Gollihar, J. D., Nourani, A., Li, B., & Ellington, A. D. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201609108 · Cited by 163
Zhou, J., Yin, L., Dong, Y., Peng, L., Liu, G., Man, S., & Ma, L. (2020) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.06.041 · Cited by 161
Metadata
- Authors
- Xiang, Y., & Lu, Y.
- Venue
- Nature Chemistry
- Published
- 2011-07-24
- Volume
- 3
- Issue
- 9
- Pages
- 697-703
- ISSN
- 1755-4330 (ISSN-L)
- 1755-4349
- OpenAlex
- W2120172812
- Cited by
- 677
- References
- 46
- FWCI
- 16.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.