The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Using personal glucose meters and functional DNA sensors to quantify a variety of analytical targets
Open accessAbstract
Portable, low-cost and quantitative detection of a broad range of targets at home and in the field has the potential to revolutionize medical diagnostics and environmental monitoring. Despite many years of research, very few such devices are commercially available. Taking advantage of the wide availability and low cost of the pocket-sized personal glucose meter—used worldwide by diabetes sufferers—we demonstrate a method to use such meters to quantify non-glucose targets, ranging from a recreational drug (cocaine, 3.4 μM detection limit) to an important biological cofactor (adenosine, 18 μM detection limit), to a disease marker (interferon-gamma of tuberculosis, 2.6 nM detection limit) and a toxic metal ion (uranium, 9.1 nM detection limit). The method is based on the target-induced release of invertase from a functional-DNA–invertase conjugate. The released invertase converts sucrose into glucose, which is detectable using the meter. The approach should be easily applicable to the detection of many other targets through the use of suitable functional-DNA partners (aptamers DNAzymes or aptazymes).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuerk, C., & Gold, L. (1990) · Science · doi:10.1126/science.2200121 · Cited by 10,405
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Simultaneous phase and size control of upconversion nanocrystals through lanthanide doping
Wang, F., Han, Y., Lim, C. S., Lu, Y., Wang, J., Xu, J., Chen, H., Zhang, C., Hong, M., & Liu, X. (2010) · Nature · doi:10.1038/nature08777 · Cited by 3,151
Self-citationCELLULAR RESPONSES TO INTERFERON-γ
Boehm, U., Klamp, T., Groot, M., & Howard, J. C. (1997) · Annual Review of Immunology · doi:10.1146/annurev.immunol.15.1.749 · Cited by 2,890
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
The Fluorescent Toolbox for Assessing Protein Location and Function
Giepmans, B. N. G., Adams, S. R., Ellisman, M. H., & Tsien, R. Y. (2006) · Science · doi:10.1126/science.1124618 · Cited by 2,770
Functional Nucleic Acid Sensors
Liu, J., Cao, Z., & Lu, Y. (2009) · Chemical Reviews · doi:10.1021/cr030183i · Cited by 2,187
Self-citationCreating new fluorescent probes for cell biology
Zhang, J., Campbell, R. E., Ting, A. Y., & Tsien, R. Y. (2002) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm976 · Cited by 1,981
Breaker, R. R., & Joyce, G. F. (1994) · Chemistry & Biology · doi:10.1016/1074-5521(94)90014-0 · Cited by 1,476
Song, S., Wang, L., Li, J., Fan, C., & Zhao, J. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2007.12.004 · Cited by 1,434
Hydrogen Sensors and Switches from Electrodeposited Palladium Mesowire Arrays
Favier, F., Walter, E. C., Zach, M. P., Benter, T., & Penner, R. M. (2001) · Science · doi:10.1126/science.1063189 · Cited by 1,385
A Colorimetric Lead Biosensor Using DNAzyme-Directed Assembly of Gold Nanoparticles
Liu, J., & Lu, Y. (2003) · Journal of the American Chemical Society · doi:10.1021/ja034775u · Cited by 1,347
Self-citationSelection in vitro of an RNA enzyme that specifically cleaves single-stranded DNA
Robertson, D. L., & Joyce, G. F. (1990) · Nature · doi:10.1038/344467a0 · Cited by 1,331
A DNA Aptamer That Binds Adenosine and ATP
Huizenga, D. E., & Szostak, J. W. (1995) · Biochemistry · doi:10.1021/bi00002a033 · Cited by 1,270
Nanoelectrochemistry: Metal Nanoparticles, Nanoelectrodes, and Nanopores
Murray, R. W. (2008) · Chemical Reviews · doi:10.1021/cr068077e · Cited by 1,144
Structure-Switching Signaling Aptamers
Nutiu, R., & Li, Y. (2003) · Journal of the American Chemical Society · doi:10.1021/ja028962o · Cited by 1,040
Interferon-γ assays in the immunodiagnosis of tuberculosis: a systematic review
Pai, M., Riley, L. W., & Colford, J. M. (2004) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(04)01206-x · Cited by 913
Electronic Aptamer‐Based Sensors
Willner, I., & Zayats, M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200604524 · Cited by 818
DNAzymes for sensing, nanobiotechnology and logic gate applications
Willner, I., Shlyahovsky, B., Zayats, M., & Willner, B. (2008) · Chemical Society Reviews · doi:10.1039/b718428j · Cited by 791
Xue, X., Wang, F., & Liu, X. (2008) · Journal of the American Chemical Society · doi:10.1021/ja076716c · Cited by 709
A Highly Sensitive and Selective Catalytic DNA Biosensor for Lead Ions
Li, J., & Lu, Y. (2000) · Journal of the American Chemical Society · doi:10.1021/ja0021316 · Cited by 704
Self-citationSassanfar, M., & Szostak, J. W. (1993) · Nature · doi:10.1038/364550a0 · Cited by 593
Xia, F., Zuo, X., Yang, R., Xiao, Y., Kang, D., Vallée-Bélisle, A., Gong, X., Yuen, J. D., Hsu, B. B. Y., Heeger, A. J., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1005632107 · Cited by 539
Liu, J., Brown, A. K., Meng, X., Cropek, D. M., Istok, J. D., Watson, D. B., & Lu, Y. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0607875104 · Cited by 523
Self-citationFolding-Based Electrochemical Biosensors: The Case for Responsive Nucleic Acid Architectures
Lubin, A. A., & Plaxco, K. W. (2010) · Accounts of Chemical Research · doi:10.1021/ar900165x · Cited by 506
Integration of paper-based microfluidic devices with commercial electrochemical readers
Nie, Z., Deiss, F., Liu, X., Akbulut, O., & Whitesides, G. M. (2010) · Lab on a Chip · doi:10.1039/c0lc00237b · Cited by 481
Vallon, V., Mühlbauer, B., & Osswald, H. (2006) · Physiological Reviews · doi:10.1152/physrev.00031.2005 · Cited by 448
Nucleic acid aptamers and enzymes as sensors
Navani, N. K., & Li, Y. (2006) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.04.003 · Cited by 413
Semisynthetic DNA–Protein Conjugates for Biosensing and Nanofabrication
Niemeyer, C. M. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200904930 · Cited by 369
Top ten biotechnologies for improving health in developing countries
Daar, A. S., Thorsteinsdóttir, H., Martin, D. K., Smith, A. C., Nast, S., & Singer, P. A. (2002) · Nature Genetics · doi:10.1038/ng1002-229 · Cited by 352
Liu, J., Mazumdar, D., & Lu, Y. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200603106 · Cited by 346
Self-citationLight-switching excimer probes for rapid protein monitoring in complex biological fluids
Yang, C. J., Jockusch, S., Vicens, M., Turro, N. J., & Tan, W. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508821102 · Cited by 337
Wegner, S. V., Okesli, A., Chen, P., & He, C. (2007) · Journal of the American Chemical Society · doi:10.1021/ja068342d · Cited by 271
Engineered allosteric ribozymes as biosensor components
Breaker, R. R. (2002) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(02)00281-1 · Cited by 266
Lee, J. F. (2004) · Nucleic Acids Research · doi:10.1093/nar/gkh094 · Cited by 188
MRI Detection of Thrombin with Aptamer Functionalized Superparamagnetic Iron Oxide Nanoparticles
Yigit, M. V., Mazumdar, D., & Lu, Y. (2008) · Bioconjugate Chemistry · doi:10.1021/bc7003928 · Cited by 177
Self-citationDevelopment of an Aptamer Beacon for Detection of Interferon-Gamma
Tuleuova, N., Jones, C. N., Yan, J., Ramanculov, E. M., Yokobayashi, Y., & Revzin, A. (2010) · Analytical Chemistry · doi:10.1021/ac9025237 · Cited by 146
Biosensors based on binding-modulated donor–acceptor distances
Fan, C., Plaxco, K. W., & Heeger, A. J. (2005) · Trends in biotechnology · doi:10.1016/j.tibtech.2005.02.005 · Cited by 134
Overview on self-monitoring of blood glucose
Montagnana, M., Caputo, M., Giavarina, D., & Lippi, G. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.01.002 · Cited by 116
The HealthPia GlucoPack ™ Diabetes Phone: A Usability Study
Carroll, A. E., Marrero, D. G., & Downs, S. M. (2007) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.0002 · Cited by 107
A microdevice for multiplexed detection of T-cell-secreted cytokines
Zhu, H., Stybayeva, G., Macal, M., Ramanculov, E. M., George, M. D., Dandekar, S., & Revzin, A. (2008) · Lab on a Chip · doi:10.1039/b810244a · Cited by 102
Detection of Proteins in Serum by Micromagnetic Aptamer PCR (MAP) Technology
Csordas, A. T., Gerdon, A. E., Adams, J. D., Qian, J., Oh, S. S., Xiao, Y., & Soh, H. T. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200904846 · Cited by 100
Detecting Cytokine Release from Single T-cells
Zhu, H., Stybayeva, G., Silangcruz, J., Yan, J., Ramanculov, E. M., Dandekar, S., George, M. D., & Revzin, A. (2009) · Analytical Chemistry · doi:10.1021/ac901390j · Cited by 89
Detection of Proteins in Serum by Micromagnetic Aptamer PCR (MAP) Technology
Csordas, A. T., Gerdon, A. E., Adams, J. D., Qian, J., Oh, S. S., Xiao, Y., & Soh, H. T. (2009) · Angewandte Chemie · doi:10.1002/ange.200904846 · Cited by 87
Interferon-γ-Inhibitory Oligodeoxynucleotides Alter the Conformation of Interferon-γ
Balasubramanian, V., Nguyen, L. T., Balasubramanian, S. V., & Ramanathan, M. K. (1998) · Molecular Pharmacology · doi:10.1016/s0026-895x(24)13260-9 · Cited by 28
Interferon-gamma-inhibitory oligodeoxynucleotides alter the conformation of interferon-gamma.
BALASUBRAMANIAN, V., Nguyen, L. T., Balasubramanian, S. V., et al. (1998) · PubMed · Cited by 26
Cited by
Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules
Labib, M., Sargent, E. H., & Kelley, S. O. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00220 · Cited by 976
Swan, M. (2012) · Journal of Sensor and Actuator Networks · doi:10.3390/jsan1030217 · Cited by 934
Zhou, W., Saran, R., & Liu, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00063 · Cited by 931
Gold Nanoparticles for In Vitro Diagnostics
Zhou, W., Gao, X., Liu, D., & Chen, X. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00100 · Cited by 901
Device integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
Metadata
- Authors
- Xiang, Y., & Lu, Y.
- Venue
- Nature Chemistry
- Published
- 2011-07-24
- Volume
- 3
- Issue
- 9
- Pages
- 697-703
- ISSN
- 1755-4330 (ISSN-L)
- 1755-4349
- OpenAlex
- W2120172812
- Cited by
- 677
- References
- 46
- FWCI
- 16.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.