The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
A bio-inspired swellable microneedle adhesive for mechanical interlocking with tissue
Open accessAbstract
Achieving significant adhesion to soft tissues while minimizing tissue damage poses a considerable clinical challenge. Chemical-based adhesives require tissue-specific reactive chemistry, typically inducing a significant inflammatory response. Staples are fraught with limitations including high-localized tissue stress and increased risk of infection, and nerve and blood vessel damage. Here inspired by the endoparasite Pomphorhynchus laevis, which swells its proboscis to attach to its host’s intestinal wall, we have developed a biphasic microneedle array that mechanically interlocks with tissue through swellable microneedle tips, achieving ~3.5-fold increase in adhesion strength compared with staples in skin graft fixation, and removal force of ~4.5 N cm−2 from intestinal mucosal tissue. Comprising a poly(styrene)-block-poly(acrylic acid) swellable tip and non-swellable polystyrene core, conical microneedles penetrate tissue with minimal insertion force and depth, yet high adhesion strength in their swollen state. Uniquely, this design provides universal soft tissue adhesion with minimal damage, less traumatic removal, reduced risk of infection and delivery of bioactive therapeutics. Conventional adhesives stick poorly to wet tissue because water severely undermines the adhesive chemicals they rely on. To overcome this, Yang et al. develop a bio-inspired adhesive microneedle array whose tips swell on contact with water, forming a mechanical bond to living tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amphiphilic Block Copolymers in Structure-Controlled Nanomaterial Hybrids
Förster, S., & Antonietti, M. (1998) · Advanced Materials · doi:10.1002/(sici)1521-4095(199802)10:3<195::aid-adma195>3.0.co;2-v · Cited by 1,245
Kirkham, J. J., Dwan, K. M., Altman, D. G., Gamble, C., Dodd, S., Smyth, R., & Williamson, P. R. (2010) · BMJ · doi:10.1136/bmj.c365 · Cited by 1,133
High-speed optical frequency-domain imaging
Yun, S., Tearney, G., de Boer, J., Iftimia, N., & Bouma, B. (2003) · Optics Express · doi:10.1364/oe.11.002953 · Cited by 865
Self-citationSandby-Møller, J., Poulsen, T., & Wulf, H. C. (2003) · Acta Dermato-Venereologica · doi:10.1080/00015550310015419 · Cited by 737
The Use of Fibrin Glue in Skin Grafts and Tissue-Engineered Skin Replacements: A Review
Currie, L. J., Sharpe, J. R., & Martin, R. (2001) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-200111000-00045 · Cited by 389
Skill Acquisition and Assessment for Laparoscopic Surgery
Rosser, J. C. (1997) · Archives of Surgery · doi:10.1001/archsurg.1997.01430260098021 · Cited by 389
Rational Design and Enhanced Biocompatibility of a Dry Adhesive Medical Skin Patch
Kwak, M. K., Jeong, H., & Suh, K. Y. (2011) · Advanced Materials · doi:10.1002/adma.201101694 · Cited by 342
Kinetics of skin resealing after insertion of microneedles in human subjects
Gupta, J., Gill, H. S., Andrews, S. N., & Prausnitz, M. R. (2011) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.05.021 · Cited by 342
A versatile pH sensitive chondroitin sulfate–PEG tissue adhesive and hydrogel
Strehin, I., Nahas, Z., Arora, K., Nguyen, T., & Elisseeff, J. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.12.033 · Cited by 317
New polymeric architectures with (meth)acrylic acid segments
Mori, H., & Müller, A. H. E. (2003) · Progress in Polymer Science · doi:10.1016/s0079-6700(03)00076-5 · Cited by 277
Sutures versus staples for skin closure in orthopaedic surgery: meta-analysis
Smith, T. O., Sexton, D., Mann, C., & Donell, S. (2010) · BMJ · doi:10.1136/bmj.c1199 · Cited by 264
Tissue adhesives for closure of surgical incisions
Dumville, J. C., Coulthard, P., Worthington, H. V., Riley, P., Patel, N., Darcey, J., Esposito, M., van der Elst, M., & van Waes, O. J. F. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004287.pub4 · Cited by 257
Microneedle Arrays Allow Lower Microbial Penetration Than Hypodermic Needles In Vitro
Donnelly, R. F., Singh, T. R. R., Tunney, M. M., Morrow, D. I. J., McCarron, P. A., O’Mahony, C., & Woolfson, A. D. (2009) · Pharmaceutical Research · doi:10.1007/s11095-009-9967-2 · Cited by 227
A microneedle roller for transdermal drug delivery
Park, J.-H., Choi, S.-O., Seo, S., Choy, Y. B., & Prausnitz, M. R. (2010) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2010.07.001 · Cited by 166
Abdominoplasty, Liposuction of the Flanks, and Obesity: Analyzing Risk Factors for Seroma Formation
Kim, J., & Stevenson, T. R. (2006) · Plastic and Reconstructive Surgery · doi:10.1097/01.prs.0000200056.57357.3f · Cited by 165
Arndt, K. F., Richter, A., Ludwig, S., Zimmermann, J., Kreßler, J., Kuckling, D., & Adler, H. ‐. (1999) · Acta Polymerica · doi:10.1002/(sici)1521-4044(19991201)50:11/12<383::aid-apol383>3.0.co;2-z · Cited by 163
Microfluidic Adhesion Induced by Subsurface Microstructures
Majumder, A., Ghatak, A. K., & Sharma, A. (2007) · Science · doi:10.1126/science.1145839 · Cited by 149
Microporation applications for enhancing drug delivery
Banga, A. K. (2009) · Expert Opinion on Drug Delivery · doi:10.1517/17425240902841935 · Cited by 149
Adhesive biomaterials for tissue reconstruction
Lauto, A., Mawad, D., & Foster, L. J. R. (2007) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.1771 · Cited by 138
Aldehyde‐Amine Chemistry Enables Modulated Biosealants with Tissue‐Specific Adhesion
Artzi, N., Shazly, T. M., Baker, A. B., Ramos, A. B., & Edelman, E. R. (2009) · Advanced Materials · doi:10.1002/adma.200900340 · Cited by 132
Biocompatibility of Poly(Acrylic Acid) Thin Coatings Electro-synthesized onto TiAlV-based Implants
Giglio, E. D., Cafagna, D., Ricci, M. A., Sabbatini, L., Cometa, S., Ferretti, C., & Mattioli‐Belmonte, M. (2010) · Journal of Bioactive and Compatible Polymers · doi:10.1177/0883911510372290 · Cited by 55
The Proboscis Mechanism of Acanthocephalus Ranae
Hammond, R. A. (1966) · Journal of Experimental Biology · doi:10.1242/jeb.45.2.203 · Cited by 43
Cited by
Stimuli-responsive polymers and their applications
Wei, M., Gao, Y., Li, X., & Serpe, M. J. (2017) · Polymer Chemistry · doi:10.1039/c6py01585a · Cited by 1,298
Soft Materials by Design: Unconventional Polymer Networks Give Extreme Properties
Zhao, X., Chen, X., Yuk, H., Lin, S., Liu, X., & Parada, G. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01088 · Cited by 1,161
Lee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Liu, X., Liu, J., Lin, S., & Zhao, X. (2020) · Materials Today · doi:10.1016/j.mattod.2019.12.026 · Cited by 1,023
Larrañeta, E., Lutton, R. E. M., Woolfson, A. D., & Donnelly, R. F. (2016) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2016.03.001 · Cited by 964
Metadata
- Authors
- Yang, S. Y., O'Cearbhaill, E. D., Sisk, G. C., Park, K. M., Cho, W. K., Villiger, M., Bouma, B. E., Pomahac, B., & Karp, J. M.
- Venue
- Nature Communications
- Published
- 2013-04-16
- Volume
- 4
- Issue
- 1
- Pages
- 1702-1702
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2081316578
- Cited by
- 448
- References
- 22
- FWCI
- 21.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.