The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Rapid detection of single bacteria in unprocessed blood using Integrated Comprehensive Droplet Digital Detection
Open accessAbstract
Blood stream infection or sepsis is a major health problem worldwide, with extremely high mortality, which is partly due to the inability to rapidly detect and identify bacteria in the early stages of infection. Here we present a new technology termed ‘Integrated Comprehensive Droplet Digital Detection’ (IC 3D) that can selectively detect bacteria directly from milliliters of diluted blood at single-cell sensitivity in a one-step, culture- and amplification-free process within 1.5–4 h. The IC 3D integrates real-time, DNAzyme-based sensors, droplet microencapsulation and a high-throughput 3D particle counter system. Using Escherichia coli as a target, we demonstrate that the IC 3D can provide absolute quantification of both stock and clinical isolates of E. coli in spiked blood within a broad range of extremely low concentration from 1 to 10,000 bacteria per ml with exceptional robustness and limit of detection in the single digit regime.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuerk, C., & Gold, L. (1990) · Science · doi:10.1126/science.2200121 · Cited by 10,405
In vitro selection of RNA molecules that bind specific ligands
Ellington, A. D., & Szostak, J. W. (1990) · Nature · doi:10.1038/346818a0 · Cited by 9,812
Angus, D. C., Linde-Zwirble, W. T., Lidicker, J., Clermont, G., Carcillo, J., & Pinsky, M. R. (2001) · Critical Care Medicine · doi:10.1097/00003246-200107000-00002 · Cited by 8,503
Centers for Disease Control and Prevention
(2007) · Encyclopedia of Measurement and Statistics · doi:10.4135/9781412952644.n74 · Cited by 6,444
Xia, Y., & Whitesides, G. M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5<550::aid-anie550>3.0.co;2-g · Cited by 4,285
Severe Sepsis and Septic Shock
Angus, D. C., & van der Poll, T. (2013) · New England Journal of Medicine · doi:10.1056/nejmra1208623 · Cited by 3,961
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Absolute quantification by droplet digital PCR versus analog real-time PCR
Hindson, C. M., Chevillet, J. R., Briggs, H. A., Gallichotte, E. N., Ruf, I. K., Hindson, B. J., Vessella, R. L., & Tewari, M. (2013) · Nature Methods · doi:10.1038/nmeth.2633 · Cited by 1,488
Breaker, R. R., & Joyce, G. F. (1994) · Chemistry & Biology · doi:10.1016/1074-5521(94)90014-0 · Cited by 1,476
A Microfluidic System for Controlling Reaction Networks in Time
Song, H., Tice, J. D., & Ismagilov, R. F. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390203 · Cited by 1,082
Droplet microfluidic technology for single-cell high-throughput screening
Brouzes, E., Medkova, M., Savenelli, N., Marran, D., Twardowski, M., Hutchison, J. B., Rothberg, J. M., Link, D. R., Perrimon, N., & Samuels, M. L. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0903542106 · Cited by 1,069
Droplet microfluidics for high-throughput biological assays
Guo, M. T., Rotem, A., Heyman, J. A., & Weitz, D. A. (2012) · Lab on a Chip · doi:10.1039/c2lc21147e · Cited by 1,040
Microfluidic Digital PCR Enables Multigene Analysis of Individual Environmental Bacteria
Ottesen, E. A., Hong, J. W., Quake, S. R., & Leadbetter, J. R. (2006) · Science · doi:10.1126/science.1131370 · Cited by 737
Screening of Protein Crystallization Conditions on a Microfluidic Chip Using Nanoliter-Size Droplets
Zheng, B., Roach, L. S., & Ismagilov, R. F. (2003) · Journal of the American Chemical Society · doi:10.1021/ja037166v · Cited by 697
Droplet Microfluidics—A Tool for Single‐Cell Analysis
Joensson, H. N., & Andersson Svahn, H. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200460 · Cited by 557
Detection of Bloodstream Infections in Adults: How Many Blood Cultures Are Needed?
Lee, A., Mirrett, S., Reller, L. B., & Weinstein, M. P. (2007) · Journal of Clinical Microbiology · doi:10.1128/jcm.01555-07 · Cited by 548
Quantitative and sensitive detection of rare mutations using droplet-based microfluidics
Pekin, D., Skhiri, Y., Baret, J.-C., Le Corre, D., Mazutis, L., Ben Salem, C., Millot, F., El Harrak, A., Hutchison, J. B., Larson, J. W., et al. (2011) · Lab on a Chip · doi:10.1039/c1lc20128j · Cited by 540
Boedicker, J. Q., Li, L., Kline, T. R., & Ismagilov, R. F. (2008) · Lab on a Chip · doi:10.1039/b804911d · Cited by 438
Nucleic acid aptamers and enzymes as sensors
Navani, N. K., & Li, Y. (2006) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.04.003 · Cited by 413
Longo, G., Alonso-Sarduy, L., Rio, L. M., Bizzini, A., Trampuz, A., Notz, J., Dietler, G., & Kasas, S. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2013.120 · Cited by 368
A magneto-DNA nanoparticle system for rapid detection and phenotyping of bacteria
Chung, H. J., Castro, C. M., Im, H., Lee, H., & Weissleder, R. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2013.70 · Cited by 339
Kollef, M. H. (2008) · Clinical Infectious Diseases · doi:10.1086/590061 · Cited by 248
DNA as a Versatile Chemical Component for Catalysis, Encoding, and Stereocontrol
Silverman, S. K. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906345 · Cited by 243
Fluorogenic DNAzyme Probes as Bacterial Indicators
Ali, M. M., Aguirre, S. D., Lazim, H., & Li, Y. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201100477 · Cited by 234
Self-citationA microdroplet dilutor for high-throughput screening
Niu, X., Gielen, F., Edel, J. B., & deMello, A. J. (2011) · Nature Chemistry · doi:10.1038/nchem.1046 · Cited by 199
An Efficient RNA-Cleaving DNA Enzyme that Synchronizes Catalysis with Fluorescence Signaling
Mei, S. H. J., Liu, Z., Brennan, J. D., & Li, Y. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0281232 · Cited by 188
Eastburn, D. J., Sciambi, A., & Abate, A. R. (2013) · Analytical Chemistry · doi:10.1021/ac402057q · Cited by 133
Kang, D., Ali, M. M., Zhang, K., Pone, E. J., & Zhao, W. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.03.006 · Cited by 115
Self-citationAdvances in high-throughput single-cell microtechnologies
Weaver, W. M., Tseng, P., Kunze, A., Masaeli, M., Chung, A. J., Dudani, J. S., Kittur, H., Kulkarni, R. P., & Carlo, D. D. (2013) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2013.09.005 · Cited by 106
Juul, S., Nielsen, C. J. F., Labouriau, R., Roy, A., Tesauro, C., Jensen, P. W., Harmsen, C., Kristoffersen, E. L., Chiu, Y., Frøhlich, R. F., et al. (2012) · ACS Nano · doi:10.1021/nn3038594 · Cited by 85
Zhu, Z., Zhang, W., Leng, X., Zhang, M., Guan, Z., Lu, J., & Yang, C. J. (2012) · Lab on a Chip · doi:10.1039/c2lc40461c · Cited by 83
Evaluation of FilmArray and Verigene Systems for Rapid Identification of Positive Blood Cultures
Bhatti, M. M., Boonlayangoor, S., Beavis, K. G., et al. (2014) · Journal of Clinical Microbiology · doi:10.1128/jcm.01417-14 · Cited by 82
A Sensitive DNA Enzyme-Based Fluorescent Assay for Bacterial Detection
Aguirre, S. D., ALI, M. A. M., Salena, B. J., & Li, Y. (2013) · Biomolecules · doi:10.3390/biom3030563 · Cited by 68
Self-citationAnalysis of Protein–Protein Interactions by Using Droplet‐Based Microfluidics
Srisa‐Art, M., Kang, D., Hong, J., Park, H. W., Leatherbarrow, R. J., Edel, J. B., Chang, S., & deMello, A. J. (2009) · ChemBioChem · doi:10.1002/cbic.200800841 · Cited by 65
Self-citationShi, H., Cheng, Y., Lee, K. H., Luo, R. F., Banaei, N., & Rao, J. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201402012 · Cited by 52
Cited by
Rapid identification of pathogenic bacteria using Raman spectroscopy and deep learning
Ho, C.-S., Jean, N., Hogan, C. A., Blackmon, L., Jeffrey, S. S., Holodniy, M., Banaei, N., Saleh, A. A. E., Ermon, S., & Dionne, J. (2019) · Nature Communications · doi:10.1038/s41467-019-12898-9 · Cited by 871
Quan, P.-L., Sauzade, M., & Brouzes, E. (2018) · Sensors · doi:10.3390/s18041271 · Cited by 664
McConnell, E. M., Cozma, I., Mou, Q., Brennan, J. D., Lu, Y., & Li, Y. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00240f · Cited by 477
Single-Exosome-Counting Immunoassays for Cancer Diagnostics
Liu, C., Xu, X., Li, B., Situ, B., Pan, W., Hu, Y., An, T., Yao, S., & Zheng, L. (2018) · Nano Letters · doi:10.1021/acs.nanolett.8b01184 · Cited by 406
Lin, S., Yu, Z., Chen, D., Wang, Z., Miao, J., Li, Q., Zhang, D., Song, J., & Cui, D. (2020) · Small · doi:10.1002/smll.201903916 · Cited by 353
Metadata
- Authors
- Kang, D.-K., Ali, M. M., Zhang, K., Huang, S. S., Peterson, E., Digman, M. A., Gratton, E., & Zhao, W.
- Venue
- Nature Communications
- Published
- 2014-11-13
- Volume
- 5
- Issue
- 1
- Pages
- 5427-5427
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2040654803
- Cited by
- 297
- References
- 36
- FWCI
- 13.57
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.