Conformal piezoelectric systems for clinical and experimental characterization of soft tissue biomechanics
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Mechanical assessment of soft biological tissues and organs has broad relevance in clinical diagnosis and treatment of disease. Existing characterization methods are invasive, lack microscale spatial resolution, and are tailored only for specific regions of the body under quasi-static conditions. Here, we develop conformal and piezoelectric devices that enable in vivo measurements of soft tissue viscoelasticity in the near-surface regions of the epidermis. These systems achieve conformal contact with the underlying complex topography and texture of the targeted skin, as well as other organ surfaces, under both quasi-static and dynamic conditions. Experimental and theoretical characterization of the responses of piezoelectric actuator-sensor pairs laminated on a variety of soft biological tissues and organ systems in animal models provide information on the operation of the devices. Studies on human subjects establish the clinical significance of these devices for rapid and non-invasive characterization of skin mechanical properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Mechanical properties of soft tissues were recently monitored via wearables to determine spatiotemporal changes in viscoelasticity of basal cell carcinoma lesions [147].”
From Wearables and the Medical Revolution (2018) · cites this paper as [147]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“To solve the issue of insufficient stimulation force, multi-layer stacking structure,[592] or hydraulic pressure to amplify the force have been proposed.[63,593,594]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [594]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Solar radiation is a risk factor for the major skin cancer forms including cutaneous melanoma and carcinomas (basal and squamous cells).20”
From Wearables in Medicine (2018) · cites this paper as [20]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tensional homeostasis and the malignant phenotype
Paszek, M. J., Zahir, N., Johnson, K. R., Lakins, J. N., Rozenberg, G. I., Gefen, A., Reinhart-King, C. A., Margulies, S. S., Dembo, M., Boettiger, D., et al. (2005) · Cancer Cell · doi:10.1016/j.ccr.2005.08.010 · Cited by 3,941
Theory of viscoelasticity : an introduction
Christensen, R. M. (1971) · Cited by 1,419
Skin blood flow in adult human thermoregulation: How it works, when it does not, and why
Charkoudian, N. (2003) · Mayo Clinic Proceedings · doi:10.4065/78.5.603 · Cited by 1,041
Theory of Viscoelasticity: An Introduction
Keunings, R. (1983) · Journal of Non-Newtonian Fluid Mechanics · doi:10.1016/0377-0257(83)80020-2 · Cited by 1,030
Dagdeviren, C., Su, Y., Joe, P., Yona, R., Liu, Y., Kim, Y.-S., Huang, Y., Damadoran, A. R., Xia, J., Martin, L. W., et al. (2014) · Nature Communications · doi:10.1038/ncomms5496 · Cited by 987
Self-citationConformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975
Self-citationMechanisms of sensory transduction in the skin
Lumpkin, E. A., & Caterina, M. J. (2007) · Nature · doi:10.1038/nature05662 · Cited by 859
Stratum Corneum Defensive Functions: An Integrated View
Elias, P. M. (2005) · Journal of Investigative Dermatology · doi:10.1111/j.0022-202x.2005.23668.x · Cited by 772
Cell Stiffness Is a Biomarker of the Metastatic Potential of Ovarian Cancer Cells
Xu, W., Mezencev, R., Kim, B., Wang, L., McDonald, J., & Sulchek, T. (2012) · PLoS ONE · doi:10.1371/journal.pone.0046609 · Cited by 760
Critical review of analysis and interpretation of nanoindentation test data
Fischer-Cripps, A. C. (2006) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2005.03.018 · Cited by 748
Age-related mechanical properties of human skin: An in vivo study
Escoffier, C., de Rigal, J., Rochefort, A., Vasselet, R., Léveˆque, J.-L., & Agache, P. G. (1989) · Journal of Investigative Dermatology · doi:10.1016/0022-202x(89)90058-4 · Cited by 493
Transient, Biocompatible Electronics and Energy Harvesters Based on ZnO
Dagdeviren, C., Hwang, S., Su, Y., Kim, S., Cheng, H., Gur, O., Haney, R., Omenetto, F. G., Huang, Y., & Rogers, J. A. (2013) · Small · doi:10.1002/smll.201300146 · Cited by 412
Self-citationIn vivo model of the mechanical properties of the human skin under suction
Diridollou, S., Patat, F., Gens, F., Vaillant, L., Black, D., Lagarde, J. M., Gall, Y., & Berson, M. (2000) · Skin Research and Technology · doi:10.1034/j.1600-0846.2000.006004214.x · Cited by 350
A numerical‐experimental method to characterize the non‐linear mechanical behaviour of human skin
Hendriks, F. M., Brokken, D., Van Eemeren, J. T. W. M., Oomens, C. W. J., Baaijens, F. P. T., & Horsten, J. B. A. M. (2003) · Skin Research and Technology · doi:10.1034/j.1600-0846.2003.00019.x · Cited by 347
Age-dependent biomechanical properties of the skin
Pawlaczyk, M., Lelonkiewicz, M., & Wieczorowski, M. (2013) · Advances in Dermatology and Allergology · doi:10.5114/pdia.2013.38359 · Cited by 335
Li, C., Guan, G., Reif, R., Huang, Z., & Wang, R. K. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0583 · Cited by 300
Influence of age and regional differences on skin elasticity as measured by the Cutometer®
Ryu, H. S., Joo, Y. H., Kim, S. O., Park, K. C., & Youn, S. W. (2008) · Skin Research and Technology · doi:10.1111/j.1600-0846.2008.00302.x · Cited by 295
Examination of Stratum Corneum Barrier Function In Vivo by Infrared Spectroscopy
Bommannan, D., Potts, R. O., & Guy, R. H. (1990) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12555503 · Cited by 237
TGF-β regulates the mechanical properties and composition of bone matrix
Balooch, G., Balooch, M., Nalla, R. K., Schilling, S., Filvaroff, E. H., Marshall, G. W., Marshall, S. J., Ritchie, R. O., Derynck, R., & Alliston, T. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507417102 · Cited by 209
Self-citationCell Mechanics Using Atomic Force Microscopy-Based Single-Cell Compression
Lulevich, V., Zink, T., Chen, H.-Y., Liu, F.-T., & Liu, G.-Y. (2006) · Langmuir · doi:10.1021/la060561p · Cited by 200
Piezoelectric nanoribbons for monitoring cellular deformations
Nguyen, T. D., Deshmukh, N., Nagarah, J. M., Kramer, T., Purohit, P. K., Berry, M. J., & McAlpine, M. C. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.112 · Cited by 188
Torsional elasticity of human skin in vivo
Sanders, R. (1973) · Pfl�gers Archiv European Journal of Physiology · doi:10.1007/bf00591373 · Cited by 169
In vivo Biophysical Characterization of Skin Physiological Differences in Races
Berardesca, E., de Rigal, J., Leveque, J. L., & Maibach, H. I. (1991) · Dermatology · doi:10.1159/000247752 · Cited by 166
A computational skin model: fold and wrinkle formation
Magnenat‐Thalmann, N., Kalra, P. K., Lévêque, J. L., Bazin, R., Batisse, D., & Querleux, B. (2002) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2002.806097 · Cited by 160
Assessment of elastic parameters of human skin using dynamic elastography
Gennisson, J., Baldeweck, T., Tanter, M., Catheline, S., Fink, M., Sandrin, L., Cornillon, C., & Querleux, B. (2004) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1324402 · Cited by 154
Influence of age on the wrinkling capacities of skin
Batisse, D., Bazin, R., Baldeweck, T., Querleux, B., & Lévêque, J. (2002) · Skin Research and Technology · doi:10.1034/j.1600-0846.2002.10308.x · Cited by 152
The Influence of Ageing on the in vivo Elasticity of Human Skin
Grahame, R., & Holt, P. J. L. (2009) · Gerontologia · doi:10.1159/000211681 · Cited by 152
Influence of ageing on the in vivo extensibility of human skin at a low stress
Lévêque, J., de Rigal, J., Agache, P. G., & Monneur, C. (1980) · Archives of Dermatological Research · doi:10.1007/bf00406532 · Cited by 136
Structure and function of the stratum corneum permeability barrier
Elias, P. M. (1988) · Drug Development Research · doi:10.1002/ddr.430130203 · Cited by 113
Silver, F. H., Seehra, G. P., Freeman, J. W., & DeVore, D. P. (2002) · Journal of Applied Polymer Science · doi:10.1002/app.11119 · Cited by 106
Sex‐ and site‐dependent variations in the thickness and mechanical properties of human skin in vivo
Diridollou, S., Black, D., Lagarde, J. M., Gall, Y., Berson, M., Vabre, V., Patat, F., & Vaillant, L. (2000) · International Journal of Cosmetic Science · doi:10.1111/j.1468-2494.2000.00037.x · Cited by 99
Calle, M., Lozano, Á. E., de Abajo, J., de la Campa, J. G., & Álvarez, C. (2010) · Journal of Membrane Science · doi:10.1016/j.memsci.2010.08.051 · Cited by 95
Directional variations in the extensibility of human skin
Stark, H. L. (1977) · British Journal of Plastic Surgery · doi:10.1016/0007-1226(77)90001-7 · Cited by 89
Mechanical behaviour of human epidermal and dermal layers in vivo
Hendriks, F. F. (2005) · TU/e Research Portal · doi:10.6100/ir583921 · Cited by 86
Kashibuchi, N., Hirai, Y., O’goshi, K., & Tagami, H. (2002) · Skin Research and Technology · doi:10.1034/j.1600-0846.2002.00348.x · Cited by 80
Variations with age in the mechanical properties of human skin in vivo
Alexander, H., & Cook, T. H. (2006) · Journal of Tissue Viability · doi:10.1016/s0965-206x(06)63002-7 · Cited by 80
Myocardial fiber architecture of the human heart ventricles
Fernandez‐Teran, M., & Hurlé, J. M. (1982) · The Anatomical Record · doi:10.1002/ar.1092040207 · Cited by 75
Cui, T., Lin, C.-W., Chien, C., Chao, Y. J., & Zee, J. W. V. (2010) · Journal of Power Sources · doi:10.1016/j.jpowsour.2010.08.075 · Cited by 63
The extensibility in human skin: variation according to age and site
Sugihara, T., Ohura, T., Homma, K., & Igawa, H. H. (1991) · British Journal of Plastic Surgery · doi:10.1016/0007-1226(91)90199-t · Cited by 61
Mechanical Function of the Skin: State of the Art
Barel, A., Lambrecht, R., & Clarys, P. (1998) · KARGER eBooks · doi:10.1159/000060577 · Cited by 56
Method for characterizing viscoelasticity of human gluteal tissue
Then, C., Vogl, T. J., & Silber, G. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.01.037 · Cited by 48
Richter, T., Müller, J., Schwarz, U. D., Wepf, R. A., & Wiesendanger, R. (2001) · Applied Physics A · doi:10.1007/s003390100750 · Cited by 46
A Viscoelastic Model for the Rate Effect in Transfer Printing
Cheng, H., Li, M., Wu, J. C., Carlson, A., Kim, S., Huang, Y. Y., Kang, Z., Hwang, K., & Rogers, J. A. (2012) · Journal of Applied Mechanics · doi:10.1115/1.4007851 · Cited by 42
Self-citationViscoelastic mechanical behavior of soft microcantilever-based force sensors
Lin, I.-K., Liao, Y.-M., Liu, Y., Ou, K.-S., Chen, K., & Zhang, X. (2008) · Applied Physics Letters · doi:10.1063/1.3056114 · Cited by 40
Research works printed but not linked: 3
- Friberg, S. E. Micelles, microemulsions, liquid crystals, and the structure of stratum corneum lipids. J. Soc. Cosmet. Chem. 41, 155–171 (1990).
- Reiger, M. M. & Deem, D. Skin moisturizers. II. The efects of cosmetic ingredients on human SC. J. Soc. Cosmet. Chem. 25, 253–262 (1974).
- Luengo, & Galliano, A. Scanning Probe Microscopy for Industrial Applications: Nanomechanical Characterization Vol. 12 (John Wiley, 2013).
Cited by
Trung, T. Q., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504244 · Cited by 2,160
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
“allows for determination of the mechanical properties of the underlying skin.(16) Using this”
BackgroundInfluentialWearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Self-citationTechnology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Self-citationBio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Self-citation
Metadata
- Authors
- Dagdeviren, C., Shi, Y., Joe, P., Ghaffari, R., Balooch, G., Usgaonkar, K., Gur, O., Tran, P. L., Crosby, J. R., Meyer, M., Su, Y., Chad Webb, R., Tedesco, A. S., Slepian, M. J., Huang, Y., & Rogers, J. A.
- Affiliations
- Northwestern University (US)
- University of Illinois Urbana-Champaign (US)
- MC10 (United States) (US)
- L'Oreal (United States) (US)
- University of Arizona (US)
- Max Bergmann Center of Biomaterials (DE)
- Corresponding author
- Rogers, John A.
- ORCID
- Venue
- Nature Materials
- Published
- 2015-05-18
- Volume
- 14
- Issue
- 7
- Pages
- 728-736
- ISSN
- 1476-1122 (ISSN-L)
- 1476-4660
- OpenAlex
- W1926387934
- Cited by
- 513
- References
- 44
- Citations by year
- 2026: 36 · 2025: 47 · 2024: 37 · 2023: 46 · 2022: 49 · 2021: 51 · 2020: 50 · 2019: 53 · 2018: 48 · 2017: 40 · 2016: 46 · 2015: 10
- FWCI
- 23.88
- Type
- journal article
- Language
- en
- Open access
- green
- www.osti.gov
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Nature Materials (publishedVersion)
- PubMed (publishedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- U.S. Department of Energy (DE‐FG02‐, DEFG0207ER46471, FG02-07ER46471)
- European Commission (100098212)
- Technische Universität Dresden
- Freistaat Sachsen
- University of Illinois at Urbana-Champaign
- European Regional Development Fund
- Division of Materials Research
- Basic Energy Sciences (DE‐FG02‐07ER46471, DE-FG02)
- European Social Fund (100098212)
- Division of Materials Sciences and Engineering (DE‐FG02‐07ER46471)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- soft tissue mechanics, skin viscoelasticity, piezoelectric sensors, piezoelectric actuators, epidermis, dynamic mechanical properties, animal models
- MeSH terms
- Adult, Aged, Animals, Biomechanical Phenomena, Cattle, Elasticity, Electrophysiology, Female, Humans, Male, Microscopy, Electron, Scanning, Skin, Stress, Mechanical, Viscosity, Keratinocytes, Microscopy, Confocal, Nanotechnology, Nanostructures
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.