The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Photovoltaic retinal prosthesis with high pixel density
Open accessAbstract
Retinal degenerative diseases lead to blindness due to loss of the ‘image capturing’ photoreceptors, while neurons in the ‘image-processing’ inner retinal layers are relatively well preserved. Electronic retinal prostheses seek to restore sight by electrically stimulating the surviving neurons. Most implants are powered through inductive coils, requiring complex surgical methods to implant the coil-decoder-cable-array systems that deliver energy to stimulating electrodes via intraocular cables. We present a photovoltaic subretinal prosthesis, in which silicon photodiodes in each pixel receive power and data directly through pulsed near-infrared illumination and electrically stimulate neurons. Stimulation is produced in normal and degenerate rat retinas, with pulse durations of 0.5–4 ms, and threshold peak irradiances of 0.2–10 mW mm−2, two orders of magnitude below the ocular safety limit. Neural responses were elicited by illuminating a single 70 µm bipolar pixel, demonstrating the possibility of a fully integrated photovoltaic retinal prosthesis with high pixel density. Researchers demonstrate, in both normal and degenerate rat retinas, a photovoltaic subretinal prosthesis in which the silicon photodiodes in each pixel receive power and data through pulsed near-infrared illumination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical properties of intrinsic silicon at 300 K
Green, M. A., & Keevers, M. J. (1995) · Progress in Photovoltaics Research and Applications · doi:10.1002/pip.4670030303 · Cited by 1,364
Risk factors for age-related macular degeneration
Smith, W., Assink, J., Klein, R., Mitchell, P., Klaver, C. C. W., Klein, B. E. K., Hofman, A., Jensen, S., Wang, J. J., & de Jong, P. T. V. M. (2001) · Ophthalmology · doi:10.1016/s0161-6420(00)00580-7 · Cited by 1,071
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
The Artificial Silicon Retina Microchip for the Treatment of VisionLoss From Retinitis Pigmentosa
Chow, A. Y. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.460 · Cited by 511
Maximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices
Delori, F. C., Webb, R. H., & Sliney, D. H. (2007) · Journal of the Optical Society of America A · doi:10.1364/josaa.24.001250 · Cited by 480
Retinal remodeling triggered by photoreceptor degenerations
Jones, B. W., Watt, C. B., Frederick, J. M., Baehr, W., Chen, C., Levine, E. M., Milam, A. H., Lavail, M. M., & Marc, R. E. (2003) · Journal of Comparative Neurology · doi:10.1002/cne.10703 · Cited by 476
Stone, J. L. (1992) · Archives of Ophthalmology · doi:10.1001/archopht.1992.01080230134038 · Cited by 467
Retinal remodeling during retinal degeneration
Jones, B. W., & Marc, R. E. (2005) · Experimental Eye Research · doi:10.1016/j.exer.2005.03.006 · Cited by 428
Design of a high-resolution optoelectronic retinal prosthesis
Palanker, D., Vankov, A., Huie, P., & Baccus, S. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/012 · Cited by 334
Self-citationHEREDITARY DEGENERATION OF THE RAT RETINA
Bourne, M. C., Campbell, D. A., & Tansley, K. (1938) · British Journal of Ophthalmology · doi:10.1136/bjo.22.10.613 · Cited by 311
Ahuja, A. K., Dorn, J. D., Caspi, A., McMahon, M. J., Dagnelie, G., daCruz, L., Stanga, P., Humayun, M. S., Greenberg, R. J., & Argus II Study Group (2011) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.179622 · Cited by 289
Litke, A. M., Bezayiff, N., Chichilnisky, E. J., Cunningham, W., Dabrowski, W., Grillo, A. A., Grivich, M., Grybos, P., Hottowy, P., Kachiguine, S., et al. (2004) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2004.832706 · Cited by 279
Self-citationThe epidemiology of retinitis pigmentosa in Denmark
Haim, M. (2002) · Acta Ophthalmologica Scandinavica · doi:10.1046/j.1395-3907.2002.00001.x · Cited by 265
Mazzoni, F., Novelli, E., & Strettoi, E. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.4968-08.2008 · Cited by 235
Beebe, X., & Rose, T. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.2122 · Cited by 219
Over-pulsing degrades activated iridium oxide films used for intracortical neural stimulation
Cogan, S. F., Guzelian, A. A., Agnew, W. F., Yuen, T. G. H., & McCreery, D. B. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.02.019 · Cited by 210
High-Resolution Electrical Stimulation of Primate Retina for Epiretinal Implant Design
Sekirnjak, C., Hottowy, P., Sher, A., Dabrowski, W., Litke, A. M., & Chichilnisky, E. J. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.5138-07.2008 · Cited by 194
Self-citationField, G. D., Sher, A., Gauthier, J. L., Greschner, M., Shlens, J., Litke, A. M., & Chichilnisky, E. J. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.3437-07.2007 · Cited by 185
Self-citationMORPHOMETRIC ANALYSIS OF THE MACULA IN EYES WITH DISCIFORM AGE-RELATED MACULAR DEGENERATION
KIM, S. Y., SADDA, S., PEARLMAN, J., HUMAYUN, M. S., de JUAN, E., MELIA, B. M., & GREEN, W. R. (2002) · Retina · doi:10.1097/00006982-200208000-00012 · Cited by 158
Identification and Characterization of a Y-Like Primate Retinal Ganglion Cell Type
Petrusca, D., Grivich, M. I., Sher, A., Field, G. D., Gauthier, J. L., Greschner, M., Shlens, J., Chichilnisky, E. J., & Litke, A. M. (2007) · Journal of Neuroscience · doi:10.1523/jneurosci.2836-07.2007 · Cited by 149
Self-citationNegi, S., Bhandari, R., Rieth, L. W., Wagenen, R. V., & Solzbacher, F. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.10.016 · Cited by 138
Cogan, S. F., Troyk, P. R., Ehrlich, J., Plante, T. D., & Detlefsen, D. E. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.862572 · Cited by 138
Optoelectronic retinal prosthesis: system design and performance
Loudin, J., Simanovskii, D. M., Vijayraghavan, K., Sramek, C., Butterwick, A., Huie, P., McLean, G. Y., & Palanker, D. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/1/s09 · Cited by 137
Self-citationBrummer, S. B., & Turner, M. J. (1975) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(75)80002-x · Cited by 132
Thresholds for activation of rabbit retinal ganglion cells with a subretinal electrode
Jensen, R. J., & Rizzo, J. F. (2006) · Experimental Eye Research · doi:10.1016/j.exer.2006.01.012 · Cited by 120
Curving monolithic silicon for nonplanar focal plane array applications
Dinyari, R., Rim, S.-B., Huang, K. C. Y., Catrysse, P. B., & Peumans, P. (2008) · Applied Physics Letters · doi:10.1063/1.2883873 · Cited by 117
Besch, D., Sachs, H., Szurman, P., Gülicher, D., Wilke, R. G. H., Reinert, S., Zrenner, E., Bartz‐Schmidt, K. U., & Gekeler, F. (2008) · British Journal of Ophthalmology · doi:10.1136/bjo.2007.131961 · Cited by 115
High-sensitivity rod photoreceptor input to the blue-yellow color opponent pathway in macaque retina
Field, G. D., Greschner, M., Gauthier, J. L., Rangel, C., Shlens, J., Sher, A., MARSHAK, D. W., Litke, A. M., & Chichilnisky, E. J. (2009) · Nature Neuroscience · doi:10.1038/nn.2353 · Cited by 114
Self-citationEffect of shape and coating of a subretinal prosthesis on its integration with the retina
Butterwick, A., Huie, P., Jones, B. W., Marc, R. E., Marmor, M. F., & Palanker, D. (2008) · Experimental Eye Research · doi:10.1016/j.exer.2008.09.018 · Cited by 107
Self-citationVisual Response Properties of Retinal Ganglion Cells in the Royal College of Surgeons Dystrophic Rat
Pu, M., Xu, L., & Zhang, H. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-1450 · Cited by 82
Palanker, D., Huie, P., Vankov, A., Aramant, R. B., Seiler, M. J., Fishman, H. A., Marmor, M. F., & Blumenkranz, M. S. (2004) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.03-1327 · Cited by 66
Self-citationDeMarco, P. J., Yarbrough, G. L., Yee, C. W., McLean, G. Y., Sagdullaev, B. T., Ball, S. L., & McCall, M. A. (2007) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-0811 · Cited by 64
Possible sources of neuroprotection following subretinal silicon chip implantation in RCS rats
Pardue, M. T., Phillips, M. J., Yin, H., Fernandes, A., Cheng, Y. C., Chow, A. Y., & Ball, S. L. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/006 · Cited by 62
Photodiode Circuits for Retinal Prostheses
Loudin, J., Cogan, S. F., Mathieson, K., Sher, A., & Palanker, D. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2144980 · Cited by 47
Self-citationElectrical Properties of Micro-Photodiode Arrays for Use as Artificial Retina Implant
Stelzle, M., Stett, A., Brunner, B., Graf, M., & Nisch, W. (2001) · Biomedical Microdevices · doi:10.1023/a:1011450326476 · Cited by 17
Cited by
Light in diagnosis, therapy and surgery
Yun, S. H., & Kwok, S. J. J. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0008 · Cited by 793
Syringe-injectable electronics
Liu, J., Fu, T.-M., Cheng, Z., Hong, G., Zhou, T., Jin, L., Duvvuri, M., Jiang, Z., Kruskal, P., Xie, C., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.115 · Cited by 687
Topological supramolecular network enabled high-conductivity, stretchable organic bioelectronics
Jiang, Y., Zhang, Z., Wang, Y.-X., Li, D., Coen, C.-T., Hwaun, E., Chen, G., Wu, H.-C., Zhong, D., Niu, S., et al. (2022) · Science · doi:10.1126/science.abj7564 · Cited by 617
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Choi, C., Choi, M. K., Liu, S., Kim, M., Park, O. K., Im, C., Kim, J., Qin, X., Lee, G. J., Cho, K. W., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-01824-6 · Cited by 540
Metadata
- Authors
- Mathieson, K., Loudin, J., Goetz, G., Huie, P., Wang, L., Kamins, T. I., Galambos, L., Smith, R., Harris, J. S., Sher, A., & Palanker, D.
- Venue
- Nature Photonics
- Published
- 2012-05-13
- Volume
- 6
- Issue
- 6
- Pages
- 391-397
- ISSN
- 1749-4885 (ISSN-L)
- 1749-4893
- OpenAlex
- W2107650178
- Cited by
- 467
- References
- 35
- FWCI
- 11.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.