The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Photovoltaic retinal prosthesis with high pixel density
Open accessAbstract
Retinal degenerative diseases lead to blindness due to loss of the ‘image capturing’ photoreceptors, while neurons in the ‘image-processing’ inner retinal layers are relatively well preserved. Electronic retinal prostheses seek to restore sight by electrically stimulating the surviving neurons. Most implants are powered through inductive coils, requiring complex surgical methods to implant the coil-decoder-cable-array systems that deliver energy to stimulating electrodes via intraocular cables. We present a photovoltaic subretinal prosthesis, in which silicon photodiodes in each pixel receive power and data directly through pulsed near-infrared illumination and electrically stimulate neurons. Stimulation is produced in normal and degenerate rat retinas, with pulse durations of 0.5–4 ms, and threshold peak irradiances of 0.2–10 mW mm−2, two orders of magnitude below the ocular safety limit. Neural responses were elicited by illuminating a single 70 µm bipolar pixel, demonstrating the possibility of a fully integrated photovoltaic retinal prosthesis with high pixel density. Researchers demonstrate, in both normal and degenerate rat retinas, a photovoltaic subretinal prosthesis in which the silicon photodiodes in each pixel receive power and data through pulsed near-infrared illumination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical properties of intrinsic silicon at 300 K
Green, M. A., & Keevers, M. J. (1995) · Progress in Photovoltaics Research and Applications · doi:10.1002/pip.4670030303 · Cited by 1,364
Risk factors for age-related macular degeneration
Smith, W., Assink, J., Klein, R., Mitchell, P., Klaver, C. C. W., Klein, B. E. K., Hofman, A., Jensen, S., Wang, J. J., & de Jong, P. T. V. M. (2001) · Ophthalmology · doi:10.1016/s0161-6420(00)00580-7 · Cited by 1,071
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
The Artificial Silicon Retina Microchip for the Treatment of VisionLoss From Retinitis Pigmentosa
Chow, A. Y. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.460 · Cited by 511
Maximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices
Delori, F. C., Webb, R. H., & Sliney, D. H. (2007) · Journal of the Optical Society of America A · doi:10.1364/josaa.24.001250 · Cited by 480
Retinal remodeling triggered by photoreceptor degenerations
Jones, B. W., Watt, C. B., Frederick, J. M., Baehr, W., Chen, C., Levine, E. M., Milam, A. H., Lavail, M. M., & Marc, R. E. (2003) · Journal of Comparative Neurology · doi:10.1002/cne.10703 · Cited by 476
Stone, J. L. (1992) · Archives of Ophthalmology · doi:10.1001/archopht.1992.01080230134038 · Cited by 467
Retinal remodeling during retinal degeneration
Jones, B. W., & Marc, R. E. (2005) · Experimental Eye Research · doi:10.1016/j.exer.2005.03.006 · Cited by 428
Design of a high-resolution optoelectronic retinal prosthesis
Palanker, D., Vankov, A., Huie, P., & Baccus, S. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/012 · Cited by 334
Self-citationHEREDITARY DEGENERATION OF THE RAT RETINA
Bourne, M. C., Campbell, D. A., & Tansley, K. (1938) · British Journal of Ophthalmology · doi:10.1136/bjo.22.10.613 · Cited by 311
Cited by
Light in diagnosis, therapy and surgery
Yun, S. H., & Kwok, S. J. J. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0008 · Cited by 793
Syringe-injectable electronics
Liu, J., Fu, T.-M., Cheng, Z., Hong, G., Zhou, T., Jin, L., Duvvuri, M., Jiang, Z., Kruskal, P., Xie, C., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.115 · Cited by 687
Topological supramolecular network enabled high-conductivity, stretchable organic bioelectronics
Jiang, Y., Zhang, Z., Wang, Y.-X., Li, D., Coen, C.-T., Hwaun, E., Chen, G., Wu, H.-C., Zhong, D., Niu, S., et al. (2022) · Science · doi:10.1126/science.abj7564 · Cited by 617
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Choi, C., Choi, M. K., Liu, S., Kim, M., Park, O. K., Im, C., Kim, J., Qin, X., Lee, G. J., Cho, K. W., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-01824-6 · Cited by 540
Next-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
Artificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473
Dias, M. F., Joo, K., Kemp, J. A., Fialho, S. L., da Silva Cunha, A., Woo, S. J., & Kwon, Y. J. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.10.004 · Cited by 413
Tissue damage thresholds during therapeutic electrical stimulation
Cogan, S. F., Ludwig, K. A., Welle, C. G., & Takmakov, P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/021001 · Cited by 386
The Argus® II Retinal Prosthesis System
Luo, Y. H.-L., & da Cruz, L. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.09.003 · Cited by 351
Photovoltaic restoration of sight with high visual acuity
Lorach, H., Goetz, G., Smith, R., Lei, X., Mandel, Y., Kamins, T., Mathieson, K., Huie, P., Harris, J., Sher, A., et al. (2015) · Nature Medicine · doi:10.1038/nm.3851 · Cited by 351
Self-citationA polymer optoelectronic interface restores light sensitivity in blind rat retinas
Ghezzi, D., Antognazza, M. R., Maccarone, R., Bellani, S., Lanzarini, E., Martino, N., Mete, M., Pertile, G., Bisti, S., Lanzani, G., et al. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.34 · Cited by 331
Exploration of Near-Infrared Organic Photodetectors
Li, Q., Guo, Y., & Liu, Y. (2019) · Chemistry of Materials · doi:10.1021/acs.chemmater.9b00966 · Cited by 328
A fully organic retinal prosthesis restores vision in a rat model of degenerative blindness
Maya-Vetencourt, J. F., Ghezzi, D., Antognazza, M. R., Colombo, E., Mete, M., Feyen, P., Desii, A., Buschiazzo, A., Di Paolo, M., Di Marco, S., et al. (2017) · Nature Materials · doi:10.1038/nmat4874 · Cited by 290
Glaucoma: the retina and beyond
Davis, B. M., Crawley, L., Pahlitzsch, M., Javaid, F., & Cordeiro, M. F. (2016) · Acta Neuropathologica · doi:10.1007/s00401-016-1609-2 · Cited by 281
Retinal stimulation strategies to restore vision: fundamentals and systems
Yue, L., Weiland, J. D., Roska, B., & Humayun, M. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.05.002 · Cited by 272
Bhowmick, A., & Hazarika, S. M. (2017) · Journal on Multimodal User Interfaces · doi:10.1007/s12193-016-0235-6 · Cited by 271
Photovoltaic Restoration of Central Vision in Atrophic Age-Related Macular Degeneration
Palanker, D., Le Mer, Y., Mohand-Said, S., Muqit, M., & Sahel, J. A. (2020) · Ophthalmology · doi:10.1016/j.ophtha.2020.02.024 · Cited by 227
Self-citationDesign and validation of a foldable and photovoltaic wide-field epiretinal prosthesis
Ferlauto, L., Airaghi Leccardi, M. J. I., Chenais, N. A. L., Gilliéron, S. C. A., Vagni, P., Bevilacqua, M., Wolfensberger, T. J., Sivula, K., & Ghezzi, D. (2018) · Nature Communications · doi:10.1038/s41467-018-03386-7 · Cited by 183
Powering implantable and ingestible electronics
Yang, S., Sencadas, V., You, S. S., Jia, N. Z., Srinivasan, S. S., Huang, H., Ahmed, A. E., Liang, J. Y., & Traverso, G. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202009289 · Cited by 183
Boinagrov, D., Pangratz-Fuehrer, S., Goetz, G., & Palanker, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026008 · Cited by 146
Improving the spatial resolution of epiretinal implants by increasing stimulus pulse duration
Weitz, A. C., Nanduri, D., Behrend, M. R., Gonzalez-Calle, A., Greenberg, R. J., Humayun, M. S., Chow, R. H., & Weiland, J. D. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac4877 · Cited by 154
Simultaneous perception of prosthetic and natural vision in AMD patients
Palanker, D., Le Mer, Y., Mohand-Said, S., & Sahel, J. A. (2022) · Nature Communications · doi:10.1038/s41467-022-28125-x · Cited by 140
Self-citationConformable hybrid systems for implantable bioelectronic interfaces
Fallegger, F., Schiavone, G., & Lacour, S. P. (2020) · Advanced Materials · doi:10.1002/adma.201903904 · Cited by 113
Chenais, N. A. L., Airaghi Leccardi, M. J. I., & Ghezzi, D. (2021) · Communications Materials · doi:10.1038/s43246-021-00133-2 · Cited by 110
A Fully Intraocular High-Density Self-Calibrating Epiretinal Prosthesis
Monge, M., Raj, M., Nazari, M. H., Chang, H.-C., Zhao, Y., Weiland, J. D., Humayun, M. S., Tai, Y.-C., & Emami, A. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2298334 · Cited by 85
Retinal prostheses: progress toward the next generation implants
Ghezzi, D. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00290 · Cited by 83
Bioengineering strategies for restoring vision
Cehajic-Kapetanovic, J., Singh, M. S., Zrenner, E., & MacLaren, R. E. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00836-4 · Cited by 79
Characteristics of prosthetic vision in rats with subretinal flat and pillar electrode arrays
Ho, E., Lei, X., Flores, T., Lorach, H., Huang, T., Galambos, L., Kamins, T., Harris, J., Mathieson, K., & Palanker, D. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab34b3 · Cited by 65
“After implantation, cells of the INL migrated into the space between the pillars, improving the proximity of 3D electrodes to neurons, which led to reduction in stimulation thresholds.”
InfluentialSpatially selective activation of the visual cortex via intraneural stimulation of the optic nerve
Gaillet, V., Cutrone, A., Artoni, F., Vagni, P., Mega Pratiwi, A., Romero, S. A., Lipucci Di Paola, D., Micera, S., & Ghezzi, D. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0446-8 · Cited by 73
Cortical visual prostheses: From microstimulation to functional percept
Najarpour Foroushani, A., Pack, C. C., & Sawan, M. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaa904 · Cited by 62
Bendali, A., Rousseau, L., Lissorgues, G., Scorsone, E., Djilas, M., Dégardin, J., Dubus, E., Fouquet, S., Benosman, R., Bergonzo, P., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.07.018 · Cited by 66
Photovoltaic organic interface for neuronal stimulation in the near-infrared
Airaghi Leccardi, M. J. I., Chenais, N. A. L., Ferlauto, L., Kawecki, M., Zollinger, E. G., & Ghezzi, D. (2020) · Communications Materials · doi:10.1038/s43246-020-0023-4 · Cited by 63
Optimization of pillar electrodes in subretinal prosthesis for enhanced proximity to target neurons
Flores, T., Lei, X., Huang, T., Lorach, H., Dalal, R., Galambos, L., Kamins, T., Mathieson, K., & Palanker, D. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaac39 · Cited by 57
Self-citationOptimization of return electrodes in neurostimulating arrays
Flores, T., Goetz, G., Lei, X., & Palanker, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036010 · Cited by 43
Self-citationParaskevoudi, N., & Pezaris, J. S. (2019) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2018.00073 · Cited by 39
Computational challenges and opportunities for a bi-directional artificial retina
Shah, N. P., & Chichilnisky, E. J. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/aba8b1 · Cited by 39
A Fully Integrated RF-Powered Energy-Replenishing Current-Controlled Stimulator
Ha, S., Kim, C., Park, J., Cauwenberghs, G., & Mercier, P. P. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2881800 · Cited by 35
Thorn, J. T., Migliorini, E., & Ghezzi, D. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abb5bc · Cited by 34
Retinal safety of near infrared radiation in photovoltaic restoration of sight.
Lorach, H., Wang, J., Lee, D. Y., Dalal, R., Huie, P., & Palanker, D. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.000013 · Cited by 33
Self-citationRetinal Stimulator ASIC Architecture Based on a Joint Power and Data Optical Link
Lemaire, W., Benhouria, M., Koua, K., Besrour, M., Gauthier, L.-P., Martin-Hardy, G., Rossignol, T., Roy, S., & Fontaine, R. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.3045141 · Cited by 32
Chapter 1—restoring vision to the blind: the new age of implanted visual prostheses
(2014) · Translational Vision Science & Technology · doi:10.1167/tvst.3.7.3 · Cited by 21
Improvement in reading performance through training with simulated thalamic visual prostheses
Rassia, K. E. K., & Pezaris, J. S. (2018) · Scientific Reports · doi:10.1038/s41598-018-31435-0 · Cited by 13
Metadata
- Authors
- Mathieson, K., Loudin, J., Goetz, G., Huie, P., Wang, L., Kamins, T. I., Galambos, L., Smith, R., Harris, J. S., Sher, A., & Palanker, D.
- Venue
- Nature Photonics
- Published
- 2012-05-13
- Volume
- 6
- Issue
- 6
- Pages
- 391-397
- ISSN
- 1749-4885 (ISSN-L)
- 1749-4893
- OpenAlex
- W2107650178
- Cited by
- 467
- References
- 35
- FWCI
- 11.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.