Activatable probes for diagnosing and positioning liver injury and metastatic tumors by multispectral optoacoustic tomography
Open accessThe DOI matches its Crossref record; 68 of the 68 references it cites were found in a registry or an index.
Abstract
Optoacoustic tomography (photoacoustic tomography) is an emerging imaging technology displaying great potential for medical diagnosis and preclinical research. Rationally designing activatable optoacoustic probes capable of diagnosing diseases and locating their foci can bring into full play the role of optoacoustic tomography (OAT) as a promising noninvasive imaging modality. Here we report two xanthene-based optoacoustic probes (C 1 X-OR 1 and C 2 X-OR 2) for temporospatial imaging of hepatic alkaline phosphatase (or β-galactosidase) for evaluating and locating drug-induced liver injury (or metastatic tumor). The probes rapidly respond to the disease-specific biomarkers by displaying red-shifted NIR absorption bands and generate prominent optoacoustic signals. Using multispectral optoacoustic tomography (MSOT), we can precisely localize the focus of drug-induced liver injury in mice using C 1 X-OR 1, and the metastatic tumors using C 2 X-OR 2. This work suggests that the activatable optoacoustic chromophores may potentially be applied for diagnosing and localizing disease foci, especially smaller and deeper ones.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Near-infrared fluorophores for biomedical imaging
Hong, G., Antaris, A. L., & Dai, H. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0010 · Cited by 2,985
New Strategies for Fluorescent Probe Design in Medical Diagnostic Imaging
Kobayashi, H., Ogawa, M., Alford, R., Choyke, P. L., & Urano, Y. (2010) · Chemical Reviews · doi:10.1021/cr900263j · Cited by 2,200
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
Ovarian Cancer Development and Metastasis
Lengyel, E. (2010) · The American Journal of Pathology · doi:10.2353/ajpath.2010.100105 · Cited by 1,672
A practical guide to photoacoustic tomography in the life sciences
Wang, L. V., & Yao, J. (2016) · Nature Methods · doi:10.1038/nmeth.3925 · Cited by 1,394
Carbon nanotubes as photoacoustic molecular imaging agents in living mice
De La Zerda, A., Zavaleta, C., Keren, S., Vaithilingam, S., Bodapati, S., Liu, Z., Levi, J., Smith, B. R., Ma, T.-J., Oralkan, O., et al. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.231 · Cited by 1,271
Contrast agents for molecular photoacoustic imaging
Weber, J., Beard, P. C., & Bohndiek, S. E. (2016) · Nature Methods · doi:10.1038/nmeth.3929 · Cited by 1,270
Semiconducting polymer nanoparticles as photoacoustic molecular imaging probes in living mice
Pu, K., Shuhendler, A. J., Jokerst, J. V., Mei, J., Gambhir, S. S., Bao, Z., & Rao, J. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2013.302 · Cited by 1,185
Polymer-encapsulated organic nanoparticles for fluorescence and photoacoustic imaging
Li, K., & Liu, B. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00014e · Cited by 987
The CA 125 tumour-associated antigen: a review of the literature
Jacobs, I., & Bast, R. C. (1989) · Human Reproduction · doi:10.1093/oxfordjournals.humrep.a136832 · Cited by 955
Structure and Mechanism of Alkaline Phosphatase
Coleman, J. E. (1992) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.bb.21.060192.002301 · Cited by 883
Molecular Imaging by Means of Multispectral Optoacoustic Tomography (MSOT)
Ntziachristos, V., & Razansky, D. (2010) · Chemical Reviews · doi:10.1021/cr9002566 · Cited by 776
Advances in real-time multispectral optoacoustic imaging and its applications
Taruttis, A., & Ntziachristos, V. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.29 · Cited by 594
In vivo magnetic enrichment and multiplex photoacoustic detection of circulating tumour cells
Galanzha, E. I., Shashkov, E. V., Kelly, T., Kim, J.-W., Yang, L., & Zharov, V. P. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.333 · Cited by 575
An intelligent artificial throat with sound-sensing ability based on laser induced graphene
Tao, L.-Q., Tian, H., Liu, Y., Ju, Z.-Y., Pang, Y., Chen, Y.-Q., Wang, D.-Y., Tian, X.-G., Yan, J.-C., Deng, N.-Q., et al. (2017) · Nature Communications · doi:10.1038/ncomms14579 · Cited by 558
Cheng, X., Sun, R., Yin, L., Chai, Z., Shi, H., & Gao, M. (2017) · Advanced Materials · doi:10.1002/adma.201604894 · Cited by 552
Deep in vivo photoacoustic imaging of mammalian tissues using a tyrosinase-based genetic reporter
Jathoul, A. P., Laufer, J., Ogunlade, O., Treeby, B., Cox, B., Zhang, E., Johnson, P., Pizzey, A. R., Philip, B., Marafioti, T., et al. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.22 · Cited by 442
Asanuma, D., Sakabe, M., Kamiya, M., Yamamoto, K., Hiratake, J., Ogawa, M., Kosaka, N., Choyke, P. L., Nagano, T., Kobayashi, H., et al. (2015) · Nature Communications · doi:10.1038/ncomms7463 · Cited by 418
In situ conversion of porphyrin microbubbles to nanoparticles for multimodality imaging
Huynh, E., Leung, B. Y. C., Helfield, B. L., Shakiba, M., Gandier, J.-A., Jin, C. S., Master, E. R., Wilson, B. C., Goertz, D. E., & Zheng, G. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.25 · Cited by 365
Song, G., Liang, C., Gong, H., Li, M., Zheng, X., Cheng, L., Yang, K., Jiang, X., & Liu, Z. (2015) · Advanced Materials · doi:10.1002/adma.201503006 · Cited by 353
Miao, Q., Lyu, Y., Ding, D., & Pu, K. (2016) · Advanced Materials · doi:10.1002/adma.201505681 · Cited by 270
Moon, H., Kumar, D., Kim, H., Sim, C., Chang, J.-H., Kim, J.-M., Kim, H., & Lim, D.-K. (2015) · ACS Nano · doi:10.1021/nn506516p · Cited by 266
Fan, Q., Cheng, K., Yang, Z., Zhang, R., Yang, M., Hu, X., Ma, X., Bu, L., Lu, X., Xiong, X., et al. (2015) · Advanced Materials · doi:10.1002/adma.201402972 · Cited by 264
Lv, G., Guo, W., Zhang, W., Zhang, T., Li, S., Chen, S., Eltahan, A. S., Wang, D., Wang, Y., Zhang, J., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b05419 · Cited by 256
Yu, J., Yang, C., Li, J., Ding, Y., Zhang, L., Yousaf, M. Z., Lin, J., Pang, R., Wei, L., Xu, L., et al. (2014) · Advanced Materials · doi:10.1002/adma.201305811 · Cited by 255
Qi, J., Fang, Y., Kwok, R. T. K., Zhang, X., Hu, X., Lam, J. W. Y., Ding, D., & Tang, B. Z. (2017) · ACS Nano · doi:10.1021/acsnano.7b03062 · Cited by 246
Photoacoustic Probes for Ratiometric Imaging of Copper(II)
Li, H., Zhang, P., Smaga, L. P., Hoffman, R. A., & Chan, J. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b10504 · Cited by 239
Kaplan, M. M., & Righetti, A. (1970) · Journal of Clinical Investigation · doi:10.1172/jci106260 · Cited by 237
Zhang, J., Yang, C., Zhang, R., Chen, R., Zhang, Z., Zhang, W., Peng, S., Chen, X., Liu, G., Hsu, C., et al. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201605094 · Cited by 235
Liang, X., Li, Y., Li, X., Jing, L., Deng, Z., Yue, X., Li, C., & Dai, Z. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201402338 · Cited by 233
A bioreducible N-oxide-based probe for photoacoustic imaging of hypoxia
Knox, H. J., Hedhli, J., Kim, T. W., Khalili, K., Dobrucki, L. W., & Chan, J. (2017) · Nature Communications · doi:10.1038/s41467-017-01951-0 · Cited by 221
Dragulescu-Andrasi, A., Kothapalli, S.-R., Tikhomirov, G. A., Rao, J., & Gambhir, S. S. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4010078 · Cited by 216
Wu, Y., Wang, J., Zeng, F., Huang, S., Huang, J., Xie, H., Yu, C., & Wu, S. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b11023 · Cited by 212
Self-citationA New Single 808 nm NIR Light‐Induced Imaging‐Guided Multifunctional Cancer Therapy Platform
He, F., Yang, G., Yang, P., Yu, Y., Lv, R., Li, C., Dai, Y., Gai, S., & Lin, J. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201500464 · Cited by 199
Impact of Semiconducting Perylene Diimide Nanoparticle Size on Lymph Node Mapping and Cancer Imaging
Yang, Z., Tian, R., Wu, J., Fan, Q., Yung, B. C., Niu, G., Jacobson, O., Wang, Z., Liu, G., Yu, G., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b01261 · Cited by 193
Remote light-controlled intracellular target recognition by photochromic fluorescent glycoprobes
Zhang, J., Fu, Y., Han, H.-H., Zang, Y., Li, J., He, X.-P., Feringa, B. L., & Tian, H. (2017) · Nature Communications · doi:10.1038/s41467-017-01137-8 · Cited by 185 · cited 1×
“It was calculated according to the equations (1) or (2):”
MethodDu, L., Qin, H., Ma, T., Zhang, T., & Xing, D. (2017) · ACS Nano · doi:10.1021/acsnano.7b03226 · Cited by 181
Folding Up of Gold Nanoparticle Strings into Plasmonic Vesicles for Enhanced Photoacoustic Imaging
Liu, Y., He, J., Yang, K., Yi, C., Liu, Y., Nie, L., Khashab, N. M., Chen, X., & Nie, Z. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201508616 · Cited by 180
Li, S., Chen, Y., Liu, H., Wang, Y., Liu, L., Lv, F., Li, Y., & Wang, S. (2017) · Chemistry of Materials · doi:10.1021/acs.chemmater.7b01965 · Cited by 176
Multiplexed imaging for diagnosis and therapy
Heinzmann, K., Carter, L. M., Lewis, J. S., & Aboagye, E. O. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0131-8 · Cited by 168
Sreejith, S., Joseph, J., Lin, M., Menon, N. V., Borah, P., Ng, H. J., Loong, Y. X., Kang, Y., Yu, S. W.-K., & Zhao, Y. (2015) · ACS Nano · doi:10.1021/acsnano.5b02172 · Cited by 168
Latchoumycandane, C., Goh, C. W., Ong, M. M. K., & Boelsterli, U. A. (2007) · Hepatology · doi:10.1002/hep.21475 · Cited by 167
Liu, Y., Kang, N., Lv, J., Zhou, Z., Zhao, Q., Ma, L., Chen, Z., Ren, L., & Nie, L. (2016) · Advanced Materials · doi:10.1002/adma.201506460 · Cited by 162
Chen, J., Liu, C., Hu, D., Wang, F., Wu, H., Gong, X., Liu, X., Song, L., Sheng, Z., & Zheng, H. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201603758 · Cited by 162
Glycosyltransferase and glycosidase activities in ovarian cancer patients.
Chatterjee, S. K., Bhattacharya‐Chatterjee, M., & Barlow, J. J. (1979) · PubMed · Cited by 161
Wu, J., You, L., Lan, L., Lee, H. J., Chaudhry, S. T., Li, R., Cheng, J., & Mei, J. (2017) · Advanced Materials · doi:10.1002/adma.201703403 · Cited by 160
Zhang, P., Jiang, X., Nie, X., Huang, Y. X., Zeng, F., Xia, X., & Wu, S. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.11.047 · Cited by 148
Self-citationKim, T., Lemaster, J. E., Chen, F., Li, J., & Jokerst, J. V. (2017) · ACS Nano · doi:10.1021/acsnano.7b03519 · Cited by 143
Dramatic enhancement of the detection limits of bioassays via ultrafast deposition of polydopamine
Li, J., Baird, M. A., Davis, M. A., Tai, W., Zweifel, L. S., Waldorf, K. M. A., Gale, M., Rajagopal, L., Pierce, R. H., & Gao, X. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0082 · Cited by 135
Jo, J., Lee, C. H., Kopelman, R., & Wang, X. (2017) · Nature Communications · doi:10.1038/s41467-017-00598-1 · Cited by 130
Laser-emission imaging of nuclear biomarkers for high-contrast cancer screening and immunodiagnosis
Chen, Y., Tan, X., Sun, Q., Chen, Q., Wang, W., & Fan, X. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0128-3 · Cited by 126
Zhu, C., Yang, Y., Luo, M., Yang, C., Wu, J., Chen, L., Liu, G., Wen, T., Zhu, J., & Xia, H. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201501349 · Cited by 124
Chen, Y., Yoon, S. J., Frey, W. U., Dockery, M. D., & Emelianov, S. (2017) · Nature Communications · doi:10.1038/ncomms15782 · Cited by 114
Carr, I. (1983) · Cancer and Metastasis Reviews · doi:10.1007/bf00048483 · Cited by 109
Morikawa, A., Sugiyama, T., Kato, Y., Koide, N., Jiang, G. Z., Takahashi, K., Tamada, Y., & Yokochi, T. (1996) · Infection and Immunity · doi:10.1128/iai.64.3.734-738.1996 · Cited by 105
Chen, S.-L., Chang, Y.-C., Zhang, C., Ok, J. G., Ling, T., Mihnev, M. T., Norris, T. B., & Guo, L. J. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.96 · Cited by 104
Yu, Z., Wang, M., Pan, W., Wang, H., Li, N., & Tang, B. (2017) · Chemical Science · doi:10.1039/c7sc00700k · Cited by 103
Tomaszewski, M. R., Quirós-González, I., O’Connor, J. P. B., Abeyakoon, O., Parker, G. J. M., Williams, K. J., Gilbert, F. J., & Bohndiek, S. E. (2017) · Theranostics · doi:10.7150/thno.19841 · Cited by 101
Frenette, M., Hatamimoslehabadi, M., Bellinger, S., et al. (2014) · Journal of the American Chemical Society · doi:10.1021/ja508600x · Cited by 95
Lee, D. Y., Kim, J. Y., Lee, Y., Lee, S., Miao, W., Kim, H. S., Min, J., & Jon, S. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201707137 · Cited by 93
Dinish, U. S., Song, Z., Ho, C. J. H., Balasundaram, G., Attia, A. B. E., Lu, X., Tang, B. Z., Liu, B., & Olivo, M. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201404341 · Cited by 89
Hudson, S. V., Huang, J. S., Yin, W., Albeituni, S., Rush, J. S., Khanal, A., Yan, J., Ceresa, B. P., Frieboes, H. B., & McNally, L. R. (2014) · Cancer Research · doi:10.1158/0008-5472.can-14-1656 · Cited by 73
Shi, S., Liu, Y., Chen, Y., Zhang, Z., Ding, Y., Wu, Z., Yin, J., & Nie, L. (2016) · Theranostics · doi:10.7150/thno.16633 · Cited by 70
A bioorthogonal nanosystem for imaging and in vivo tumor inhibition
Li, B., Liu, P., Wu, H., Xie, X., Chen, Z., Zeng, F., & Wu, S. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.05.036 · Cited by 63
Self-citationQuinone-fused porphyrins as contrast agents for photoacoustic imaging
Banala, S., Fokong, S., Brand, C., Andreou, C., Kräutler, B., Rueping, M., & Kiessling, F. M. (2017) · Chemical Science · doi:10.1039/c7sc01369h · Cited by 58
“In vivo self-assembled” nanoprobes for optimizing autophagy-mediated chemotherapy
Lin, Y., Wang, Y., Qiao, S., An, H., Wang, J., Ma, Y., Wang, L., & Wang, H. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.06.042 · Cited by 51
Self-citationZhu, C., Yang, Y., Luo, M., Yang, C., Wu, J., Chen, L., Liu, G., Wen, T., Zhu, J., & Xia, H. (2015) · Angewandte Chemie · doi:10.1002/ange.201501349 · Cited by 36
Photoacoustic tomography: Breathtaking whole-body imaging
Liba, O., & de la Zerda, A. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0075 · Cited by 26
Cited by
Li, H., Kim, H., Xu, F., Han, J., Yao, Q., Wang, J., Pu, K., Peng, X., & Yoon, J. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00307k · Cited by 509
Self-citationYan, R., Hu, Y., Liu, F., Wei, S., Fang, D., Shuhendler, A. J., Liu, H., Chen, H.-Y., & Ye, D. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b03649 · Cited by 389
Chemical Design of Activatable Photoacoustic Probes for Precise Biomedical Applications
Liu, Y., Teng, L., Yin, B., Meng, H., Yin, X., Huan, S., Song, G., & Zhang, X.-B. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00875 · Cited by 245
Design Strategy of Fluorescent Probes for Live Drug-Induced Acute Liver Injury Imaging
Cheng, D., Xu, W., Gong, X., Yuan, L., & Zhang, X.-B. (2021) · Accounts of Chemical Research · doi:10.1021/acs.accounts.0c00646 · Cited by 220
Ouyang, J., Sun, L., Zeng, Z., Zeng, C., Zeng, F., & Wu, S. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201913149 · Cited by 212
Self-citation
Metadata
- Authors
- Wu, Y., Huang, S., Wang, J., Sun, L., Zeng, F., & Wu, S.
- Venue
- Nature Communications
- Published
- 2018-09-28
- Volume
- 9
- Issue
- 1
- Pages
- 3983-3983
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2893402254
- Cited by
- 162
- References
- 68
- FWCI
- 7.83
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.