Transdermal electroosmotic flow generated by a porous microneedle array patch
Open accessThe DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index.
Abstract
A microneedle array is an attractive option for a minimally invasive means to break through the skin barrier for efficient transdermal drug delivery. Here, we report the applications of solid polymer-based ion-conductive porous microneedles (PMN) containing interconnected micropores for improving iontophoresis, which is a technique of enhancing transdermal molecular transport by a direct current through the skin. The PMN modified with a charged hydrogel brings three innovative advantages in iontophoresis at once: (1) lowering the transdermal resistance by low-invasive puncture of the highly resistive stratum corneum, (2) transporting of larger molecules through the interconnected micropores, and (3) generating electroosmotic flow (EOF). In particular, the PMN-generated EOF greatly enhances the transdermal molecular penetration or extraction, similarly to the flow induced by external pressure. The enhanced efficiencies of the EOF-assisted delivery of a model drug (dextran) and of the extraction of glucose are demonstrated using a pig skin sample. Furthermore, the powering of the PMN-based transdermal EOF system by a built-in enzymatic biobattery (fructose / O 2 battery) is also demonstrated as a possible totally organic iontophoresis patch.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prausnitz, M. R., & Langer, R. (2008) · Nature Biotechnology · doi:10.1038/nbt.1504 · Cited by 3,517
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Contrasting Computational Models of Mate Preference Integration Across 45 Countries
Conroy-Beam, D., Buss, D. M., Asao, K., Sorokowska, A., Sorokowski, P., Aavik, T., Akello, G., Alhabahba, M. M., Alm, C., Amjad, N., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-52748-8 · Cited by 1,770
The 500 Dalton rule for the skin penetration of chemical compounds and drugs
Bos, J. D., & Meinardi, M. M. H. M. (2000) · Experimental Dermatology · doi:10.1034/j.1600-0625.2000.009003165.x · Cited by 1,465
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Weyl Semimetals as Hydrogen Evolution Catalysts
Rajamathi, C. R., Gupta, U., Kumar, N., Yang, H., Sun, Y., Süß, V., Shekhar, C., Schmidt, M., Blumtritt, H., Werner, P., et al. (2017) · Advanced Materials · doi:10.1002/adma.201606202 · Cited by 1,358
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Kalia, Y. N., Naik, A., Garrison, J., & Guy, R. H. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.10.026 · Cited by 858
Emaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Microneedles in Drug Delivery: Progress and Challenges
Avcil, M., & Çelik, A. (2021) · Micromachines · doi:10.3390/mi12111321 · Cited by 309
Porous Conductive Textiles for Wearable Electronics
Ding, Y., Jiang, J., Wu, Y., Zhang, Y., Zhou, J., Zhang, Y., Huang, Q., & Zheng, Z. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00507 · Cited by 269
Microneedle biomedical devices
Zheng, M., Sheng, T., Yu, J., Gu, Z., & Xu, C. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00141-6 · Cited by 235
“In addition, external pressure 88 , vacuum 85 and electro-osmostic flow 89 are applied to increase the sampling speed of ISF.”
Microneedles: materials, fabrication, and biomedical applications
Luo, X., Yang, L., & Cui, Y. (2023) · Biomedical Microdevices · doi:10.1007/s10544-023-00658-y · Cited by 219
“12b, Shinya Kusama's group developed a porous microneedle array patch, and an enhanced transdermal drug delivery and glucose extraction can be obtained by applying a DC to the pig skin samples (Kusama et al. 2021).”
BackgroundSmart bioadhesives for wound healing and closure
Zhu, J., Zhou, H., Gerhard, E. M., Zhang, S., Parra Rodríguez, F. I., Pan, T., Yang, H., Lin, Y., Yang, J., & Cheng, H. (2023) · Bioactive Materials · doi:10.1016/j.bioactmat.2022.04.020 · Cited by 197
Wu, Z., Qiao, Z., Chen, S., Fan, S., Liu, Y., Qi, J., & Lim, C. T. (2024) · Communications Materials · doi:10.1038/s43246-024-00468-6 · Cited by 183
Microneedle-Mediated Transdermal Delivery of Biopharmaceuticals
Nguyen, H. X., & Nguyen, C. N. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15010277 · Cited by 175
Wearable flexible microfluidic sensing technologies
Chen, S., Qiao, Z., Niu, Y., Yeo, J. C., Liu, Y., Qi, J., Fan, S., Liu, X., Lee, J. Y., & Lim, C. T. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00094-w · Cited by 168
“In addition, hollow 118,119 or porous 120 microneedles with microchannels or porous hydrogel microneedles 121 can build pathways between the fluid-rich region and the sensing chamber (Fig.”
BackgroundYang, B., Kong, J., & Fang, X. (2022) · Nature Communications · doi:10.1038/s41467-022-31740-3 · Cited by 158
Karamikamkar, S., Yalcintas, E. P., Haghniaz, R., de Barros, N. R., Mecwan, M., Nasiri, R., Davoodi, E., Nasrollahi, F., Erdem, A., Kang, H., et al. (2023) · Advanced Science · doi:10.1002/advs.202204681 · Cited by 109
Metadata
- Authors
- Kusama, S., Sato, K., Matsui, Y., Kimura, N., Abe, H., Yoshida, S., & Nishizawa, M.
- Venue
- Nature Communications
- Published
- 2021-01-28
- Volume
- 12
- Issue
- 1
- Pages
- 658-658
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3122253115
- Cited by
- 260
- References
- 70
- FWCI
- 14.20
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.