Transdermal electroosmotic flow generated by a porous microneedle array patch
Open accessThe DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index.
Abstract
A microneedle array is an attractive option for a minimally invasive means to break through the skin barrier for efficient transdermal drug delivery. Here, we report the applications of solid polymer-based ion-conductive porous microneedles (PMN) containing interconnected micropores for improving iontophoresis, which is a technique of enhancing transdermal molecular transport by a direct current through the skin. The PMN modified with a charged hydrogel brings three innovative advantages in iontophoresis at once: (1) lowering the transdermal resistance by low-invasive puncture of the highly resistive stratum corneum, (2) transporting of larger molecules through the interconnected micropores, and (3) generating electroosmotic flow (EOF). In particular, the PMN-generated EOF greatly enhances the transdermal molecular penetration or extraction, similarly to the flow induced by external pressure. The enhanced efficiencies of the EOF-assisted delivery of a model drug (dextran) and of the extraction of glucose are demonstrated using a pig skin sample. Furthermore, the powering of the PMN-based transdermal EOF system by a built-in enzymatic biobattery (fructose / O 2 battery) is also demonstrated as a possible totally organic iontophoresis patch.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prausnitz, M. R., & Langer, R. (2008) · Nature Biotechnology · doi:10.1038/nbt.1504 · Cited by 3,517
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Contrasting Computational Models of Mate Preference Integration Across 45 Countries
Conroy-Beam, D., Buss, D. M., Asao, K., Sorokowska, A., Sorokowski, P., Aavik, T., Akello, G., Alhabahba, M. M., Alm, C., Amjad, N., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-52748-8 · Cited by 1,770
The 500 Dalton rule for the skin penetration of chemical compounds and drugs
Bos, J. D., & Meinardi, M. M. H. M. (2000) · Experimental Dermatology · doi:10.1034/j.1600-0625.2000.009003165.x · Cited by 1,465
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Weyl Semimetals as Hydrogen Evolution Catalysts
Rajamathi, C. R., Gupta, U., Kumar, N., Yang, H., Sun, Y., Süß, V., Shekhar, C., Schmidt, M., Blumtritt, H., Werner, P., et al. (2017) · Advanced Materials · doi:10.1002/adma.201606202 · Cited by 1,358
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Kalia, Y. N., Naik, A., Garrison, J., & Guy, R. H. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.10.026 · Cited by 858
Emaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839
Hydrogel‐Forming Microneedle Arrays for Enhanced Transdermal Drug Delivery
Donnelly, R. F., Singh, T. R. R., Garland, M. J., Migalska, K., Majithiya, R., McCrudden, C. M., Kole, P. L., Mahmood, T. M. T., McCarthy, H. O., & Woolfson, A. D. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201200864 · Cited by 727
Proksch, E. (2018) · The Journal of Dermatology · doi:10.1111/1346-8138.14489 · Cited by 590
Simultaneous Monitoring of Sweat and Interstitial Fluid Using a Single Wearable Biosensor Platform
Kim, J., Sempionatto, J. R., Imani, S., Hartel, M. C., Barfidokht, A., Tang, G., Campbell, A. S., Mercier, P. P., & Wang, J. (2018) · Advanced Science · doi:10.1002/advs.201800880 · Cited by 526
The role of electroosmotic flow in transdermal iontophoresis
Pikal, M. J. (2001) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(00)00138-1 · Cited by 485
Enzymatic biofuel cells: 30 years of critical advancements
Rasmussen, M., Abdellaoui, S., & Minteer, S. D. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.029 · Cited by 483
Chang, H., Zheng, M., Yu, X., Than, A., Seeni, R. Z., Kang, R., Tian, J., Khanh, D. P., Liu, L., Chen, P., et al. (2017) · Advanced Materials · doi:10.1002/adma.201702243 · Cited by 462
Donnelly, R. F., Majithiya, R., Singh, T. R. R., Morrow, D. I. J., Garland, M. J., Demir, Y. K., Migalska, K., Ryan, E., Gillen, D., Scott, C. J., et al. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0169-8 · Cited by 417
Kim, E., Erdos, G., Huang, S., Kenniston, T. W., Balmert, S. C., Carey, C. D., Raj, V. S., Epperly, M. W., Klimstra, W. B., Haagmans, B. L., et al. (2020) · eBioMedicine · doi:10.1016/j.ebiom.2020.102743 · Cited by 404
Reviews of wearable healthcare systems: Materials, devices and system integration
Lou, Z., Wang, L., Jiang, K., Wei, Z., & Shen, G. (2020) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2019.100523 · Cited by 385
Liu, X., Lister, D. L., Zhao, Z., Petrie, C. A., Zeng, X., Jones, P. J., Staff, R. A., Pokharia, A. K., Bates, J., Singh, R. N., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0187405 · Cited by 382
Recent advances of microneedles for biomedical applications: drug delivery and beyond
Yang, J., Liu, X., Fu, Y., & Song, Y. (2019) · Acta Pharmaceutica Sinica B · doi:10.1016/j.apsb.2019.03.007 · Cited by 378
Mechanisms of sampling interstitial fluid from skin using a microneedle patch
Samant, P. P., & Prausnitz, M. R. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1716772115 · Cited by 363
Lipani, L., Dupont, B. G. R., Doungmene, F., Marken, F., Tyrrell, R. M., Guy, R. H., & Ilie, A. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0112-4 · Cited by 340
Microneedles: A New Frontier in Nanomedicine Delivery
Larrañeta, E., McCrudden, M. T. C., Courtenay, A. J., & Donnelly, R. F. (2016) · Pharmaceutical Research · doi:10.1007/s11095-016-1885-5 · Cited by 339
Naderi, M. (2015) · Progress in Filtration and Separation · doi:10.1016/b978-0-12-384746-1.00014-8 · Cited by 279
Evaluation of skin absorption of drugs from topical and transdermal formulations
Ruela, A. L. M., Perissinato, A. G., Lino, M. E. D. S., Mudrik, P. S., & Pereira, G. R. (2016) · Brazilian Journal of Pharmaceutical Sciences · doi:10.1590/s1984-82502016000300018 · Cited by 272
Minimally Invasive Extraction of Dermal Interstitial Fluid for Glucose Monitoring Using Microneedles
Wang, P. M., Cornwell, M., & Prausnitz, M. R. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.131 · Cited by 267
Telang, P. S. (2013) · Indian Dermatology Online Journal · doi:10.4103/2229-5178.110593 · Cited by 244
Microneedles for drug delivery: trends and progress
Cheung, K., & Das, D. B. (2016) · Drug Delivery · doi:10.3109/10717544.2014.986309 · Cited by 244
On‐Body Bioelectronics: Wearable Biofuel Cells for Bioenergy Harvesting and Self‐Powered Biosensing
Jeerapan, I., Sempionatto, J. R., & Wang, J. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201906243 · Cited by 239
Microneedles for transdermal diagnostics: Recent advances and new horizons
Liu, G.-S., Kong, Y., Wang, Y., Luo, Y., Fan, X., Xie, X., Yang, B.-R., & Wu, M. X. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2019.119740 · Cited by 231
Fabrication of coated polymer microneedles for transdermal drug delivery
Chen, Y., Chen, B. Z., Wang, Q. L., Jin, X., & Guo, X. D. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.03.383 · Cited by 219
Mobile health: Four emerging themes of research
Varshney, U. (2014) · Decision Support Systems · doi:10.1016/j.dss.2014.06.001 · Cited by 217
Li, Y., Zhang, H., Yang, R., Laffitte, Y., Schmill, U., Hu, W., Kaddoura, M., Blondeel, E. J. M., & Cui, B. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0077-y · Cited by 210
Wearable Biofuel Cells: A Review
Bandodkar, A. J., & Wang, J. (2016) · Electroanalysis · doi:10.1002/elan.201600019 · Cited by 193
Li, Q. Y., Zhang, J. N., Chen, B. Z., Wang, Q. L., & Guo, X. D. (2017) · RSC Advances · doi:10.1039/c6ra26759a · Cited by 171
A self-adherent, bullet-shaped microneedle patch for controlled transdermal delivery of insulin
Seong, K.-Y., Seo, M.-S., Hwang, D. Y., O'Cearbhaill, E. D., Sreenan, S., Karp, J. M., & Yang, S. Y. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.03.041 · Cited by 170
Iontophoresis - An Approach for Controlled Drug Delivery: A Review
Dixit, N., Bali, V., Baboota, S., Ahuja, A., & Ali, J. (2007) · Current Drug Delivery · doi:10.2174/1567201810704010001 · Cited by 166
Curcumin in combination with anti-cancer drugs: A nanomedicine review
Batra, H., Pawar, S., & Bahl, D. (2019) · Pharmacological Research · doi:10.1016/j.phrs.2018.11.005 · Cited by 166
The GlucoWatch®biographer: a frequent, automatic and noninvasive glucose monitor
Tierney, M. J., Tamada, J. A., Potts, R. O., Eastman, R. C., Pitzer, K., Ackerman, N. R., & Fermi, S. J. (2000) · Annals of Medicine · doi:10.3109/07853890009002034 · Cited by 154
Accelerated Wound Healing on Skin by Electrical Stimulation with a Bioelectric Plaster
Kai, H., Yamauchi, T., Ogawa, Y., Tsubota, A., Magome, T., Miyake, T., Yamasaki, K., & Nishizawa, M. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700465 · Cited by 150
Self-citationCeramic microneedles and hollow microneedles for transdermal drug delivery: Two decades of research
Ita, K. B. (2018) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2018.01.004 · Cited by 150
The success of microneedle-mediated vaccine delivery into skin
Marshall, S. M., Sahm, L. J., & Moore, A. (2016) · Human Vaccines & Immunotherapeutics · doi:10.1080/21645515.2016.1171440 · Cited by 148
Maione-Silva, L., de Castro, E. G., Nascimento, T. L., Cintra, E. R., Moreira, L. C., Cintra, B. A. S., Valadares, M. C., & Lima, E. M. (2019) · Scientific Reports · doi:10.1038/s41598-018-36682-9 · Cited by 144
Programmable transdermal drug delivery of nicotine using carbon nanotube membranes
Wu, J., Paudel, K. S., Strasinger, C., Hammell, D., Stinchcomb, A. L., & Hinds, B. J. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1004714107 · Cited by 140
Microneedle-based drug and vaccine delivery via nanoporous microneedle arrays
van der Maaden, K., Lüttge, R., Vos, P. J., Bouwstra, J. A., Kersten, G. F. A., & Ploemen, I. (2015) · Drug Delivery and Translational Research · doi:10.1007/s13346-015-0238-y · Cited by 130
Review of Stratum Corneum Impedance Measurement in Non-Invasive Penetration Application
Lu, F., Wang, C., Zhao, R., Du, L., Fang, Z., Guo, X., & Zhao, Z. (2018) · Biosensors · doi:10.3390/bios8020031 · Cited by 130
Porous polymer microneedles with interconnecting microchannels for rapid fluid transport
Liu, L., Kai, H., Nagamine, K., Ogawa, Y., & Nishizawa, M. (2016) · RSC Advances · doi:10.1039/c6ra07882f · Cited by 122
Self-citationOrganic Transdermal Iontophoresis Patch with Built‐in Biofuel Cell
Ogawa, Y., Kato, K., Miyake, T., Nagamine, K., Ofuji, T., Yoshino, S., & Nishizawa, M. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400457 · Cited by 119
Self-citationAl-Kasasbeh, R., Brady, A. J., Courtenay, A. J., Larrañeta, E., McCrudden, M., O’Kane, D., Liggett, S. B., & Donnelly, R. F. (2020) · Drug Delivery and Translational Research · doi:10.1007/s13346-020-00727-2 · Cited by 118
Porous polymer coatings on metal microneedles for enhanced drug delivery
Ullah, A., Kim, C. M., & Kim, G. M. (2018) · Royal Society Open Science · doi:10.1098/rsos.171609 · Cited by 88
Padovani, R., Lehnert, T., Cettour-Rose, P., Doenlen, R., Auwerx, J. H., & Gijs, M. A. M. (2015) · Biomedical Microdevices · doi:10.1007/s10544-015-0028-9 · Cited by 81
Skin-Mountable Biosensors and Therapeutics: A Review
Lee, E. K., Kim, M. K., & Lee, C. H. (2019) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-060418-052315 · Cited by 75
Use of iontophoresis for the treatment of cancer
Byrne, J. D., Yeh, J. J., & DeSimone, J. M. (2018) · Journal of Controlled Release · doi:10.1016/j.jconrel.2018.06.020 · Cited by 74
Saluja, S., Kasha, P. C., Paturi, J., Anderson, C., Morris, R. L., & Banga, A. K. (2013) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2013.05.029 · Cited by 69
Improved focalization of electrical microstimulation using microelectrode arrays: a modeling study
Joucla, S., & Yvert, B. (2009) · PLoS ONE · doi:10.1371/journal.pone.0004828 · Cited by 68
Enzymatic fuel cells : from fundamentals to applications
Luckarift, H. R., Atanassov, P. B., & Johnson, G. R. (2014) · Cited by 67
Transdermal reverse iontophoresis: A novel technique for therapeutic drug monitoring
Giri, T. K., Chakrabarty, S., & Ghosh, B. (2016) · Journal of Controlled Release · doi:10.1016/j.jconrel.2016.12.007 · Cited by 66
Nayak, A., Das, D. B., & Vladisavljević, G. T. (2013) · Pharmaceutical Research · doi:10.1007/s11095-013-1240-z · Cited by 62
Bîrlea, S. I., Breen, P. P., Corley, G. J., Bîrlea, N. M., Quondamatteo, F., & OLaighin, G. M. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/2/231 · Cited by 38
Ghatge, S., Telke, A. A., Waghmode, T. R., Lee, Y., Lee, K., Oh, D., Shin, H., & Kim, S.-W. (2014) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-014-6116-6 · Cited by 36
Self‐Moisturizing Smart Contact Lens Employing Electroosmosis
Kusama, S., Sato, K., Yoshida, S., & Nishizawa, M. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201900889 · Cited by 32
Self-citationShort-term high glucose culture potentiates pancreatic beta cell function
Rebelato, E., Santos, L. R. B., Carpinelli, Â. R., Rorsman, P., & Abdulkader, F. (2018) · Scientific Reports · doi:10.1038/s41598-018-31325-5 · Cited by 23
Flexible galvanic skin response sensor based on vertically aligned silver nanowires
Park, S. H., Park, J., Park, H. N., Park, H. M., & Song, J. Y. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.06.125 · Cited by 22
Series-Connected Flexible Biobatteries for Higher Voltage Electrical Skin Patches
Yoshida, S., Mizuno, T., Kusama, S., Sato, K., Raut, B., & Nishizawa, M. (2019) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.9b00671 · Cited by 21
Self-citationElectroosmotic flow velocity in DNA modified nanochannels
Li, J., & Li, D. (2019) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2019.06.002 · Cited by 20
Poplawski, S. C., Johnson, M. C., Philips, P., Eberhart, L. H. J., Koch, T., & Itri, L. M. (2016) · Pain and Therapy · doi:10.1007/s40122-016-0061-2 · Cited by 16
Fluid-permeable enzymatic lactate sensors for micro-volume specimen
Kai, H., Kato, Y., Toyosato, R., & Nishizawa, M. (2018) · The Analyst · doi:10.1039/c8an00979a · Cited by 12
Self-citationMinimally-invasive transepidermal potentiometry with microneedle salt bridge
Abe, Y., Nagamine, K., Nakabayashi, M., Kai, H., Kaji, H., Yamauchi, T., Yamasaki, K., & Nishizawa, M. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0080-0 · Cited by 11
Self-citationRajamathi, C. R., Gupta, U., Kumar, N., Yang, H., Sun, Y., Süβ, V., Shekhar, C., Schmidt, M., Yan, B., Parkin, S., et al. (2016) · arXiv · doi:10.48550/arxiv.1608.03783 · Cited by 3
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Microneedles in Drug Delivery: Progress and Challenges
Avcil, M., & Çelik, A. (2021) · Micromachines · doi:10.3390/mi12111321 · Cited by 309
Porous Conductive Textiles for Wearable Electronics
Ding, Y., Jiang, J., Wu, Y., Zhang, Y., Zhou, J., Zhang, Y., Huang, Q., & Zheng, Z. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00507 · Cited by 269
Microneedle biomedical devices
Zheng, M., Sheng, T., Yu, J., Gu, Z., & Xu, C. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00141-6 · Cited by 235
“In addition, external pressure 88 , vacuum 85 and electro-osmostic flow 89 are applied to increase the sampling speed of ISF.”
Microneedles: materials, fabrication, and biomedical applications
Luo, X., Yang, L., & Cui, Y. (2023) · Biomedical Microdevices · doi:10.1007/s10544-023-00658-y · Cited by 219
“12b, Shinya Kusama's group developed a porous microneedle array patch, and an enhanced transdermal drug delivery and glucose extraction can be obtained by applying a DC to the pig skin samples (Kusama et al. 2021).”
Background
Metadata
- Authors
- Kusama, S., Sato, K., Matsui, Y., Kimura, N., Abe, H., Yoshida, S., & Nishizawa, M.
- Venue
- Nature Communications
- Published
- 2021-01-28
- Volume
- 12
- Issue
- 1
- Pages
- 658-658
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3122253115
- Cited by
- 260
- References
- 70
- FWCI
- 14.20
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.