Robotic wireless capsule endoscopy: recent advances and upcoming technologies
Open accessThe DOI matches its Crossref record; 136 of the 136 references it cites were found in a registry or an index.
Abstract
Wireless capsule endoscopy (WCE) offers a non-invasive evaluation of the digestive system, eliminating the need for sedation and the risks associated with conventional endoscopic procedures. Its significance lies in diagnosing gastrointestinal tissue irregularities, especially in the small intestine. However, existing commercial WCE devices face limitations, such as the absence of autonomous lesion detection and treatment capabilities. Recent advancements in micro-electromechanical fabrication and computational methods have led to extensive research in sophisticated technology integration into commercial capsule endoscopes, intending to supersede wired endoscopes. This Review discusses the future requirements for intelligent capsule robots, providing a comparative evaluation of various methods’ merits and disadvantages, and highlighting recent developments in six technologies relevant to WCE. These include near-field wireless power transmission, magnetic field active drive, ultra-wideband/intrabody communication, hybrid localization, AI-based autonomous lesion detection, and magnetic-controlled diagnosis and treatment. Moreover, we explore the feasibility for future “capsule surgeons”.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Iddan, G., Meron, G., Glukhovsky, A., & Swain, P. (2000) · Nature · doi:10.1038/35013140 · Cited by 3,066 · cited 2×
“It explores the state-of-the-art intelligent technologies utilized by WCE robots 7,58,125,150,199 – 202 .”
Virtually perfect? Telemedicine for COVID-19
Hollander, J. E., & Carr, B. G. (2020) · New England Journal of Medicine · doi:10.1056/nejmp2003539 · Cited by 2,970 · cited 1×
“Telemedicine: Throughout the COVID-19 pandemic, numerous telemedicine initiatives emerged, equipping clinicians with the ability to treat patients remotely from their own homes 190 .”
Guidelines for Limiting Exposure to Electromagnetic Fields (100 kHz to 300 GHz)
(2020) · Health Physics · doi:10.1097/hp.0000000000001210 · Cited by 2,081 · cited 1×
“For instance, the International Commission on Non-Ionizing Radiation Protection (ICNIRP) hasset forth the “ Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fi elds (up to 300GHz) ” 169 , which is internationally recognized as the most authoritative statement.”
Latest advances in supercapacitors: from new electrode materials to novel device designs
Wang, F., Wu, X., Yuan, X., Liu, Z., Zhang, Y., Fu, L., Zhu, Y., Zhou, Q., Wu, Y., & Huang, W. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00205j · Cited by 2,011 · cited 1×
“However,SCscontinueto encounter challenges related to low energy density 18,19 .”
Secure, privacy-preserving and federated machine learning in medical imaging
Kaissis, G. A., Makowski, M. R., Rückert, D., & Braren, R. F. (2020) · Nature Machine Intelligence · doi:10.1038/s42256-020-0186-1 · Cited by 1,676 · cited 1×
“It performs data training iterations locally and only returns computation results to the central database for integration 175 .”
Temperature effect and thermal impact in lithium-ion batteries: A review
Ma, S., Jiang, M., Tao, P., Song, C., Wu, J., Wang, J., Deng, T., & Shang, W. (2018) · Progress in Natural Science: Materials International · doi:10.1016/j.pnsc.2018.11.002 · Cited by 1,674 · cited 1×
“These polymers ’ power densities are 2000 times greater than alternatives, providing high peak current, but safety considerations warrant further analysis due to frequent temperature runawayissues 13 .”
Rappaport, T. S., Xing, Y., MacCartney, G. R., Molisch, A. F., Mellios, E., & Zhang, J. (2017) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2017.2734243 · Cited by 1,493 · cited 1×
“There is a partial overlap between the frequency bands involved in UWB communication and the frequency ranges applied by 5G mobile communication as well as amateur radio enthusiasts 173 .”
Ethical and legal challenges of artificial intelligence-driven healthcare
Gerke, S., Minssen, T., & Cohen, G. (2020) · Artificial Intelligence in Healthcare · doi:10.1016/b978-0-12-818438-7.00012-5 · Cited by 1,170 · cited 1×
“The fundamental legislation, the Health Insurance Port-ability and Accountability Act (HIPAA), has been implemented to protect patient privacy and facilitate ef fi cient data utilization and sharing through de-identi fi cation of sensitive information like names and email addresses 174 .”
OctoMag: An Electromagnetic System for 5-DOF Wireless Micromanipulation
Kummer, M. P., Abbott, J. J., Kratochvil, B. E., Borer, R., Sengul, A., & Nelson, B. J. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2010.2073030 · Cited by 1,161
Pikul, J. H., Gang Zhang, H., Cho, J., Braun, P. V., & King, W. P. (2013) · Nature Communications · doi:10.1038/ncomms2747 · Cited by 635 · cited 1×
“WCE could bene fi t from integrating custom-shaped lithium-ion polymers, which could potentially extend battery life and augment power 12 .”
An ingestible bacterial-electronic system to monitor gastrointestinal health
Mimee, M., Nadeau, P., Hayward, A., Carim, S., Flanagan, S., Jerger, L., Collins, J., McDonnell, S., Swartwout, R., Citorik, R. J., et al. (2018) · Science · doi:10.1126/science.aas9315 · Cited by 606
A decade retrospective of medical robotics research from 2010 to 2020
Dupont, P. E., Nelson, B. J., Goldfarb, M., Hannaford, B., Menciassi, A., O’Malley, M. K., Simaan, N., Valdastri, P., & Yang, G.-Z. (2021) · Science Robotics · doi:10.1126/scirobotics.abi8017 · Cited by 516
Capsule Endoscopy: From Current Achievements to Open Challenges
Ciuti, G., Menciassi, A., & Dario, P. (2011) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2011.2171182 · Cited by 466 · cited 1×
“At a power rating of approximately 20 mW, they can meet the energy demand of the capsule ’ s internal circuit for 8 – 10 h under a voltage of 3V 11 .”
Current Sampling Methods for Gut Microbiota: A Call for More Precise Devices
Tang, Q., Jin, G., Wang, G., Liu, T., Liu, X., Wang, B., & Cao, H. (2020) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2020.00151 · Cited by 455 · cited 1×
“Previous research mainly focused on analyzing excreted feces to study gut fl ora and metabolites, which could show signi fi cant differences 154 .”
Medical Micro/Nanorobots in Precision Medicine
Soto, F., Wang, J., Ahmed, R., & Demirci, U. (2020) · Advanced Science · doi:10.1002/advs.202002203 · Cited by 442
The Human Body Characteristics as a Signal Transmission Medium for Intrabody Communication
Cho, N., Yoo, J., Song, S.-J., Lee, J., Jeon, S., & Yoo, H.-J. (2007) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2007.895640 · Cited by 355 · cited 1×
“There also exists capacitive IBC, a second coupling strategy where the electrical coupling between the transmitting and receiving electrodes forms a return path via external grounding, with most of the signal transmitted through the current loop between transmitter and receiver 49 .”
A human pilot trial of ingestible electronic capsules capable of sensing different gases in the gut
Kalantar-Zadeh, K., Berean, K. J., Ha, N., Chrimes, A. F., Xu, K., Grando, D., Ou, J. Z., Pillai, N., Campbell, J. L., Brkljača, R., et al. (2018) · Nature Electronics · doi:10.1038/s41928-017-0004-x · Cited by 342 · cited 1×
“Some sensors are capable of detecting intestinal gas composition, enhancing colon health 97 .”
Towards clinically translatable in vivo nanodiagnostics
Park, S.-M., Aalipour, A., Vermesh, O., Yu, J. H., & Gambhir, S. S. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.14 · Cited by 327 · cited 1×
“Superparamagnetic iron oxide nanoparticles potentially serve as a suitable alternative material and have already been applied to numerous clinical biomedicines 166 .”
Endoscopic mucosal resection and endoscopic submucosal dissection
Kantsevoy, S. V., Adler, D. G., Conway, J., Diehl, D. L., Farraye, F. A., Kwon, R. S., Mamula, P., Rodriguez, S., Shah, R. J., Song, L. M. W. K., et al. (2008) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2008.01.037 · Cited by 321 · cited 1×
“Endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD) have established themselves as the gold standard for minimally invasive resection of early malignant gastrointestinal tract lesions, commonly integrated into wired endoscopes 191 .”
Ding, Z., Shi, H., Zhang, H., Meng, L., Fan, M., Han, C., Zhang, K., Ming, F., Xie, X., Liu, H., et al. (2019) · Gastroenterology · doi:10.1053/j.gastro.2019.06.025 · Cited by 321
Yim, S., Gultepe, E., Gracias, D. H., & Sitti, M. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2283369 · Cited by 292
A Pooled Analysis to Evaluate Results of Capsule Endoscopy Trials
Lewis, B. S., Eisen, G. M., & Friedman, S. (2005) · Endoscopy · doi:10.1055/s-2005-870353 · Cited by 289 · cited 1×
“Furthermore, the overlooked detection rate for certain lesions, such as tumors, reached a staggering 18.9% 79 .”
InfluentialFoundations of gastrointestinal-based drug delivery and future developments
Chu, J. N., & Traverso, G. (2022) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/s41575-021-00539-w · Cited by 289
Ingestible electronics for diagnostics and therapy
Steiger, C., Abramson, A., Nadeau, P., Chandrakasan, A. P., Langer, R., & Traverso, G. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0070-3 · Cited by 274
Kim, B., Lee, S., Park, J. H., & Park, J.-O. (2005) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2004.842222 · Cited by 267
Liao, Z., Hou, X., Lin-Hu, E.-Q., Sheng, J.-Q., Ge, Z.-Z., Jiang, B., Hou, X.-H., Liu, J.-Y., Li, Z., Huang, Q.-Y., et al. (2016) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2016.05.013 · Cited by 259 · cited 1×
“It has become a preferred option in the current commercial sector for magnetically controlling capsule endoscopy 114 .”
Bailey, W. H., Harrington, T., Hirata, A., Kavet, R. R., Keshvari, J., Klauenberg, B. J., Legros, A., Maxson, D. P., Osepchuk, J. M., Reilly, J. P., et al. (2019) · IEEE Access · doi:10.1109/access.2019.2954823 · Cited by 251 · cited 1×
“1-2019 TM estab-lishedbytheInstituteofElectricalandElectronicsEngineers(IEEE)also adopts a standard with minor numerical discrepancies 170 .”
Magnetically Actuated Soft Capsule Endoscope for Fine-Needle Biopsy
Son, D., Gilbert, H. B., & Sitti, M. (2019) · Soft Robotics · doi:10.1089/soro.2018.0171 · Cited by 248 · cited 3×
“Thisapproachhasprovenfeasiblein ex-vivo pig stomach experiments 150 .”
InfluentialA Cubic 3-Axis Magnetic Sensor Array for Wirelessly Tracking Magnet Position and Orientation
Hu, C., Li, M., Song, S., Yang, W., Zhang, R., & Meng, M. Q. H. (2010) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2035711 · Cited by 241 · cited 2×
“Magnetic localization, in contrast to RF localization, bene fi ts from transmission signals that are unaffected by dielectric and frequency-related path losses within body tissues 58 .”
An Ingestible Sensor for Measuring Medication Adherence
Hafezi, H., Robertson, T. L., Moon, G. D., Au-Yeung, K.-Y., Zdeblick, M. J., & Savage, G. M. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2341272 · Cited by 226 · cited 1×
“In 2015, Proteus Digital Health Inc. launched the fi rst Proteus Discover system, based on galvanic IBC, which monitors patients ’ daily medication intake in a compact size (1mm 3 ) with low power consumption 135 .”
Prolonged energy harvesting for ingestible devices
Nadeau, P., El-Damak, D., Glettig, D., Kong, Y. L., Mo, S., Cleveland, C., Booth, L., Roxhed, N., Langer, R., Chandrakasan, A. P., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0022 · Cited by 219 · cited 1×
“A prospective solution could be a new form of self-powered battery that directly harnesses the digestive system ’ s energy, transforming gastric fl uid into a virtually unlimited electrolyte supply to extend battery life 14,15 .”
An Improved Wearable Resonant Wireless Power Transfer System for Biomedical Capsule Endoscope
Basar, M. R., Ahmad, M. Y., Cho, J., & Ibrahim, F. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2801781 · Cited by 208
Software for enhanced video capsule endoscopy: challenges for essential progress
Iakovidis, D. K., & Koulaouzidis, A. (2015) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2015.13 · Cited by 203 · cited 1×
“Video localization can be classi fi ed into two primary categories: topographical video segmentation and motion estimation 65 .”
Microneedles for Drug Delivery via the Gastrointestinal Tract
Traverso, G., Schoellhammer, C. M., Schroeder, A., Maa, R., Lauwers, G. Y., Polat, B. E., Anderson, D. G., Blankschtein, D., & Langer, R. (2015) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.24182 · Cited by 202 · cited 1×
“Furthermore, for capsules that cannot maintain a cylindrical shape initially, brie fl y wrapping key components with ice may be an effective strategy 167 .”
Swain, P. C., Toor, A., Volke, F., Keller, J., Gerber, J., Rabinovitz, E., & Rothstein, R. I. (2010) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2010.01.064 · Cited by 201
A magnetic multi-layer soft robot for on-demand targeted adhesion
Chen, Z., Wang, Y., Chen, H., Law, J., Pu, H., Xie, S., Duan, F., Sun, Y., Liu, N., & Yu, J. (2024) · Nature Communications · doi:10.1038/s41467-024-44995-9 · Cited by 185 · cited 1×
“Recent studies have explored using a double magnetic fi lm as a soft valve for dual drug release 195 and multi-layered magnetically soft robots for adhering to internal wounds at various target points 196 .”
Fabrication and applications of cellulose-based nanogenerators
Zhang, M., Du, H., Liu, K., Nie, S., Xu, T., Zhang, X., & Si, C. (2021) · Advanced Composites and Hybrid Materials · doi:10.1007/s42114-021-00312-2 · Cited by 182 · cited 1×
“Nanogenera-tors are energy collectors that convert minute forces or thermal energy (like vibrations, pressure, and heat) in the environment into electrical energy 20 .”
Alaskar, H., Hussain, A., Al-Aseem, N., Liatsis, P., & Al-Jumeily, D. (2019) · Sensors · doi:10.3390/s19061265 · Cited by 173 · cited 1×
“For ulcer detection, both AlexNet and GoogLeNet have been extensively evaluated as highly accurate identi fi cation solutions in object classi fi cation, despite being time-consuming 148 .”
Son, D., Yim, S., & Sitti, M. (2016) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2015.2488361 · Cited by 172 · cited 1×
“Recent studies 59 – 61 indicate that by arranging a two-dimensional or three-dimensional (3D) array of hall-effect sensors around the capsule endoscope, positioning error can be reduced to a minimum of 1 mm, with anangular error of 5.1°.”
InfluentialBalkrishnan, R. (2005) · Medical Care · doi:10.1097/01.mlr.0000166617.68751.5f · Cited by 168 · cited 1×
“This approach has been clinically veri fi ed for reducing serious complications and worsening conditions due to medication nonadherence 132 – 134 .”
Capsule Retentions and Incomplete Capsule Endoscopy Examinations: An Analysis of 2300 Examinations
Höög, C., Bark, L.-Å., Arkani, J., Gorsetman, J., Broström, O., & Sjöqvist, U. (2011) · Gastroenterology Research and Practice · doi:10.1155/2012/518718 · Cited by 168 · cited 1×
“Additionally, the study 28 further indicates that slower gastric transit times, under conditions of passive movement, could notably increase the risk of capsule retention in the stomach.”
Gastrointestinal diseases segmentation and classification based on duo-deep architectures
Khan, M. A., Khan, M. A., Ahmed, F., Mittal, M., Goyal, L. M., Jude Hemanth, D., & Satapathy, S. C. (2020) · Pattern Recognition Letters · doi:10.1016/j.patrec.2019.12.024 · Cited by 167 · cited 1×
“The research of AI video inspections in WCE extends to the diagnosis of different tissues, encompassing but not limited to tumors 85 , polyps 86 , gastrointestinal bleeding 87 , and ulcers 88 (Fig.”
An introduction to UWB communication systems
Kshetrimayum, R. (2009) · IEEE Potentials · doi:10.1109/mpot.2009.931847 · Cited by 166 · cited 1×
“De fi nedas signals with a bandwidth of no less than 500MHz, UWB operates within 3.1 – 10 GHz frequency bands 44 .”
InfluentialEdible Electronics: The Vision and the Challenge
Sharova, A. S., Melloni, F., Lanzani, G., Bettinger, C. J., & Caironi, M. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202000757 · Cited by 165 · cited 1×
“Thesedevicesuse energy storage or harvesting techniques such as edible batteries, super-capacitors (SCs), and nanogenerators 16 , all of which are compatible with WCE.”
Feasibility of an Ingestible Sensor-Based System for Monitoring Adherence to Tuberculosis Therapy
Belknap, R., Weis, S., Brookens, A., Au-Yeung, K. Y., Moon, G., DiCarlo, L., & Reves, R. (2013) · PLoS ONE · doi:10.1371/journal.pone.0053373 · Cited by 160 · cited 1×
“This approach has been clinically veri fi ed for reducing serious complications and worsening conditions due to medication nonadherence 132 – 134 .”
Wireless powering for a self-propelled and steerable endoscopic capsule for stomach inspection
Carta, R., Tortora, G., Thoné, J., Lenaerts, B., Valdastri, P., Menciassi, A., Dario, P., & Puers, R. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.08.049 · Cited by 155
Low-Power Ultrawideband Wireless Telemetry Transceiver for Medical Sensor Applications
Gao, Y., Zheng, Y., Diao, S., Toh, W.-D., Ang, C.-W., Je, M., & Heng, C.-H. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2097262 · Cited by 153
Turan, M., Almalıoğlu, Y., Araújo, H. J., Konukoğlu, E., & Sitti, M. (2017) · Neurocomputing · doi:10.1016/j.neucom.2017.10.014 · Cited by 150 · cited 1×
“Subsequent advancements incorporated arti fi cial neural networks to enhance the VO method, improve geometric inferences, and augment positioning precision 71,72 .”
Method for navigation and control of a magnetically guided capsule endoscope in the human stomach
Keller, H., Juloski, A. L., Hironao, K., Bechtold, M., Kimura, A., Takizawa, H., & Kuth, R. (2012) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290795 · Cited by 150 · cited 2×
“Although commercial magnetic fi eld active drive systems enable basic capsule motion control (such as translation and rotation) using two joysticks 37 , they are not suitable for advanced capsules.”
Wireless Capsule Endoscopy Color Video Segmentation
Mackiewicz, M., Berens, J., & Fisher, M. H. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.926061 · Cited by 148 · cited 1×
“Topographical video segmentation leverages various image characteristics such as color, texture, and movement to divide fi lmed frames into multiple successive organ area segments, thereby facilitating accurate positioning 66 – 68 .”
Bang, S., Park, J. Y., Jeong, S. W., Kim, Y., Shim, H. B., Kim, T. S., Lee, D. H., & Song, S. Y. (2008) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2008.04.033 · Cited by 144 · cited 1×
“In 2007, the Intro-medic company released the fi rst WCE device, MiroCam®, which utilizes IBC technology 47 .”
Easy-to-Swallow Wireless Telemetry
Yuce, M. R., & Dissanayake, T. (2012) · IEEE Microwave Magazine · doi:10.1109/mmm.2012.2205833 · Cited by 144 · cited 1×
“While low frequency is easy to design and excels in skin layer penetration, its dependence on larger electronic components hinders the miniaturization process of WCE 40 .”
Development of a new engineering-based capsule for human drug absorption studies
Wilding, I. R., Hirst, P. H., & Connor, A. L. (2000) · Pharmaceutical Science & Technology Today · doi:10.1016/s1461-5347(00)00311-4 · Cited by 136 · cited 2×
“Previous studies have highlighted magnetic fi eld propulsion as an advantageous alternative 99,100,102,103 .”
Wireless Capsule Endoscopy Bleeding Images Classification Using CNN Based Model
Rustam, F., Siddique, M. A., Siddiqui, H. U. R., Ullah, S., Mehmood, A., Ashraf, I., & Choi, G. S. (2021) · IEEE Access · doi:10.1109/access.2021.3061592 · Cited by 135
Magnetic Torsion Spring Mechanism for a Wireless Biopsy Capsule
Simi, M., Gerboni, G., Menciassi, A., & Valdastri, P. (2013) · Journal of Medical Devices · doi:10.1115/1.4025185 · Cited by 130 · cited 1×
“Previous studies have highlighted magnetic fi eld propulsion as an advantageous alternative 99,100,102,103 .”
Active Locomotive Intestinal Capsule Endoscope (ALICE) System: A Prospective Feasibility Study
Lee, C. J., Choi, H., Go, G., Jeong, S., Ko, S. Y., Park, J., & Park, S. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2362117 · Cited by 129 · cited 1×
“The saddle coil scheme, fi rst employed by Jong-Oh Park and his team at Chonnam National University for an active drive on WCE robots 125 , serves as a more suitable option.”
Sun, Y., Wang, Z., Gu, J., Xia, L., Cao, Y., Zhu, X., Wen, H., Ouyang, S., Liu, R., Li, J., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-46046-9 · Cited by 126 · cited 1×
“Recent studies have explored using a double magnetic fi lm as a soft valve for dual drug release 195 and multi-layered magnetically soft robots for adhering to internal wounds at various target points 196 .”
Self-citationImproved Bag of Feature for Automatic Polyp Detection in Wireless Capsule Endoscopy Images
Yuan, Y., Li, B., & Meng, M. Q. ‐. (2015) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2015.2395429 · Cited by 124 · cited 1×
“The research of AI video inspections in WCE extends to the diagnosis of different tissues, encompassing but not limited to tumors 85 , polyps 86 , gastrointestinal bleeding 87 , and ulcers 88 (Fig.”
End-to-end design of ingestible electronics
Abdigazy, A., Arfan, M., Lazzi, G., Sideris, C., Abramson, A., & Khan, Y. (2024) · Nature Electronics · doi:10.1038/s41928-024-01122-2 · Cited by 115 · cited 1×
“Abdigazy et al. 183 discussed the end-to-end design of seven key components including sensors, actuators, and integrated circuits.”
Ingestible Wireless Capsule Technology: A Review of Development and Future Indication
Basar, M. R., Malek, F., Juni, K. M., Idris, M. S., & Saleh, M. I. M. (2012) · International Journal of Antennas and Propagation · doi:10.1155/2012/807165 · Cited by 114
Rahim, T., Usman, M. A., & Shin, S. Y. (2020) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2020.101767 · Cited by 112 · cited 1×
“Throughout its journey within the gastrointestinal tract, a capsule endoscope routinely generates beyond 60,000 images 78 .”
Magnetically Actuated Capsule Robots: A Review
Chen, W., Sui, J., & Wang, C. (2022) · IEEE Access · doi:10.1109/access.2022.3197632 · Cited by 111 · cited 1×
“A typical functional structure occupies a lot of space in the capsule, even making the capsule too large to swallow 187 .”
Lien, G., Liu, C., Jiang, J., Chuang, C.-L., & Teng, M.-T. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2198061 · Cited by 110 · cited 1×
“The literature 113 presented a handheld external magnetic fi eld navigator (MFN) for WCE, which empowers endoscope operators with the ability to remotely moderate the capsule ’ s motion and viewing area.”
Wireless robotic capsule endoscopy: state-of-the-art and challenges
Meng, M. Q.-H., Mei, T., Pu, J., Hu, C., Wang, X., & Chan, Y. (2004) · World Congress on Intelligent Control and Automation · doi:10.1109/wcica.2004.1343799 · Cited by 109 · cited 1×
“This inherent limitation precludes a more extensive examination of speci fi c sites within the gastrointestinal tract, contributing to an appreciable omission rate of up to 30% 27 .”
Human-centric connectivity enabled by body-coupled communications
Baldus, H., Corroy, S., Fazzi, A., Klabunde, K., & Schenk, T. C. W. (2009) · IEEE Communications Magazine · doi:10.1109/mcom.2009.5116816 · Cited by 108 · cited 1×
“By limiting the communication range to a very small area on the surface of the human body, IBC minimizes the potential for interference between various networks 50 .”
Hoang, M. C., Nguyen, K. T., Le, V. H., Kim, J., Choi, E., Kang, B., Park, J., & Kim, C. (2021) · IEEE Transactions on Systems Man and Cybernetics Systems · doi:10.1109/tsmc.2019.2917298 · Cited by 107 · cited 1×
“The team further engineered two rectangular coil drive systems, the MACE 126 , and EMS 39 (Fig.”
Automated Topographic Segmentation and Transit Time Estimation in Endoscopic Capsule Exams
Cunha, J. P. S., Coimbra, M. T., Campos, P., & Soares, J. M. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.901430 · Cited by 105
Song, Y., Hao, Q., Zhang, K., Wang, M., Chu, Y., & Kang, B. (2010) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2010.2087870 · Cited by 103 · cited 15×
“For IBC, recent research majorly focuses on achieving bidirectional communication and drug release monitoring.”
InfluentialFaerber, J., Gregson, R., Clutton, R. E., Khan, S. R., Cochran, S., Desmulliez, M. P. Y., Cummins, G., Pavuluri, S. K., Record, P. M., Rodriguez, A. R. A., et al. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2759254 · Cited by 95 · cited 1×
“Giventhecomplexityofdirectmeasurements,a common alternative involves tracking the temperature elevation in exvivobiologicaltissues 171 .”
An Edible and Nutritive Zinc-Ion Micro-supercapacitor in the Stomach with Ultrahigh Energy Density
Chen, K., Yan, L., Sheng, Y., Ma, Y., Qu, L., & Zhao, Y. (2022) · ACS Nano · doi:10.1021/acsnano.2c06656 · Cited by 88
An Edible Rechargeable Battery
Ilic, I. K., Galli, V., Lamanna, L., Cataldi, P., Pasquale, L., Annese, V. F., Athanassiou, A., & Caironi, M. (2023) · Advanced Materials · doi:10.1002/adma.202211400 · Cited by 88
An Ultrawideband Conformal Capsule Antenna With Stable Impedance Matching
Bao, Z., Guo, Y., & Mittra, R. (2017) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2017.2741027 · Cited by 88 · cited 1×
“Ultra-wideband (UWB) communication, capable of achieving data transmissionexceeding100Mb/s,substantiallyenhancesvideoquality while decreasing power consumption, making it an ideal choice for burgeoningresearchintothewirelessinterfacesofWCE 42,43 .”
Nadimi, E. S., Buijs, M. M., Herp, J., Krøijer, R., Kobæk-Larsen, M., Nielsen, E., Pedersen, C. D., Blanes‐Vidal, V., & Baatrup, G. (2019) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2019.106531 · Cited by 84
Deep learning-based prediction model for diagnosing gastrointestinal diseases using endoscopy images
Sharma, A., Kumar, R., & Garg, P. (2023) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2023.105142 · Cited by 84 · cited 1×
“A recent study introduced a multipathology system for WCE images, aiming to detect andclassifydifferentlesionswithinthedigestivesystem 149 .”
Smart pills for gastrointestinal diagnostics and therapy
Cummins, G. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.113931 · Cited by 81 · cited 1×
“Temperature-sensing capsules primarily monitor athletes ’ core body temperatures during training 94 .”
Shokrollahi, P., Lai, Y. P., Ahmadi, S. R., Stewart, V., Mohammadigheisar, M., Huber, L., Matsuura, N., Zavodni, A. E. H., Parkinson, J., & Diller, E. (2020) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2020.3043454 · Cited by 80 · cited 1×
“Recently scholars have delved into fl uid sampling at physiologically relevant sites within the gastrointestinal tract using a magnetic-controlled capsule 155 – 158 .”
An oral microjet vaccination system elicits antibody production in rabbits
Aran, K., Chooljian, M. S., Paredes, J., Rafi, M. A., Lee, K., Kim, A. Y., An, J., Yau, J. F., Chum, H. H., Conboy, I. M., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf6413 · Cited by 80 · cited 1×
“For example, capsules using a chemical-reaction trigger mechanism mostly have just a single energy conversion scope unless re fi lled with chemicals after dismantling 172 .”
Magnetically driven medical devices: a review
Sliker, L. J., Ciuti, G., Rentschler, M. E., & Menciassi, A. (2015) · Expert Review of Medical Devices · doi:10.1586/17434440.2015.1080120 · Cited by 77 · cited 1×
“In contrast to the movable external magnet system, the electro-magnetic coil system signi fi cantly improves fl exibility in controlling the capsule robot ’ s magnetic fi eld, encompassing modulation of fi eld power and magnetic fi eld toggling 119 .”
Popek, K. M., Hermans, T., & Abbott, J. J. (2017) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2017.7989138 · Cited by 77 · cited 1×
“On the other hand, CRMA involves a continuously rotating external spherical magnet to generate a rotating magnetic fi eld, driving the externally threaded capsule forward in a spiraling motion 117 .”
Ke, Q., Luo, W., Yan, G., & Yang, K. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2469137 · Cited by 76
Miniature magneto-mechanical resonators for wireless tracking and sensing
Gleich, B., Schmale, I., Tolker‐Nielsen, T., & Rahmer, J. (2023) · Science · doi:10.1126/science.adf5451 · Cited by 76 · cited 1×
“The magneto-mechanical resonator, as recently proposed by Gleich and colleagues 64 , introduces a special magnetic positioning method capable of achieving six degrees of freedom positioning, covering three-dimensional position and direction.”
Xu, Y., Li, K., Zhao, Z., & Meng, M. Q. ‐. (2020) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2020.3013954 · Cited by 76 · cited 1×
“The synchronous magnetic actuation and positioning strategy proposed by Xu et al. 184 provides a valuable solution.”
Bioinspired, ingestible electroceutical capsules for hunger-regulating hormone modulation
Ramadi, K. B., McRae, J. C., Selsing, G., Su, A., Fernandes, R., Hickling, M., Rios, B., Babaee, S., Min, S., Gwynne, D., et al. (2023) · Science Robotics · doi:10.1126/scirobotics.ade9676 · Cited by 74 · cited 1×
“For instance, ingestible electroceutical capsules with circumferential electrodes on the shell surface 193 or conductive hooked probes integrated within 194 help regulate hormone release and enhance gastrointestinal tissue activity.”
Ingestible transiently anchoring electronics for microstimulation and conductive signaling
Abramson, A., Dellal, D., Kong, Y. L., Zhou, J., Gao, Y., Collins, J. E., Tamang, S. M., Wainer, J., McManus, R., Hayward, A. M., et al. (2020) · Science Advances · doi:10.1126/sciadv.aaz0127 · Cited by 73
Detection of abnormality in wireless capsule endoscopy images using fractal features
Jain, S., Seal, A., Ojha, A., Krejcar, O., Bureš, J., Tachecí, I., & Yazidi, A. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.104094 · Cited by 73 · cited 1×
“Additionally, other methodologies such as random forest 140 and K-means clustering 141 were also involved.”
Hoang, M. C., Le, V. H., Kim, J., Choi, E., Kang, B., Park, J., & Kim, C. (2019) · IEEE Access · doi:10.1109/access.2019.2927894 · Cited by 73 · cited 1×
“As detailed in the literatures 152,153 , the capsule robot integrates four synchronously manipulated scrapers by internal magnets (Fig.”
WCE Abnormality Detection Based on Saliency and Adaptive Locality-Constrained Linear Coding
Yuan, Y., Li, B., & Meng, M. Q. ‐. (2016) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2016.2610579 · Cited by 69 · cited 1×
“Additionally, other methodologies such as random forest 140 and K-means clustering 141 were also involved.”
Magnetic shells for gastrointestinal endoscopic capsules as a means to control their motion
Carpi, F., Galbiati, S., & Carpi, A. (2006) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2006.07.001 · Cited by 69
Video-based measurements for wireless capsule endoscope tracking
Spyrou, E., & Iakovidis, D. K. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/25/1/015002 · Cited by 68 · cited 1×
“Besides determining the capsule ’ s position, VO can also infer directional information by estimating displacements and rotations of interest points within consecutive frames 73 .”
A new endoscopic microcapsule robot using beetle inspired microfibrillar adhesives
Cheung, E., Karagozler, M. E., Park, S., Kim, B. K., & Sitti, M. (2006) · IEEE/ASME International Conference on Advanced Intelligent Mechatronics · doi:10.1109/aim.2005.1511040 · Cited by 65
Ding, Z., Wang, W., Zhang, K., Ming, F., Yangdai, T., Xu, T., Shi, H., Bao, Y., Yao, H., Peng, H., et al. (2021) · Gut · doi:10.1136/gutjnl-2020-322465 · Cited by 60
Mostafalu, P., & Sonkusale, S. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.040 · Cited by 60 · cited 1×
“A prospective solution could be a new form of self-powered battery that directly harnesses the digestive system ’ s energy, transforming gastric fl uid into a virtually unlimited electrolyte supply to extend battery life 14,15 .”
Near-field wireless power transfer used in biomedical implants: a comprehensive review
Mahmood, A. I., Gharghan, S. K., Eldosoky, M. A., & Soliman, A. M. (2022) · IET Power Electronics · doi:10.1049/pel2.12351 · Cited by 59 · cited 1×
“Of these, near-fi eld transmission stands out for its high ef fi ciency over short distances, making it a valuable tool in a host of implantable medical devices, includingleftventricularassistdevices,heartrate sensors,and deep brain stimulators 23 .”
Miniaturized 3-D Cross-Type Receiver for Wirelessly Powered Capsule Endoscopy
Khan, S. R., Pavuluri, S. K., Cummins, G., & Desmulliez, M. P. Y. (2019) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2019.2893204 · Cited by 58 · cited 1×
“In addressing this issue, Khan et al. proposed an innovative design that implements a fl exible dual TC and a cross-shaped, 3D RC with a diameter of 8mm 111 .”
A Novel SMA-Based Actuator for a Legged Endoscopic Capsule
Gorini, S., Quirini, M., Menciassi, A., Pernorio, G., Stefanini, C., & Dario, P. (2006) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2006.1639128 · Cited by 58 · cited 1×
“Initial studies have delved into the usage of shape memory alloy (SMA) to convert electrical energy into mechanical deformation, intending to develop a legged capsule robot that mimics crawling creatures 29 – 31 .”
Geng, Y., & Pahlavan, K. (2015) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2015.2483492 · Cited by 55
Utilizing artificial intelligence in endoscopy: a clinician’s guide
Namikawa, K., Hirasawa, T., Yoshio, T., Fujisaki, J., Ozawa, T., Ishihara, S., Aoki, T., Yamada, A., Koike, K., Suzuki, H., et al. (2020) · Expert Review of Gastroenterology & Hepatology · doi:10.1080/17474124.2020.1779058 · Cited by 53
Wireless capsule endoscopy images enhancement via adaptive contrast diffusion
Li, B., & Meng, M. Q. ‐. (2011) · Journal of Visual Communication and Image Representation · doi:10.1016/j.jvcir.2011.10.002 · Cited by 52 · cited 1×
“Improving image quality through processing video signals (such as lesion contours) 81 or integrating depth information for 3D video reconstruction 82 substantially reduces videoscanning timeandmissed detection rates.”
Deep Endoscopic Visual Measurements
Iakovidis, D. K., Dimas, G., Karargyris, A., Bianchi, F., Ciuti, G., & Koulaouzidis, A. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2853987 · Cited by 46 · cited 1×
“Subsequent advancements incorporated arti fi cial neural networks to enhance the VO method, improve geometric inferences, and augment positioning precision 71,72 .”
Detection and Classification of Bleeding Region in WCE Images using Color Feature
Suman, S., Hussin, F. A., Malik, A. S., Pogorelov, K., Riegler, M. A., Ho, S. H., Hilmi, I. N., & Goh, K. (2017) · International Workshop on Content-Based Multimedia Indexing (CBMI) · doi:10.1145/3095713.3095731 · Cited by 45 · cited 1×
“Preliminary data suggest that autonomous detection of these conditions allows AI algorithms to achieve over 95% sensitivity, speci fi city, and accuracy 89 .”
Prasanna, A. P. S., Vivekananthan, V., Khandelwal, G., Alluri, N. R., Raj, N. P. M. J., Anithkumar, M., & Kim, S. (2022) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.1c08030 · Cited by 44 · cited 1×
“Similar to edible batteries, they cannot deliver high power output currently, only suitable to provide energy for monitoring miniature medical devices 21 .”
Gao, J., & Yan, G. (2019) · IEEE Access · doi:10.1109/access.2019.2941562 · Cited by 43 · cited 2×
“Micromotors could serve as power sources and, in conjunction withjigs,enablestableforwardmovementbyswitchingbetweenlinear and expansion anchoring modes 24,25,32 .”
Segmentation of bleeding regions in wireless capsule endoscopy for detection of informative frames
Hajabdollahi, M., Esfandiarpoor, R., Khadivi, P., Soroushmehr, S. M. R., Karimi, N., Najarian, K., & Samavi, S. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101565 · Cited by 42
Monitoring of Drug Release via Intra Body Communication with an Edible Pill
Lamanna, L., Cataldi, P., Friuli, M., Demitri, C., & Caironi, M. (2022) · Advanced Materials Technologies · doi:10.1002/admt.202200731 · Cited by 40 · cited 1×
“A recent study 136 suggests that IBC coupling mode switching can optimize this communication process.”
Active Multiple-Sampling Capsule for Gut Microbiome
Park, S., Lee, H., Kim, D., Kee, H., & Park, S. (2022) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2022.3155534 · Cited by 39 · cited 2×
“In a particular case 158 , an active multiple-sampling capsule facilitated the collection of various intestinal fl uid samples at speci fi c locations using three channels and a diagonally magnetized magnet (Fig.”
Leung, B. H. K., Poon, C. C. Y., Zhang, R., Zheng, Y., Chan, C. K. W., Chiu, P. W. Y., Lau, J. Y. W., & Sung, J. J. �. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2591060 · Cited by 38 · cited 1×
“More-over, in fl atable capsule robots that use magnetic fi elds to trigger chemical reactions have been shown to be viable for weight loss 197 and intestinal hemostasis 198 .”
Ultrasound Capsule Endoscopy With a Mechanically Scanning Micro-ultrasound: A Porcine Study
Qiu, Y., Huang, Y., Zhang, Z., Cox, B. F., Liu, R., Hong, J., Mu, P., Lay, H. S., Cummins, G., Desmulliez, M. P. Y., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.12.003 · Cited by 38 · cited 1×
“Addressing this, researchers introduced a variety of supplementary imaging techniques such as ultrasound 90 , X-ray 91 , and optical coherence tomography 92 , which enable deeper imaging of submucosal tissues.”
Self-citationKim, J., Lee, H.-S., Hoang, M. C., Jeong, S., Kim, J., Lee, C. J., Kang, B., Lee, J., Son, Y., Bang, S., et al. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3120443 · Cited by 37
A screw propelling capsule robot
Liang, H., Guan, Y., Xiao, Z., Hu, C., & Liu, Z. (2011) · IEEE International Conference on Information and Automation (ICIA) · doi:10.1109/icinfa.2011.5949101 · Cited by 37 · cited 1×
“Utilizing the motor ’ s propeller to exert fl uid pressure and generate a reactionary force, it can achieve multi-directional propulsion in the stomach 33 , or high-speed transit in the simulated intestine 34 .”
Design, Fabrication, and Testing of a Novel Ferrofluid Soft Capsule Robot
Hua, D., Liu, X., He, L., Sun, S., Sotelo, M. Á., Li, Z., & Li, W. (2021) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2021.3094213 · Cited by 36
3D reconstruction of small bowel lesions using stereo camera-based capsule endoscopy
Nam, S., Lim, Y. J., Nam, J. H., Lee, H. S., Hwang, Y., Park, J., & Chun, H. J. (2020) · Scientific Reports · doi:10.1038/s41598-020-62935-7 · Cited by 36 · cited 1×
“Improving image quality through processing video signals (such as lesion contours) 81 or integrating depth information for 3D video reconstruction 82 substantially reduces videoscanning timeandmissed detection rates.”
Are Current Advances of Compression Algorithms for Capsule Endoscopy Enough? A Technical Review
Alam, M. W., Hasan, M. M., Mohammed, S. K., Deeba, F., & Wahid, K. A. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2757013 · Cited by 34 · cited 1×
“The breadth of its applications spans various medical procedures, including minimally invasive brain surgery, bronchoscopic lung examination, and magnetic guidewire vascular intervention 3 .”
A novel prepless X-ray imaging capsule for colon cancer screening
Gluck, N., Shpak, B., Brun, R., Rösch, T., Arber, N., & Moshkowitz, M. (2015) · Gut · doi:10.1136/gutjnl-2015-310893 · Cited by 33
Capsule endoscope localization based on visual features
Iakovidis, D. K., Spyrou, E., Diamantis, D. E., & Tsiompanidis, I. (2013) · IEEE International Conference on Bioinformatics and Bioengineering (BIBE) · doi:10.1109/bibe.2013.6701570 · Cited by 33 · cited 1×
“This approach to WCE localization was fi rstproposed by Iakovidis et al. and employed a Java video analysis framework that expedited the development of intelligent video analysis applications 70 .”
Li, P., Kreikemeier‐Bower, C., Xie, W., Kothari, V. M., & Terry, B. S. (2017) · Journal of Biomechanical Engineering · doi:10.1115/1.4036260 · Cited by 31 · cited 1×
“For instance, Li et al. 93 designed a capsule endoscope with two orthogonal pressure sensors to measure contact pressure between the capsule and small intestine, assisting in the detection of potential obstructions.”
At a watershed? Technical developments in wireless capsule endoscopy
Swain, P. C. (2010) · Journal of Digestive Diseases · doi:10.1111/j.1751-2980.2010.00448.x · Cited by 27
A Comparative Evaluation of Control Interfaces for a Robotic-Aided Endoscopic Capsule Platform
Ciuti, G., Lucarini, G., Valdastri, P., Arezzo, A., Menciassi, A., Morino, M., & Dario, P. (2011) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2177173 · Cited by 27 · cited 1×
“Statistical analysis of control parameters con fi rmed that TO control surpasses HRC control in reliability, rendering it better suited for conducting steady robot-assisted capsule endoscopic surgery 180 .”
On Reciprocally Rotating Magnetic Actuation of a Robotic Capsule in Unknown Tubular Environments
Xu, Y., Li, K., Zhao, Z., & Meng, M. Q. ‐. (2021) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2021.3123407 · Cited by 26 · cited 1×
“A recent study by Xu et al. 118 introduced reciprocally rotating magnetic actuation (RRMA) which utilizes an external rotating magnet and a smooth capsule to effectively mitigate these risks (Fig.”
Design of a magnetic actuation system for a microbiota-collection ingestible capsule
Finocchiaro, M., Giosuè, C., Drago, G., Cibella, F., Menciassi, A., Sprovieri, M., & Ciuti, G. (2021) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra48506.2021.9561142 · Cited by 26
Intra and inter‐observer agreement on polyp detection in colon capsule endoscopy evaluations
Buijs, M. M., Krøijer, R., Kobæk-Larsen, M., et al. (2018) · United European Gastroenterology Journal · doi:10.1177/2050640618798182 · Cited by 25
Characteristic evaluation of a magnetic-actuated microrobot in pipe with screw jet motion
Wang, Z., Guo, S., Fu, Q., & Guo, J. J. (2018) · Microsystem Technologies · doi:10.1007/s00542-018-4000-5 · Cited by 25 · cited 1×
“Utilizing a 3D HC alongside the capsule ’ s rotary screw jet con fi g-uration bolsters its locomotive performance 120 .”
Suspected Blood Indicator to Identify Active Gastrointestinal Bleeding: A Prospective Validation
Han, S. S., Fahed, J., & Cave, D. R. (2018) · Gastroenterology Research · doi:10.14740/gr949w · Cited by 24 · cited 1×
“AI algorithms, such as “ express view “ 83 and “ suspected blood indicator “ 84 , tailored for WCE, are now utilized in clinical practice.”
Towards a Miniaturized 3D Receiver WPT System for Capsule Endoscopy
Khan, S. R., & Desmulliez, M. P. Y. (2019) · Micromachines · doi:10.3390/mi10080545 · Cited by 22 · cited 7×
“However, it is dif fi cult to improve PTE and RPS by increasing the value of k in the actual application of WCE.”
InfluentialClinicians’ Guide to Artificial Intelligence in Colon Capsule Endoscopy—Technology Made Simple
Lei, I. I., Nia, G. J., White, E., Wenzek, H. R., Seguí, S., Watson, A. J. M., Koulaouzidis, A., & Arasaradnam, R. P. (2023) · Diagnostics · doi:10.3390/diagnostics13061038 · Cited by 22 · cited 1×
“Never-theless, data sourced from a singular agency or sampled from a restricted geographical region may inadvertently introduce bias and compromise generalizability 177 .”
Application of OCT in the Gastrointestinal Tract
Samel, N. S., & Mashimo, H. L. (2019) · Applied Sciences · doi:10.3390/app9152991 · Cited by 20
MagnetOFuse: A Hybrid Tracking Algorithm for Wireless Capsule Endoscopy Within the GI Track
Vedaei, S. S., & Wahid, K. A. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3204103 · Cited by 19 · cited 3×
“In literature 75 , researchers introduced a hybrid positioning method known as “ MagnetOFuse ” , which integrates both magnetic and visual aspects.”
Hakimian, S., Raines, D. L., Reed, G. W., Hanscom, M. H., Stefaniwsky, L. R., Petersile, M., Rau, P., Foley, A., & Cave, D. R. (2021) · JAMA Network Open · doi:10.1001/jamanetworkopen.2021.18796 · Cited by 17
Pichon, L. (2020) · Journal of Electromagnetic Waves and Applications · doi:10.1080/09205071.2020.1799870 · Cited by 16 · cited 1×
“There are two types of WPT technology, distinguishable by the coupling region between the transmitting and receiving antennas: near-fi eld transmission (non-radiative) and far-fi eld transmission (radiative) 22 .”
Zhuang, H., Wang, W., Zhao, K., Fei, Q., & Yan, G. (2022) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.2399 · Cited by 15 · cited 2×
“Inaddition,someprovenSAR optimization methods include increasing the gap between the human body and the coil 108 .”
Wang, Y., Yoo, S., Braun, J.-M., & Nadimi, E. S. (2021) · Journal of Real-Time Image Processing · doi:10.1007/s11554-021-01126-7 · Cited by 14
A Novel Cyber Physical System for 3-D Imaging of the Small Intestine In Vivo
Pahlavan, K., Geng, Y., Cave, D. R., Bao, G., Mi, L., Agu, E., Karellas, A., Sayrafian, K., & Tarokh, V. (2015) · IEEE Access · doi:10.1109/access.2015.2508003 · Cited by 14 · cited 1×
“…Nature Communications| (2024) 15:4597 Aiming for a complementary advantage, researchers have endeavored to integrate video positioning with other positioning technologies,includingmagnet/video 74,75 (Fig.2e)andRF/videohybrid positioning 76,77 , without incorporating additional sensor components.”
Diagnosing Colorectal Polyps in the Wild with Capsule Networks
LaLonde, R., Kandel, P., Spampinato, C., Wallace, M. B., & Bağcı, U. (2020) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi45749.2020.9098411 · Cited by 14 · cited 1×
“Furthermore, a novel capsule network architecture (D-Caps) was introduced to enhance the feasibility of opticalbiopsy for colorectal polyps in WCE 147 .”
Wang, C., Luo, Z., Liu, X., Bai, J., & Liao, G. (2018) · Journal of Healthcare Engineering · doi:10.1155/2018/3090341 · Cited by 13 · cited 1×
“Topographical video segmentation leverages various image characteristics such as color, texture, and movement to divide fi lmed frames into multiple successive organ area segments, thereby facilitating accurate positioning 66 – 68 .”
High-Efficiency Wireless Power Transfer System for Capsule Endoscope
Miah, M. S., Jayathurathnage, P. K. S., Icheln, C., Haneda, K., & Tretyakov, S. (2019) · International Symposium on Medical Information and Communication Technology · doi:10.1109/ismict.2019.8743685 · Cited by 11 · cited 2×
“Miah et al. 106 .”
Distilling the knowledge in CNN for WCE screening tool
Garbay, T., Chuquimia, O., Pinna, A., Sahbi, H., Dray, X., & Granado, B. (2019) · Conference on Design and Architectures for Signal and Image Processing · doi:10.1109/dasip48288.2019.9049201 · Cited by 7
A Magnetically Controlled Capsule Robot for Obesity Treatment with Intra-gastric Balloon
Mao, Y., Guo, J. J., Guo, S., Fu, Q., & Mo, B. (2022) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma54519.2022.9856144 · Cited by 5 · cited 1×
“More-over, in fl atable capsule robots that use magnetic fi elds to trigger chemical reactions have been shown to be viable for weight loss 197 and intestinal hemostasis 198 .”
Metadata
- Authors
- Cao, Q., Deng, R., Pan, Y., Liu, R., Chen, Y., Gong, G., Zou, J., Yang, H., & Han, D.
- Venue
- Nature Communications
- Published
- 2024-05-30
- Volume
- 15
- Issue
- 1
- Pages
- 4597-4597
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W4399179612
- Cited by
- 165
- References
- 136
- FWCI
- 17.33
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.