Microneedle patch for the ultrasensitive quantification of protein biomarkers in interstitial fluid
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
The detection and quantification of protein biomarkers in interstitial fluid is hampered by challenges in its sampling and analysis. Here we report the use of a microneedle patch for fast in vivo sampling and on-needle quantification of target protein biomarkers in interstitial fluid. We used plasmonic fluor—an ultrabright fluorescent label—to improve the limit of detection of various interstitial fluid protein biomarkers by nearly 800-fold compared with conventional fluorophores, and a magnetic backing layer to implement conventional immunoassay procedures on the patch and thus improve measurement consistency. We used the microneedle patch in mice for minimally invasive evaluation of the efficiency of a cocaine vaccine, for longitudinal monitoring of the levels of inflammatory biomarkers, and for efficient sampling of the calvarial periosteum—a challenging site for biomarker detection—and the quantification of its levels of the matricellular protein periostin, which cannot be accurately inferred from blood or other systemic biofluids. Microneedle patches for the minimally invasive collection and analysis of biomarkers in interstitial fluid might facilitate point-of-care diagnostics and longitudinal monitoring. A microneedle patch that samples and quantifies target protein biomarkers in interstitial fluid allows for longitudinal monitoring of the levels of a range of disease-relevant biomarkers, as shown in live mice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gold nanostructures: engineering their plasmonic properties for biomedical applications
Hu, M., Chen, J., Li, Z.-Y., Au, L., Hartland, G. V., Li, X., Marquez, M., & Xia, Y. (2006) · Chemical Society Reviews · doi:10.1039/b517615h · Cited by 1,756
Davis, S. P., Landis, B. J., Adams, Z. H., Allen, M. G., & Prausnitz, M. R. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.010 · Cited by 934
Gold Nanoparticles Quench Fluorescence by Phase Induced Radiative Rate Suppression
Dulkeith, E., Ringler, M., Klar, T. A., Feldmann, J., Muñoz Javier, A., & Parak, W. J. (2005) · Nano Letters · doi:10.1021/nl0480969 · Cited by 768
Accessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758
Lee, K.-S., & El-Sayed, M. A. (2005) · The Journal of Physical Chemistry B · doi:10.1021/jp054385p · Cited by 618
Skeletal Cell Fate Decisions Within Periosteum and Bone Marrow During Bone Regeneration
Colnot, C. (2009) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.081003 · Cited by 588
Chang, H., Zheng, M., Yu, X., Than, A., Seeni, R. Z., Kang, R., Tian, J., Khanh, D. P., Liu, L., Chen, P., et al. (2017) · Advanced Materials · doi:10.1002/adma.201702243 · Cited by 462
Self-citationSuction Blister Device for Separation of Viable Epidermis from Dermis*
Kiistala, U. (1968) · Journal of Investigative Dermatology · doi:10.1038/jid.1968.15 · Cited by 448
Acute Inflammatory Response to Endotoxin in Mice and Humans
Copeland, S., Warren, H. S., Lowry, S. F., Calvano, S. E., & Remick, D. (2005) · Clinical and Vaccine Immunology · doi:10.1128/cdli.12.1.60-67.2005 · Cited by 436
Mechanisms of sampling interstitial fluid from skin using a microneedle patch
Samant, P. P., & Prausnitz, M. R. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1716772115 · Cited by 363
The periosteum: what is it, where is it, and what mimics it in its absence?
Dwek, J. R. (2010) · Skeletal Radiology · doi:10.1007/s00256-009-0849-9 · Cited by 339
Martell, B. A., Orson, F. M., Poling, J., Mitchell, E., Rossen, R. D., Gardner, T., & Kosten, T. R. (2009) · Archives of General Psychiatry · doi:10.1001/archgenpsychiatry.2009.128 · Cited by 263
A Hydrogel Microneedle Patch for Point‐of‐Care Testing Based on Skin Interstitial Fluid
He, R., Niu, Y., Li, Z., Li, A., Yang, H., Xu, F., & Li, F. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901201 · Cited by 257
Encoded Microneedle Arrays for Detection of Skin Interstitial Fluid Biomarkers
Zhang, X., Chen, G., Bian, F., Cai, L., & Zhao, Y. (2019) · Advanced Materials · doi:10.1002/adma.201902825 · Cited by 252
Self-citationThe treatment of cocaine use disorder
Kampman, K. M. (2019) · Science Advances · doi:10.1126/sciadv.aax1532 · Cited by 250
Al Sulaiman, D., Chang, J. Y. H., Bennett, N. R., Topouzi, H., Higgins, C. A., Irvine, D. J., & Ladame, S. (2019) · ACS Nano · doi:10.1021/acsnano.9b04783 · Cited by 233
Monteiro-Riviere, N. A., Bristol, D. G., Manning, T. O., Rogers, R. A., & Riviere, J. E. (1990) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12505567 · Cited by 231
Luan, J., Seth, A., Gupta, R., Wang, Z., Rathi, P., Cao, S., Gholami Derami, H., Tang, R., Xu, B., Achilefu, S., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0547-4 · Cited by 201
Self-citationTran, B. Q., Miller, P. R., Taylor, R. M., Boyd, G., Mach, P. M., Rosenzweig, C. N., Baca, J. T., Polsky, R., & Glaros, T. (2018) · Journal of Proteome Research · doi:10.1021/acs.jproteome.7b00642 · Cited by 198
The multiple facets of periostin in bone metabolism
Merle, B., & Garnero, P. (2012) · Osteoporosis International · doi:10.1007/s00198-011-1892-7 · Cited by 190
Colloidally Stable and Surfactant-Free Protein-Coated Gold Nanorods in Biological Media
Tebbe, M., Kuttner, C., Männel, M., Fery, A., & Chanana, M. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b00335 · Cited by 179
Davidson, A., Al-Qallaf, B., & Das, D. B. (2008) · Chemical Engineering Research and Design · doi:10.1016/j.cherd.2008.06.002 · Cited by 174
Azide-Derivatized Gold Nanorods: Functional Materials for “Click” Chemistry
Gole, A., & Murphy, C. J. (2008) · Langmuir · doi:10.1021/la7026303 · Cited by 173
Bonnet, N., Garnero, P., & Ferrari, S. (2016) · Molecular and Cellular Endocrinology · doi:10.1016/j.mce.2015.12.014 · Cited by 162
McHugh, K. J., Jing, L., Severt, S. Y., Cruz, M., Sarmadi, M., Jayawardena, H. S. N., Perkinson, C. F., Larusson, F., Rose, S., Tomasic, S. L., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aay7162 · Cited by 145
Novel pharmacotherapeutic treatments for cocaine addiction
Shorter, D. I., & Kosten, T. R. (2011) · BMC Medicine · doi:10.1186/1741-7015-9-119 · Cited by 120
Suction blister fluid as potential body fluid for biomarker proteins
Kool, J., Reubsaet, L., Wesseldijk, F., Maravilha, R. T., Pinkse, M. W. H., D’Santos, C. S., van Hilten, J. J., Zijlstra, F. J., & Heck, A. J. R. (2007) · PROTEOMICS · doi:10.1002/pmic.200600938 · Cited by 119
Morishita, R. (2011) · International Journal of Molecular Medicine · doi:10.3892/ijmm.2011.712 · Cited by 114
Transdermal colorimetric patch for hyperglycemia sensing in diabetic mice
Wang, Z., Li, H., Wang, J., Chen, Z., Chen, G., Wen, D., Chan, A., & Gu, Z. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.119782 · Cited by 110
Self-citationOpen Flow Microperfusion as a Dermal Pharmacokinetic Approach to Evaluate Topical Bioequivalence
Bodenlenz, M., Tiffner, K., Raml, R., Augustin, T., Dragatin, C., Birngruber, T., Schimek, D., Schwagerle, G., Pieber, T. R., Raney, S. G., et al. (2016) · Clinical Pharmacokinetics · doi:10.1007/s40262-016-0442-z · Cited by 104
Hong, Y., Chao, W., Chen, M., & Lin, B. (2009) · Journal of Biomedical Science · doi:10.1186/1423-0127-16-64 · Cited by 101
Microdialysis methodology for the measurement of dermal interstitial fluid in humans
KROGSTAD, A. L., JANSSON, P.-A., GISSLÉN, P., & LÖNNROTH, P. (1996) · British Journal of Dermatology · doi:10.1046/j.1365-2133.1996.d01-893.x · Cited by 98
Müller, A. C., Breitwieser, F. P., Fischer, H., Schuster, C., Brandt, O., Colinge, J., Superti‐Furga, G., Stingl, G., Elbe‐Bürger, A., & Bennett, K. L. (2012) · Journal of Proteome Research · doi:10.1021/pr3002035 · Cited by 86
Tumor interstitial fluid — A treasure trove of cancer biomarkers
Gromov, P., Gromova, I., Olsen, C. J., Wielenga, V. T., Talman, M.-L., Serizawa, R., & Moreira, J. M. A. (2013) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2013.01.013 · Cited by 81
Muller, D. A., Corrie, S. R., Coffey, J. W., Young, P. R., & Kendall, M. A. F. (2012) · Analytical Chemistry · doi:10.1021/ac2034387 · Cited by 75
Yang, B., Fang, X., & Kong, J. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b12244 · Cited by 75
Sakai, D., Kii, I., Nakagawa, K., Matsumoto, H., Takahashi, M., Yoshida, S., Hosoya, T., Takakuda, K., & Kudō, A. (2011) · PLoS ONE · doi:10.1371/journal.pone.0024847 · Cited by 52
Coffey, J. W., Meliga, S. C., Corrie, S. R., & Kendall, M. A. F. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.015 · Cited by 45
Coffey, J. W., Corrie, S. R., & Kendall, M. A. F. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.03.039 · Cited by 44
Taylor, R. M., Miller, P. R., Ebrahimi, P., Polsky, R., & Baca, J. T. (2018) · Laboratory Animals · doi:10.1177/0023677218758801 · Cited by 44
Nedrebø, T., Reed, R. K., Jonsson, R., Berg, A., & Wiig, H. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2003.057216 · Cited by 42
Anti-cocaine vaccine development
Kinsey, B. M., Kosten, T. R., & Orson, F. M. (2010) · Expert Review of Vaccines · doi:10.1586/erv.10.102 · Cited by 42
Overcoming Immune Dysregulation with Immunoengineered Nanobiomaterials
Scott, E. A., Karabin, N. B., & Augsornworawat, P. (2017) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071516-044603 · Cited by 39
Hapten-specific naïve B cells are biomarkers of vaccine efficacy against drugs of abuse
Taylor, J. J., Laudenbach, M., Tucker, A. M., Jenkins, M. K., & Pravetoni, M. (2014) · Journal of Immunological Methods · doi:10.1016/j.jim.2014.01.010 · Cited by 29
Cai, Y., Zhu, J., He, J., Yang, W. L., Ma, C., Xiong, F., Li, F., Chen, W., & Chen, P. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801478 · Cited by 26
Cited by
Wearable chemical sensors for biomarker discovery in the omics era
Sempionatto, J. R., Lasalde-Ramírez, J. A., Mahato, K., Wang, J., & Gao, W. (2022) · Nature Reviews Chemistry · doi:10.1038/s41570-022-00439-w · Cited by 613
Greenificated Molecularly Imprinted Materials for Advanced Applications
Ostovan, A., Arabi, M., Wang, Y., Li, J., Li, B., Wang, X., & Chen, L. (2022) · Advanced Materials · doi:10.1002/adma.202203154 · Cited by 442
Self-citationOpportunities and challenges in the diagnostic utility of dermal interstitial fluid
Friedel, M., Thompson, I. A. P., Kasting, G., Polsky, R., Cunningham, D., Soh, H. T., & Heikenfeld, J. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00998-9 · Cited by 360
SARS-CoV-2 breakthrough infections in vaccinated individuals: measurement, causes and impact
Lipsitch, M., Krammer, F., Regev-Yochay, G., Lustig, Y., & Balicer, R. D. (2022) · Nature Reviews Immunology · doi:10.1038/s41577-021-00662-4 · Cited by 336
Soft wearable devices for deep-tissue sensing
Lin, M., Hu, H., Zhou, S., & Xu, S. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00427-y · Cited by 334
Metadata
- Authors
- Wang, Z., Luan, J., Seth, A., Liu, L., You, M., Gupta, P., Rathi, P., Wang, Y., Cao, S., Jiang, Q., Zhang, X., Gupta, R., Zhou, Q., Morrissey, J. J., Scheller, E. L., Rudra, J. S., & Singamaneni, S.
- Venue
- Nature Biomedical Engineering
- Published
- 2021-01-22
- Volume
- 5
- Issue
- 1
- Pages
- 64-76
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W3125908988
- Cited by
- 386
- References
- 45
- FWCI
- 20.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.