Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays
The DOI matches its Crossref record; 75 of the 76 references it cites were found in a registry or an index.
Abstract
Stretchable wearable devices for the continuous monitoring of physiological signals from deep tissues are constrained by the depth of signal penetration and by difficulties in resolving signals from specific tissues. Here, we report the development and testing of a prototype skin-conformal ultrasonic phased array for the monitoring of haemodynamic signals from tissues up to 14 cm beneath the skin. The device allows for active focusing and steering of ultrasound beams over a range of incident angles so as to target regions of interest. In healthy volunteers, we show that the phased array can be used to monitor Doppler spectra from cardiac tissues, record central blood flow waveforms and estimate cerebral blood supply in real time. Stretchable and conformal skin-worn ultrasonic phased arrays may open up opportunities for wearable diagnostics.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Other mechanisms of flexible health monitoring in rehabilitation, like optoelectronic[263,264] and ultrasound[265,266] devices, can also be applied to heartbeat, pulse oximetry, blood pressure, and other on-body measurements.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [265]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Materials and Mechanics for Stretchable Electronics
Rogers, J. A., Someya, T., & Huang, Y. (2010) · Science · doi:10.1126/science.1182383 · Cited by 5,042
Self-citationWearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Ommen, S. R., Nishimura, R. A., Appleton, C. P., Miller, F. A., Oh, J. K., Redfield, M. M., & Tajik, A. J. (2000) · Circulation · doi:10.1161/01.cir.102.15.1788 · Cited by 2,790
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884
Prognosis in Acute Organ-System Failure
KNAUS, W. A., DRAPER, E. A., WAGNER, D. P., & ZIMMERMAN, J. E. (1985) · Annals of Surgery · doi:10.1097/00000658-198512000-00004 · Cited by 1,225
The Assessment of Endothelial Function: From Research Into Clinical Practice
Flammer, A. J., Anderson, T., Celermajer, D. S., Creager, M. A., Deanfield, J., Ganz, P., Hamburg, N. M., Lüscher, T. F., Shechter, M., Taddei, S., et al. (2012) · Circulation · doi:10.1161/circulationaha.112.093245 · Cited by 1,153
Speckle in ultrasound B-mode scans
Burckhardt, C. B. (1978) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1978.30978 · Cited by 1,066
Cope, M., & Delpy, D. T. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447083 · Cited by 1,065
Research works printed but not linked: 1
- J. Lee, H.-S. & Sodini, C. G. in Intracranial Pressure & Neuromonitoring XVI 111–114 (Springer, 2018).
Cited by
Items 101–200 of 274
Continuous Artery Monitoring Using a Flexible and Wearable Single-Element Ultrasonic Sensor
Steinberg, S., Huang, A., Ono, Y., & Rajan, S. (2022) · IEEE Instrumentation & Measurement Magazine · doi:10.1109/mim.2022.9693453 · Cited by 25
Rey, A. B. A., Seabra, A. C. G., & Stieglitz, T. (2024) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2024.3410399 · Cited by 34
“Wang et al. [92] validate the developed stretchable sensor by calculating the biased and precision error of peak systolicvelocity(PSV)andEDVandrevealingthemcomparable tothecommercialdevice.”
InfluentialA Stretchable and Wearable Ultrasonic Transducer Array for Bladder Volume Monitoring Application
Pu, C., Fu, B., Guo, L., Xu, H., & Peng, C. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3382244 · Cited by 24
“The stretchability is primarily achieved from the stretchable interconnection, such as Cu/PI serpentine-based electrodes [23], [24], [25], [26], [27], [28] and gallium-indium eutectic liquid metal [29], along with a stretchable substrate, such as silicone elastomer (Eco-flex 0030).”
BackgroundLiu, Z., Tang, C., Han, N., Jiang, Z., Liang, X., Wang, S., Hu, Q., Xiong, C., Yao, S., Wang, Z., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-58056-2 · Cited by 33
Implantable bioresorbable electronic systems for sustainable precision medicine
Corsi, M., Bellotti, E., Surdo, S., & Barillaro, G. (2025) · Nature Reviews Electrical Engineering · doi:10.1038/s44287-025-00190-6 · Cited by 34
“Ultrasound-readable sensors 70 facilitate non-invasive, deep-tissue monitoring and reduce the risk of infection, whereas optical sensors 71 offer precise, wireless, local monitoring of analytes at the transdermal level.”
A Flexible Ultrasound Array for Local Pulse Wave Velocity Monitoring
Xu, L., Wang, P., Xia, P., Wu, P., Chen, X., Du, L., Liu, J., Xue, N., & Fang, Z. (2022) · Biosensors · doi:10.3390/bios12070479 · Cited by 26
“Some miniaturized ultrasound probes [25–27] and stretchable ultrasound wearable devices have been developed for blood pressure and blood flow velocity monitoring [24,28,29].”
BackgroundLiu, H., Fan, J., Lin, X., Lin, K., Wang, S., Liu, S., Wang, F., & Song, J. (2024) · npj Flexible Electronics · doi:10.1038/s41528-024-00354-8 · Cited by 23
Barriers to translating continuous monitoring technologies for preventative medicine
Chen, J., Jastrzebska‐Perfect, P., Chai, P. R., Say, M. G., Tu, J., Gao, W. F., Halperin, F., Korzenik, J., Huang, H., Katabi, D., et al. (2025) · Nature Biomedical Engineering · doi:10.1038/s41551-025-01520-7 · Cited by 36
“The sensors can capture central blood pressure 213 , deep-tissue haemody-namics and cardiac performance 214,215 and organ-volume changes 216 .”
Continuous monitoring with a permanently installed high-resolution ultrasonic phased array
Sun, X., Croxford, A. J., & Drinkwater, B. W. (2023) · Structural Health Monitoring · doi:10.1177/14759217231152413 · Cited by 23
Deep-Learning-Based Analysis of Electronic Skin Sensing Data
Guo, Y., Sun, X., Li, L., Shi, Y., Cheng, W. M., & Pan, L. (2025) · Sensors · doi:10.3390/s25051615 · Cited by 27
“Existing cuffless blood pressure monitoring methods, which use acoustic, pressure, or optical modalities, face challenges in simultaneously achieving accurate blood pressure signal capture while maintaining good skin compatibility [161].”
Krings, E. J., Hage, B. D., Truong, S. L., Reeser, K. A., Fox, E. L., Snyder, M. G., Walker, Q., Bashford, G. R., & Markvicka, E. J. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202308954 · Cited by 24
Review on Wearable System for Positioning Ultrasound Scanner
Li, L., Zhao, L., Hassan, R., & Ren, H. (2023) · Machines · doi:10.3390/machines11030325 · Cited by 22
Fabric‐Based Ultrasonic Sensor with Integrated Piezoelectric Composite for Blood Pressure Monitoring
Li, B., Wang, T., Luo, D., Peng, P., Wang, Y., Liu, L., Wang, H., & Liu, H. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202201814 · Cited by 23
Active acoustic field modulation of ultrasonic transducers with flexible composites
Hou, C., Li, Z., Fei, C., Li, Y., Wang, Y., Zhao, T., Quan, Y., Chen, D., Li, X., Bao, W., et al. (2023) · Communications Physics · doi:10.1038/s42005-023-01361-3 · Cited by 21
Acoustofluidic tweezers via ring resonance
Xu, X., Jin, K., Yang, K., Zhong, R., Liu, M., Collyer, W., Jain, S., Chen, Y., Xia, J., Li, J., et al. (2024) · Science Advances · doi:10.1126/sciadv.ads2654 · Cited by 19
“Hence, this technology has found diverse and substantial applications in medical diagnostics ( 25 , 26 ), bioanalytical chemistry ( 10 , 27 – 33 ), and materials science ( 34 – 37 ).”
Self-citationSilicon nanocolumn-based disposable and flexible ultrasound patches
Kang, D.-H., Cho, S., Kim, H. Y., Shim, S., Kim, D. H., Jeong, B., Lee, Y. S., Park, E., Lee, W., Kim, H., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-61903-x · Cited by 23
“Stretchable ultrasound probes, while relatively thin at 1 mm, suffer from poor lateral resolution of 2 mm due to wide pitch and kerf 4,13 .”
Nanosensor Technologies and the Digital Transformation of Healthcare
Udoh, E., Hermel, M. H., Bharmal, M., Nayak, A., Patel, S., Butlin, M., & Bhavnani, S. P. (2023) · Personalized Medicine · doi:10.2217/pme-2022-0065 · Cited by 21
Bendable Phased-Array Ultrasound Transducer for Imaging on Curved Surfaces
Yin, S., Zhang, H., Shi, F., Chen, Y., Zhong, C., Li, R., & Su, Y. (2025) · ACS Nano · doi:10.1021/acsnano.4c16028 · Cited by 17
Self-citationBioengineered nanomaterials for dynamic diagnostics in vivo
Wu, J., Zhou, X., Tsang, C. Y., Mei, Q., & Zhang, Y. (2025) · Chemical Society Reviews · doi:10.1039/d5cs00136f · Cited by 20
Wearable ultrasound for continuous deep-tissue monitoring
Kenny, J. S. (2024) · Nature Biotechnology · doi:10.1038/s41587-023-02098-8 · Cited by 18
Bone Fracture Healing under the Intervention of a Stretchable Ultrasound Array
Liu, H., Ding, S., Lin, X., Wang, S., Wang, Y., Feng, Z., & Song, J. (2024) · ACS Nano · doi:10.1021/acsnano.4c02426 · Cited by 16
Liao, Z., Golparvar, A. J., Bathaei, M. J., Cardoso, F. A., & Boutry, C. M. (2025) · Advanced Science · doi:10.1002/advs.202509934 · Cited by 21
Zhang, Z., Zhang, Z., Mei, D., & Wang, Y. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116202 · Cited by 17
Self-citationDynamic and High‐Precision Sound Manipulation by Acoustic Metamaterial‐Empowered Phased Arrays
Chen, A., Xia, Y., Chen, Z., Su, H., Liu, J., Yang, Y., Zhu, X., Liang, B., & Cheng, J. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202425833 · Cited by 15
Fei, G., Zhang, S., Li, Y., Peng, M., Tang, Z., Gu, X., Li, X., Zhang, K., Xie, J., Ni, Y., et al. (2025) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2025.100990 · Cited by 18
Towards an Open, Flexible, Wearable Ultrasound Probe for Musculoskeletal Monitoring
Vostrikov, S., Cossettini, A., Vogt, C., Leitner, C., Magno, M., & Luca Benini, C. (2021) · IEEE International Ultrasonics Symposium · doi:10.1109/ius52206.2021.9593910 · Cited by 15
“To increase the wearability of piezo-ceramic US transducers, recent works also showed skin conformable, epidermal interfaces [9] for unobtrusive data acquisitions.”
BackgroundZhou, J., Qu, M., Liu, W., Wang, Y., Zhang, G., Zheng, Y., & Xie, J. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3514878 · Cited by 20
“Various wearable sensors, such as those based on photoplethysmography (PPG) [20], [21], piezoelectric [22], [23], [24], ultrasonic [25], [26], and bioimpedance [27], [28] mechanisms, have been developed to acquire various cardiovascular physiological signals, such as the optical reflectance of…”
A weavable and wearable polymer ultrasonic transducer with a large bandwidth
Zou, J., Guo, X., Wu, J., Xu, D., Xu, K., Chen, P., Ta, D., & Peng, H. (2024) · Science China Materials · doi:10.1007/s40843-024-2945-7 · Cited by 17
“Efforts to improve flexibility have been explored, including the design of island-bridge-structure piezoelectric ceramics on flexible substrates such as polyimide (PI) or elastomer [10,27–29].”
High-Frequency Wearable Ultrasound Array Belt for Small Animal Echocardiography
Zeng, Y., Sun, X. S., Zhang, J., Chang, C.-F., Liu, B., Gong, C., Ji, J., Zhang, B. Z., Wang, Y., Ren, M. X., et al. (2024) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2024.3492197 · Cited by 14
Self-citationTranscranial Ultrasound Imaging With Decomposition Descent Learning-Based Full Waveform Inversion
Tong, J., Wang, X., Ren, J., Lin, M., Li, J., Sun, H., Yin, F., Liang, L., & Liu, Y. (2022) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2022.3217512 · Cited by 15
“Later, this design is revised to enable continuous monitoring of hemodynamic signals from tissues deep beneath the skin [5].”
Self-citationZhang, Z., Wang, Y., Mei, D., & Jin, J. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3277988 · Cited by 14
“arrays [31], this detection method is highly efficient and, simple, only utilizes a few elements, making it a viable”
BackgroundMethodSelf-citationFang, M., Yu, R., Meng, F., Liu, X., Tang, N., Yuan, M., Wang, K., & Guo, J. (2025) · ACS Sensors · doi:10.1021/acssensors.5c01767 · Cited by 17
Li, C., Wang, H., Song, Z., Zhang, W., Pan, Y., Zhao, Z., Qiu, C., Yin, K., Han, M., Wang, A. B., et al. (2025) · Science Advances · doi:10.1126/sciadv.ady0534 · Cited by 16
Self-citationYin, F., Hongsen, N., Shin, Y. K., Li, Y., Kim, E., & Kim, N. (2023) · Nano Energy · doi:10.1016/j.nanoen.2023.109039 · Cited by 13
Acoustoelectric materials & devices in biomedicine
Zhang, X., Zhang, Y., Zhang, J., Shang, J., Lin, L., Liu, Q., & An, Q. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.149314 · Cited by 13
Tian, Y., Yang, K., Wang, Y., Wang, J., Carlini, A. S., Zhang, Z., Deng, Y., Tan, J., Peng, L., Yu, B., et al. (2024) · npj Flexible Electronics · doi:10.1038/s41528-024-00342-y · Cited by 17
“However, limited by the huge amount of data and complex processing process, the majority of these devices are unable to operate independently of large-scale equipment situated in the background 15 – 18 .”
Self-citationShen, Z., Li, J., Hu, H., Du, C., Ding, X., Pan, T., & Yu, X. (2025) · AI Sensors · doi:10.3390/aisens1020008 · Cited by 13
“( e ) A prototype skin-conformal ultrasound phased array for monitoring hemodynamic signals in deep subcutaneous tissue [35].”
Self-citationRecent Advances in Materials, Designs and Applications of Skin Electronics
Yao, K., Yang, Y., Wu, P., Zhao, G., Wang, L., & Yu, X. (2022) · IEEE Open Journal of Nanotechnology · doi:10.1109/ojnano.2022.3218960 · Cited by 13
“rays which can achieve continuous monitoring of deep-tissue hemodynamics [82].”
BackgroundA stretchable cardiac ultrasound imager: a milestone in wearable bioimaging
Zhong, B., & Wang, L. (2023) · 中国科学通报:英文版 · doi:10.1016/j.scib.2023.04.002 · Cited by 12
“In particular, by utilizing the phased-array technique, wearable probes are capable of monitoring high-resolution ultrasound signals from deeper and wider positions, including the heart [4,5].”
Ultrasonic flexible array for non-destructive testing of complex curved surfaces
Sun, Y., Quan, Y., Fei, C., Xue, X., Zhang, J., Wang, Y., Sun, X., Li, Z., Zhao, T., Xing, G., et al. (2024) · Ceramics International · doi:10.1016/j.ceramint.2024.03.069 · Cited by 13
Soft wearable electronics for evaluation of biological tissue mechanics
Lu, Y., Ma, L., Zhang, H., Mei, Y., Xiong, Z., & Song, E. (2024) · Soft Science · doi:10.20517/ss.2024.29 · Cited by 17
Superior lead-free piezoceramics for wearable multimodal ultrasound imaging arrays
Xue, H., Huang, X., Sun, X. S., Wu, K., Tan, Z., Fan, H., Sun, J., Jiang, L., & Wu, J. (2025) · Nature Communications · doi:10.1038/s41467-025-66913-3 · Cited by 19
“Theresulting1 – 3piezo-element, featuring high-performance piezo-micropillars embedded within the passive epoxy matrix, offers substantial advantages over bulk ceramics, including reduced acoustic impedance and enhanced longitudinal-mode electromechanical coupling 1,3,4,9 .”
Deconvolution based on sparsity and continuity improves the quality of ultrasound image
Li, X., Zhang, X., Fan, C., Chen, Y., Zheng, J., Gao, J., & Shen, Y. (2023) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2023.107860 · Cited by 14
Self-citationLopez, M. V., Linares-Barranco, B., Lee, J., Erfanijazi, H., Patiño-Saucedo, A., Sifalakis, M., Catthoor, F., & Myny, K. (2024) · Communications Engineering · doi:10.1038/s44172-024-00248-7 · Cited by 13
“…of leakage of a single-gate, n-type only IGZO TFT 0.8 µm node from the foundry Pragmatic 4 to design a neuron capable of integrating information over a range of time-scales 7 orders of magnitude wide based on the excitation speed of its synapse and adjustable by means of a single bias voltage.”
InfluentialAdhesive bioelectronics for closed-loop therapy
Jung, H., Lee, H., Shin, M., & Son, D. (2025) · Med-X · doi:10.1007/s44258-025-00055-5 · Cited by 20
“However, the piezoelectric element placed over the stretch-able substrate gives rise to limitations, such as unpredictable spatial and angular positioning during deformation and imaging for short durations [189].”
Acoustic percolation switches enable targeted drug delivery controlled by diagnostic ultrasound
Abundo, M. P., Tifrea, A. T., Buss, M. T., Barturen‐Larrea, P., Jin, Z., Malounda, D., & Shapiro, M. G. (2025) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2423078122 · Cited by 15
Advances in mechanically active materials for soft wearable electronics
Wu, K., He, W. H., Zhong, R., Nie, Z., Lin, X., & Han, M. (2025) · Materials Horizons · doi:10.1039/d5mh00563a · Cited by 15
Tang, Z., Wu, Y., Qu, M., Xu, J., Liu, W., Zheng, Y., & Xie, J. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202505131 · Cited by 10
Seeing inside the Body Using Wearable Sensing and Imaging Technologies
Kim, S., Han, S., Park, S., & Koo, J. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202502480 · Cited by 13
Chen, H.-J., Chuang, H., Xu, G., Chen, C., Su, W., & Huang, C. (2024) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2023.3348472 · Cited by 9
“D array transducer [35], [36], [37], [38].”
MethodSpongy Ag Foam for Soft and Stretchable Strain Gauges
Hong, S., Zhang, H., Lee, J., Yu, T., Cho, S., Park, T., Walsh, J., Ji, Y., Kim, J. J., Lee, H., et al. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c04719 · Cited by 9
Sun, C., Sun, X., Xing, Z., Ji, W., Xia, Y., Lin, Z., Wang, H., Chen, L., Si, S., Ge, L., et al. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202508444 · Cited by 12
Patient-centric care: Unveiling the potential of wearable electronics in clinical practice
Zhao, P., Xu, J., & Han, M. (2024) · Wearable electronics. · doi:10.1016/j.wees.2024.07.001 · Cited by 9
Krüger, G. M., Birkeli, S. G., Hansen, Ø. M., Faldaas, B. O., Norvik, A., Lund, H. J., Hautois, G. L. E., Flage, J. H., Urteaga, J., Hergum, T., et al. (2025) · Resuscitation Plus · doi:10.1016/j.resplu.2025.101080 · Cited by 8
Huang, H., & Chen, Y. (2022) · Journal of Inorganic Materials · doi:10.15541/jim20220194 · Cited by 8
Self-citationYang, X., Zhang, M., Niu, P., Guo, W., Sun, C., Pang, W., Cui, G., & Liu, Q. (2024) · SmartMat · doi:10.1002/smm2.1271 · Cited by 7
Tian, Y., Chen, J., Yan, Z. G., Xie, J., Jiang, X., Li, G., & Huang, G. (2024) · Ultrasonics · doi:10.1016/j.ultras.2024.107344 · Cited by 10
Pu, C., Fu, B., Lu, P., Guan, X., Zhang, J., Shen, Y., Li, X., Guo, L., Xu, H., Jiang, X., et al. (2025) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2025.102684 · Cited by 14
Timmermans, M., van Oosterhout, K., Fattori, M., Neer, P. L. M. J. V., Harpe, P. J. A., & Cantatore, E. (2025) · npj Flexible Electronics · doi:10.1038/s41528-025-00478-5 · Cited by 11
Wearable flexible ultrasonic transducers: materials, applications, and challenges
Guo, L., Liu, J., Li, Y., Xu, R., Song, G., Wu, J., Qian, Z., Ren, L., Ren, L., & Zhou, Q. (2025) · Ultrasonics · doi:10.1016/j.ultras.2025.107872 · Cited by 11
Wearable technologies in clinical trials for drug development: trends and emerging opportunities
Fayad, Z. A., Hirten, R. P., Nadkarni, G. N., & Kim, Y. (2026) · Nature Reviews Drug Discovery · doi:10.1038/s41573-026-01403-9 · Cited by 11
Three-dimensional mapping of the greater palatine artery location and physiology
Qi, B., Khazeinezhad, R., Hariri, A., Yim, W., Jin, Z., Sasi, L., Chen, C., & Jokerst, J. V. (2023) · Dentomaxillofacial Radiology · doi:10.1259/dmfr.20230066 · Cited by 7
Self-citationTextile-based shape-conformable and breathable ultrasound imaging probe
Noda, T., Takamatsu, S., Yamamoto, M., Tomita, N., Itoh, T., Azuma, T., Sakuma, I., & Tomii, N. (2024) · Communications Materials · doi:10.1038/s43246-024-00591-4 · Cited by 12
Framework for Digital Health Phenotypes in Heart Failure
Khedraki, R., Srivastava, A. V., & Bhavnani, S. P. (2022) · Heart Failure Clinics · doi:10.1016/j.hfc.2021.12.003 · Cited by 11
Organic–Inorganic Hybrid Perovskite Materials for Ultrasonic Transducer in Medical Diagnosis
Li, Q., Yang, L., Zhang, S., Wang, F., Gu, Y., Deng, X., & Yang, Y. (2022) · Crystals · doi:10.3390/cryst12081043 · Cited by 8
Self-citationSilicon-Based Stretchable Structure via Parylene Kirigami Interconnection
Han, X., Zhang, M., Chen, L., Zhang, P., Jin, Y., & Wang, W. (2022) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2022.3223059 · Cited by 7
Gopalakrishnan, P. H., & Panicker, M. R. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115588 · Cited by 7
Artificial Intelligence-Driven Wearable Sensors for Cardiovascular Health Monitoring
Deng, H. T., Ma, B., Chen, G., Chi, J., Tong, J., Yu, F., Lü, B., Chen, Y., Zhao, C., Zhang, C., et al. (2026) · ACS Sensors · doi:10.1021/acssensors.5c04840 · Cited by 8
Self-citationZhang, Z., Yang, L., Wang, X., Luo, H., & Wang, Y. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3375407 · Cited by 7
“When the piezo-electric material directly contacts a tissue load, the majority of sound wave energy can be reflected, leading to reduced sensitivity and narrowed bandwidth (BW) of the UT [22], [23].”
BackgroundSelf-citationFlexible ultrasound arrays with embossed polymer structures for medical imaging
Chen, Z., Hua, Q., & Shen, G. (2024) · Journal of Semiconductors · doi:10.1088/1674-4926/24050042 · Cited by 5
Li, H., Xia, Z., Lü, L., Lin, D., Li, X., Chen, Z., Wang, X., & Jiao, J. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116235 · Cited by 5
Flexible ultrasonic transducer array with automatic phase calibration for arteriosclerosis detection
Sun, H., Lv, C., Wang, L., Xie, M., Zeng, Z., & Liu, Y. (2025) · Ultrasonics · doi:10.1016/j.ultras.2025.107850 · Cited by 5
Yu, X., Liang, Z., Yu, C., Tang, Y., Chen, L., Xu, T., Li, S., Zhang, T., & Huo, F. (2025) · Journal of Materials Chemistry C · doi:10.1039/d5tc03140k · Cited by 7
Encapsulated Organohydrogel Couplants for Wearable Ultrasounds
Dong, X., Yang, Z., Xu, C., Jun, Z., Zhu, J., Yi, H., Xu, H., & Li, Z. (2025) · Advanced Electronic Materials · doi:10.1002/aelm.202400961 · Cited by 5
Injectable and retrievable soft electronics
Li, J., Xu, Y., & Gao, W. F. (2024) · Nature Materials · doi:10.1038/s41563-024-01877-1 · Cited by 6
Variable Curvature Flexible Transducer for Abdominal Expandable Imaging
Chen, J., Zhuang, B., Peng, J., Zhang, Z., Wang, B., Dai, C., & Wu, D. (2025) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2025.3527543 · Cited by 5
“U LTRASOUND imaging can provide physicians with intrinsic, nondestructive, and high-resolution visualization of pathological behaviors to guide treatment and prognostic plans due to its noninvasive, real-time, and safety advantages [1], [2], [3].”
Self-citationMechanical biomarkers in respiratory diseases: From mechanobiology to mechanomedicine
Che, B., Ni, K., Liu, Z., Liu, L., Luo, M., & Deng, L. (2025) · Biophysics Reviews · doi:10.1063/5.0266508 · Cited by 3
Integration of porous graphene and 3D-printed piezopolymer for flexible ultrasound transducers
Movaghgharnezhad, S., Ansari, E., Baker, C. A., Bashatah, A., Valenzuela, D. A., Kang, P., & Chitnis, P. V. (2025) · Materials & Design · doi:10.1016/j.matdes.2025.115205 · Cited by 5
“Recent studies have demonstrated tremendous potential of wearable USTs in biomedical applications that require chronic imaging and sensing [5], [6], [7], [8], [9], [10], [11], however, these prior works still used piezoceramics that suffer from challenges associated with rigid and brittle materials.”
Yang, L., Huang, Z., Yang, K., Tang, X., Xie, H., Jiang, Y., Chen, T., Liu, J., Pan, T., Gao, M., et al. (2025) · Advanced Materials · doi:10.1002/adma.202515730 · Cited by 8
Zhang, Z., Yang, L., Lin, D., Wang, X., Wang, Y., & Luo, H. (2023) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2023.3343340 · Cited by 4
Self-citationLu, J., Yan, Y., Xu, J., & Gao, Y. (2024) · Sensors · doi:10.3390/s24175635 · Cited by 3
“As such, the use of ultrasonic devices can provide timely signal detection [12–15] and even non-invasive disease treatment of the human brain [16–20].”
MethodRecent progress in blood flow sensing
Chen, R. Y., Liang, J., Li, M., & Meng, E. F. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116457 · Cited by 3
Inflatable acoustic metasurfaces for tunable wave focusing
Ahn, J., Panahandeh-Shahraki, D., Kim, G., & Daraio, C. (2025) · The Journal of the Acoustical Society of America · doi:10.1121/10.0036567 · Cited by 2
Arbitrarily Shapeable Couplant with Fluidity Onset for Conformal Ultrasound
Chen, J., Hua, Y., Jin, B., Zhan, Z., Zhang, M., Zhang, Y., Jin, R., Liang, X., Cao, R., Hu, X., et al. (2025) · Advanced Materials · doi:10.1002/adma.202505620 · Cited by 5
Wang, B., Peng, J., Li, Y., Yu, H., Huang, Z., Liu, X., & Wu, D. (2025) · Measurement · doi:10.1016/j.measurement.2025.119815 · Cited by 3
Hydrogel metapad with ultrasound transparency and broadband focusing for biomedical imaging
Zhang, J. Y., Yu, D., Zhang, T., Gao, C., Dong, E., Song, Z., Fan, C., Han, Z., Lemoult, F., Fink, M., et al. (2026) · National Science Review · doi:10.1093/nsr/nwag048 · Cited by 5
Huang, Q., Shuaigang, S., Wang, M., Wu, Y., He, Q., Wei, H., Sai, H., & Huang, T. (2026) · Ceramics International · doi:10.1016/j.ceramint.2026.04.388 · Cited by 5
PZT-based flexible ultrasonic sensor arrays for nondestructive testing applications
Wang, H., Wu, Y., Guo, K., Liu, W., Sun, C., Si, S., Chen, L., Li, P., Li, J., & Yang, J. (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.117995 · Cited by 3
Yan, M., Wang, Z., Li, Z. K., Wang, P., Wu, P., Chen, X., Chen, X., Du, L., Wang, Y., Song, J., et al. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01158-8 · Cited by 7
“5h, i) from high-performance 1 – 3 composites 17,46,75 .”
Jia, Y., & Zhang, K. (2023) · Journal of Materials Chemistry C · doi:10.1039/d3tc03612j · Cited by 4
Fast capturing of deep blood flow
Gao, R., Xu, Z., & Liu, C. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01162-7 · Cited by 3
Mizuyama, T., & Nishikawa, H. (2022) · IEEJ Transactions on Electronics Information and Systems · doi:10.1541/ieejeiss.142.1060 · Cited by 3
Ruan, T., Wang, L., Wang, Q., Xu, Q., Cao, J., Jiang, C., Xu, M., Zhu, X., Liu, Q., Yang, B., et al. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202418633 · Cited by 3
Seeing inside a body in motion
Tan, P., & Lu, N. (2022) · Science · doi:10.1126/science.adc8732 · Cited by 3
Zhu, P., Zhao, X., Chen, X., Liu, R., Ouyang, H., Hu, Y., Shi, B., & Fan, Y. (2025) · ACS Sensors · doi:10.1021/acssensors.4c03537 · Cited by 2
Li, Y., Yang, Z., Liu, L., Wu, S., Jiao, Y., & Cui, Y. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3592907 · Cited by 2
“Considering the limitations inherent to F-WUS, several researchers posit that decreasing the ultrasonic transmission center frequency and implementing multi-pulse excitation may increase the tolerance of beamforming to the shape change of F-WUS [24].”
Steerable High‐Resolution Ultrasound Focusing via Phase‐Array‐Activated Acoustic Meta‐Lenses
Cui, X., Liu, X., Wu, P., Yang, J., Zhang, Z., Peng, Y., Bao, S., & Zhu, X. (2025) · Advanced Physics Research · doi:10.1002/apxr.202500147 · Cited by 2
Self-citationFlexible AlScN based PMUT arrays for conformal and wearable ultrasound
Georgitzikis, E., Gijsenbergh, P., Massimino, G., Ukropec, R., Pandit, M., Segers, J., Wysocka, D., Lancker, D. V., Shen, Z., Keulemans, G., et al. (2025) · IEEE International Ultrasonics Symposium · doi:10.1109/ius62464.2025.11201418 · Cited by 2
UltraFlex: Iterative Model-Based Ultrasonic Flexible-Array Shape Calibration
Frey, B. N., Hyun, D., Simson, W. A., Zhuang, L. L., Hashemi, H. S., Schneider, M. K., & Dahl, J. (2025) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2025.3627525 · Cited by 2
“…these conventional transducers have provided immeasurable benefit to ultrasound imaging, the recent development of flexible-array ultrasound transducers opens the door to new applications for ultrasound, including continuous monitoring and wearable ultrasound technologies [1], [2], [3], [4], [5].”
A two-step reconstruction framework for rapid enhancement of ultrasound image quality
Li, X., Zhang, X., Wang, Z., & Shen, Y. (2026) · Measurement · doi:10.1016/j.measurement.2026.120591 · Cited by 3
Metadata
- Authors
- Wang, C., Qi, B., Lin, M., Zhang, Z., Makihata, M., Liu, B., Zhou, S., Huang, Y.-H., Hu, H., Gu, Y., Chen, Y., Lei, Y., Lee, T., Chien, S., Jang, K.-I., Kistler, E. B., & Xu, S.
- Affiliations
- Harvard University (US)
- University of California San Diego (US)
- Yonsei University (KR)
- Daegu Gyeongbuk Institute of Science and Technology (KR)
- Corresponding author
- Xu, Sheng
- ORCID
- Venue
- Nature Biomedical Engineering
- Published
- 2021-07-16
- Volume
- 5
- Issue
- 7
- Pages
- 749-758
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W3177774876
- Semantic Scholar
- c362c08ae1bf66f78c06e49aa3c46c3ecc0a23fa
- Cited by
- 274
- References
- 76
- Citations by year
- 2026: 42 · 2025: 78 · 2024: 62 · 2023: 51 · 2022: 34 · 2021: 7
- FWCI
- 11.70
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Nature Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r21eb027303-02)
- National Institute of Biomedical Imaging and Bioengineering (R21 EB027303)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- wearable diagnostics, Doppler ultrasound, cerebral blood flow
- MeSH terms
- Wearable Electronic Devices, Cerebrovascular Circulation, Heart, Hemodynamics, Humans, Monitoring, Physiologic, Ultrasonography, Doppler, Microarray Analysis, Signal-To-Noise Ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.