Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays
The DOI matches its Crossref record; 75 of the 76 references it cites were found in a registry or an index.
Abstract
Stretchable wearable devices for the continuous monitoring of physiological signals from deep tissues are constrained by the depth of signal penetration and by difficulties in resolving signals from specific tissues. Here, we report the development and testing of a prototype skin-conformal ultrasonic phased array for the monitoring of haemodynamic signals from tissues up to 14 cm beneath the skin. The device allows for active focusing and steering of ultrasound beams over a range of incident angles so as to target regions of interest. In healthy volunteers, we show that the phased array can be used to monitor Doppler spectra from cardiac tissues, record central blood flow waveforms and estimate cerebral blood supply in real time. Stretchable and conformal skin-worn ultrasonic phased arrays may open up opportunities for wearable diagnostics.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Other mechanisms of flexible health monitoring in rehabilitation, like optoelectronic[263,264] and ultrasound[265,266] devices, can also be applied to heartbeat, pulse oximetry, blood pressure, and other on-body measurements.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [265]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Materials and Mechanics for Stretchable Electronics
Rogers, J. A., Someya, T., & Huang, Y. (2010) · Science · doi:10.1126/science.1182383 · Cited by 5,042
Self-citationWearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Ommen, S. R., Nishimura, R. A., Appleton, C. P., Miller, F. A., Oh, J. K., Redfield, M. M., & Tajik, A. J. (2000) · Circulation · doi:10.1161/01.cir.102.15.1788 · Cited by 2,790
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884
Prognosis in Acute Organ-System Failure
KNAUS, W. A., DRAPER, E. A., WAGNER, D. P., & ZIMMERMAN, J. E. (1985) · Annals of Surgery · doi:10.1097/00000658-198512000-00004 · Cited by 1,225
The Assessment of Endothelial Function: From Research Into Clinical Practice
Flammer, A. J., Anderson, T., Celermajer, D. S., Creager, M. A., Deanfield, J., Ganz, P., Hamburg, N. M., Lüscher, T. F., Shechter, M., Taddei, S., et al. (2012) · Circulation · doi:10.1161/circulationaha.112.093245 · Cited by 1,153
Speckle in ultrasound B-mode scans
Burckhardt, C. B. (1978) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1978.30978 · Cited by 1,066
Cope, M., & Delpy, D. T. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447083 · Cited by 1,065
Research works printed but not linked: 1
- J. Lee, H.-S. & Sodini, C. G. in Intracranial Pressure & Neuromonitoring XVI 111–114 (Springer, 2018).
Cited by
Items 201–274 of 274
Xin, C., Wang, Y., Jiang, Y., Hao, B., Xia, N., Zhu, J., Su, L., Zhao, J., Wang, X., Yang, H., et al. (2026) · National Science Review · doi:10.1093/nsr/nwag179 · Cited by 2
“Ultrasound imaging has gained increasing attention owing to its ease of use, absence of radiation, and capacity to visualize tissues at depths exceeding 10 cm with high spatial resolution [36 –38 ].”
Wearable ultrasound: Recent advances and applications in biomedical engineering
Zhang, X., Li, K., Fan, X., Wang, S., Liu, T., Chen, Y., He, X., Chen, H., Xie, J., Liu, L., et al. (2026) · EngMedicine · doi:10.1016/j.engmed.2026.100134 · Cited by 4
Self-citationSynchronous wearable ultrasound for early detection of coronary and carotid artery comorbidity
Lin, S., Xu, H., Li, Y., Ge, X., Chen, K., Chen, L., Tong, M., Wang, F., Wu, D., Lin, H., et al. (2026) · Science Advances · doi:10.1126/sciadv.aed2114 · Cited by 2
Han, X., Chen, L., Zhang, M., Jin, Y., & Wang, W. (2024) · Applied Physics Letters · doi:10.1063/5.0165913 · Cited by 2
Biomechanical mechanism of noninvasive plaque detection based on multi-sensor fusion
Zhu, P., Hu, Y., Shi, B., & Fan, Y. (2024) · Physics of Fluids · doi:10.1063/5.0189604 · Cited by 2
Sonogenetics is a novel antiarrhythmic mechanism
Li, Y. C., Wang, X., Guo, J., Wang, Y., Zykov, V. S., Bodenschatz, E., & Gao, X. (2025) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/5.0224817 · Cited by 3
Han, M., 唐, R.-Y. 若. T., 马, N. 宁. M., Zhang, G., & Zhang, X. (2025) · Chinese Physics B · doi:10.1088/1674-1056/adb38c · Cited by 2
Xia, F., Peng, Y., Ji, W., Saini, G., Wang, Y.-C., Wudaru, A., Yu, X., Luo, M., Guzman, A. D., Wang, Z., et al. (2025) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems61431.2025.10917752 · Cited by 2
“Applications of wearable ultrasound include bladder monitoring [2], hemodynamics assessment [3], and blood vessel monitoring [4].”
An Exploration into the Structuring of Soft Piezoelectric Transducers for Wearable Applications
Peters, L. C. J. M., Verbeek, R., de Haas, G., Gelinck, G. H., Schrama, T., Volker, A. W. F., Merks, E. J. W., & Neer, P. L. M. J. V. (2024) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea60663.2024.10596854 · Cited by 1
“…systems have been published so far, which typically either consist of an array of micro-assembled rigid piezoelectric transducer on to a flexible substrate [1-3] or consist of a relatively small rigid transducer array which is coupled directly to the skin using a bio-adhesive coupling gel [4].”
MethodDesign of Wearable Flexible Cross-Shaped Ultrasonic Transducer Array for Blood Pressure Estimation
Su, M., Dong, L., Wang, S., Cui, Y., Zhang, M., Gao, Y., Liu, C., Yang, W., Cheng, J., Yan, H., et al. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3585406 · Cited by 1
“For example, Wang et al. [15] developed a 12 × 12 flexible piezoelectric transducer array to monitor hemodynamic signals in multiple tissues, and Hu et al. [19] proposed a transducer array for cardiac imaging; however, the electrode structures of these transducer arrays are too complex, requiring…”
Zhang, Z., Yang, L., Xu, J., Liu, Z., Luo, H., & Liu, L. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3611864 · Cited by 1
“T HE phased array ultrasonic transducers (PAUTs) have become increasingly prominent in the field of cardiology clinical diagnostics, attributed to their proficiency in real-time blood flow measurement, high frame rates, and dynamic focusing capabilities [1], [2], [3], [4].”
Self-citationMa, Y., Hu, X., Gong, Y., Xu, X., Pang, W., Niu, P., & Wang, Z. (2025) · IEEE International Ultrasonics Symposium · doi:10.1109/ius62464.2025.11201403 · Cited by 1
“But for major arteries such as the carotid artery, continuous B-mode imaging that can scan the whole target area and penetrate deeper seems a more intuitive and accurate method [11].”
Soft wearable piezoelectric sensors based on PZT/SMPU composites for monitoring small arteries
Li, Y., Li, B., Xu, H., Huang, X., Zhou, C., Ren, M., Huang, R., Cui, T., Lin, J., & Chen, H. (2025) · Measurement · doi:10.1016/j.measurement.2025.120255 · Cited by 1
Shang, C., Qi, H., Wang, Z., Meng, K., Liu, Z., Meng, Z., Yang, Y., Wang, J., & Jiang, S. (2026) · Advanced Science · doi:10.1002/advs.202516891 · Cited by 1
“For example, as illustrated in Figure 4a [ 63 ], in biomedical monitoring, optical measurements are typically limited to imaging peripheral blood vessels at depths of less than 6 cm.”
Wang, H., Guo, K., Wu, Y., Yang, A., Sun, C., Si, S., Chen, L., Li, P., Li, J., & Yang, J. (2026) · Nondestructive Testing And Evaluation · doi:10.1080/10589759.2026.2615143 · Cited by 1
Spatiotemporal acoustic meta-patches for multifactorial wound treatment
Wu, Z., Gan, J., & Zhao, Y. (2026) · Bioactive Materials · doi:10.1016/j.bioactmat.2026.01.023 · Cited by 1
“These patches are widely recognized for their non-invasive diagnostic capabilities [5 – 7].”
Lin, S., Chen, K., Yang, J., Wen, J., & Kong, D. (2026) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2026.114027 · Cited by 1
Ou, S., Li, X., Tang, X., Hu, Y., Shiming, X. U., Cai, M., Zhao, J., Chen, J., Chen, Q., Zeng, J., et al. (2026) · Ceramics International · doi:10.1016/j.ceramint.2026.03.161 · Cited by 1
Self-citationCui, A., Du, Y., & Sun, L. (2026) · International Journal of Nanomedicine · doi:10.2147/ijn.s618076 · Cited by 1
“61 That development could support future molecular-ultrasound workflows, but it does not remove the need for standardized biomaterials, exposure estimation, and clinician governance.”
Wang, Y., & Wu, T. (2026) · AI Sensors · doi:10.3390/aisens2030011 · Cited by 1
“Stretchable ultrasonic phased arrays have been demonstrated for continuous monitoring of deep-tissue hemodynamics, enabling real-time measurement of blood flow velocity and arterial diameter in moving subjects [160].”
Advanced methods of wearable ultrasound and photoacoustic imaging devices: A review
Luo, M., Zhang, S., Jiang, W., Miao, J., Zhao, Z., & Li, L. S. (2026) · Photoacoustics · doi:10.1016/j.pacs.2026.100884 · Cited by 1
“Representative Level 1 systems include bioadhesive or conformal ultrasound and PA patches that retain off-board instrumentation [39,48,49].”
InfluentialResearch progress in flexible wearable sensing and intelligent recognition techniques
Wan, C., Wu, Z., & Huang, X. L. (2022) · Scientia Sinica Chimica · doi:10.1360/ssc-2022-0164 · Cited by 2
Sobotnicka, E., Mocha, J., Sobotnicki, A., Gałecka, J., & Gacek, A. (2023) · Lecture notes in networks and systems · doi:10.1007/978-3-031-38430-1_30 · Cited by 1
Zhang, J., Xie, H., Hu, Y., Sun, W., Lv, M., Han, T., Tian, X., Wang, S., & Su, M. (2024) · Advanced Sensor Research · doi:10.1002/adsr.202300158 · Cited by 1
Fattori, M., Genco, E., Garripoli, C., Zulqarnain, M., Myny, K., & Cantatore, E. (2024) · Custom Integrated Circuits Conference · doi:10.1109/cicc60959.2024.10529016 · Cited by 2
“…include distributed large-area sensing for monitoring of audio [3][4], force [5][6], proximity [7][8], biochemical [9][10], ultrasound signals [11], radio frequency identification tags (RFIDs) [12]-[16], flexible batteries [17][18] and energy harvesters [19][20], wearable devices [21][22],…”
BackgroundLiu, W., Wu, D., & Zhu, C. (2021) · IEEE International Ultrasonics Symposium · doi:10.1109/ius52206.2021.9593471 · Cited by 1
“Stretchable ultrasonic arrays can be extended along with the biaxial directions and have the capability of conforming to various complex surfaces, which has great potential applications in nondestructive testing, neuromodulation, ultrasound therapy, and health monitoring [1-5].”
BackgroundUltrasound-actuated drug delivery with acoustic percolation switchesPreprint
Abundo, M. P., Tifrea, A. T., Buss, M. T., Barturen‐Larrea, P., Jin, Z., Malounda, D., & Shapiro, M. G. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.05.10.593654 · Cited by 1
Minimally-invasive and non-invasive flexible devices for robust characterizations of deep tissues
Yuan, Y., Tang, W., Wu, H., Chen, S., Ren, X., Hu, B., & Gu, N. (2022) · Scientia Sinica Chimica · doi:10.1360/ssc-2022-0100
Mizuyama, T., & Nishikawa, H. (2023) · Electronics and Communications in Japan · doi:10.1002/ecj.12386
Fernández, M. Á. G. (2023) · Revista de ecocardiografía práctica y otras técnicas de imagen cardíaca · doi:10.37615/retic.v6n1a1
Conclusion and research directions
Bolić, M. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-820947-9.00013-1
Development of flexible transducers for ultrasonic plane wave imaging
Bian, C., Sun, H., Wang, L., Liu, C., & Liu, Y. (2023) · IEEE International Ultrasonics Symposium · doi:10.1109/ius51837.2023.10307425
Rey, A. B. A., Seabra, A. C. G., & Stieglitz, T. (2024) · doi:10.36227/techrxiv.171259948.82540155/v1
UltraGelBot: Autonomous Gel Dispenser for Robotic Ultrasound
Raina, D., Delhi, A., Zhao, Z., Voyles, R. M., Wachs, J. P., Saha, S. K., & Chandrashekhara, S. H. (2024) · Hamlyn Symposium on Medical Robotics (HSMR) · doi:10.31256/hsmr2024.60
“This human intervention between the procedure results in the acquisition of sub-optimal images due to inappropriate acoustic coupling [7].”
BackgroundAmplitude and Phase Errors Optimization for High-Precision Electrical Impedance Measurement System
Luan, L., Mao, Y., Zhang, W., Ni, J., Xu, L., & Liu, B. (2024) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas61083.2024.10798264
“For instance, electrical impedance tomography is the only non-radiative continuous lung imaging method, which has been shown to improve the survival rates of patients with lung diseases [8-9].”
Self-citationBeker, L., Toymuş, A. T., Peker, S., Atik, A. Y., Yener, U. C., Albay, M. M., Yılgör, E., & Yılgör, İ. (2025) · Research Square · doi:10.21203/rs.3.rs-5633578/v1
Li, T., Wan, Z., Wang, Q., Qiao, F., Pan, G., Zhao, C., Zhu, Y., Zhou, H., Tan, Y., Zhou, Z., et al. (2025) · Small · doi:10.1002/smll.202406144 · Cited by 1
Digital health technologies in clinical trials—Regulatory basics
Bhavnani, S. P. (2025) · Elsevier eBooks · doi:10.1016/b978-0-323-91790-2.00105-2
Conformal Ultrasound Patch for Real-Time Blood Flow Monitoring
Lee, T., Park, J., Kim, I.-S., Bang, S., Jung, J., & Lee, H. J. (2025) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems61431.2025.10917810
“A stretchable ultrasonic array which integrates piezoelectric elements with stretchable electrodes on a soft substrate enables continuous deep tissue monitoring by adhering conformally to dynamic non-developable human skin [13].”
Self-citationWearable Sensor for Bioimaging
Liang, C., Zhou, J., Zhao, N., Lai, P., & Zhou, Y. (2025) · doi:10.1002/9783527845507.ch9
A Flexible, Stretchable and Highly Durable Ultrasound Patch for Dynamic Monitoring of Muscle Tissue
Huang, Z., Gu, Y., Yao, C., Wang, W., & Liu, T. (2025) · IEEE/ASME International Conference on Advanced Intelligent Mechatronics · doi:10.1109/aim64088.2025.11175782
“Hu et al. [22] utilized a stretchable ultrasound phased-array device to perform elastography of muscle tissue, detecting microstructural damage during muscle strain and monitoring dynamic recovery processes.”
Self-citationHuiqing, 赵. Z., Dezheng, 李. L., Jichuan, 仇. Q., & Hong, 刘. L. (2025) · Chinese Journal of Lasers · doi:10.3788/cjl250952
Sundar, A., & Ganesan, A. (2025) · Communications in computer and information science · doi:10.1007/978-3-032-05144-8_14
A Flexible Ultrasound Transducer Array for Deep Vein Thrombosis Monitoring
Lu, P., Li, Y., Jiang, C., & Peng, C. (2025) · IEEE International Ultrasonics Symposium · doi:10.1109/ius62464.2025.11201773
“Wang et al. [9] proposed a skin-conformal phased-array ultrasound transducer capable of monitoring hemodynamic signals up to 14 cm beneath the skin surface.”
An adaptive wearable ultrasonic transducer based on 3D printing
Wang, B., Xiao, W., Peng, J., Li, Y., Chen, J., & Wu, D. (2025) · IEEE International Ultrasonics Symposium · doi:10.1109/ius62464.2025.11201356
“Researchers integrated multiple rigid components into a stretchable sensor array using silicone elastomer-encapsulated island-bridge electrodes, enabling continuous assessment of waveform patterns related to central blood pressure and deep tissue hemodynamic [5], [6], [7].”
Introduction to Nano-Bioelectronics for Precision Health Monitoring
Tripathi, A., & Bonilla‐Cruz, J. (2025) · Springer eBooks · doi:10.1007/978-981-95-2117-3_2
Biomechanical Monitoring of Rotator Cuff by an Ultrasensitive Stretchable and Implantable Sensor
Liu, Q., Yan, H., Li, J., Fu, H., Guo, X., Yang, X., Cui, G., & Zhang, M. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202500642
Artificial intelligence in neonatal hemodynamics: Cerebral autoregulation
Arichai, P., Wu, T.-W., Seri, I., & Noori, S. (2025) · Seminars in Fetal and Neonatal Medicine · doi:10.1016/j.siny.2025.101686 · Cited by 1
Fabrication of Stretchable Piezoelectric Sensor with a Kirigami Design for Heart Sound Monitoring
Zhang, X., Ye, X., Lei, X., Hu, H., Liu, H., Jin, S., Ye, G., & Zhao, T. (2025) · Sensors · doi:10.3390/s25237253
“Furthermore, the rigid structure has poor adherence to the skin and cannot adapt to skin deformation during human movement, failing to meet the requirements of wearable long-term continuous monitoring [7–9].”
Self-citationPerez, S. A., Lin, M., Zhou, S., Walba, L., Frederick, D., Kistler, E. B., Barleben, A. R., Malas, M. B., Xu, S. H., & Ross, E. (2025) · Annals of Vascular Surgery · doi:10.1016/j.avsg.2025.11.139
Self-citationToymuş, A. T., Peker, S., Atik, A. Y., Yener, U. C., Albay, M. M., Yılgör, E., YILGÖR, I., & Beker, L. (2026) · Device · doi:10.1016/j.device.2026.101076
Flexible Ultrasound Sensor Based on ErPMNPT Ceramics for Vascular Monitoring
Li, Z., Wang, X., Liu, D., Wang, Y. T., Lindsey, B., Bartlett, M. A., Abrahams, I., Busfield, J. J. C., Yan, H., Zhang, H., et al. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3676618
“D EVICE A SSEMBLY Soft electronic circuits can currently be fabricated using various techniques such as laser etching [23], [30], stencil lithography [3], inkjet printing [31], [32], 3-”
Stretchable nanocomposites with tunable acoustic impedance for ultrasound devices
Chu, Y., Brown, S. A., Sha, Z., Phan, H., Wang, C. H., & Peng, S. (2026) · Materials & Design · doi:10.1016/j.matdes.2026.116113
Self-citationChao, X., Lin, J., Wang, Y., Hu, B., Hu, H., Xie, L., Ge, J., Yu, S., Wang, P., Liang, M., et al. (2026) · Thin-Walled Structures · doi:10.1016/j.tws.2026.115130 · Cited by 2
Self-citationPre-snapback mode operation of CMUT for enhanced acoustic performance
Park, S., Oh, C., Lee, W., Huh, K. Y., Lee, B. C., & Lee, H. J. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01228-x
“Clinical applications range from traditional diagnostics 1,2,7,8 to emerging therapeutic 4,9 – 12 and neuromodulation techniques 13 – 17 , including high-intensity focused ultrasound for tumor ablation 18 and blood – brain barrier opening for drug delivery 19 – 21 .”
Zhang, Z., Wang, Q., Chen, Z., Huang, X., Zhong, X., Xu, J., 罗豪甦, & Wu, L. (2026) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ae7981
Self-citationIntegrated thermal sensing of vascular morphology for haemodynamic monitoring
Tian, Y., Deng, Y., Tan, J., Peng, L., & Lin, Z.-Y. (2026) · Nature Sensors · doi:10.1038/s44460-026-00082-8
“Although existing wearable ultrasound imaging devices can obtain vascular morphology 25–27 , their high data-processing costs and integration complexity limit their use for low-cost, long-term home monitoring 27,28 (https://verasonics.com/).”
Flexible ultrasound patches for cardiovascular function and disease monitoring
Zhou, Y., Xu, X., Zhang, Z., Wu, H., Yin, X., Chen, X., Wang, C., Kang, Y., Zhou, X., & Ge, M. (2026) · The Innovation Materials · doi:10.59717/j.xinn-mater.2026.100231
Self-citationBioinspired Permeable Soft Electronics for Advanced Healthcare Monitoring
Yuan, M., Zeng, Z., Zhao, J., Ji, J., Liu, J., Sun, Y., Lin, T., Dong, S., & Fang, Y. (2026) · Advanced Fiber Materials · doi:10.1007/s42765-026-00747-6 · Cited by 1
Wearable ultrasound: Design, development, and application in precision medicine
Dong, H., Liang, X., Liu, X., 邢长洋, & Yuan, L. (2026) · EngMedicine · doi:10.1016/j.engmed.2026.100149
Gao, J., Wang, Y., Huang, F., Guan, Z., Jiang, Y., Cheng, W., Shi, Y., & Pan, L. (2026) · Materials Today · doi:10.1016/j.mattod.2026.103493
A soft 64-channel wearable ultrasound patch system for dynamic deep-tissue imagingPreprint
Zhang, H., Hou, Y., Wang, J., Zhang, D., Lu, Y., Chen, C., Chen, D., Lu, H., Feng, L., Chen, H., et al. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.7385568
Qiguo, H., Wang, M., Wu, Y., Shuaigang, S., He, Q., Sai, H., & Tuo, Z. (2026) · Smart Materials and Structures · doi:10.1088/1361-665x/aea3cc
Li, M., Deng, X., Yao, P., Jia, L., Lv, X., Song, Y., Wu, Y., Li, Z., & Liu, Z. (2026) · Nano Energy · doi:10.1016/j.nanoen.2026.112383
Ultrathin wearable ultrasound patch with anti-matching for carotid artery monitoring
Yang, Y., Zhang, X., Li, Y., Li, H., Tan, Y., Li, C., Xu, L., & Ma, J. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.119224
Qi, L., & Yang, T. (2026) · Micromachines · doi:10.3390/mi17091093
“Conventional blood flow measurement techniques, such as Doppler ultrasound and photoacoustic imaging, can provide detailed vascular information but commonly rely on specialized or relatively bulky instrumentation, coupling media, and controlled probe positioning [15].”
Flexible biointegrated multimodal sensing systems for human health, plants and environments
Wang, A., Liu, K., Wang, H., & Ye, C. (2026) · Wearable electronics. · doi:10.1016/j.wees.2026.08.001
He, M., Zhuang, X., & Cao, R. (2026) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-026-01162-1
“Building on improved coupling, a skin-conformal phased array focuses and steers actively, monitoring hemodynamic signals up to 14 cm below the skin [104 ].”
Shao, N., Gan, J., Jiang, W., Wu, Z., Cao, L., & Zhao, Y. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.182984
From stretchable materials and functional fibers to intelligent textile sensing systems
Papaefstathiou, M., Elgendi, M., & Menon, C. (2026) · Communications Materials · doi:10.1038/s43246-026-01333-4
“…rigid conductors in stretchable electronics, they have constraints such as limited stretchability compared to material-based approaches 138 , typically stretchability of serpentine ~ 30 – 100% 139 – 141 , longitudinal wave ~50 – 200% and higher kirigami, (pattern-dependent) ~500 – 1000% 142,143 .”
Ren, D., Gao, D., Wang, Y., Wang, S., Meng, Y., Chen, R., Li, C., Shi, J., & Yin, Y. (2026) · ACS Sensors · doi:10.1021/acssensors.6c03176
A Wearable Ultrasound Sensor for the Simultaneous Assessment of Hemodynamics and Blood Pressure
Li, X., Zhu, S., Wang, H., Zhou, Z., Wu, B., Li, Y., Zheng, C., Fu, Y., Tian, Y., Liu, T., et al. (2026) · ACS Sensors · doi:10.1021/acssensors.6c02065
Zhang, L., Xiao, S., Wu, S., Xia, J., & Zhou, Q. (2026) · Photoacoustics · doi:10.1016/j.pacs.2026.100899
Wearable Ultrasound in Cardiovascular Monitoring: Clinical Evidence and Translational Challenges
Han, X., Ma, X., Yu, F., Cai, L., Ren, P., Shi, P. X.-Q., & Wang, Z. (2026) · Advanced ultrasound in diagnosis and therapy · doi:10.26599/audt.2026.260039
Metadata
- Authors
- Wang, C., Qi, B., Lin, M., Zhang, Z., Makihata, M., Liu, B., Zhou, S., Huang, Y.-H., Hu, H., Gu, Y., Chen, Y., Lei, Y., Lee, T., Chien, S., Jang, K.-I., Kistler, E. B., & Xu, S.
- Affiliations
- Harvard University (US)
- University of California San Diego (US)
- Yonsei University (KR)
- Daegu Gyeongbuk Institute of Science and Technology (KR)
- Corresponding author
- Xu, Sheng
- ORCID
- Venue
- Nature Biomedical Engineering
- Published
- 2021-07-16
- Volume
- 5
- Issue
- 7
- Pages
- 749-758
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W3177774876
- Semantic Scholar
- c362c08ae1bf66f78c06e49aa3c46c3ecc0a23fa
- Cited by
- 274
- References
- 76
- Citations by year
- 2026: 42 · 2025: 78 · 2024: 62 · 2023: 51 · 2022: 34 · 2021: 7
- FWCI
- 11.70
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Nature Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r21eb027303-02)
- National Institute of Biomedical Imaging and Bioengineering (R21 EB027303)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- wearable diagnostics, Doppler ultrasound, cerebral blood flow
- MeSH terms
- Wearable Electronic Devices, Cerebrovascular Circulation, Heart, Hemodynamics, Humans, Monitoring, Physiologic, Ultrasonography, Doppler, Microarray Analysis, Signal-To-Noise Ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.