The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
In-ear integrated sensor array for the continuous monitoring of brain activity and of lactate in sweat
Open accessAbstract
Owing to the proximity of the ear canal to the central nervous system, in-ear electrophysiological systems can be used to unobtrusively monitor brain states. Here, by taking advantage of the ear’s exocrine sweat glands, we describe an in-ear integrated array of electrochemical and electrophysiological sensors placed on a flexible substrate surrounding a user-generic earphone for the simultaneous monitoring of lactate concentration and brain states via electroencephalography, electrooculography and electrodermal activity. In volunteers performing an acute bout of exercise, the device detected elevated lactate levels in sweat concurrently with the modulation of brain activity across all electroencephalography frequency bands. Simultaneous and continuous unobtrusive in-ear monitoring of metabolic biomarkers and brain electrophysiology may allow for the discovery of dynamic and synergetic interactions between brain and body biomarkers in real-world settings for long-term health monitoring or for the detection or monitoring of neurodegenerative diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · cited 1×
“Recent advances in high-performance, stretchable and conformal skin interfaces 1,2 are yielding opportunities for unobtrusive physiological 3,4 and metabolic 5,6 monitoring in a highly wearable setting.”
BackgroundA soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
A laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat
Yang, Y., Song, Y., Bo, X., Min, J., Pak, O. S., Zhu, L., Wang, M., Tu, J., Kogan, A., Zhang, H., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-019-0321-x · Cited by 1,270 · cited 1×
“Recent advances in high-performance, stretchable and conformal skin interfaces 1,2 are yielding opportunities for unobtrusive physiological 3,4 and metabolic 5,6 monitoring in a highly wearable setting.”
BackgroundImani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861
Self-citationWearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778 · cited 1×
“…non-invasive technologies (such as epidermal patches) or optical procedures (via near-infrared or ultraviolet–visible light or Raman spectroscopy) 18 , their availability in the market as reliable commercial technologies is limited in the form of skin-penetrating filaments or blood collection…”
BackgroundSelf-citationAn epidermal patch for the simultaneous monitoring of haemodynamic and metabolic biomarkers
Sempionatto, J. R., Lin, M., Yin, L., De la paz, E., Pei, K., Sonsa-ard, T., de Loyola Silva, A. N., Khorshed, A. A., Zhang, F., Tostado, N., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00685-1 · Cited by 658 · cited 1×
“Several of these sensing modalities can be integrated to offer greater functionality where biosignals of interest are conveniently co-located 7,8 .”
BackgroundSelf-citationDiagnostic challenges in epilepsy: seizure under-reporting and seizure detection
Elger, C. E., & Hoppe, C. (2018) · The Lancet Neurology · doi:10.1016/s1474-4422(18)30038-3 · Cited by 403 · cited 1×
“…that some of the day-to-day cognitive state variations such as stress 9 and emotions 10 , as well as neurodegenerative diseases, such as epilepsy 11 and Alzheimer’s disease 12 , can trigger characteristic patterns in both electrophysiological brain-state monitoring and produce abnormal Article…”
BackgroundIndividual variability in human blood metabolites identifies age-related differences
Chaleckis, R., Murakami, I., Takada, J., Kondoh, H., & Yanagida, M. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1603023113 · Cited by 373 · cited 1×
“…or ultraviolet–visible light or Raman spectroscopy) 18 , their availability in the market as reliable commercial technologies is limited in the form of skin-penetrating filaments or blood collection approaches that require small or higher volumes of sample to perform metabolite analysis 19 .”
BackgroundExercise benefits on Alzheimer’s disease: State-of-the-science
Valenzuela, P. L., Castillo-García, A., Morales, J. S., de la Villa, P., Hampel, H., Emanuele, E., Lista, S., & Lucia, A. (2020) · Ageing Research Reviews · doi:10.1016/j.arr.2020.101108 · Cited by 337 · cited 1×
“Clinical evidence has further corroborated the conducive role of the monitoring and control of metabolite levels (such as those of lactate) in improving brain functions by enhancing neuroplasticity and angiogenesis 15,16 .”
BackgroundEyeglasses based wireless electrolyte and metabolite sensor platform
Sempionatto, J. R., Nakagawa, T., Pavinatto, A., Mensah, S. T., Imani, S., Mercier, P., & Wang, J. (2017) · Lab on a Chip · doi:10.1039/c7lc00192d · Cited by 311 · cited 1×
“The performance of the in-ear electrochemical sensor was first evaluated in vitro under the established concentration range of sweat lactate 39 .”
BackgroundSelf-citation
Cited by
Hybrid multimodal wearable sensors for comprehensive health monitoring
Mahato, K., Saha, T., Ding, S., Sandhu, S. S., Chang, A.-Y., & Wang, J. (2024) · Nature Electronics · doi:10.1038/s41928-024-01247-4 · Cited by 404
Self-citationZhang, Y., Wei, G., Liu, W., Li, T., Wang, Y., Zhou, M., Liu, Y., Wang, X., & Wei, H. (2024) · Nature Reviews Methods Primers · doi:10.1038/s43586-024-00315-5 · Cited by 350
Applied body-fluid analysis by wearable devices
Brasier, N., Wang, J., Gao, W., Sempionatto, J. R., Dincer, C., Ates, H. C., Güder, F., Olenik, S., Schauwecker, I., Schaffarczyk, D., et al. (2024) · Nature · doi:10.1038/s41586-024-08249-4 · Cited by 298
Self-citation
Metadata
- Authors
- Xu, Y., De la Paz, E., Paul, A., Mahato, K., Sempionatto, J. R., Tostado, N., Lee, M., Hota, G., Lin, M., Uppal, A., Chen, W., Dua, S., Yin, L., Wuerstle, B. L., Deiss, S., Mercier, P., Xu, S., Wang, J., & Cauwenberghs, G.
- Venue
- Nature Biomedical Engineering
- Published
- 2023-09-28
- Volume
- 7
- Issue
- 10
- Pages
- 1307-1320
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W4387130473
- Cited by
- 175
- References
- 12
- FWCI
- 12.84
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In-ear integrated sensor array for the continuous monitoring of brain activity and of lactate in sweat. https://app.cochat.ai/papers/10.1038/s41551-023-01095-1
- The paper
- Xu, Y., De la Paz, E., Paul, A., Mahato, K., Sempionatto, J. R., Tostado, N., Lee, M., Hota, G., Lin, M., Uppal, A., Chen, W., Dua, S., Yin, L., Wuerstle, B. L., Deiss, S., Mercier, P., Xu, S., Wang, J., & Cauwenberghs, G. (2023). In-ear integrated sensor array for the continuous monitoring of brain activity and of lactate in sweat. Nature Biomedical Engineering. https://doi.org/10.1038/s41551-023-01095-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.