In-ear integrated sensor array for the continuous monitoring of brain activity and of lactate in sweat
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Owing to the proximity of the ear canal to the central nervous system, in-ear electrophysiological systems can be used to unobtrusively monitor brain states. Here, by taking advantage of the ear’s exocrine sweat glands, we describe an in-ear integrated array of electrochemical and electrophysiological sensors placed on a flexible substrate surrounding a user-generic earphone for the simultaneous monitoring of lactate concentration and brain states via electroencephalography, electrooculography and electrodermal activity. In volunteers performing an acute bout of exercise, the device detected elevated lactate levels in sweat concurrently with the modulation of brain activity across all electroencephalography frequency bands. Simultaneous and continuous unobtrusive in-ear monitoring of metabolic biomarkers and brain electrophysiology may allow for the discovery of dynamic and synergetic interactions between brain and body biomarkers in real-world settings for long-term health monitoring or for the detection or monitoring of neurodegenerative diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · cited 1×
“Recent advances in high-performance, stretchable and conformal skin interfaces 1,2 are yielding opportunities for unobtrusive physiological 3,4 and metabolic 5,6 monitoring in a highly wearable setting.”
BackgroundA soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308 · cited 1×
“Recent advances in high-performance, stretchable and conformal skin interfaces 1,2 are yielding opportunities for unobtrusive physiological 3,4 and metabolic 5,6 monitoring in a highly wearable setting.”
BackgroundA laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat
Yang, Y., Song, Y., Bo, X., Min, J., Pak, O. S., Zhu, L., Wang, M., Tu, J., Kogan, A., Zhang, H., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-019-0321-x · Cited by 1,270 · cited 1×
“Recent advances in high-performance, stretchable and conformal skin interfaces 1,2 are yielding opportunities for unobtrusive physiological 3,4 and metabolic 5,6 monitoring in a highly wearable setting.”
BackgroundDry-Contact and Noncontact Biopotential Electrodes: Methodological Review
Chi, Y. M., Jung, T.-P., & Cauwenberghs, G. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084078 · Cited by 1,061 · cited 1×
“Sweat concentration inside the ear was an influencing factor because it affected the conductivity of the skin, the electrode–ear interface and the PVA hydrogel.”
BackgroundSelf-citationIdentifying Stable Patterns over Time for Emotion Recognition from EEG
Zheng, W.-L., Zhu, J.-Y., & Lu, B.-L. (2019) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2017.2712143 · Cited by 990 · cited 1×
“Previous medical studies have suggested that some of the day-to-day cognitive state variations such as stress 9 and emotions 10 , as well as neurodegenerative diseases, such as epilepsy 11 and Alzheimer’s disease 12 , can trigger characteristic patterns in both electrophysiological brain-state…”
BackgroundImani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861 · cited 2×
“Several of these sensing modalities can be integrated to offer greater functionality where biosignals of interest are conveniently co-located 7,8 .”
BackgroundMethodSelf-citationWearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778 · cited 1×
“…non-invasive technologies (such as epidermal patches) or optical procedures (via near-infrared or ultraviolet–visible light or Raman spectroscopy) 18 , their availability in the market as reliable commercial technologies is limited in the form of skin-penetrating filaments or blood collection…”
BackgroundSelf-citationA wearable biosensing system with in-sensor adaptive machine learning for hand gesture recognition
Moin, A., Zhou, A., Rahimi, A., Menon, A., Benatti, S., Alexandrov, G., Tamakloe, S., Ting, J., Yamamoto, N., Khan, Y., et al. (2020) · Nature Electronics · doi:10.1038/s41928-020-00510-8 · Cited by 680 · cited 1×
“Recent advances in high-performance, stretchable and conformal skin interfaces 1,2 are yielding opportunities for unobtrusive physiological 3,4 and metabolic 5,6 monitoring in a highly wearable setting.”
BackgroundAn epidermal patch for the simultaneous monitoring of haemodynamic and metabolic biomarkers
Sempionatto, J. R., Lin, M., Yin, L., De la paz, E., Pei, K., Sonsa-ard, T., de Loyola Silva, A. N., Khorshed, A. A., Zhang, F., Tostado, N., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00685-1 · Cited by 658 · cited 1×
“Several of these sensing modalities can be integrated to offer greater functionality where biosignals of interest are conveniently co-located 7,8 .”
BackgroundSelf-citationA fully automated correction method of EOG artifacts in EEG recordings
Schlögl, A., Keinrath, C., Zimmermann, D., Scherer, R., Leeb, R., & Pfurtscheller, G. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.09.003 · Cited by 575 · cited 1×
“…sensing modality available in the ear is eye movement characterized by electrooculography (EOG), often considered as artefacts in EEG measurements 34 while finding utility for some BCI applications including drowsiness detection 35 , eye vergence therapy 36 and motor control 37,38 .”
BackgroundDriver Fatigue Detection Systems: A Review
Sikander, G., & Anwar, S. (2019) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2018.2868499 · Cited by 556 · cited 1×
“…sensing modality available in the ear is eye movement characterized by electrooculography (EOG), often considered as artefacts in EEG measurements 34 while finding utility for some BCI applications including drowsiness detection 35 , eye vergence therapy 36 and motor control 37,38 .”
BackgroundWearable Electroencephalography
Casson, A., Yates, D., Smith, S., Duncan, J., & Rodriguez-Villegas, E. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2010.936545 · Cited by 404 · cited 1×
“Recent advances in high-performance, stretchable and conformal skin interfaces 1,2 are yielding opportunities for unobtrusive physiological 3,4 and metabolic 5,6 monitoring in a highly wearable setting.”
BackgroundDiagnostic challenges in epilepsy: seizure under-reporting and seizure detection
Elger, C. E., & Hoppe, C. (2018) · The Lancet Neurology · doi:10.1016/s1474-4422(18)30038-3 · Cited by 403 · cited 1×
“…that some of the day-to-day cognitive state variations such as stress 9 and emotions 10 , as well as neurodegenerative diseases, such as epilepsy 11 and Alzheimer’s disease 12 , can trigger characteristic patterns in both electrophysiological brain-state monitoring and produce abnormal Article…”
BackgroundMulticlass Common Spatial Patterns and Information Theoretic Feature Extraction
Grosse-Wentrup, M., & Buss, M. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.921154 · Cited by 389 · cited 2×
“The FBCSP approach has been widely deployed as a classification algorithm for scalp-EEG motor imagery tasks 45,46 .”
BackgroundMethodIndividual variability in human blood metabolites identifies age-related differences
Chaleckis, R., Murakami, I., Takada, J., Kondoh, H., & Yanagida, M. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1603023113 · Cited by 373 · cited 1×
“…or ultraviolet–visible light or Raman spectroscopy) 18 , their availability in the market as reliable commercial technologies is limited in the form of skin-penetrating filaments or blood collection approaches that require small or higher volumes of sample to perform metabolite analysis 19 .”
BackgroundExercise benefits on Alzheimer’s disease: State-of-the-science
Valenzuela, P. L., Castillo-García, A., Morales, J. S., de la Villa, P., Hampel, H., Emanuele, E., Lista, S., & Lucia, A. (2020) · Ageing Research Reviews · doi:10.1016/j.arr.2020.101108 · Cited by 337 · cited 1×
“Clinical evidence has further corroborated the conducive role of the monitoring and control of metabolite levels (such as those of lactate) in improving brain functions by enhancing neuroplasticity and angiogenesis 15,16 .”
BackgroundEyeglasses based wireless electrolyte and metabolite sensor platform
Sempionatto, J. R., Nakagawa, T., Pavinatto, A., Mensah, S. T., Imani, S., Mercier, P., & Wang, J. (2017) · Lab on a Chip · doi:10.1039/c7lc00192d · Cited by 311 · cited 1×
“The performance of the in-ear electrochemical sensor was first evaluated in vitro under the established concentration range of sweat lactate 39 .”
BackgroundSelf-citationKwon, Y.-T., Kim, Y.-S., Kwon, S., Mahmood, M., Lim, H.-R., Park, S.-W., Kang, S.-O., Choi, J. J., Herbert, R., Jang, Y. C., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-17288-0 · Cited by 233 · cited 1×
“Recent advances in high-performance, stretchable and conformal skin interfaces 1,2 are yielding opportunities for unobtrusive physiological 3,4 and metabolic 5,6 monitoring in a highly wearable setting.”
BackgroundBrain electrocortical activity during and after exercise: A quantitative synthesis
Crabbe, J. B., & Dishman, R. K. (2004) · Psychophysiology · doi:10.1111/j.1469-8986.2004.00176.x · Cited by 216 · cited 2×
“…bands including theta (4–8 Hz), alpha (8–12 Hz) and beta (13–30 Hz) during and right after acute exercise, driven by changes in peripheral physiology and not only within the brain itself, and returning to pre-exercise baseline resting-state EEG levels approximately 10 min after exercise 43,44 .”
BackgroundResultMa, J., Zhang, Y., Cichocki, A., & Matsuno, F. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2369483 · Cited by 209 · cited 1×
“…sensing modality available in the ear is eye movement characterized by electrooculography (EOG), often considered as artefacts in EEG measurements 34 while finding utility for some BCI applications including drowsiness detection 35 , eye vergence therapy 36 and motor control 37,38 .”
BackgroundKappel, S. L., Rank, M. L., Toft, H. O., Andersen, M., & Kidmose, P. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2835778 · Cited by 172 · cited 3×
“In-ear electrophysiological sensing systems 24,25 provide elegant solutions to unobtrusive brain-state monitoring inside the ear canal.”
BackgroundChanges in EEG during graded exercise on a recumbent cycle ergometer.
Bailey, S. P., Hall, E. E., Folger, S. E., & Miller, P. C. (2008) · Europe PMC (PubMed Central) · Cited by 166
Mishra, S., Kim, Y.-S., Intarasirisawat, J., Kwon, Y.-T., Lee, Y., Mahmood, M., Lim, H.-R., Herbert, R., Yu, K. J., Ang, C. S., et al. (2020) · Science Advances · doi:10.1126/sciadv.aay1729 · Cited by 164 · cited 1×
“…sensing modality available in the ear is eye movement characterized by electrooculography (EOG), often considered as artefacts in EEG measurements 34 while finding utility for some BCI applications including drowsiness detection 35 , eye vergence therapy 36 and motor control 37,38 .”
BackgroundHearables: Multimodal physiological in-ear sensing
Goverdovsky, V., von Rosenberg, W., Nakamura, T., Looney, D., Sharp, D. J., Papavassiliou, C., Morrell, M. J., & Mandic, D. P. (2017) · Scientific Reports · doi:10.1038/s41598-017-06925-2 · Cited by 159 · cited 1×
“While in-ear sensing of multiple physiological parameters has been demonstrated 24,25,29,30 , integrating both brain-state and metabolite monitoring in a single unobtrusive system has remained elusive due to the relatively large form factors of conventional electrochemical sensors.”
BackgroundAn Ear-Worn Vital Signs Monitor
He, D. D., Winokur, E. S., & Sodini, C. G. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2459061 · Cited by 113 · cited 2×
“Ecoflex 00–30 was purchased from Smooth-on.”
BackgroundKim, C., Joshi, S., Courellis, H., Wang, J., Miller, C., & Cauwenberghs, G. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2870555 · Cited by 104 · cited 1×
“…integration with our low-power, low-noise analogue front-end signal-amplification, filtering and acquisition integrated-circuit designs 47,48 , as well as clinical validation across a large population pool, promise to bring about an abundance of wearable diagnostic and therapeutic…”
BackgroundSelf-citationHuman pitch perception is reflected in the timing of stimulus-related cortical activity
Patel, A. D., & Balaban, E. (2001) · Nature Neuroscience · doi:10.1038/90557 · Cited by 82 · cited 1×
“Another widely studied evoked EEG pattern originating from the auditory cortex is the auditory steady-state response (ASSR), an ongoing oscillatory brain signal resulting from an acoustic stimulus’s continuous amplitude modulation 33 .”
BackgroundKaveh, R., Doong, J., Zhou, A., Schwendeman, C., Gopalan, K., Burghardt, F., Arias, A. C., Maharbiz, M. M., & Muller, R. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3001265 · Cited by 81 · cited 2×
“In-ear electrophysiological sensing systems 24,25 provide elegant solutions to unobtrusive brain-state monitoring inside the ear canal.”
BackgroundKalevo, L., Miettinen, T., Leino, A., Kainulainen, S., Korkalainen, H., Myllymaa, K., Töyräs, J., Leppänen, T., Laitinen, T. M., & Myllymaa, S. (2020) · IEEE Access · doi:10.1109/access.2020.2977172 · Cited by 72 · cited 1×
“This is in part due to interference present in the measured signals attributed to crosstalk between the sensors of dissimilar sensing modalities 21,22 and the disparity in optimal combined electrophysiological and electrochemical sensing (co-sensing) locations on the body, typically requiring…”
BackgroundPhysiological significance of elevated levels of lactate by exercise training in the brain and body
Lee, S., Choi, Y., Jeong, E., Park, J., Kim, J., Tanaka, M., & Choi, J. (2023) · Journal of Bioscience and Bioengineering · doi:10.1016/j.jbiosc.2022.12.001 · Cited by 67 · cited 1×
“Clinical evidence has further corroborated the conducive role of the monitoring and control of metabolite levels (such as those of lactate) in improving brain functions by enhancing neuroplasticity and angiogenesis 15,16 .”
BackgroundMasè, M., Micarelli, A., & Strapazzon, G. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.568886 · Cited by 65 · cited 1×
“In addition to access to physiological parameters, such as EEG, pulse rate and oxygen saturation 26 , it has multiple exocrine sweat glands for the analysis of vital metabolites 27 .”
BackgroundMultilayer Sweat-Absorbable Textile Electrode for EEG Measurement in Forehead Site
Shu, L., Xu, T., & Xu, X. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2912667 · Cited by 65 · cited 1×
“This is in part due to interference present in the measured signals attributed to crosstalk between the sensors of dissimilar sensing modalities 21,22 and the disparity in optimal combined electrophysiological and electrochemical sensing (co-sensing) locations on the body, typically requiring…”
BackgroundStoeckelhuber, M., Matthias, C., Andratschke, M., Stoeckelhuber, B. M., Koehler, C., Herzmann, S., Sulz, A., & WELSCH, U. N. (2006) · The Anatomical Record Part A Discoveries in Molecular Cellular and Evolutionary Biology · doi:10.1002/ar.a.20356 · Cited by 51 · cited 1×
“In addition to access to physiological parameters, such as EEG, pulse rate and oxygen saturation 26 , it has multiple exocrine sweat glands for the analysis of vital metabolites 27 .”
BackgroundA EOG-based switch and its application for “start/stop” control of a wheelchair
Li, Y., He, S., Huang, Q., Gu, Z., & Yu, Z. L. (2017) · Neurocomputing · doi:10.1016/j.neucom.2017.09.085 · Cited by 49 · cited 1×
“…sensing modality available in the ear is eye movement characterized by electrooculography (EOG), often considered as artefacts in EEG measurements 34 while finding utility for some BCI applications including drowsiness detection 35 , eye vergence therapy 36 and motor control 37,38 .”
BackgroundA Bidirectional Neural Interface SoC With Adaptive IIR Stimulation Artifact Cancelers
Samiei, A., & Hashemi, H. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3056040 · Cited by 49 · cited 1×
“The third solution is to apply front-end mitigation techniques 50 .”
MethodAlves, O. L., Bullock, R., Clausen, T., Reinert, M., & Reeves, T. M. (2005) · Journal of Neurotrauma · doi:10.1089/neu.2005.22.733 · Cited by 48
Gao, K., Shen, G., Zhao, N., Jiang, C., Yang, B. T., & Liu, J. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2987969 · Cited by 44 · cited 1×
“…the sensors of dissimilar sensing modalities 21,22 and the disparity in optimal combined electrophysiological and electrochemical sensing (co-sensing) locations on the body, typically requiring extensive form factors spanning a wide area across the body, such as in an EEG headset or headband 23 .”
BackgroundDoğan, E. A., Ünal, A., Ünal, A., & Erdoğan, Ç. (2017) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2017.07.003 · Cited by 42 · cited 1×
“For instance, lactate monitoring has been found to complement electroencephalogram (EEG) recording for the differentiation of generalized epileptic seizures from psychogenic non-epileptic and syncopal events in monitoring epileptic seizures 13,14 .”
BackgroundHuang, J., & Mercier, P. P. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3112635 · Cited by 42 · cited 1×
“…integration with our low-power, low-noise analogue front-end signal-amplification, filtering and acquisition integrated-circuit designs 47,48 , as well as clinical validation across a large population pool, promise to bring about an abundance of wearable diagnostic and therapeutic…”
BackgroundSelf-citationHearables: Here come the: Technology tucked inside your ears will augment your daily life
Crum, P. (2019) · IEEE Spectrum · doi:10.1109/mspec.2019.8701198 · Cited by 40 · cited 1×
“Due to the extremely limited space in the ear and large anatomical variations across ears, developing a user-generic ear sensor covering a broad range of biophysical modalities of interest to general health monitoring is still an extremely challenging goal 28 .”
BackgroundMatz, O., Heckelmann, J., Zechbauer, S., Litmathe, J., Brokmann, J. C., Willmes, K., Schulz, J. B., & Dafotakis, M. (2017) · Internal and Emergency Medicine · doi:10.1007/s11739-017-1745-2 · Cited by 39 · cited 1×
“For instance, lactate monitoring has been found to complement electroencephalogram (EEG) recording for the differentiation of generalized epileptic seizures from psychogenic non-epileptic and syncopal events in monitoring epileptic seizures 13,14 .”
BackgroundFechir, M., Schlereth, T., Kritzmann, S., Balon, S., Pfeifer, N., Geber, C., Breimhorst, M., Eberle, T., Gamer, M., & Birklein, F. (2009) · European Journal of Pain · doi:10.1016/j.ejpain.2008.11.002 · Cited by 37 · cited 1×
“…12 , can trigger characteristic patterns in both electrophysiological brain-state monitoring and produce abnormal https://doi.org/10.1038/s41551-023-01095-1 their relevance in a variety of health-related contexts, including traumatic brain injuries 31 and stress variation during the day 10,32 .”
BackgroundInfluentialVariation in Normal Ear Temperature
Sund‐Levander, M., & Grodzinsky, E. (2017) · The American Journal of the Medical Sciences · doi:10.1016/j.amjms.2017.05.013 · Cited by 27 · cited 1×
“The analytical performance of the electrochemical sensors at various temperatures and humidity levels, matching environmental and human physiological conditions in the ear 40,41 , has been evaluated for different lactate concentrations.”
BackgroundMatsumoto, K., Temiz, Y., Taghavi, H., Cornelius, E. L., Mori, H., & Michel, B. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856821 · Cited by 21 · cited 2×
“This behaviour is dependent on the sweat rate and is unique to every individual 42 , which can be seen in another recorded exercise session in different participants (Supplementary Fig.”
BackgroundAzgomi, H. F., Cajigas, I., & Faghih, R. T. (2021) · IEEE Access · doi:10.1109/access.2021.3099027 · Cited by 20 · cited 1×
“Previous medical studies have suggested that some of the day-to-day cognitive state variations such as stress 9 and emotions 10 , as well as neurodegenerative diseases, such as epilepsy 11 and Alzheimer’s disease 12 , can trigger characteristic patterns in both electrophysiological brain-state…”
BackgroundAttention State Classification with In-Ear EEG
Paul, A., Hota, G., Khaleghi, B., Xu, Y., Rosing, T., & Cauwenberghs, G. (2021) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas49922.2021.9644973 · Cited by 15 · cited 2×
“The FBCSP approach has been widely deployed as a classification algorithm for scalp-EEG motor imagery tasks 45,46 .”
BackgroundMethodSelf-citationJárdánházy, A., Járdánházy, T., & Kalman, J. L. (2008) · European Journal of Neurology · doi:10.1111/j.1468-1331.2007.02016.x · Cited by 8 · cited 1×
“…cognitive state variations such as stress 9 and emotions 10 , as well as neurodegenerative diseases, such as epilepsy 11 and Alzheimer’s disease 12 , can trigger characteristic patterns in both electrophysiological brain-state monitoring and produce abnormal…”
BackgroundRosa, B. M. G., Anastasova, S., & Yang, G. (2019) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2019.8918971 · Cited by 4 · cited 1×
“In addition, despite the extensive evidence supporting their isolated analysis studies, the integration of these two sensing modalities within a single wearable technology still presents a major challenge 20 .”
Background
Cited by
Hybrid multimodal wearable sensors for comprehensive health monitoring
Mahato, K., Saha, T., Ding, S., Sandhu, S. S., Chang, A.-Y., & Wang, J. (2024) · Nature Electronics · doi:10.1038/s41928-024-01247-4 · Cited by 404
Self-citationZhang, Y., Wei, G., Liu, W., Li, T., Wang, Y., Zhou, M., Liu, Y., Wang, X., & Wei, H. (2024) · Nature Reviews Methods Primers · doi:10.1038/s43586-024-00315-5 · Cited by 350
Applied body-fluid analysis by wearable devices
Brasier, N., Wang, J., Gao, W., Sempionatto, J. R., Dincer, C., Ates, H. C., Güder, F., Olenik, S., Schauwecker, I., Schaffarczyk, D., et al. (2024) · Nature · doi:10.1038/s41586-024-08249-4 · Cited by 298
Self-citationMotion artefact management for soft bioelectronics
Yin, J., Wang, S., Tat, T., & Chen, J. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00175-4 · Cited by 220
“Such differences should be considered in the design of soft bioelectronics 213–218 .”
Chen, S., Fan, S., Qiao, Z., Wu, Z., Lin, B., Li, Z., Riegler, M. A., Wong, M. Y. H., Opheim, A., Korostynska, O., et al. (2025) · Advanced Materials · doi:10.1002/adma.202500412 · Cited by 164
Metadata
- Authors
- Xu, Y., De la Paz, E., Paul, A., Mahato, K., Sempionatto, J. R., Tostado, N., Lee, M., Hota, G., Lin, M., Uppal, A., Chen, W., Dua, S., Yin, L., Wuerstle, B. L., Deiss, S., Mercier, P., Xu, S., Wang, J., & Cauwenberghs, G.
- Venue
- Nature Biomedical Engineering
- Published
- 2023-09-28
- Volume
- 7
- Issue
- 10
- Pages
- 1307-1320
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W4387130473
- Cited by
- 175
- References
- 48
- FWCI
- 12.84
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.