Gyrocardiography: A New Non-invasive Monitoring Method for the Assessment of Cardiac Mechanics and the Estimation of Hemodynamic Variables
Open accessThe DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
Gyrocardiography (GCG) is a new non-invasive technique for assessing heart motions by using a sensor of angular motion – gyroscope – attached to the skin of the chest. In this study, we conducted simultaneous recordings of electrocardiography (ECG), GCG, and echocardiography in a group of subjects consisting of nine healthy volunteer men. Annotation of underlying fiducial points in GCG is presented and compared to opening and closing points of heart valves measured by a pulse wave Doppler. Comparison between GCG and synchronized tissue Doppler imaging (TDI) data shows that the GCG signal is also capable of providing temporal information on the systolic and early diastolic peak velocities of the myocardium. Furthermore, time intervals from the ECG Q-wave to the maximum of the integrated GCG (angular displacement) signal and maximal myocardial strain curves obtained by 3D speckle tracking are correlated. We see GCG as a promising mechanical cardiac monitoring tool that enables quantification of beat-by-beat dynamics of systolic time intervals (STI) related to hemodynamic variables and myocardial contractility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Ultrastructural Characterization of the Lower Motor System in a Mouse Model of Krabbe Disease
Cappello, V., Marchetti, L., Parlanti, P., Landi, S., Tonazzini, I., Cecchini, M., Piazza, V., & Gemmi, M. (2016) · Scientific Reports · doi:10.1038/s41598-016-0001-8 · Cited by 13,097
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 1×
“Precision or PPV (%) = TP TP+FP ×100, (2)”
Noninvasive Myocardial Strain Measurement by Speckle Tracking Echocardiography
Amundsen, B. H., Helle-Valle, T., Edvardsen, T., Torp, H., Crosby, J., Lyseggen, E., Støylen, A., Ihlen, H., Lima, J. A. C., Smiseth, O. A., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.10.040 · Cited by 1,252
Systolic Time Intervals in Heart Failure in Man
WEISSLER, A. M., HARRIS, W. S., & SCHOENFELD, C. D. (1968) · Circulation · doi:10.1161/01.cir.37.2.149 · Cited by 1,217
Ballistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775
Reconfigurable Complementary Logic Circuits with Ambipolar Organic Transistors
Yoo, H., Ghittorelli, M., Smits, E. C. P., Gelinck, G. H., Lee, H.-K., Torricelli, F., & Kim, J.-J. (2016) · Scientific Reports · doi:10.1038/srep35585 · Cited by 525
GARRARD, C. L., WEISSLER, A. M., & DODGE, H. T. (1970) · Circulation · doi:10.1161/01.cir.42.3.455 · Cited by 450
Moore, C. C., Lugo-Olivieri, C. H., McVeigh, E. R., & Zerhouni, E. A. (2000) · Radiology · doi:10.1148/radiology.214.2.r00fe17453 · Cited by 421
Starr, I., Rawson, A. J., Schroeder, H. A., & Joseph, N. R. (1939) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1939.127.1.1 · Cited by 398
Waldman, L. K., Fung, Y. C., & Covell, J. W. (1985) · Circulation Research · doi:10.1161/01.res.57.1.152 · Cited by 363
Dissociation between left ventricular untwisting and filling. Accentuation by catecholamines.
Rademakers, F. E., Buchalter, M. B., Rogers, W. J., Zerhouni, E. A., Weisfeldt, M. L., Weiss, J. L., & Shapiro, E. P. (1992) · Circulation · doi:10.1161/01.cir.85.4.1572 · Cited by 346
Haugaa, K. H., Smedsrud, M. K., Steen, T., Kongsgaard, E., Loennechen, J. P., Skjaerpe, T., Voigt, J.-U., Willems, R., Smith, G., Smiseth, O. A., et al. (2010) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2009.11.012 · Cited by 307
The Journal of Anatomy and Physiology
(1898) · Nature · doi:10.1038/057318b0 · Cited by 300
Ingels, N. B., Daughters, G. T., Stinson, E. B., & Alderman, E. L. (1975) · Circulation · doi:10.1161/01.cir.52.5.859 · Cited by 248
JACC: Cardiovascular Imaging 2.0
Chandrashekhar, Y., & Fuster, V. (2018) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2018.03.005 · Cited by 241
Notomi, Y., Setser, R. M., Shiota, T., Martin-Miklovic, M. G., Weaver, J. A., Popović, Z. B., Yamada, H., Greenberg, N. L., White, R. D., & Thomas, J. D. (2005) · Circulation · doi:10.1161/01.cir.0000157151.10971.98 · Cited by 235
Mechanics of ventricular torsion
Taber, L. A., Yang, M., & Podszus, W. W. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00129-8 · Cited by 225
Certain Molar Movements of the Human Body produced by the Circulation of the Blood.
Jw, G. (1877) · Europe PMC (PubMed Central) · Cited by 197
Ballistocardiogram: Mechanism and Potential for Unobtrusive Cardiovascular Health Monitoring
Kim, C.-S., Ober, S. L., McMurtry, M. S., Finegan, B. A., Inan, O. T., Mukkamala, R., & Hahn, J.-O. (2016) · Scientific Reports · doi:10.1038/srep31297 · Cited by 195
Novel Wireless Devices for Cardiac Monitoring
Walsh, J. A., Topol, E. J., & Steinhubl, S. R. (2014) · Circulation · doi:10.1161/circulationaha.114.009024 · Cited by 175
Di Rienzo, M., Vaini, E., Castiglioni, P., Merati, G., Meriggi, P., Parati, G., Faini, A., & Rizzo, F. (2013) · Autonomic Neuroscience · doi:10.1016/j.autneu.2013.04.005 · Cited by 163
Seismocardiography: Past, present and future
Zanetti, J. M., & Tavakolian, K. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6611170 · Cited by 152
Atrial Fibrillation Detection via Accelerometer and Gyroscope of a Smartphone
Lahdenoja, O., Pankaala, M., Koivisto, T., Hurnanen, T., Iftikhar, Z., Nieminen, S., Knuutila, T., Saraste, A., Kiviniemi, T., Vasankari, T., et al. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2688473 · Cited by 146
Self-citationAutomatic Detection of Atrial Fibrillation in Cardiac Vibration Signals
Brüser, C., Diesel, J., Zink, M. D., Winter, S., SCHAUERTE, P. N., & Leonhardt, S. K. (2012) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/titb.2012.2225067 · Cited by 133
BioGlass: Physiological parameter estimation using a head-mounted wearable device
Hernández, J., Li, Y., Rehg, J. M., & Picard, R. W. (2014) · 2014 4th International Conference on Wireless Mobile Communication and Healthcare - Transforming Healthcare Through Innovations in Mobile and Wireless Technologies (MOBIHEALTH) · doi:10.4108/icst.mobihealth.2014.257219 · Cited by 132
(2018) · Terapevticheskii arkhiv · doi:10.26442/terarkh · Cited by 127
Novel Approach to Measure Myocardial Performance Index: Pulsed‐Wave Tissue Doppler Echocardiography
Tekten, T., Onbaşılı, A., Ceyhan, C., Ünal, S., & Dışçıgıl, B. (2003) · Echocardiography · doi:10.1046/j.1540-8175.2003.03086.x · Cited by 121
A real-time approach for heart rate monitoring using a Hilbert transform in seismocardiograms
Tadi, M. J., Lehtonen, E., Hurnanen, T., Koskinen, J., Eriksson, J., Pänkäälä, M., Teräs, M., & Koivisto, T. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/11/1885 · Cited by 114 · cited 1×
“Sensitivity or TPR (%) = TP TP+FN ×100, (1)”
BackgroundSelf-citationSeismocardiography: a technique for recording precordial acceleration
Zanetti, J. M., & Salerno, D. M. (2002) · [1991] Computer-Based Medical Systems@m_Proceedings of the Fourth Annual IEEE Symposium · doi:10.1109/cbms.1991.128936 · Cited by 103
Automated Detection of Atrial Fibrillation Based on Time–Frequency Analysis of Seismocardiograms
Hurnanen, T., Lehtonen, E., Tadi, M. J., Kuusela, T., Kiviniemi, T., Saraste, A., Vasankari, T., Airaksinen, J. K. E., Koivisto, T., & Pänkäälä, M. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2621887 · Cited by 102
Self-citationEtemadi, M., Inan, O. T., Heller, J. A., Hersek, S., Klein, L., & Roy, S. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2405480 · Cited by 95
BioGlass: Physiological parameter estimation using a head-mounted wearable device
Hernandez, J., Li, Y., Rehg, J. M., & Picard, R. W. (2014) · SMARTech Repository (Georgia Institute of Technology) · doi:10.1109/mobihealth.2014.7015908 · Cited by 92
Automatic Annotation of Seismocardiogram With High-Frequency Precordial Accelerations
Khosrow-khavar, F., Tavakolian, K., Blaber, A. P., Zanetti, J. M., Fazel-Rezai, R., & Menon, C. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2360156 · Cited by 90
Khosrow-Khavar, F., Tavakolian, K., Blaber, A. P., & Menon, C. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2616382 · Cited by 90
Automatic Identification of Systolic Time Intervals in Seismocardiogram
Shafiq, G., Tatinati, S., Ang, W. T., & Veluvolu, K. C. (2016) · Scientific Reports · doi:10.1038/srep37524 · Cited by 75
An optical device to measure the dynamics of apex rotation of the left ventricle
Kroeker, C. A. G., ter Keurs, H. E. D. J., Knudtson, M. L., Tyberg, J. V., & Beyar, R. (1993) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1993.265.4.h1444 · Cited by 69
Salerno, D. M., Zanetti, J. M., Green, L. A., Mooney, M. R., Madison, J. D., & Tassel, R. A. V. (1991) · The American Journal of Cardiology · doi:10.1016/0002-9149(91)90744-6 · Cited by 68
[Seismocardiography--a new method in the study of functional conditions of the heart].
Bs, B. (1961) · PubMed · Cited by 60
Biophone: Physiology monitoring from peripheral smartphone motions
Hernandez, J., McDuff, D., & Picard, R. W. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7320048 · Cited by 58
A Hidden Markov Model for Seismocardiography
Wahlström, J., Skog, I., Händel, P., Khosrow-Khavar, F., Tavakolian, K., Stein, P. K., & Nehorai, A. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2648741 · Cited by 54
Myocardial contractility: A seismocardiography approach
Tavakolian, K., Portacio, G., Tamddondoust, N. R., Jahns, G., Ngai, B., Dumont, G. A., & Blaber, A. P. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346795 · Cited by 53
Becker, M., Roehl, A. B., Siekmann, U., Koch, A., de la Fuente, M., Roissant, R., Radermacher, K., Marx, N., & Hein, M. (2013) · Herz · doi:10.1007/s00059-013-3851-x · Cited by 42
Migeotte, P., Mucci, V., Delière, Q., Lejeune, L., & van de Borne, P. (2016) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-319-32703-7_220 · Cited by 33
An optical device to measure the dynamics of apex rotation of the left ventricle
Beyar, R., Kroeker, C. A. G., ter Keurs, H. E. D. J., Knudtson, M. L., & Tyberg, J. V. (1992) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1992.5761048 · Cited by 31
Heart Rate Variability Estimation with Joint Accelerometer and Gyroscope Sensing
Lahdenoja, O., Hurnanen, T., Tadi, M. J., Pänkäälä, M., & Koivisto, T. (2016) · Computing in cardiology · doi:10.22489/cinc.2016.209-166 · Cited by 30
Self-citationA smartphone-only solution for detecting indications of acute myocardial infarction
Lahdenoja, O., Koivisto, T., Tadi, M. J., Iftikhar, Z., Hurnanen, T., Vasankari, T., Kiviniemi, T., Airaksinen, J. K. E., & Pänkäälä, M. (2017) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi.2017.7897239 · Cited by 28
Self-citationFirst Experimental Evaluation of Cardiac Apex Rotation with an Epicardial Coriolis Force Sensor
Marcelli, E., Plicchi, G., Cercenelli, L., & Bortolami, F. (2005) · ASAIO Journal · doi:10.1097/01.mat.0000179250.52117.5c · Cited by 24
Tadi, M. J., Koivisto, T., Pänkäälä, M., Paasio, A., Knuutila, T., Teräs, M., & Hanninen, P. E. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2179346 · Cited by 23
Self-citationEstimation of heart rate from a chest-worn inertial measurement unit
Jia, W., Li, Y., Bai, Y., Mao, Z., Sun, M., & Zhao, Q. (2015) · International Symposium on Bioelectronics and Bioinformatics (ISBB) · doi:10.1109/isbb.2015.7344945 · Cited by 21
Annotation of seismocardiogram using gyroscopic recordings
Yang, C., Tang, S., & Tavassolian, N. (2016) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2016.7833767 · Cited by 15
Effect of Right Ventricular Pacing on Cardiac Apex Rotation Assessed by a Gyroscopic Sensor
Marcelli, E., Cercenelli, L., Parlapiano, M., Fumero, R., Bagnoli, P., Costantino, M. L., & Plicchi, G. (2007) · ASAIO Journal · doi:10.1097/mat.0b013e31805370e3 · Cited by 15
Tuominen, J., Lehtonen, E., Tadi, M. J., Koskinen, J., Pänkäälä, M., & Koivisto, T. (2017) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2017.8050684 · Cited by 13
Self-citationA Miniaturized MEMS Motion Processing System for Nuclear Medicine Imaging Applications
Tadi, M. J., Lehtonen, E., Teuho, J., Saraste, A., Pänkäälä, M., Teräs, M., & Koivisto, T. (2016) · Computing in cardiology · doi:10.22489/cinc.2016.042-452 · Cited by 8
Self-citation
Cited by
Lee, K., Ni, X., Lee, J. Y., Arafa, H., Pe, D. J., Xu, S., Avila, R., Irie, M., Lee, J. H., Easterlin, R. L., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0480-6 · Cited by 349
“…capabilities in this context, with demonstrated examples in capturing signatures of cardiac mechanics such as seismocardiograms or ballistocardiograms 11–14 , respiratory rate and sounds 15–21 , sounds of swallowing 22–25 , vocals 26,27 , changes in body position and motion 28–30 and others 31 .”
Recent Advances in Seismocardiography
Taebi, A., Solar, B. E., Bomar, A. J., Sandler, R. H., & Mansy, H. A. (2019) · Vibration · doi:10.3390/vibration2010005 · Cited by 276
Ballistocardiogram signal processing: a review
Sadek, I., Biswas, J., & Abdulrazak, B. (2019) · Health Information Science and Systems · doi:10.1007/s13755-019-0071-7 · Cited by 216
“Microelectromechanical (MEMS) gyroscope sensor is another attractive device that can measure the angular ballistograph signal that is indicative of rotational movement of a chest of a subject [11].”
BackgroundMulti‐Mode/Signal Biosensors: Electrochemical Integrated Sensing Techniques
Han, Q., Wang, H., & Wang, J. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202403122 · Cited by 165
A Unified Framework for Quality Indexing and Classification of Seismocardiogram Signals
Zia, J., Kimball, J., Hersek, S., Shandhi, M. M. H., Semiz, B., & Inan, O. T. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2931348 · Cited by 48
“the gyroscope-based measurements from the sternum may also be referred to as gyrocardiography, or GCG, signals [17].”
Background
Metadata
- Authors
- Jafari Tadi, M., Lehtonen, E., Saraste, A., Tuominen, J., Koskinen, J., Teräs, M., Airaksinen, J., Pänkäälä, M., & Koivisto, T.
- Venue
- Scientific Reports
- Published
- 2017-07-28
- Volume
- 7
- Issue
- 1
- Pages
- 6823-6823
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2736364367
- Cited by
- 174
- References
- 54
- FWCI
- 6.75
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.