Carbon fiber based electrochemical sensor for sweat cortisol measurement
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
This study examines the use of a conductive carbon fiber to construct a flexible biosensing platform for monitoring biomarkers in sweat. Cortisol was chosen as a model analyte. Functionalization of the conductive carbon yarn (CCY) with ellipsoidal Fe 2 O 3 has been performed to immobilize the antibodies specific to cortisol. 1-Ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) and N-Hydroxysuccinimide (NHS) chemistry has been used to immobilize the antibodies onto the Fe 2 O 3 modified CCY. Crystallinity, structure, morphology, flexibility, surface area, and elemental analysis were studied using X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), Raman spectroscopy, Field emission scanning electron microscopy with energy dispersive X-ray spectroscopy (FE-SEM/EDS) and Brunauer–Emmett–Teller (BET) analysis. Mechanical properties of the fiber such as tensile strength, young’s modulus have also been investigated. Under optimal parameters, the fabric sensor exhibited a good linearity (r 2 = 0.998) for wide a linear range from 1 fg to 1 μg with a detection limit of 0.005 fg/mL for the sensitive detection of cortisol. Repeatability, reliability, reproducibility, and anti-interference properties of the current sensor have been investigated. Detection of cortisol levels in human sweat samples has also been investigated and the results were validated with commercial chemiluminescence immunoassay (CLIA) method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of stress throughout the lifespan on the brain, behaviour and cognition
Lupien, S. J., McEwen, B. S., Gunnar, M. R., & Heim, C. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2639 · Cited by 6,256
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Review Carbon fibers for composites
Chand, S. (2000) · Journal of Materials Science · doi:10.1023/a:1004780301489 · Cited by 916
Shim, B. S., Chen, W., Doty, C., Xu, C., & Kotov, N. A. (2008) · Nano Letters · doi:10.1021/nl801495p · Cited by 536
A wearable multisensing patch for continuous sweat monitoring
Anastasova, S., Crewther, B., Bembnowicz, P., Curto, V., Ip, H. M., Rosa, B., & Yang, G.-Z. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.038 · Cited by 443
Biosensors for cardiac biomarkers detection: A review
Qureshi, A., Gurbuz, Y., & Niazi, J. H. (2012) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2012.05.077 · Cited by 409
Recent advances in cortisol sensing technologies for point-of-care application
Kaushik, A., Vasudev, A., Arya, S. K., Pasha, S. K., & Bhansali, S. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.09.060 · Cited by 316
Self-citationJian, Z., Zhao, B., Liu, P., Li, F., Zheng, M., Chen, M. W., Shi, Y., & Zhou, H. S. (2013) · Chemical Communications · doi:10.1039/c3cc47977c · Cited by 314
A wearable electrochemical sensor for the real-time measurement of sweat sodium concentration
Schazmann, B., Morris, D., Slater, C., Beirne, S., Fay, C., Reuveny, R., Moyna, N., & Diamond, D. (2010) · Analytical Methods · doi:10.1039/b9ay00184k · Cited by 286
The Detection of Cortisol in Human Sweat: Implications for Measurement of Cortisol in Hair
Russell, E., Koren, G., Rieder, M., & Van Uum, S. H. M. (2014) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e31829daa0a · Cited by 193
Stevens, R. C., Soelberg, S. D., Near, S., & Furlong, C. E. (2008) · Analytical Chemistry · doi:10.1021/ac800892h · Cited by 179
Psychosocial Stress and Cardiovascular Disease: Pathophysiological Links
Merz, C. N. B., Dwyer, J., Nordstrom, C. K., Walton, K. G., Salerno, J. W., & Schneider, R. H. (2002) · Behavioral Medicine · doi:10.1080/08964280209596039 · Cited by 176
Fe2O3-Graphene Rice-on-Sheet Nanocomposite for High and Fast Lithium Ion Storage
Zou, Y., Kan, J., & Wang, Y. (2011) · The Journal of Physical Chemistry C · doi:10.1021/jp206876t · Cited by 172
Flexible heartbeat sensor for wearable device
Kwak, Y. H., Kim, W.-H., Park, K.-B., Kim, K., & Seo, S. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.03.016 · Cited by 156
Vabbina, P. K., Kaushik, A. K., Pokhrel, N., Bhansali, S., & Pala, N. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.026 · Cited by 155
Self-citationFlexible and conductive nanofiber-structured single yarn sensor for smart wearable devices
Wu, S., Liu, P., Zhang, Y., Zhang, H., & Qin, X. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.06.062 · Cited by 149
Biomarkers of Psychological Stress in Health Disparities Research
Djuric, Z., Bird, C. E., Furumoto-Dawson, A., Rauscher, G. H., Ruffin IV, M. T., Stowe, R. P., Tucker, K. L., & Masi, C. M. (2008) · The Open Biomarkers Journal · doi:10.2174/1875318300801010007 · Cited by 144
Flexible nanoporous tunable electrical double layer biosensors for sweat diagnostics
Munje, R. D., Muthukumar, S., Panneer Selvam, A., & Prasad, S. (2015) · Scientific Reports · doi:10.1038/srep14586 · Cited by 138
Chen, L., Yu, Z., Ma, X., Li, Z., & Yu, S. (2014) · Nano Energy · doi:10.1016/j.nanoen.2014.07.021 · Cited by 135
Label-free, chemiresistor immunosensor for stress biomarker cortisol in saliva
Tlili, C., Myung, N. V., Shetty, V., & Mulchandani, A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.04.045 · Cited by 126
Sun, B., Gou, Y., Ma, Y., Zheng, X., Bai, R., Abdelmoaty, A. A. A., & Hu, F. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.07.047 · Cited by 119
Arya, S. K., Dey, A., & Bhansali, S. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.07.015 · Cited by 118
Self-citationArya, S. K., Chornokur, G., Venugopal, M., & Bhansali, S. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.03.016 · Cited by 115
Self-citationCapillary Electrophoresis-Based Immunoassay for Cortisol in Serum
Schmalzing, D., Nashabeh, W., Yao, X.-W., Mhatre, R., Regnier, F. E., Afeyan, N. B., & Fuchs, M. (1995) · Analytical Chemistry · doi:10.1021/ac00099a019 · Cited by 104
Shimada, M., Takahashi, K., Ohkawa, T., Segawa, M., & Higurashi, M. (1995) · Hormone Research · doi:10.1159/000184628 · Cited by 101
A realtime and continuous assessment of cortisol in ISF using electrochemical impedance spectroscopy
Venugopal, M., Arya, S. K., Chornokur, G., & Bhansali, S. (2011) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2011.04.028 · Cited by 100
Self-citationMicrowave-Assisted Hydrothermal Synthesis of Nanosized α-Fe2O3 for Catalysts and Adsorbents
Qiu, G., Huang, H., Genuino, H., Opembe, N., Stafford, L., Dharmarathna, S., & Suib, S. L. (2011) · The Journal of Physical Chemistry C · doi:10.1021/jp2067217 · Cited by 97
Dey, A., Kaushik, A. K., Arya, S. K., & Bhansali, S. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm31663c · Cited by 83
Self-citationFernandez, R. E., Umasankar, Y., Manickam, P., Nickel, J. C., Iwasaki, L. R., Kawamoto, B., Todoki, K. C., Scott, J. M., & Bhansali, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-17835-8 · Cited by 81
Self-citationManickam, P., Pasha, S. K., Snipes, S. A., & Bhansali, S. (2017) · Journal of The Electrochemical Society · doi:10.1149/2.0781702jes · Cited by 78
Self-citationBiomarcadores en la medicina cardiovascular
Martín-Ventura, J. L., Blanco‐Colio, L. M., Tuñón, J., Muñoz‐García, B., Madrigal‐Matute, J., Moreno, J. A., de Céniga, M. V., & Egido, J. (2009) · Revista Española de Cardiología · doi:10.1016/s0300-8932(09)71335-1 · Cited by 75
Kim, K. S., Ryeol, L. S., Kim, S., Lee, J. Y., Chung, C., Choe, W., & Yoo, P. J. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.09.135 · Cited by 69
Biomarkers in Cardiovascular Medicine
Martín-Ventura, J. L., Blanco‐Colio, L. M., Tuñón, J., Muñoz‐García, B., Madrigal‐Matute, J., Moreno, J. A., de Céniga, M. V., & Egido, J. (2009) · Revista Española de Cardiología (English Edition) · doi:10.1016/s1885-5857(09)72232-7 · Cited by 65 · cited 1×
“− I ( A) 1 148x 52 468 (mVs ); R 0 9971 (2) pc 1 2 Figure 6.”
Gatti, R., Cappellin, E., Zecchin, B., Antonelli, G., Spinella, P., Mantero, F., & Palo, E. F. D. (2005) · Journal of Chromatography B · doi:10.1016/j.jchromb.2005.06.037 · Cited by 62
Mahesh, K. P. O., Shown, I., Chen, L., Chen, K., & Tai, Y. (2017) · Applied Surface Science · doi:10.1016/j.apsusc.2017.08.168 · Cited by 61
Kaushik, A. K., Vasudev, A., Arya, S. K., & Bhansali, S. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.06.012 · Cited by 61
Self-citationWearable Biosensors for Monitoring Wound Healing
Pasche, S., Angeloni, S., Ischer, R., Liley, M., Luprano, J., & Voirin, G. (2008) · Advances in Science and Technology · doi:10.4028/www.scientific.net/ast.57.80 · Cited by 60
Disposable immunosensor for cortisol using functionalized magnetic particles
Moreno‐Guzmán, M., Eguílaz, M., Campuzano, S., González-Cortés, A., Yáñez‐Sedeño, P., & Pingarrón, J. M. (2010) · The Analyst · doi:10.1039/c0an00206b · Cited by 54
Xu, Y., Yang, S., Zhang, G., Sun, Y., Gao, D., & Sun, Y. (2011) · Materials Letters · doi:10.1016/j.matlet.2011.03.085 · Cited by 54
Sun, C., Chen, S., & Li, Z. (2017) · Applied Surface Science · doi:10.1016/j.apsusc.2017.08.070 · Cited by 52
A fluorimetric assay for cortisol
Appel, D., Schmid, R. D., Drăgan, C.-A., Bureik, M., & Urlacher, V. B. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-0022-9 · Cited by 51
Immunoassays for cortisol using antibody-doped sol–gel silica
Zhou, J. C., Chuang, M. H., Lan, E. H., Dunn, B., Gillman, P. L., & Smith, S. M. (2004) · Journal of Materials Chemistry · doi:10.1039/b401902d · Cited by 47
Oka, K., Noguchi, M., Kitamura, T., & Shima, S. (1987) · Clinical Chemistry · doi:10.1093/clinchem/33.9.1639 · Cited by 40
Physical stimuli and emotional stress-induced sweat secretions in the human palm and forehead
Kamei, T., Tsuda, T., Kitagawa, S., Naitoh, K., Nakashima, K., & Ohhashi, T. (1998) · Analytica Chimica Acta · doi:10.1016/s0003-2670(97)00642-9 · Cited by 38
Liu, X., Zhao, R., Mao, W., Feng, H., Liu, X., & Wong, D. K. Y. (2011) · The Analyst · doi:10.1039/c1an15411g · Cited by 30
Madhu, S., Manickam, P., Pierre, M., Bhansali, S., Ponpandian, N., & Viswanathan, C. (2017) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2017.11.046 · Cited by 28
Self-citationSarkar, M., Das, B., Borah, B. D., Kumar, V., Mohan, K., Meyer, H. H. D., & Prakash, B. S. (2007) · General and Comparative Endocrinology · doi:10.1016/j.ygcen.2007.05.035 · Cited by 23
Sarkar, M., Borah, B., MEYER, H. H. D., & Prakash, B. S. (2008) · General and Comparative Endocrinology · doi:10.1016/j.ygcen.2008.07.007 · Cited by 20
Fabric Based Wearable Biosensor for Continuous Monitoring of Steroids
Manickam, P., Madhu, S., Fernandez, R. E., Viswanathan, C., & Bhansali, S. (2017) · ECS Transactions · doi:10.1149/07711.1841ecst · Cited by 16
Self-citation
Cited by
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Skin in the diagnostics game: Wearable biosensor nano- and microsystems for medical diagnostics
Dervisevic, M., Alba, M., Prieto-Simon, B., & Voelcker, N. H. (2020) · Nano Today · doi:10.1016/j.nantod.2019.100828 · Cited by 203
State of Sweat: Emerging Wearable Systems for Real-Time, Noninvasive Sweat Sensing and Analytics
Ghaffari, R., Yang, D. S., Kim, J., Mansour, A., Wright, J. A., Model, J. B., Wright, D. E., Rogers, J. A., & Ray, T. R. (2021) · ACS Sensors · doi:10.1021/acssensors.1c01133 · Cited by 178
“Other wearable sensor designs seek to harness blood-correlated biomarkers beyond chloride and glucose (e.g. lactate 161-165 , ethanol 156 , cortisol 166,167 ) to address diagnostic challenges related to diabetes and other diseases.”
Extended gate field-effect-transistor for sensing cortisol stress hormone
Sheibani, S., Capua, L., Kamaei, S., Akbari, S. S. A., Zhang, J., Guerin, H., & Ionescu, A. M. (2021) · Communications Materials · doi:10.1038/s43246-020-00114-x · Cited by 158
Stress Monitoring and Recent Advancements in Wearable Biosensors
Samson, C., & Koh, A. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.01037 · Cited by 129
“Other skin-interfaced sensing platforms are in development, indicating a trend toward flexible sensing (Sekar et al., 2019; Kim et al., 2020).”
Background
Metadata
- Authors
- Sekar, M., Pandiaraj, M., Bhansali, S., Ponpandian, N., & Viswanathan, C.
- Venue
- Scientific Reports
- Published
- 2019-01-23
- Volume
- 9
- Issue
- 1
- Pages
- 403-403
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2920506563
- Cited by
- 161
- References
- 49
- FWCI
- 6.34
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.