Low-cost portable microwave sensor for non-invasive monitoring of blood glucose level: novel design utilizing a four-cell CSRR hexagonal configuration
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
This article presents a novel design of portable planar microwave sensor for fast, accurate, and non-invasive monitoring of the blood glucose level as an effective technique for diabetes control and prevention. The proposed sensor design incorporates four cells of hexagonal-shaped complementary split ring resonators (CSRRs), arranged in a honey-cell configuration, and fabricated on a thin sheet of an FR4 dielectric substrate.The CSRR sensing elements are coupled via a planar microstrip-line to a radar board operating in the ISM band 2.4–2.5 GHz. The integrated sensor shows an impressive detection capability and a remarkable sensitivity of blood glucose levels (BGLs). The superior detection capability is attributed to the enhanced design of the CSRR sensing elements that expose the glucose samples to an intense interaction with the electromagnetic fields highly concentrated around the sensing region at the induced resonances. This feature enables the developed sensor to detect extremely delicate variations in the electromagnetic properties that characterize the varying-level glucose samples. The desired performance of the fabricated sensor is practically validated through in-vitro measurements using a convenient setup of Vector Network Analyzer (VNA) that records notable traces of frequency-shift responses when the sensor is loaded with samples of 70–120 mg/dL glucose concentrations. This is also demonstrated in the radar-driven prototype where the raw data collected at the radar receiving channel shows obvious patterns that reflect glucose-level variations. Furthermore, the differences in the sensor responses for tested glucose samples are quantified by applying the Principal Component Analysis (PCA) machine learning algorithm. The proposed sensor, beside its impressive detection capability of the diabetes-spectrum glucose levels, has several other favorable attributes including compact size, simple fabrication, affordable cost, non-ionizing nature, and minimum health risk or impact. Such attractive features promote the proposed sensor as a possible candidate for non-invasive glucose levels monitoring for diabetes as evidenced by the preliminary results from a proof-of-concept in-vivo experiment of tracking an individual’s BGL by placing his fingertip onto the sensor. The presented system is a developmental platform towards radar-driven wearable continuous BGL monitors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnosis and Classification of Diabetes Mellitus
American Diabetes Association (2011) · Diabetes Care · doi:10.2337/dc11-s062 · Cited by 13,988
Abdi, H., & Williams, L. J. (2010) · WIREs Computational Statistics · doi:10.1002/wics.101 · Cited by 11,104
IDF Diabetes Atlas: Global estimates for the prevalence of diabetes for 2015 and 2040
Ogurtsova, K., da Rocha Fernandes, J. D., Huang, Y., Linnenkamp, U., Guariguata, L., Cho, N. H., Cavan, D., Shaw, J. E., & Makaroff, L. E. (2017) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.03.024 · Cited by 6,966
Diagnosis and classification of diabetes mellitus
American Diabetes Association (2014) · Diabetes Care · doi:10.2337/dc14-s081 · Cited by 5,974
IDF Diabetes Atlas: Global estimates of the prevalence of diabetes for 2011 and 2030
Whiting, D. R., Guariguata, L., Weil, C., & Shaw, J. (2011) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2011.10.029 · Cited by 3,994
Baena, J. D., Bonache, J., Martin, F., Sillero, R. M., Falcone, F., Lopetegi, T., Laso, M. A. G., Garcia-Garcia, J., Gil, I., Portillo, M. F., et al. (2005) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2005.845211 · Cited by 1,624
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Villena Gonzales, W., Mobashsher, A., & Abbosh, A. (2019) · Sensors · doi:10.3390/s19040800 · Cited by 772
Wearable non-invasive epidermal glucose sensors: A review
Kim, J., Campbell, A. S., & Wang, J. (2018) · Talanta · doi:10.1016/j.talanta.2017.08.077 · Cited by 586
Prediabetes diagnosis and treatment: A review
Bansal, N. (2015) · World Journal of Diabetes · doi:10.4239/wjd.v6.i2.296 · Cited by 579
Non-invasive glucose monitoring technology in diabetes management: A review
Vashist, S. K. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.043 · Cited by 575
Metamaterials Application in Sensing
Chen, T., Li, S., & Sun, H. (2012) · Sensors · doi:10.3390/s120302742 · Cited by 557
Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy
Yadav, J., Rani, A., Singh, V., & Murari, B. M. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.01.005 · Cited by 374
Lipani, L., Dupont, B. G. R., Doungmene, F., Marken, F., Tyrrell, R. M., Guy, R. H., & Ilie, A. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0112-4 · Cited by 340
Eyeglasses-based tear biosensing system: Non-invasive detection of alcohol, vitamins and glucose
Sempionatto, J. R., Brazaca, L. C., García-Carmona, L., Bolat, G., Campbell, A. S., Martin, A., Tang, G., Shah, R., Mishra, R. K., Kim, J., et al. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.04.058 · Cited by 315
Design and In Vitro Interference Test of Microwave Noninvasive Blood Glucose Monitoring Sensor
Choi, H., Naylon, J., Luzio, S., Beutler, J., Birchall, J., Martin, C., & Porch, A. (2015) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2015.2472019 · Cited by 312
Microwave-Based Noninvasive Concentration Measurements for Biomedical Applications
Hofmann, M., Fischer, G., Weigel, R., & Kissinger, D. (2013) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2013.2250516 · Cited by 288
Karpova, E. V., Shcherbacheva, E. V., Galushin, A. A., Vokhmyanina, D. V., Karyakina, E. E., & Karyakin, A. A. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05928 · Cited by 242
Radio-Frequency and Microwave Techniques for Non-Invasive Measurement of Blood Glucose Levels
Yilmaz, T., Foster, R., & Hao, Y. (2019) · Diagnostics · doi:10.3390/diagnostics9010006 · Cited by 192
de Castro, L. F., de Freitas, S. V., Duarte, L. C., de Souza, J. A. C., Paixão, T. R. L. C., & Coltro, W. K. T. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-01788-0 · Cited by 184
Juan, C. G., Bronchalo, E., Potelon, B., Quendo, C., Avila-Navarro, E., & Sabater-Navarro, J. M. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2866743 · Cited by 177
Saha, S., Cano-Garcia, H., Sotiriou, I., Lipscombe, O., Gouzouasis, I., Koutsoupidou, M., Palikaras, G., Mackenzie, R., Reeve, T., Kosmas, P., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-06926-1 · Cited by 171
Sim, J. Y., Ahn, C.-G., Jeong, E.-J., & Kim, B. K. (2018) · Scientific Reports · doi:10.1038/s41598-018-19340-y · Cited by 161
Noninvasive Diagnostic Devices for Diabetes through Measuring Tear Glucose
Zhang, J., Hodge, W., Hutnick, C., & Wang, X. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500123 · Cited by 147
Non-Invasive Glucose Monitoring: A Review of Challenges and Recent Advances
Lin, T. (2017) · Current Trends in Biomedical Engineering & Biosciences · doi:10.19080/ctbeb.2017.06.555696 · Cited by 142
Glucose-dependent dielectric properties of blood plasma
Topsakal, E., Karacolak, T., & Moreland, E. C. (2011) · URSI General Assembly and Scientific Symposium · doi:10.1109/ursigass.2011.6051324 · Cited by 140
Improved Split-Ring Resonator for Microfluidic Sensing
Rowe, D. J., al-Malki, S., Abduljabar, A. A., Porch, A., Barrow, D. A., & Allender, C. J. (2014) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2014.2299514 · Cited by 127
Continuous Noninvasive Glucose Monitoring Technology Based on “Occlusion Spectroscopy”
Amir, O., Weinstein, D., Zilberman, S., Less, M., Perl-Treves, D., Primack, H., Weinstein, A., Gabis, E., Fikhte, B., & Karasik, A. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100403 · Cited by 123
Turgul, V., & Kale, İ. (2018) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2018.03.041 · Cited by 119
Turgul, V., & Kale, İ. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2757083 · Cited by 111
Harman‐Boehm, I., Gal, A., Raykhman, A. M., Naidis, E., & Mayzel, Y. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400312 · Cited by 98
Burt, M. G., Roberts, G. W., Aguilar-Loza, N. R., & Stranks, S. N. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0282 · Cited by 83
Goodarzi, M., & Saeys, W. (2015) · Talanta · doi:10.1016/j.talanta.2015.08.033 · Cited by 78
Blood Glucose Level Monitoring Using an FMCW Millimeter-Wave Radar Sensor
Omer, A. E., Safavi‐Naeini, S., Hughson, R. L., & Shaker, G. S. A. (2020) · Remote Sensing · doi:10.3390/rs12030385 · Cited by 78
Self-citationKandwal, A., Igbe, T., Li, J., Liu, Y., Li, S., Liu, L. W., & Nie, Z. (2020) · Scientific Reports · doi:10.1038/s41598-020-60806-9 · Cited by 76
WGM-Based Sensing of Characterized Glucose- Aqueous Solutions at mm-Waves
Omer, A. E., Gigoyan, S. S., Shaker, G. S. A., & Safavi‐Naeini, S. (2020) · IEEE Access · doi:10.1109/access.2020.2975805 · Cited by 70
Self-citationPhantoms for Development of Microwave Sensors for Noninvasive Blood Glucose Monitoring
Vrba, J., Karch, J., & Vrba, D. (2015) · International Journal of Antennas and Propagation · doi:10.1155/2015/570870 · Cited by 67
Millimeter-wave non-invasive monitoring of glucose in anesthetized rats
Siegel, P. H., Lee, Y., & Pikov, V. (2014) · International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz) · doi:10.1109/irmmw-thz.2014.6956294 · Cited by 62
Device and method for noninvasive glucose assessment
Segman, Y. (. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818763457 · Cited by 55
Spectroscopic approach for dynamic bioanalyte tracking with minimal concentration information
Spegazzini, N., Barman, I., Dingari, N. C., Pandey, R., Soares, J. S., Ozaki, Y., & Dasari, R. R. (2014) · Scientific Reports · doi:10.1038/srep07013 · Cited by 54
Non-Invasive Monitoring of Glucose Level Changes Utilizing a mm-Wave Radar System
Shaker, G. S. A., Smith, K., Omer, A. E., Liu, S., Csech, C., Wadhwa, U., Safavi‐Naeini, S., & Hughson, R. L. (2018) · International Journal of Mobile Human Computer Interaction · doi:10.4018/ijmhci.2018070102 · Cited by 53
Self-citationYang, J. J., Huang, M., Tang, H. L., Zeng, J. Y., & Dong, L. (2013) · International Journal of Antennas and Propagation · doi:10.1155/2013/637270 · Cited by 53
Kuroda, M., Shinke, T., Otake, H., Sugiyama, D., Takaya, T., Takahashi, H., Terashita, D., Uzu, K., Tahara, N., Kashiwagi, D., et al. (2016) · Cardiovascular Diabetology · doi:10.1186/s12933-016-0395-4 · Cited by 43
Portable Radar-Driven Microwave Sensor for Intermittent Glucose Levels Monitoring
Omer, A. E., Shaker, G. S. A., & Safavi‐Naeini, S. (2020) · IEEE Sensors Letters · doi:10.1109/lsens.2020.2986208 · Cited by 42
Self-citationHadar, E., Chen, R., Toledano, Y., Tenenbaum-Gavish, K., Atzmon, Y., & Hod, M. (2018) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767058.2018.1463987 · Cited by 37
Non-invasive monitoring of diabetes through analysis of the exhaled breath condensate (aerosol)
Karyakin, A. A., Никулина, С. В., Vokhmyanina, D. V., Karyakina, E. E., Anaev, E. K., & Чучалин, А. Г. (2017) · Electrochemistry Communications · doi:10.1016/j.elecom.2017.09.005 · Cited by 36
Vibrotactile and thermal perception and its relation to finger skin thickness
Lundström, R., Dahlqvist, H., Hagberg, M., & Nilsson, T. (2018) · Clinical Neurophysiology Practice · doi:10.1016/j.cnp.2018.01.001 · Cited by 30
Cellular Wireless Energy Harvesting for Smart Contact Lens Applications [Education Corner]
Chen, L., Milligan, B., Qu, T., Jeevananthan, L., Shaker, G. S. A., & Safavi‐Naeini, S. (2018) · IEEE Antennas and Propagation Magazine · doi:10.1109/map.2018.2859200 · Cited by 21
Self-citation
Cited by
Recent Advances in Enzymatic and Non-Enzymatic Electrochemical Glucose Sensing
Hassan, M. H., Vyas, C., Grieve, B., & Bartolo, P. (2021) · Sensors · doi:10.3390/s21144672 · Cited by 364
Omer, A. E., Shaker, G., Safavi-Naeini, S., Alquie, G., Deshours, F., Kokabi, H., & Shubair, R. M. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3038589 · Cited by 185
“The RF/microwave sensing techniques [11]– [29] have shown to be more promising among”
BackgroundSelf-citationMachine Learning‐Reinforced Noninvasive Biosensors for Healthcare
Zhang, K., Wang, J., Liu, T., Luo, Y., Loh, X. J., & Chen, X. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100734 · Cited by 177
Metadata
- Authors
- Omer, A. E., Shaker, G., Safavi-Naeini, S., Kokabi, H., Alquié, G., Deshours, F., & Shubair, R. M.
- Venue
- Scientific Reports
- Published
- 2020-09-16
- Volume
- 10
- Issue
- 1
- Pages
- 15200-15200
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W3087183557
- Cited by
- 283
- References
- 48
- FWCI
- 11.22
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.