The DOI matches its Crossref record; 102 of the 102 references it cites were found in a registry or an index.
Photoplethysmography based atrial fibrillation detection: a review
Open accessAbstract
Atrial fibrillation (AF) is a cardiac rhythm disorder associated with increased morbidity and mortality. It is the leading risk factor for cardioembolic stroke and its early detection is crucial in both primary and secondary stroke prevention. Continuous monitoring of cardiac rhythm is today possible thanks to consumer-grade wearable devices, enabling transformative diagnostic and patient management tools. Such monitoring is possible using low-cost easy-to-implement optical sensors that today equip the majority of wearables. These sensors record blood volume variations—a technology known as photoplethysmography (PPG)—from which the heart rate and other physiological parameters can be extracted to inform about user activity, fitness, sleep, and health. Recently, new wearable devices were introduced as being capable of AF detection, evidenced by large prospective trials in some cases. Such devices would allow for early screening of AF and initiation of therapy to prevent stroke. This review is a summary of a body of work on AF detection using PPG. A thorough account of the signal processing, machine learning, and deep learning approaches used in these studies is presented, followed by a discussion of their limitations and challenges towards clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“atrial fibrillation (AF), which can be identified from pulse wave signals due to the irregular heart rhythm produced by AF”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [27]
In the citing paper
“Several techniques have been proposed to assess the irregularity of IBIs and the shape of pulse waves in order to detect AF from the PPG”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [27]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Rethinking the Inception Architecture for Computer Vision
Szegedy, C., Vanhoucke, V., Ioffe, S., Shlens, J., & Wojna, Z. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.308 · Cited by 32,138
Ror2 signaling regulates Golgi structure and transport through IFT20 for tumor invasiveness
Nishita, M., Park, S.-Y., Nishio, T., Kamizaki, K., Wang, Z., Tamada, K., Takumi, T., Hashimoto, R., Otani, H., Pazour, G. J., et al. (2017) · Scientific Reports · doi:10.1038/s41598-016-0028-x · Cited by 15,947
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Zhang, Q., Wang, C., Zheng, M., Li, Y., Li, J., Zhang, L., Shang, X., & Yan, C. (2014) · Cerebrovascular Diseases · doi:10.1159/000369778 · Cited by 11,609
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P. F., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castellà, M., Diener, H., Heidbüchel, H., Hendriks, J., et al. (2016) · EP Europace · doi:10.1093/europace/euw295 · Cited by 6,438
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
Saito, T., & Rehmsmeier, M. (2015) · PLOS ONE · doi:10.1371/journal.pone.0118432 · Cited by 5,309
Kernan, W. N., Ovbiagele, B., Black, H. R., Bravata, D. M., Chimowitz, M. I., Ezekowitz, M. D., Fang, M. C., Fisher, M., Furie, K. L., Heck, D. V., et al. (2014) · Stroke · doi:10.1161/str.0000000000000024 · Cited by 5,170
The impact of the MIT-BIH Arrhythmia Database
Moody, G. B., & Mark, R. G. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932724 · Cited by 4,834
Worldwide Epidemiology of Atrial Fibrillation: A Global Burden of Disease 2010 Study
Chugh, S. S., Havmoeller, R., Narayanan, K., Singh, D., Rienstra, M., Benjamin, E. J., Gillum, R. F., Kim, Y.-H., McAnulty, J. H., Zheng, Z.-J., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.005119 · Cited by 4,506
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Convolutional Neural Networks for Medical Image Analysis: Full Training or Fine Tuning?
Tajbakhsh, N., Shin, J. Y., Gurudu, S. R., Hurst, R. T., Kendall, C. B., Gotway, M. B., & Liang, J. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2535302 · Cited by 3,277
Hannun, A. Y., Rajpurkar, P., Haghpanahi, M., Tison, G. H., Bourn, C., Turakhia, M. P., & Ng, A. Y. (2019) · Nature Medicine · doi:10.1038/s41591-018-0268-3 · Cited by 3,148
2016 ESC Guidelines for the Management of Atrial Fibrillation Developed in Collaboration With EACTS
Kirchhof, P. F., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castellà, M., Diener, H., Heidbüchel, H., Hendriks, J., et al. (2016) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2016.11.033 · Cited by 1,801
Epidemiology of atrial fibrillation: European perspective
Zoni-Berisso, M., Lercari, F., Carazza, T., & Domenicucci, S. (2014) · Clinical Epidemiology · doi:10.2147/clep.s47385 · Cited by 1,275
Decision tree methods: applications for classification and prediction.
Song, Y. Y., & Lü, Y. (2015) · PubMed · doi:10.11919/j.issn.1002-0829.215044 · Cited by 1,133
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
Trull, T. J., & Ebner-Priemer, U. (2013) · Annual Review of Clinical Psychology · doi:10.1146/annurev-clinpsy-050212-185510 · Cited by 761
The use of photoplethysmography for assessing hypertension
Elgendi, M., Fletcher, R., Liang, Y., Howard, N., Lovell, N. H., Abbott, D., Lim, K., & Ward, R. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0136-7 · Cited by 625
Passive Detection of Atrial Fibrillation Using a Commercially Available Smartwatch
Tison, G. H., Sanchez, J. M., Ballinger, B., Singh, A., Olgin, J. E., Pletcher, M. J., Vittinghoff, E., Lee, E. S., Fan, S. M., Gladstone, R. A., et al. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.0136 · Cited by 566
Independent predictors of stroke in patients with atrial fibrillation
The Stroke Risk in Atrial Fibrillation Working Group (2007) · Neurology · doi:10.1212/01.wnl.0000267275.68538.8d · Cited by 545
Suggestive Annotation: A Deep Active Learning Framework for Biomedical Image Segmentation
Yang, L., Zhang, Y., Chen, J., Zhang, S., & Chen, D. Z. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-66179-7_46 · Cited by 526
Mobile Photoplethysmographic Technology to Detect Atrial Fibrillation
Guo, Y., Wang, H., Zhang, H., Liu, T., Liang, Z., Xia, Y., Yan, L., Xing, Y., Shi, H., Li, S., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.08.019 · Cited by 489
Turakhia, M. P., Desai, M., Hedlin, H., Rajmane, A., Talati, N., Ferris, T., Desai, S., Nag, D., Patel, M., Kowey, P., et al. (2019) · American Heart Journal · doi:10.1016/j.ahj.2018.09.002 · Cited by 474
Part 1: Simple Definition and Calculation of Accuracy, Sensitivity and Specificity.
Baratloo, A., Hosseini, M., Negida, A., & Ashal, G. E. (2015) · Archives of Academic Emergency Medicine · doi:10.22037/aaem.v3i2.264 · Cited by 455
Selecting training sets for support vector machines: a review
Nalepa, J., & Kawulok, M. (2018) · Artificial Intelligence Review · doi:10.1007/s10462-017-9611-1 · Cited by 443
Pulse oximetry: fundamentals and technology update
Nitzan, M., Romem, A., & Koppel, R. (2014) · Medical Devices: Evidence and Research · doi:10.2147/mder.s47319 · Cited by 438
Using Trusted Data to Train Deep Networks on Labels Corrupted by Severe NoisePreprint
Hendrycks, D., Mazeika, M., Wilson, D., & Gimpel, K. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1802.05300 · Cited by 424
Heart-Rate Variability—More than Heart Beats?
Ernst, G. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00240 · Cited by 416
Motion Artifact Reduction in Photoplethysmography Using Independent Component Analysis
Kim, B., & Yoo, S. K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.869784 · Cited by 400
Is There Any Practical Application of Meta-Analytical Results in Strength Training?
Gentil, P., Arruda, A. C. P., Souza, D., Gießing, J., Paoli, A., Fisher, J. P., & Steele, J. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00001 · Cited by 309
Advances in Photopletysmography Signal Analysis for Biomedical Applications
Moraes, J. L., Rocha, M. X., Vasconcelos, G. G., Vasconcelos Filho, J. E., De Albuquerque, V. H. C., & Alexandria, A. R. (2018) · Sensors · doi:10.3390/s18061894 · Cited by 292
Novel Methods for Pulse Wave Velocity Measurement
Pereira, T., Correia, C. M. B. A., & Cardoso, J. M. R. (2015) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-015-0086-8 · Cited by 284
Self-citationA flexible organic reflectance oximeter array
Khan, Y., Han, D., Pierre, A., Ting, J., Wang, X., Lochner, C. M., Bovo, G., Yaacobi-Gross, N., Newsome, C., Wilson, R., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1813053115 · Cited by 278
McManus, D. D., Lee, J., Maitas, O., Esa, N., Pidikiti, R., Carlucci, A., Harrington, J., Mick, E., & Chon, K. H. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2012.12.001 · Cited by 253
Atrial Fibrillation Detection Using an iPhone 4S
Lee, J., Reyes, B. A., McManus, D. D., Maitas, O. L., & Chon, K. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2208112 · Cited by 238
Slocum, J. E., Sahakian, A. V., & Swiryn, S. (1992) · Journal of Electrocardiology · doi:10.1016/0022-0736(92)90123-h · Cited by 191
Flint, A. C., Banki, N. M., Ren, X., Rao, V. A., & Go, A. S. (2012) · Stroke · doi:10.1161/strokeaha.112.665844 · Cited by 187
Photoplethysmography and Deep Learning: Enhancing Hypertension Risk Stratification
Liang, Y., Chen, Z., Ward, R. K., & Elgendi, M. (2018) · Biosensors · doi:10.3390/bios8040101 · Cited by 176
Opening the black box of machine learning
Medicine, T. L. R. (2018) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(18)30425-9 · Cited by 172
A deep learning approach to monitoring and detecting atrial fibrillation using wearable technology
Shashikumar, S. P., Shah, A. J., Qiao, L., Clifford, G. D., & Nemati, S. (2017) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi.2017.7897225 · Cited by 167
Song, W., Tang, L., Xu, Y., Xu, J., Zhang, W., Xie, H., Wang, S., & Guan, X. (2017) · Scientific Reports · doi:10.1038/srep44346 · Cited by 165
PULSE‐SMART: Pulse‐Based Arrhythmia Discrimination Using a Novel Smartphone Application
McMANUS, D. D., CHONG, J. W., SONI, A., SACZYNSKI, J. S., ESA, N., NAPOLITANO, C., DARLING, C. E., BOYER, E., ROSEN, R. K., FLOYD, K. C., et al. (2016) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12842 · Cited by 156
Heart rate variability metrics for fine-grained stress level assessment
Pereira, T., Almeida, P. R., Cunha, J. P. S., & Aguiar, A. (2017) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2017.06.018 · Cited by 153
Self-citationMonitoring and detecting atrial fibrillation using wearable technology
Nemati, S., Ghassemi, M. M., Ambai, V., Isakadze, N., Levantsevych, O. M., Shah, A. J., & Clifford, G. D. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591456 · Cited by 144
Asymptomatic Atrial Fibrillation
Rho, R. W., & Page, R. L. (2005) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2005.06.005 · Cited by 125
Diagnostic assessment of a deep learning system for detecting atrial fibrillation in pulse waveforms
Poh, M., Poh, Y. C., Chan, P., Wong, C., Pun, L., Leung, W. W., Wong, Y., Wong, M. M., Chu, D. W., & Siu, C. (2018) · Heart · doi:10.1136/heartjnl-2018-313147 · Cited by 118
Label-Free Biosensor Detection of Endocrine Disrupting Compounds Using Engineered Estrogen Receptors
Spina, R. L., Ferrero, V. E. V., Aiello, V., Pedotti, M., Varani, L., Lettieri, T., Calzolai, L., Haasnoot, W., & Colpo, P. (2017) · Biosensors · doi:10.3390/bios8010001 · Cited by 115
Kavsaoğlu, A. R., Polat, K., & Hariharan, M. (2015) · Applied Soft Computing · doi:10.1016/j.asoc.2015.04.008 · Cited by 114
Smart detection of atrial fibrillation
Krivoshei, L., Weber, S., Burkard, T., Maseli, A., Brasier, N., Kühne, M., Conen, D., Huebner, T. A., Seeck, A., & Eckstein, J. (2016) · EP Europace · doi:10.1093/europace/euw125 · Cited by 114
Time-Varying Coherence Function for Atrial Fibrillation Detection
Lee, J., Nam, Y., McManus, D. D., & Chon, K. H. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2264721 · Cited by 103
Detection of atrial fibrillation episodes using a wristband device
Corino, V., Laureanti, R., Ferranti, L., Scarpini, G., Lombardi, F., & Mainardi, L. T. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa5dd7 · Cited by 95
Shashikumar, S. P., Shah, A. J., Clifford, G. D., & Nemati, S. (2018) · ACM SIGKDD Conference on Knowledge Discovery and Data Mining (KDD) · doi:10.1145/3219819.3219912 · Cited by 93
Kwon, S., Hong, J., Choi, E., Lee, E., Hostallero, D. E., Kang, W. J., Lee, B., Jeong, E., Koo, B., Oh, S., et al. (2019) · JMIR mhealth and uhealth · doi:10.2196/12770 · Cited by 90
Fan, Y.-Y., Li, Y.-G., Li, J., Cheng, W.-K., Shan, Z.-L., Wang, Y.-T., & Guo, Y.-T. (2019) · JMIR mHealth and uHealth · doi:10.2196/11437 · Cited by 81
A Supervised Approach to Robust Photoplethysmography Quality Assessment
Pereira, T., Gadhoumi, K., Ma, M., Liu, X., Xiao, R., Colorado, R. A., Keenan, K. J., Meisel, K. M., & Hu, X. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2909065 · Cited by 80
Self-citationArrhythmia Discrimination using a Smart Phone
Chong, J. W., Esa, N., McManus, D. D., & Chon, K. H. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2418195 · Cited by 79
Ambulatory Atrial Fibrillation Monitoring Using Wearable Photoplethysmography with Deep Learning
Shen, Y., Voisin, M., Aliamiri, A., Avati, A., Hannun, A., & Ng, A. Y. (2019) · ACM SIGKDD Conference on Knowledge Discovery and Data Mining (KDD) · doi:10.1145/3292500.3330657 · Cited by 70
Identification of Atrial Fibrillation by Quantitative Analyses of Fingertip Photoplethysmogram
Tang, S.-C., Huang, P.-W., Hung, C.-S., Shan, S.-M., Lin, Y.-H., Shieh, J., Lai, D., Wu, A.-Y. (., & Jeng, J. (2017) · Scientific Reports · doi:10.1038/srep45644 · Cited by 64
Eerikäinen, L. M., Bonomi, A. G., Schipper, F., Dekker, L. R. C., Vullings, R., de Morree, H. M., & Aarts, R. M. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aad2c0 · Cited by 61
Atrial Fibrillation Detection Using Photo:plethysmography and Acceleration Data at the Wrist
Bonomi, A., Schipper, F., Eerikäinen, L. M., Margarito, J., Aarts, R. M., Babaeizadeh, S., de Morree, H. M., & Dekker, L. (2016) · Computing in cardiology · doi:10.22489/cinc.2016.081-339 · Cited by 60
Can one detect atrial fibrillation using a wrist-type photoplethysmographic device?
Fallet, S., Lemay, M., Renevey, P., Leupi, C., Pruvot, E. J., & Vésin, J.-M. (2018) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-018-1886-0 · Cited by 58
Deep learning based atrial fibrillation detection using wearable photoplethysmography sensor
Aliamiri, A., & Shen, Y. (2018) · IEEE EMBS International Conference on Biomedical & Health Informatics (BHI) · doi:10.1109/bhi.2018.8333463 · Cited by 54
Isa, N. E. M., Amir, A., Ilyas, M. Z., & Razalli, M. S. (2017) · MATEC Web of Conferences · doi:10.1051/matecconf/201714001024 · Cited by 53
Active cleaning of label noise
Ekambaram, R., Fefilatyev, S., Shreve, M., Kramer, K., Hall, L., Goldgof, D. B., & Kasturi, R. (2015) · Pattern Recognition · doi:10.1016/j.patcog.2015.09.020 · Cited by 50
Detection of atrial fibrillation using an earlobe photoplethysmographic sensor
Conroy, T. B., Guzman, J. H., HALL, B. W., Tsouri, G. R., & Couderc, J. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa8830 · Cited by 48
End-to-end Deep Learning from Raw Sensor Data: Atrial Fibrillation Detection using WearablesPreprint
Gotlibovych, I., Crawford, S. L., Goyal, D., Liu, J., Kerem, Y., Benaron, D. A., Yilmaz, D., Marcus, G. M., & Li, Y. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1807.10707 · Cited by 41
Cicone, A., & Wu, H. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00701 · Cited by 40
Paiva, J. S., Cardoso, J. M. R., & Pereira, T. (2017) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2017.10.011 · Cited by 38
Self-citationBashar, S. K., Han, D., Soni, A., McManus, D. D., & Chon, K. H. (2018) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi.2018.8333374 · Cited by 38
Management of atrial fibrillation in bradyarrhythmias
Boriani, G., & Padeletti, L. (2015) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2015.30 · Cited by 35
Reliable PPG-based algorithm in atrial fibrillation detection
Shan, S.-M., Tang, S., Huang, P.-W., Lin, Y., Huang, W.-H., Lai, D., & Wu, A.-Y. A. (2016) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2016.7833801 · Cited by 35
Dual-tree complex wavelet transform for motion artifact reduction of PPG signals
Raghuram, M., Madhav, K. V., Krishna, E. H., Komalla, N. R., Sivani, K., & Reddy, K. A. (2012) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2012.6226643 · Cited by 34
Pirhonen, M., Peltokangas, M., & Vehkaoja, A. T. (2018) · Sensors · doi:10.3390/s18061693 · Cited by 32
Schäck, T., Harb, Y. S., Muma, M., & Zoubir, A. M. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8036773 · Cited by 30
Monitoring significant ST changes through deep learning
Xiao, R., Xu, Y. X., Pelter, M. M., Fidler, R., Badilini, F., MORTARA, D. W., & Hu, X. (2018) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2018.07.026 · Cited by 30
Self-citationDetection of atrial fibrillation using a smartwatch
Chon, K. H., & McManus, D. D. (2018) · Nature Reviews Cardiology · doi:10.1038/s41569-018-0057-1 · Cited by 29
Christov, I. I., Krasteva, V., Simova, I. I., Neycheva, T., & Schmid, R. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aad9f0 · Cited by 29
Comparison and Noise Suppression of the Transmitted and Reflected Photoplethysmography Signals
Li, S., Liu, L., Wu, J., Tang, B., & Li, D. (2018) · BioMed Research International · doi:10.1155/2018/4523593 · Cited by 29
From genetics to smart watches: developments in precision cardiology
Trayanova, N. A. (2018) · Nature Reviews Cardiology · doi:10.1038/s41569-018-0149-y · Cited by 28
Motion and Noise Artifact-Resilient Atrial Fibrillation Detection Using a Smartphone
Chong, J. W., Cho, C. H., Tabei, F., Le-Anh, D., Esa, N., McManus, D. D., & Chon, K. H. (2018) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2018.2818185 · Cited by 25
Bressan, R. S., Camargo, G. R. P., Bugatti, P. H., & Saito, P. T. M. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2881155 · Cited by 25
PPG-based Heart Rate Estimation with Time-Frequency Spectra
Reiss, A., Schmidt, P., Indlekofer, I., & Laerhoven, K. V. (2018) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/3267305.3274176 · Cited by 24
Tarniceriu, A., Harju, J., Yousefi, Z. R., Vehkaoja, A. T., Parák, J., Yli‐Hankala, A., & Korhonen, I. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513197 · Cited by 24
Wrist:Located Optical Device for Atrial Fibrillation Screening: a Clinical Study on Twenty Patients
Lemay, M., Fallet, S., Renevey, P., Solà, J., Solà, J., Leupi, C., Pruvot, E. J., & Vésin, J.-M. (2016) · Computing in cardiology · doi:10.22489/cinc.2016.200-350 · Cited by 23
An automatic method for arterial pulse waveform recognition using KNN and SVM classifiers
Pereira, T., Paiva, J. S., Correia, C. M. B. A., & Cardoso, J. M. R. (2015) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1393-5 · Cited by 22
Self-citationClinical U pdate on the M anagement of A trial F ibrillation
Danelich, I. M., Reed, B. N., Hollis, I. B., Cook, A. M., & Rodgers, J. E. (2013) · Pharmacotherapy The Journal of Human Pharmacology and Drug Therapy · doi:10.1002/phar.1217 · Cited by 21
Njoum, H., & Kyriacou, P. A. (2013) · Journal of Physics Conference Series · doi:10.1088/1742-6596/450/1/012012 · Cited by 19
Novel Notch Detection Algorithm for Detection of Dicrotic Notch in PPG Signals
Nara, S., Kaur, M., & Verma, K. L. (2014) · International Journal of Computer Applications · doi:10.5120/15081-3520 · Cited by 16
Characterization of Optical System for Hemodynamic Multi-Parameter Assessment
Pereira, T., Santos, I., de Oliveira, T., Vaz, P. G., Correia, T., Pereira, T., Santos, H., Pereira, H., Almeida, V., Cardoso, J., et al. (2013) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-013-0125-y · Cited by 13
Self-citationAmbulatory Atrial Fibrillation Monitoring Using Wearable Photoplethysmography with Deep LearningPreprint
Voisin, M., Shen, Y., Aliamiri, A., Avati, A., Hannun, A., & Ng, A. Y. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1811.07774 · Cited by 13
Pulse pressure waveform estimation using distension profiling with contactless optical probe
Pereira, T., Santos, I. P., Oliveira, T., Vaz, P. G., Pereira, T. S., Santos, H., Pereira, H. C., Correia, C. M. B. A., & Cardoso, J. M. R. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.07.014 · Cited by 11
Self-citationDenoising Time Series Data Using Asymmetric Generative Adversarial Networks
Gandhi, S., Oates, T., Mohsenin, T., & Hairston, D. (2018) · Lecture notes in computer science · doi:10.1007/978-3-319-93040-4_23 · Cited by 11
Decision tree methods: applications for classification and prediction
Yanyan, Song, Ying, Y., & Lü (2015) · 上海精神医学 · Cited by 11
Ensemble empirical mode decomposition applied for PPG motion artifact
Sadrawi, M., Shieh, J.-S., Haraikawa, K., Chien, J. C., Lin, C. H., & Abbod, M. (2016) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes.2016.7843455 · Cited by 9
Optimizing performance of reflectance-based organic Photoplethysmogram (PPG) sensor
Bilgaiyan, A., Sugawara, R., Elsamnah, F., Shim, C.-H., Misran, M. A. B., & Hattori, R. (2018) · Organic and Hybrid Sensors and Bioelectronics · doi:10.1117/12.2321060 · Cited by 8
Shashikumar, S. P., Shah, A. J., Clifford, G. D., et al. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1805.09133 · Cited by 7
Gadhoumi, K., Keenan, K. J., Pereira, T., Colorado, R. A., Meisel, K. M., & Hu, X. (2018) · Computing in cardiology · doi:10.22489/cinc.2018.316 · Cited by 6
Self-citationGuo, Y., Liu, T., Chen, Y., & Lip, G. Y. H. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.01.021 · Cited by 4
Stroke prevention in atrial fibrillation: can we do better?
Lane, D. A., & Lip, G. Y. H. (2016) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2016.117 · Cited by 3
Research works printed but not linked: 5
- Singh, D. et al. Worldwide epidemiology of atrial fibrillation. Circulation 129, 837–847 (2013).
- Tripathi, S., San, U. C., Zachary, D., Lipton, C. & Nguyen, T. Q. Correction by projection: denoising images with generative adversarial networks. Preprint at http://arXiv.org/1803.04477v1 (2018).
- Rolnick, D., Veit, A., Belongie, S. & Shavit, N. Deep learning is robust to massive label noise. Preprint at http://arXiv.org/1705.10694 [cs.LG] (2017).
- Xu, M., Qian, F. & Pushp, S. Enabling cooperative inference of deep learning on wearables and smartphones. Preprint at http://arXiv.org/1712.03073, 1–21 (2017).
- Schack, T., Harb, Y. S., Muma, M. & Zoubir, A. M. Computationally Efficient Algorithm for Photoplethysmography-Based Atrial Fibrillation Detection Using Smartphones. In 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 104–108 (2017). · DOI
Cited by
Sorted by citations
Brundel, B. J. J. M., Ai, X., Hills, M. T., Kuipers, M. F., Lip, G. Y. H., & de Groot, N. M. S. (2022) · Nature Reviews Disease Primers · doi:10.1038/s41572-022-00347-9 · Cited by 545
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 514
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250
Krittanawong, C., Rogers, A. J., Johnson, K. W., Wang, Z., Turakhia, M. P., Halperin, J. L., & Narayan, S. M. (2020) · Nature Reviews Cardiology · doi:10.1038/s41569-020-00445-9 · Cited by 248
The 2023 wearable photoplethysmography roadmap
Charlton, P. H., Allen, J., Bailón, R., Baker, S., Behar, J. A., Chen, F., Clifford, G. D., Clifton, D. A., Davies, H. J., Ding, C., et al. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acead2 · Cited by 233
Self-citation
Metadata
- Authors
- Pereira, T., Tran, N., Gadhoumi, K., Pelter, M. M., Do, D. H., Lee, R. J., Colorado, R., Meisel, K., & Hu, X.
- Affiliations
- University of California, San Francisco (US)
- University of California, Los Angeles (US)
- Venue
- npj Digital Medicine
- Published
- 2020-01-10
- Volume
- 3
- Issue
- 1
- Pages
- 3-3
- ISSN
- 2398-6352 (ISSN-L)
- PMC
- PMC6954115
- OpenAlex
- W2999926771
- Cited by
- 300
- References
- 102
- Citations by year
- 2026: 34 · 2025: 47 · 2024: 57 · 2023: 51 · 2022: 40 · 2021: 50 · 2020: 18
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- npj Digital Medicine (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- eScholarship (California Digital Library) (submittedVersion, cc-by)
- Funders
- National Institutes of Health (R01NHLBI128679)
- National Heart, Lung, and Blood Institute (R01NHLBI128679, R01HL128679)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- atrial fibrillation detection, photoplethysmography, wearable devices, optical sensors, cardioembolic stroke prevention, signal processing, machine learning, deep learning, early screening
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review