CoChat

Wearable radio-frequency sensing of respiratory rate, respiratory volume, and heart rate

Sharma, Pragya, Hui, Xiaonan, Zhou, Jianlin, Conroy, Thomas B., Kan, Edwin C. · 2020 · npj Digital Medicine
Cited by 117

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Many health diagnostic systems demand noninvasive sensing of respiratory rate, respiratory volume, and heart rate with high user comfort. Previous methods often require multiple sensors, including skin-touch electrodes, tension belts, or nearby off-the-body readers, and hence are uncomfortable or inconvenient. This paper presents an over-clothing wearable radio-frequency sensor study, conducted on 20 healthy participants (14 females) performing voluntary breathing exercises in various postures. Two prototype sensors were placed on the participants, one close to the heart and the other below the xiphoid process to couple to the motion from heart, lungs and diaphragm, by the near-field coherent sensing principle. We can achieve a satisfactory correlation of our sensor with the reference devices for the three vital signs: heart rate ( r = 0.95), respiratory rate ( r = 0.93) and respiratory volume ( r = 0.84). We also detected voluntary breath-hold periods with an accuracy of 96%. Further, the participants performed a breathing exercise by contracting abdomen inwards while holding breath, leading to paradoxical outward thorax motion under the isovolumetric condition, which was detected with an accuracy of 83%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41746-020-0307-6

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Research works printed but not linked: 41

  1. Sanchis-Gomar, F. et al. Physical inactivity and low fitness deserve more attention to alter cancer risk and prognosis. Cancer Prev. Res. 8, 105–110 (2015). · DOI
  2. Mitchell, G. Rapidly increasing end-of-life care needs: a timely warning. BMC Med. 15, 126 (2017). · doi:10.1186/s12916-017-0897-2
  3. Rubio, N. et al. Home monitoring of breathing rate in people with chronic obstructive pulmonary disease: observational study of feasibility, acceptability, and change after exacerbation. Int. J. Chron. Obstruct. Pulmon. Dis. 12, 1221–1231 (2017). · DOI
  4. DePaso, W. J., Winterbauer, R. H., Lusk, J. A., Dreis, D. P. & Springmeyer, S. C. Chronic dyspnea unexplained by history, physical examination, chest roentgenogram, and spirometry: analysis of a seven-year experience. Chest 100, 1293–1299 (1991). · DOI
  5. Farré, R., Montserrat, J. M. & Navajas, D. Noninvasive monitoring of respiratory mechanics during sleep. Eur. Respir. J. 24, 1052–1060 (2004). · DOI · Paper page
  6. Massaroni, C. et al. Contact-based methods for measuring respiratory rate. Sensors 19, 908 (2019). · DOI · Paper page
  7. Rofail, L. M., Wong, K. K. H., Unger, G., Marks, G. B. & Grunstein, R. R. Comparison between a single-channel nasal airflow device and oximetry for the diagnosis of obstructive sleep apnea. Sleep 33, 1106–1114 (2010). · DOI · Paper page
  8. Brüllmann, G., Thurnheer, R. & Bloch, E. Respiratory monitoring by inductive plethysmography in unrestrained subjects using position sensor-adjusted calibration. Respiration 79, 112–120 (2010). · DOI
  9. Chu, M. et al. Respiration rate and volume measurements using wearable strain sensors. NPJ Digit. Med. 2, 8 (2019). · DOI · Paper page
  10. Tremper, K. K. Pulse oximetry. Chest 95, 713–715 (1989). · DOI
  11. Biswas, D., Simoes-Capela, N., Van Hoof, C. & Van Helleputte, N. Heart rate estimation from wrist-worn photoplethysmography: a review. IEEE Sens. J. 19, 6560–6570 (2019). · DOI · Paper page
  12. Zheng, Y. et al. Unobtrusive sensing and wearable devices for health informatics. IEEE Trans. Biomed. Eng. 61, 1538–1554 (2014). · DOI · Paper page
  13. Taebi, A., Solar, B., Bomar, A., Sandler, R. & Mansy, H. Recent advances in seismocardiography. Vibration 2, 64–86 (2019). · DOI · Paper page
  14. Xia, Z., Member, S., Shandhi, M. H. & Member, S. Non-contact sensing of seismocardiogram. IEEE Sens. J. 18, 5956–5964 (2018). · DOI
  15. Pinheiro, E., Postolache, O. & Girão, P. Theory and developments in an unobtrusive cardiovascular system representation: Ballistocardiography. Open Biomed. Eng. J. 4, 201–216 (2010). · DOI · Paper page
  16. Sadek, I., Seet, E., Biswas, J., Abdulrazak, B. & Mokhtari, M. Nonintrusive vital signs monitoring for sleep apnea patients: a preliminary study. IEEE Access 6, 2506–2514 (2018). · DOI
  17. Pinheiro, E., Postolache, O. & Girão, P. Study on ballistocardiogram acquisition in a moving wheelchair with embedded sensors. Metrol. Meas. Syst. 19, 739–750 (2012). · DOI
  18. Bansal, C., Scott, R., Stewart, D. & Cockerell, C. J. Decubitus ulcers: a review of the literature. Int. J. Dermatol. 44, 805–810 (2005). · DOI · Paper page
  19. Zeevi, T., Levy, A., Brauner, N. & Gefen, A. Effects of ambient conditions on the risk of pressure injuries in bedridden patients—multi-physics modelling of microclimate. Int. Wound J. 15, 402–416 (2018). · doi:10.1111/iwj.12877
  20. Reyes, B. A. et al. Tidal volume and instantaneous respiration rate estimation using a volumetric surrogate signal acquired via a smartphone camera. IEEE J. Biomed. Heal. Inform. 21, 764–777 (2017). · DOI
  21. Li, C., Lubecke, V. M., Boric-Lubecke, O. & Lin, J. A review on recent advances in Doppler radar sensors for noncontact healthcare monitoring. IEEE Trans. Microw. Theory Tech. 61, 2046–2060 (2013). · DOI · Paper page
  22. Naishadham, K. et al. Estimation of cardiopulmonary parameters from ultra wideband radar measurements using the state space method. IEEE Trans. Biomed. Circuits Syst. 10, 1037–1046 (2016). · DOI
  23. Zito, D. et al. SoC CMOS UWB pulse radar sensor for contactless respiratory rate monitoring. IEEE Trans. Biomed. Circuits Syst. 5, 503–510 (2011). · DOI · Paper page
  24. Nguyen, P., Zhang, X., Halbower, A. & Vu, T. Continuous and fine-grained breathing volume monitoring from afar using wireless signals. In IEEE INFOCOM 2016 - The 35th Annual IEEE International Conference on Computer Communications, pp. 1–9 (IEEE, San Francisco, CA, 2016). https://doi.org/10.1109/INFOCOM.2016.7524402. · DOI
  25. Massagram, W., Hafner, N., Lubecke, V. & Boric-Lubecke, O. Tidal volume measurement through non-contact Doppler radar with DC reconstruction. IEEE Sens. J. 13, 3397–3404 (2013). · DOI
  26. Pfanner, F., Allmendinger, T., Flohr, T. & Kachelrieß, M. Modelling and simulation of a respiratory motion monitor using a continuous wave Doppler radar in near field. Proc. SPIE Med. Imag. 8668, 1–12 (2013).
  27. Teichmann, D., Kuhn, A., Leonhardt, S. & Walter, M. The main shirt: a textile-integrated magnetic induction sensor array. Sensors 14, 1039–1056 (2014). · DOI
  28. Hui, X. & Kan, E. C. Monitoring vital signs over multiplexed radio by near-field coherent sensing. Nat. Electron. 1, 74–78 (2018). · DOI
  29. Hui, X., Sharma, P. & Kan, E. C. Microwave stethoscope for heart sound by near-field coherent sensing. In EEE MTT-S International Microwave Symposium (IMS), pp. 365–368 (IEEE, Boston, MA, USA, 2019). https://doi.org/10.1109/MWSYM.2019.8700904. · DOI
  30. Li, C., Cummings, J., Lam, J., Graves, E. & Wu, W. Radar remote monitoring of vital signs. IEEE Microw. Mag. 10, 47–56 (2009). · DOI · Paper page
  31. Sharma, P., Hui, X. & Kan, E. C. A wearable RF sensor for monitoring respiratory patterns. In 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), pp. 1217–1223 (IEEE, Berlin, Germany, 2019). https://doi.org/10.1109/EMBC.2019.8857870. · DOI
  32. Muza, R. T. Central sleep apnoea-a clinical review. J. Thorac. Dis. 7, 930–937 (2015).
  33. Konno, K. & Mead, J. Measurement of the separate volume changes of rib cage and abdomen during breathing. J. Appl. Physiol. 22, 407–422 (1967). · DOI · Paper page
  34. Ambrosino, N. & Scano, G. Dyspnoea and its measurement. Rev. Lit. Arts Am. 1, 100–107 (2004).
  35. Campbell, M. L., Templin, T. & Walch, J. A respiratory distress observation scale for patients unable to self-report dyspnea. J. Palliat. Med. 13, 285–290 (2010). · DOI · Paper page
  36. Gordon, P. H., Chen, R., Park, H. & Kan, E. C. Embroidered antenna characterization for passive UHF RFID tags. In IEEE RFID Conf., https://arxiv.org/abs/1710.02237 (2016). · arXiv
  37. Stoet, G. PsyToolkit: a software package for programming psychological experiments using Linux. Behav. Res. Methods 42, 1096–1104 (2010). · DOI · Paper page
  38. Stoet, G. PsyToolkit: a novel web-based method for running online questionnaires and reaction-time experiments. Teach. Psychol. 44, 24–31 (2017). · DOI · Paper page
  39. Lu, W. et al. A semi-automatic method for peak and valley detection in free-breathing respiratory waveforms. Med. Phys. 33, 3634–3636 (2006). · doi:10.1118/1.2348764
  40. Sharma, P. & Kan, E. C. Sleep scoring with a UHF RFID tag by near field coherent sensing. In IEEE/MTT-S International Microwave Symposium - IMS, pp. 1419–1422 (IEEE, Philadelphia, PA, 2018). https://doi.org/10.1109/MWSYM.2018.8439216. · DOI
  41. Scholkopf, B., Williamson, R., Smola, A., Shawe-Taylor, J. & Platt, J. Support vector method for novelty detection. In Proceedings of the 12th International Conference on Neural Information Processing Systems (NIPS’99). pp. 582–588 (MIT Press, Cambridge, MA, USA, 1999).

Cited by

Metadata

Authors
Sharma, P., Hui, X., Zhou, J., Conroy, T. B., & Kan, E. C.
Venue
npj Digital Medicine
Published
2020-07-28
Volume
3
Issue
1
ISSN
2398-6352
Cited by
117
References
8
Language
en
Licence
Funders
  • United States Department of Defense | United States Army | Army Medical Command | Congressionally Directed Medical Research Programs (PR-182496)
  • DOE | Advanced Research Projects Agency - Energy (DE-AR0000946)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.