Wearable radio-frequency sensing of respiratory rate, respiratory volume, and heart rate
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Many health diagnostic systems demand noninvasive sensing of respiratory rate, respiratory volume, and heart rate with high user comfort. Previous methods often require multiple sensors, including skin-touch electrodes, tension belts, or nearby off-the-body readers, and hence are uncomfortable or inconvenient. This paper presents an over-clothing wearable radio-frequency sensor study, conducted on 20 healthy participants (14 females) performing voluntary breathing exercises in various postures. Two prototype sensors were placed on the participants, one close to the heart and the other below the xiphoid process to couple to the motion from heart, lungs and diaphragm, by the near-field coherent sensing principle. We can achieve a satisfactory correlation of our sensor with the reference devices for the three vital signs: heart rate ( r = 0.95), respiratory rate ( r = 0.93) and respiratory volume ( r = 0.84). We also detected voluntary breath-hold periods with an accuracy of 96%. Further, the participants performed a breathing exercise by contracting abdomen inwards while holding breath, leading to paradoxical outward thorax motion under the isovolumetric condition, which was detected with an accuracy of 83%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Additional applications include the monitoring of sweat production, skin hydration levels, electrolyte concentrations and respiratory rates128,129.”
From End-to-end design of wearable sensors (2022) · cites this paper as [128]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultrastructural Characterization of the Lower Motor System in a Mouse Model of Krabbe Disease
Cappello, V., Marchetti, L., Parlanti, P., Landi, S., Tonazzini, I., Cecchini, M., Piazza, V., & Gemmi, M. (2016) · Scientific Reports · doi:10.1038/s41598-016-0001-8 · Cited by 13,097
Graham, B. L., Steenbruggen, I., Miller, M. R., Barjaktarevic, I. Z., Cooper, B. G., Hall, G. L., Hallstrand, T. S., Kaminsky, D. A., McCarthy, K., McCormack, M. C., et al. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201908-1590st · Cited by 4,305
Standardisation of the measurement of lung volumes
Wanger, J., Clausen, J. L., Coates, A., Pedersen, O. F., Brusasco, V., Burgos, F., Casaburi, R., Crapo, R., Enright, P., van der Grinten, C. P. M., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00035005 · Cited by 2,768
Detering, K. M., Hancock, A. D., Reade, M. C., & Silvester, W. (2010) · BMJ · doi:10.1136/bmj.c1345 · Cited by 2,332
Smart Homes that Monitor Breathing and Heart Rate
Adib, F., Mao, H., Kabelac, Z., Katabi, D., & Miller, R. C. (2015) · Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems · doi:10.1145/2702123.2702200 · Cited by 916
Ballistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775
Signal-to-Noise Ratio in Doppler Radar System for Heart and Respiratory Rate Measurements
Droitcour, A. D., Boric-Lubecke, O., & Kovacs, G. T. A. (2009) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2009.2029668 · Cited by 162
Healthy lifestyle habits and mortality in overweight and obese individuals
Matheson, E. M., King, D. E., & Everett, C. J. (2012) · The Journal of the American Board of Family Medicine · doi:10.3122/jabfm.2012.01.110164 · Cited by 150
Research works printed but not linked: 41
- Sanchis-Gomar, F. et al. Physical inactivity and low fitness deserve more attention to alter cancer risk and prognosis. Cancer Prev. Res. 8, 105–110 (2015). · DOI
- Mitchell, G. Rapidly increasing end-of-life care needs: a timely warning. BMC Med. 15, 126 (2017). · doi:10.1186/s12916-017-0897-2
- Rubio, N. et al. Home monitoring of breathing rate in people with chronic obstructive pulmonary disease: observational study of feasibility, acceptability, and change after exacerbation. Int. J. Chron. Obstruct. Pulmon. Dis. 12, 1221–1231 (2017). · DOI
- DePaso, W. J., Winterbauer, R. H., Lusk, J. A., Dreis, D. P. & Springmeyer, S. C. Chronic dyspnea unexplained by history, physical examination, chest roentgenogram, and spirometry: analysis of a seven-year experience. Chest 100, 1293–1299 (1991). · DOI
- Farré, R., Montserrat, J. M. & Navajas, D. Noninvasive monitoring of respiratory mechanics during sleep. Eur. Respir. J. 24, 1052–1060 (2004). · DOI · Paper page
- Massaroni, C. et al. Contact-based methods for measuring respiratory rate. Sensors 19, 908 (2019). · DOI · Paper page
- Rofail, L. M., Wong, K. K. H., Unger, G., Marks, G. B. & Grunstein, R. R. Comparison between a single-channel nasal airflow device and oximetry for the diagnosis of obstructive sleep apnea. Sleep 33, 1106–1114 (2010). · DOI · Paper page
- Brüllmann, G., Thurnheer, R. & Bloch, E. Respiratory monitoring by inductive plethysmography in unrestrained subjects using position sensor-adjusted calibration. Respiration 79, 112–120 (2010). · DOI
- Chu, M. et al. Respiration rate and volume measurements using wearable strain sensors. NPJ Digit. Med. 2, 8 (2019). · DOI · Paper page
- Tremper, K. K. Pulse oximetry. Chest 95, 713–715 (1989). · DOI
- Biswas, D., Simoes-Capela, N., Van Hoof, C. & Van Helleputte, N. Heart rate estimation from wrist-worn photoplethysmography: a review. IEEE Sens. J. 19, 6560–6570 (2019). · DOI · Paper page
- Zheng, Y. et al. Unobtrusive sensing and wearable devices for health informatics. IEEE Trans. Biomed. Eng. 61, 1538–1554 (2014). · DOI · Paper page
- Taebi, A., Solar, B., Bomar, A., Sandler, R. & Mansy, H. Recent advances in seismocardiography. Vibration 2, 64–86 (2019). · DOI · Paper page
- Xia, Z., Member, S., Shandhi, M. H. & Member, S. Non-contact sensing of seismocardiogram. IEEE Sens. J. 18, 5956–5964 (2018). · DOI
- Pinheiro, E., Postolache, O. & Girão, P. Theory and developments in an unobtrusive cardiovascular system representation: Ballistocardiography. Open Biomed. Eng. J. 4, 201–216 (2010). · DOI · Paper page
- Sadek, I., Seet, E., Biswas, J., Abdulrazak, B. & Mokhtari, M. Nonintrusive vital signs monitoring for sleep apnea patients: a preliminary study. IEEE Access 6, 2506–2514 (2018). · DOI
- Pinheiro, E., Postolache, O. & Girão, P. Study on ballistocardiogram acquisition in a moving wheelchair with embedded sensors. Metrol. Meas. Syst. 19, 739–750 (2012). · DOI
- Bansal, C., Scott, R., Stewart, D. & Cockerell, C. J. Decubitus ulcers: a review of the literature. Int. J. Dermatol. 44, 805–810 (2005). · DOI · Paper page
- Zeevi, T., Levy, A., Brauner, N. & Gefen, A. Effects of ambient conditions on the risk of pressure injuries in bedridden patients—multi-physics modelling of microclimate. Int. Wound J. 15, 402–416 (2018). · doi:10.1111/iwj.12877
- Reyes, B. A. et al. Tidal volume and instantaneous respiration rate estimation using a volumetric surrogate signal acquired via a smartphone camera. IEEE J. Biomed. Heal. Inform. 21, 764–777 (2017). · DOI
- Li, C., Lubecke, V. M., Boric-Lubecke, O. & Lin, J. A review on recent advances in Doppler radar sensors for noncontact healthcare monitoring. IEEE Trans. Microw. Theory Tech. 61, 2046–2060 (2013). · DOI · Paper page
- Naishadham, K. et al. Estimation of cardiopulmonary parameters from ultra wideband radar measurements using the state space method. IEEE Trans. Biomed. Circuits Syst. 10, 1037–1046 (2016). · DOI
- Zito, D. et al. SoC CMOS UWB pulse radar sensor for contactless respiratory rate monitoring. IEEE Trans. Biomed. Circuits Syst. 5, 503–510 (2011). · DOI · Paper page
- Nguyen, P., Zhang, X., Halbower, A. & Vu, T. Continuous and fine-grained breathing volume monitoring from afar using wireless signals. In IEEE INFOCOM 2016 - The 35th Annual IEEE International Conference on Computer Communications, pp. 1–9 (IEEE, San Francisco, CA, 2016). https://doi.org/10.1109/INFOCOM.2016.7524402. · DOI
- Massagram, W., Hafner, N., Lubecke, V. & Boric-Lubecke, O. Tidal volume measurement through non-contact Doppler radar with DC reconstruction. IEEE Sens. J. 13, 3397–3404 (2013). · DOI
- Pfanner, F., Allmendinger, T., Flohr, T. & Kachelrieß, M. Modelling and simulation of a respiratory motion monitor using a continuous wave Doppler radar in near field. Proc. SPIE Med. Imag. 8668, 1–12 (2013).
- Teichmann, D., Kuhn, A., Leonhardt, S. & Walter, M. The main shirt: a textile-integrated magnetic induction sensor array. Sensors 14, 1039–1056 (2014). · DOI
- Hui, X. & Kan, E. C. Monitoring vital signs over multiplexed radio by near-field coherent sensing. Nat. Electron. 1, 74–78 (2018). · DOI
- Hui, X., Sharma, P. & Kan, E. C. Microwave stethoscope for heart sound by near-field coherent sensing. In EEE MTT-S International Microwave Symposium (IMS), pp. 365–368 (IEEE, Boston, MA, USA, 2019). https://doi.org/10.1109/MWSYM.2019.8700904. · DOI
- Li, C., Cummings, J., Lam, J., Graves, E. & Wu, W. Radar remote monitoring of vital signs. IEEE Microw. Mag. 10, 47–56 (2009). · DOI · Paper page
- Sharma, P., Hui, X. & Kan, E. C. A wearable RF sensor for monitoring respiratory patterns. In 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), pp. 1217–1223 (IEEE, Berlin, Germany, 2019). https://doi.org/10.1109/EMBC.2019.8857870. · DOI
- Muza, R. T. Central sleep apnoea-a clinical review. J. Thorac. Dis. 7, 930–937 (2015).
- Konno, K. & Mead, J. Measurement of the separate volume changes of rib cage and abdomen during breathing. J. Appl. Physiol. 22, 407–422 (1967). · DOI · Paper page
- Ambrosino, N. & Scano, G. Dyspnoea and its measurement. Rev. Lit. Arts Am. 1, 100–107 (2004).
- Campbell, M. L., Templin, T. & Walch, J. A respiratory distress observation scale for patients unable to self-report dyspnea. J. Palliat. Med. 13, 285–290 (2010). · DOI · Paper page
- Gordon, P. H., Chen, R., Park, H. & Kan, E. C. Embroidered antenna characterization for passive UHF RFID tags. In IEEE RFID Conf., https://arxiv.org/abs/1710.02237 (2016). · arXiv
- Stoet, G. PsyToolkit: a software package for programming psychological experiments using Linux. Behav. Res. Methods 42, 1096–1104 (2010). · DOI · Paper page
- Stoet, G. PsyToolkit: a novel web-based method for running online questionnaires and reaction-time experiments. Teach. Psychol. 44, 24–31 (2017). · DOI · Paper page
- Lu, W. et al. A semi-automatic method for peak and valley detection in free-breathing respiratory waveforms. Med. Phys. 33, 3634–3636 (2006). · doi:10.1118/1.2348764
- Sharma, P. & Kan, E. C. Sleep scoring with a UHF RFID tag by near field coherent sensing. In IEEE/MTT-S International Microwave Symposium - IMS, pp. 1419–1422 (IEEE, Philadelphia, PA, 2018). https://doi.org/10.1109/MWSYM.2018.8439216. · DOI
- Scholkopf, B., Williamson, R., Smola, A., Shawe-Taylor, J. & Platt, J. Support vector method for novelty detection. In Proceedings of the 12th International Conference on Neural Information Processing Systems (NIPS’99). pp. 582–588 (MIT Press, Cambridge, MA, USA, 1999).
Cited by
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
Smart Bandage With Wireless Strain and Temperature Sensors and Batteryless NFC Tag
Escobedo, P., Bhattacharjee, M., Nikbakhtnasrabadi, F., & Dahiya, R. (2021) · IEEE Internet of Things Journal · doi:10.1109/jiot.2020.3048282 · Cited by 209
“This tag can be used in different healthcare applications for wirelessly monitoring of wound status or respiratory diseases, such as asthma and COVID-19, where monitoring via wearable strain (e.g., respiratory volume) and temperature sensors is critical.”
Background
Metadata
- Authors
- Sharma, P., Hui, X., Zhou, J., Conroy, T. B., & Kan, E. C.
- Venue
- npj Digital Medicine
- Published
- 2020-07-28
- Volume
- 3
- Issue
- 1
- ISSN
- 2398-6352
- Semantic Scholar
- 739154b8c268a25361994dcc6cc28dc6845f0a5b
- Cited by
- 117
- References
- 8
- Language
- en
- Licence
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Funders
- United States Department of Defense | United States Army | Army Medical Command | Congressionally Directed Medical Research Programs (PR-182496)
- DOE | Advanced Research Projects Agency - Energy (DE-AR0000946)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.