The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Detecting bacteria and determining their susceptibility to antibiotics by stochastic confinement in nanoliter droplets using plug-based microfluidics
Open accessAbstract
This article describes plug-based microfluidic technology that enables rapid detection and drug susceptibility screening of bacteria in samples, including complex biological matrices, without pre-incubation. Unlike conventional bacterial culture and detection methods, which rely on incubation of a sample to increase the concentration of bacteria to detectable levels, this method confines individual bacteria into droplets nanoliters in volume. When single cells are confined into plugs of small volume such that the loading is less than one bacterium per plug, the detection time is proportional to plug volume. Confinement increases cell density and allows released molecules to accumulate around the cell, eliminating the pre-incubation step and reducing the time required to detect the bacteria. We refer to this approach as 'stochastic confinement'. Using the microfluidic hybrid method, this technology was used to determine the antibiogram - or chart of antibiotic sensitivity - of methicillin-resistant Staphylococcus aureus (MRSA) to many antibiotics in a single experiment and to measure the minimal inhibitory concentration (MIC) of the drug cefoxitin (CFX) against this strain. In addition, this technology was used to distinguish between sensitive and resistant strains of S. aureus in samples of human blood plasma. High-throughput microfluidic techniques combined with single-cell measurements also enable multiple tests to be performed simultaneously on a single sample containing bacteria. This technology may provide a method of rapid and effective patient-specific treatment of bacterial infections and could be extended to a variety of applications that require multiple functional tests of bacterial samples on reduced timescales.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The epidemiology of sepsis in the United States from 1979 through 2000
Martin, G. S., Mannino, D. M., Eaton, S., & Moss, M. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022139 · Cited by 5,841
Methicillin-Resistant S. aureus Infections among Patients in the Emergency Department
Moran, G. J., Krishnadasan, A., Gorwitz, R. J., Fosheim, G. E., McDougal, L. K., Carey, R. B., & Talan, D. A. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa055356 · Cited by 2,285
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Self-citationA Microfluidic System for Controlling Reaction Networks in Time
Song, H., Tice, J. D., & Ismagilov, R. F. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390203 · Cited by 1,082
Self-citationFranzblau, S. G., Witzig, R. S., McLaughlin, J. C., Torres, P., Madico, G., Hernandez, A., Degnan, M. T., Cook, M. B., Quenzer, V. K., Ferguson, R. M., et al. (1998) · Journal of Clinical Microbiology · doi:10.1128/jcm.36.2.362-366.1998 · Cited by 964
Identification of methicillin-resistant strains of staphylococci by polymerase chain reaction
Murakami, K., Minamide, W., Wada, K., Nakamura, E., Teraoka, H., & Watanabe, S. (1991) · Journal of Clinical Microbiology · doi:10.1128/jcm.29.10.2240-2244.1991 · Cited by 942
Probing Gene Expression in Live Cells, One Protein Molecule at a Time
Yu, J., Xiao, J., Ren, X., Lao, K., & Xie, X. S. (2006) · Science · doi:10.1126/science.1119623 · Cited by 918
Microfabrication meets microbiology
Weibel, D. B., DiLuzio, W. R., & Whitesides, G. M. (2007) · Nature Reviews Microbiology · doi:10.1038/nrmicro1616 · Cited by 788
He, M., Edgar, J. S., Jeffries, G. D. M., Lorenz, R. M., Shelby, J. P., & Chiu, D. T. (2005) · Analytical Chemistry · doi:10.1021/ac0480850 · Cited by 518
Update on detection of bacteremia and fungemia
Reimer, L. G., Wilson, M. L., & Weinstein, M. P. (1997) · Clinical Microbiology Reviews · doi:10.1128/cmr.10.3.444 · Cited by 482
Cited by
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Droplet microfluidic technology for single-cell high-throughput screening
Brouzes, E., Medkova, M., Savenelli, N., Marran, D., Twardowski, M., Hutchison, J. B., Rothberg, J. M., Link, D. R., Perrimon, N., & Samuels, M. L. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0903542106 · Cited by 1,069
Microdroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology
Theberge, A. B., Courtois, F., Schaerli, Y., Fischlechner, M., Abell, C., Hollfelder, F., & Huck, W. T. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906653 · Cited by 1,059
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Surfactants in droplet-based microfluidics
Baret, J.-C. (2012) · Lab Chip · doi:10.1039/c1lc20582j · Cited by 649
Droplet Microfluidics—A Tool for Single‐Cell Analysis
Joensson, H. N., & Andersson Svahn, H. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200460 · Cited by 557
Droplet microfluidics for microbiology: techniques, applications and challenges
Kaminski, T. S., Scheler, O., & Garstecki, P. (2016) · Lab on a Chip · doi:10.1039/c6lc00367b · Cited by 424
Du, W., Li, L., Nichols, K. P., & Ismagilov, R. F. (2009) · Lab on a Chip · doi:10.1039/b908978k · Cited by 351
Self-citationModern Tools for Rapid Diagnostics of Antimicrobial Resistance
Vasala, A., Hytönen, V. P., & Laitinen, O. H. (2020) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2020.00308 · Cited by 349
Boedicker, J. Q., Vincent, M. E., & Ismagilov, R. F. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200901550 · Cited by 327
Self-citationNew and developing diagnostic technologies for urinary tract infections
Davenport, M., Mach, K. E., Shortliffe, L. M. D., Banaei, N., Wang, T.-H., & Liao, J. C. (2017) · Nature Reviews Urology · doi:10.1038/nrurol.2017.20 · Cited by 321
A rapid antimicrobial susceptibility test based on single-cell morphological analysis
Choi, J., Yoo, J., Lee, M., Kim, E.-G., Lee, J. S., Lee, S., Joo, S., Song, S. H., Kim, E.-C., Lee, J. C., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3009650 · Cited by 311
3D printing of microscopic bacterial communities
Connell, J. L., Ritschdorff, E. T., Whiteley, M., & Shear, J. B. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1309729110 · Cited by 305
Advances in microfluidic PCR for point-of-care infectious disease diagnostics
Park, S., Zhang, Y., Lin, S., Wang, T.-H., & Yang, S. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.017 · Cited by 299
Kang, D.-K., Ali, M. M., Zhang, K., Huang, S. S., Peterson, E., Digman, M. A., Gratton, E., & Zhao, W. (2014) · Nature Communications · doi:10.1038/ncomms6427 · Cited by 297
Microfluidics for cell-based high throughput screening platforms—A review
Du, G., Fang, Q., & den Toonder, J. M. J. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.11.023 · Cited by 276
Massively parallel screening of synthetic microbial communities
Kehe, J., Kulesa, A., Ortiz, A., Ackerman, C. M., Thakku, S. G., Sellers, D., Kuehn, S., Gore, J., Friedman, J., & Blainey, P. C. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1900102116 · Cited by 263
Kreutz, J. E., Munson, T., Huynh, T., Shen, F., Du, W., & Ismagilov, R. F. (2011) · Analytical Chemistry · doi:10.1021/ac201658s · Cited by 148
Self-citationThe revolution of PDMS microfluidics in cellular biology
Banik, S., Uchil, A., Kalsang, T., Chakrabarty, S., Ali, M. A., Srisungsitthisunti, P., Mahato, K. K., Surdo, S., & Mazumder, N. (2023) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2022.2034733 · Cited by 84
New Technologies for Studying Biofilms
Franklin, M. J., Chang, C., Akiyama, T., & Bothner, B. (2015) · Microbial Biofilms · doi:10.1128/9781555817466.ch1 · Cited by 11
Metadata
- Authors
- Boedicker, J. Q., Li, L., Kline, T. R., & Ismagilov, R. F.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 8
- Pages
- 1265
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2111491330
- Cited by
- 438
- References
- 39
- FWCI
- 14.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.