The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Towards non- and minimally instrumented, microfluidics-based diagnostic devices
Open accessAbstract
In many health care settings, it is uneconomical, impractical, or unaffordable to maintain and access a fully equipped diagnostics laboratory. Examples include home health care, developing-country health care, and emergency situations in which first responders are dealing with pandemics or biowarfare agent release. In those settings, fully disposable diagnostic devices that require no instrument support, reagent, or significant training are well suited. Although the only such technology to have found widespread adoption so far is the immunochromatographic rapid assay strip test, microfluidics holds promise to expand the range of assay technologies that can be performed in formats similar to that of a strip test. In this paper, we review progress toward development of disposable, low-cost, easy-to-use microfluidics-based diagnostics that require no instrument at all. We also present examples of microfluidic functional elements--including mixers, separators, and detectors--as well as complete microfluidic devices that function entirely without any moving parts and external power sources.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Microfluidic diagnostic technologies for global public health
Yager, P., Edwards, T., Fu, E., Helton, K., Nelson, K., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,979
Self-citation(1995) · Springer eBooks · doi:10.1007/978-94-011-0161-5 · Cited by 1,250
Passive mixing in a three-dimensional serpentine microchannel
Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., Aref, H., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.846699 · Cited by 1,197
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Self-citationDiagnostics for the developing world
Mabey, D., Peeling, R. W., Ustianowski, A., & Perkins, M. D. (2004) · Nature Reviews Microbiology · doi:10.1038/nrmicro841 · Cited by 1,054
Lab-on-a-chip devices for global health: Past studies and future opportunities
Chin, C. D., Linder, V., & Sia, S. K. (2007) · Lab Chip · doi:10.1039/b611455e · Cited by 811
PCR microfluidic devices for DNA amplification
Zhang, C., Xu, J., Ma, W., & Zheng, W. (2006) · Biotechnology Advances · doi:10.1016/j.biotechadv.2005.10.002 · Cited by 634
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
A fully integrated microfluidic genetic analysis system with sample-in–answer-out capability
Easley, C. J., Karlinsey, J. M., Bienvenue, J. M., Legendre, L. A., Roper, M. G., Feldman, S. H., Hughes, M. A., Hewlett, E. L., Merkel, T. J., Ferrance, J. P., et al. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0604663103 · Cited by 547
Cited by
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Microfluidic Devices for Bioapplications
Yeo, L. Y., Chang, H., Chan, P. P. Y., & Friend, J. R. (2011) · Small · doi:10.1002/smll.201000946 · Cited by 622
Point-of-care testing (POCT) diagnostic systems using microfluidic lab-on-a-chip technologies
Jung, W., Han, J., Choi, J.-W., & Ahn, C. H. (2015) · Microelectronic Engineering · doi:10.1016/j.mee.2014.09.024 · Cited by 510
Foudeh, A. M., Fatanat Didar, T., Veres, T., & Tabrizian, M. (2012) · Lab on a Chip · doi:10.1039/c2lc40630f · Cited by 457
Capillary microfluidics in microchannels: from microfluidic networks to capillaric circuits
Olanrewaju, A., Beaugrand, M., Yafia, M., & Juncker, D. (2018) · Lab on a Chip · doi:10.1039/c8lc00458g · Cited by 451
Advances in Plasmonic Technologies for Point of Care Applications
Tokel, O., Inci, F., & Demirci, U. (2014) · Chemical Reviews · doi:10.1021/cr4000623 · Cited by 407
Paper-based microfluidics: Simplified fabrication and assay methods
Nishat, S., Jafry, A. T., Martinez, A. W., & Awan, F. R. (2021) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2021.129681 · Cited by 392
Optical imaging techniques for point-of-care diagnostics
Zhu, H., Isikman, S. O., Mudanyali, O., Greenbaum, A., & Ozcan, A. (2013) · Lab Chip · doi:10.1039/c2lc40864c · Cited by 364
Nano/Microfluidics for diagnosis of infectious diseases in developing countries
Lee, W. G., Kim, Y.-G., Chung, B. G., Demirci, U., & Khademhosseini, A. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.11.016 · Cited by 357
Microfluidics for medical diagnostics and biosensors
Rivet, C., Lee, H., Hirsch, A., Hamilton, S., & Lu, H. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.08.015 · Cited by 356
Handheld high-throughput plasmonic biosensor using computational on-chip imaging
Cetin, A. E., Coskun, A. F., Galarreta, B. C., Huang, M., Herman, D., Ozcan, A., & Altug, H. (2014) · Light: Science & Applications · doi:10.1038/lsa.2014.3 · Cited by 354
Droplet microfluidics: recent developments and future applications
Casadevall i Solvas, X., & deMello, A. (2011) · Chem. Commun. · doi:10.1039/c0cc02474k · Cited by 353
Point-of-Care Diagnostics in Low Resource Settings: Present Status and Future Role of Microfluidics
Sharma, S., Zapatero-Rodríguez, J., Estrela, P., & O'Kennedy, R. (2015) · Biosensors · doi:10.3390/bios5030577 · Cited by 349
Gervais, L., & Delamarche, E. (2009) · Lab on a Chip · doi:10.1039/b906523g · Cited by 345
Fundamentals and application of magnetic particles in cell isolation and enrichment: a review
Plouffe, B. D., Murthy, S. K., & Lewis, L. H. (2015) · Reports on Progress in Physics · doi:10.1088/0034-4885/78/1/016601 · Cited by 334
Gao, Z., Ye, H., Tang, D., Tao, J., Habibi, S., Minerick, A., Tang, D., & Xia, X. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b02385 · Cited by 333
Current Advances in Detection and Treatment of Babesiosis
Mosqueda, J., Olvera-Ramirez, A., Aguilar-Tipacamu, G., & Canto, G. J. (2012) · Current Medicinal Chemistry · doi:10.2174/092986712799828355 · Cited by 319
Evolution of Biochip Technology: A Review from Lab-on-a-Chip to Organ-on-a-Chip
Azizipour, N., Avazpour, R., Rosenzweig, D. H., Sawan, M., & Ajji, A. (2020) · Micromachines · doi:10.3390/mi11060599 · Cited by 277
Thread as a Versatile Material for Low-Cost Microfluidic Diagnostics
Li, X., Tian, J., & Shen, W. (2010) · ACS Applied Materials & Interfaces · doi:10.1021/am9006148 · Cited by 275
Microfluidic Point-of-Care Testing: Commercial Landscape and Future Directions
Sachdeva, S., Davis, R. W., & Saha, A. K. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.602659 · Cited by 262
Lab-on-a-Foil: microfluidics on thin and flexible films
Focke, M., Kosse, D., Müller, C., Reinecke, H., Zengerle, R., & von Stetten, F. (2010) · Lab on a Chip · doi:10.1039/c001195a · Cited by 255
Plouffe, B. D., Mahalanabis, M., Lewis, L. H., Klapperich, C. M., & Murthy, S. K. (2012) · Analytical Chemistry · doi:10.1021/ac2022844 · Cited by 96
Metadata
- Authors
- Weigl, B., Domingo, G., LaBarre, P., & Gerlach, J.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 12
- Pages
- 1999
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1964597866
- Cited by
- 259
- References
- 36
- FWCI
- 15.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.