The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Electrochemical sensing in paper-based microfluidic devices
Open accessAbstract
This paper describes the fabrication and the performance of microfluidic paper-based electrochemical sensing devices (we call the microfluidic paper-based electrochemical devices, microPEDs). The microPEDs comprise paper-based microfluidic channels patterned by photolithography or wax printing, and electrodes screen-printed from conducting inks (e.g., carbon or Ag/AgCl). We demonstrated that the microPEDs are capable of quantifying the concentrations of various analytes (e.g., heavy-metal ions and glucose) in aqueous solutions. This low-cost analytical device should be useful for applications in public health, environmental monitoring, and the developing world.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Methods: Fundamentals and Applications
Bard, A. J., & Faulkner, L. R. (1980) · Cited by 22,824
Electrochemical Methods: Fundamentals and Applications
de Rooij, D. M. R. (2003) · Anti-Corrosion Methods and Materials · doi:10.1108/acmm.2003.12850eae.001 · Cited by 13,009
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
Self-citationUnderstanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics
Carrilho, E., Martinez, A. W., & Whitesides, G. M. (2009) · Analytical Chemistry · doi:10.1021/ac901071p · Cited by 1,612
Self-citationMartinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,443
Self-citationThree-dimensional microfluidic devices fabricated in layered paper and tape
Martinez, A. W., Phillips, S. T., & Whitesides, G. M. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810903105 · Cited by 1,246
Self-citationElectrochemical Detection for Paper-Based Microfluidics
Dungchai, W., Chailapakul, O., & Henry, C. S. (2009) · Analytical Chemistry · doi:10.1021/ac9007573 · Cited by 1,224
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Diagnostics for the developing world
Mabey, D., Peeling, R. W., Ustianowski, A., & Perkins, M. D. (2004) · Nature Reviews Microbiology · doi:10.1038/nrmicro841 · Cited by 1,054
Bismuth-Coated Carbon Electrodes for Anodic Stripping Voltammetry
Wang, J., Lu, J., Hocevar, S. B., Farias, P. A. M., & Ogorevc, B. (2000) · Analytical Chemistry · doi:10.1021/ac000108x · Cited by 1,004
FLASH: A rapid method for prototyping paper-based microfluidic devices
Martinez, A. W., Phillips, S. T., Wiley, B. J., Gupta, M., & Whitesides, G. M. (2008) · Lab on a Chip · doi:10.1039/b811135a · Cited by 695
Self-citationPatra, M., Bhowmik, N., Bandopadhyay, B., & Sharma, A. (2004) · Environmental and Experimental Botany · doi:10.1016/j.envexpbot.2004.02.009 · Cited by 679
Recent developments in the field of screen-printed electrodes and their related applications
Renedo, O. D., Alonso-Lomillo, M. A., & Martínez, M. J. A. (2007) · Talanta · doi:10.1016/j.talanta.2007.03.050 · Cited by 647
Electrochemical Sensors for Clinic Analysis
Wang, Y., Xu, H., Zhang, J., & Li, G. (2008) · Sensors · doi:10.3390/s8042043 · Cited by 398
Kumar Jena, B., & Retna Raj, C. (2008) · Analytical Chemistry · doi:10.1021/ac071064w · Cited by 352
PORTER, S. K., SCHECKEL, K. G., IMPELLITTERI, C. A., & RYAN, J. A. (2004) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643380490492412 · Cited by 243
Yantasee, W., Lin, Y., Hongsirikarn, K., Fryxell, G. E., Addleman, R., & Timchalk, C. (2007) · Environmental Health Perspectives · doi:10.1289/ehp.10190 · Cited by 179
The Technology Behind Glucose Meters: Test Strips
Hönes, J., Müller, P., & Surridge, N. A. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0005 · Cited by 161
Cui, G., Kim, S. J., Choi, S. H., Nam, H., Cha, G. S., & Paeng, K. (2000) · Analytical Chemistry · doi:10.1021/ac991213d · Cited by 84
Cited by
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Wood-Derived Materials for Green Electronics, Biological Devices, and Energy Applications
Zhu, H., Luo, W., Ciesielski, P. N., Fang, Z., Zhu, J. Y., Henriksson, G., Himmel, M. E., & Hu, L. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00225 · Cited by 1,532
Aragay, G., Pons, J., & Merkoçi, A. (2011) · Chemical Reviews · doi:10.1021/cr100383r · Cited by 1,396
Recent Developments in Paper-Based Microfluidic Devices
Cate, D. M., Adkins, J. A., Mettakoonpitak, J., & Henry, C. S. (2015) · Analytical Chemistry · doi:10.1021/ac503968p · Cited by 1,236
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Metadata
- Authors
- Nie, Z., Nijhuis, C. A., Gong, J., Chen, X., Kumachev, A., Martinez, A. W., Narovlyansky, M., & Whitesides, G. M.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 10
- Issue
- 4
- Pages
- 477-483
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2113558416
- Cited by
- 929
- References
- 19
- FWCI
- 19.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.